1.Applications of ocular point-of-care ultrasound assessment in the emergency setting: a scoping review
Christopher D. YANG ; Christine K. KIM ; Melissa M. CHANG ; Pooya KHOSRAVI ; Ajeet Pal Bayo BHATIA ; Amanda dos SANTOS ; Kyle DORNHOFER ; Megan GUY ; Edmund HSU ; Soheil SAADAT ; John Christian FOX
Clinical and Experimental Emergency Medicine 2025;12(3):188-197
Objective:
To evaluate the current body of literature pertaining to the use of ocular point-of-care ultrasound (POCUS) in the emergency department (ED).
Methods:
A comprehensive literature search was conducted on Scopus, Web of Science, MEDLINE, and Cochrane Central Register of Controlled Trials (CENTRAL) databases. Inclusion criteria were studies written in English and primary clinical studies involving ocular POCUS scans in an ED setting. Exclusion criteria were nonprimary studies (e.g., reviews or case reports), studies written in a non-English language, nonhuman studies, studies performed in a nonemergency setting, studies involving non-POCUS ocular ultrasound modalities, or studies published more than 10 years prior. Data extraction was guided by the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) recommendations.
Results:
The initial search yielded 391 results with 153 duplicates. Of the remaining 238 studies selected for retrieval and screening, 24 met the inclusion criteria. These 24 included studies encompassed 2,448 patients across prospective, retrospective, cross-sectional, and case series study designs. The majority of included studies focused on the use of POCUS in the ED to measure optic nerve sheath diameter as a proxy for papilledema and metabolic aberrations, while a minority of studies used ocular POCUS to assist in the diagnosis of orbital fractures or posterior segment pathology.
Conclusion
The vast majority of studies investigating the use of ocular POCUS in recent years emphasize its utility in measuring optic nerve sheath diameter and fluctuations in intracranial pressure, though additional outcomes of interest include pathology of the posterior segment, orbit, and globe.
2.The correlation between carotid artery Doppler and stroke volume during central blood volume loss and resuscitation
Isabel KERREBIJN ; Sarah ATWI ; Mai ELFARNAWANY ; Andrew M. EIBL ; Joseph K. EIBL ; Jenna L. TAYLOR ; Chul Ho KIM ; Bruce D. JOHNSON ; Jon-Émile S. KENNY
Acute and Critical Care 2024;39(1):162-168
Using peripheral arteries to infer central hemodynamics is common among hemodynamic monitors. Doppler ultrasound of the common carotid artery has been used in this manner with conflicting results. We investigated the relationship between changing common carotid artery Doppler measures and stroke volume (SV), hypothesizing that more consecutively-averaged cardiac cycles would improve SV-carotid Doppler correlation. Methods: Twenty-seven healthy volunteers were recruited and studied in a physiology laboratory. Carotid artery Doppler pulse was measured with a wearable, wireless ultrasound during central hypovolemia and resuscitation induced by a stepped lower body negative pressure protocol. The change in maximum velocity time integral (VTI) and corrected flow time of the carotid artery (ccFT) were compared with changing SV using repeated measures correlation. Results: In total, 73,431 cardiac cycles were compared across 27 subjects. There was a strong linear correlation between changing SV and carotid Doppler measures during simulated hemorrhage (repeated-measures linear correlation [Rrm ]=0.91 for VTI; 0.88 for ccFT). This relationship improved with larger numbers of consecutively-averaged cardiac cycles. For ccFT, beyond four consecutively-averaged cardiac cycles the correlation coefficient remained strong (i.e., Rrm of at least 0.80). For VTI, the correlation coefficient with SV was strong for any number of averaged cardiac cycles. For both ccFT and VTI, Rrm remained stable around 25 consecutively-averaged cardiac cycles. Conclusions: There was a strong linear correlation between changing SV and carotid Doppler measures during central blood volume loss. The strength of this relationship was dependent upon the number of consecutively-averaged cardiac cycles.
3.The correlation between carotid artery Doppler and stroke volume during central blood volume loss and resuscitation
Isabel KERREBIJN ; Sarah ATWI ; Mai ELFARNAWANY ; Andrew M. EIBL ; Joseph K. EIBL ; Jenna L. TAYLOR ; Chul Ho KIM ; Bruce D. JOHNSON ; Jon-Émile S. KENNY
Acute and Critical Care 2024;39(1):162-168
Using peripheral arteries to infer central hemodynamics is common among hemodynamic monitors. Doppler ultrasound of the common carotid artery has been used in this manner with conflicting results. We investigated the relationship between changing common carotid artery Doppler measures and stroke volume (SV), hypothesizing that more consecutively-averaged cardiac cycles would improve SV-carotid Doppler correlation. Methods: Twenty-seven healthy volunteers were recruited and studied in a physiology laboratory. Carotid artery Doppler pulse was measured with a wearable, wireless ultrasound during central hypovolemia and resuscitation induced by a stepped lower body negative pressure protocol. The change in maximum velocity time integral (VTI) and corrected flow time of the carotid artery (ccFT) were compared with changing SV using repeated measures correlation. Results: In total, 73,431 cardiac cycles were compared across 27 subjects. There was a strong linear correlation between changing SV and carotid Doppler measures during simulated hemorrhage (repeated-measures linear correlation [Rrm ]=0.91 for VTI; 0.88 for ccFT). This relationship improved with larger numbers of consecutively-averaged cardiac cycles. For ccFT, beyond four consecutively-averaged cardiac cycles the correlation coefficient remained strong (i.e., Rrm of at least 0.80). For VTI, the correlation coefficient with SV was strong for any number of averaged cardiac cycles. For both ccFT and VTI, Rrm remained stable around 25 consecutively-averaged cardiac cycles. Conclusions: There was a strong linear correlation between changing SV and carotid Doppler measures during central blood volume loss. The strength of this relationship was dependent upon the number of consecutively-averaged cardiac cycles.
4.The correlation between carotid artery Doppler and stroke volume during central blood volume loss and resuscitation
Isabel KERREBIJN ; Sarah ATWI ; Mai ELFARNAWANY ; Andrew M. EIBL ; Joseph K. EIBL ; Jenna L. TAYLOR ; Chul Ho KIM ; Bruce D. JOHNSON ; Jon-Émile S. KENNY
Acute and Critical Care 2024;39(1):162-168
Using peripheral arteries to infer central hemodynamics is common among hemodynamic monitors. Doppler ultrasound of the common carotid artery has been used in this manner with conflicting results. We investigated the relationship between changing common carotid artery Doppler measures and stroke volume (SV), hypothesizing that more consecutively-averaged cardiac cycles would improve SV-carotid Doppler correlation. Methods: Twenty-seven healthy volunteers were recruited and studied in a physiology laboratory. Carotid artery Doppler pulse was measured with a wearable, wireless ultrasound during central hypovolemia and resuscitation induced by a stepped lower body negative pressure protocol. The change in maximum velocity time integral (VTI) and corrected flow time of the carotid artery (ccFT) were compared with changing SV using repeated measures correlation. Results: In total, 73,431 cardiac cycles were compared across 27 subjects. There was a strong linear correlation between changing SV and carotid Doppler measures during simulated hemorrhage (repeated-measures linear correlation [Rrm ]=0.91 for VTI; 0.88 for ccFT). This relationship improved with larger numbers of consecutively-averaged cardiac cycles. For ccFT, beyond four consecutively-averaged cardiac cycles the correlation coefficient remained strong (i.e., Rrm of at least 0.80). For VTI, the correlation coefficient with SV was strong for any number of averaged cardiac cycles. For both ccFT and VTI, Rrm remained stable around 25 consecutively-averaged cardiac cycles. Conclusions: There was a strong linear correlation between changing SV and carotid Doppler measures during central blood volume loss. The strength of this relationship was dependent upon the number of consecutively-averaged cardiac cycles.
5.The correlation between carotid artery Doppler and stroke volume during central blood volume loss and resuscitation
Isabel KERREBIJN ; Sarah ATWI ; Mai ELFARNAWANY ; Andrew M. EIBL ; Joseph K. EIBL ; Jenna L. TAYLOR ; Chul Ho KIM ; Bruce D. JOHNSON ; Jon-Émile S. KENNY
Acute and Critical Care 2024;39(1):162-168
Using peripheral arteries to infer central hemodynamics is common among hemodynamic monitors. Doppler ultrasound of the common carotid artery has been used in this manner with conflicting results. We investigated the relationship between changing common carotid artery Doppler measures and stroke volume (SV), hypothesizing that more consecutively-averaged cardiac cycles would improve SV-carotid Doppler correlation. Methods: Twenty-seven healthy volunteers were recruited and studied in a physiology laboratory. Carotid artery Doppler pulse was measured with a wearable, wireless ultrasound during central hypovolemia and resuscitation induced by a stepped lower body negative pressure protocol. The change in maximum velocity time integral (VTI) and corrected flow time of the carotid artery (ccFT) were compared with changing SV using repeated measures correlation. Results: In total, 73,431 cardiac cycles were compared across 27 subjects. There was a strong linear correlation between changing SV and carotid Doppler measures during simulated hemorrhage (repeated-measures linear correlation [Rrm ]=0.91 for VTI; 0.88 for ccFT). This relationship improved with larger numbers of consecutively-averaged cardiac cycles. For ccFT, beyond four consecutively-averaged cardiac cycles the correlation coefficient remained strong (i.e., Rrm of at least 0.80). For VTI, the correlation coefficient with SV was strong for any number of averaged cardiac cycles. For both ccFT and VTI, Rrm remained stable around 25 consecutively-averaged cardiac cycles. Conclusions: There was a strong linear correlation between changing SV and carotid Doppler measures during central blood volume loss. The strength of this relationship was dependent upon the number of consecutively-averaged cardiac cycles.
6.2021 Asian Pacific Society of Cardiology Consensus Recommendations on the use of P2Y12 receptor antagonists in the Asia-Pacific Region: Special populations.
W E I C H I E H T A N TAN ; P C H E W CHEW ; L A M T S U I TSUI ; T A N TAN ; D U P L Y A K O V DUPLYAKOV ; H A M M O U D E H HAMMOUDEH ; Bo ZHANG ; Yi LI ; Kai XU ; J O N G ONG ; Doni FIRMAN ; G A M R A GAMRA ; A L M A H M E E D ALMAHMEED ; D A L A L DALAL ; T A N TAN ; S T E G STEG ; N N G U Y E N NGUYEN ; A K O AKO ; A L S U W A I D I SUWAIDI ; C H A N CHAN ; S O B H Y SOBHY ; S H E H A B SHEHAB ; B U D D H A R I BUDDHARI ; Zu Lv WANG ; Y E A N Y I P F O N G FONG ; K A R A D A G KARADAG ; K I M KIM ; B A B E R BABER ; T A N G C H I N CHIN ; Ya Ling HAN
Chinese Journal of Cardiology 2023;51(1):19-31
7.How Does the Severity of Neuroforaminal Compression in Cervical Radiculopathy Affect Outcomes of Anterior Cervical Discectomy and Fusion
Mark J. LAMBRECHTS ; Tariq Z. ISSA ; Yunsoo LEE ; Khoa S. TRAN ; Jeremy HEARD ; Caroline PURTILL ; Tristan B. FRIED ; Samuel OH ; Erin KIM ; John J. MANGAN ; Jose A. CANSECO ; I. David KAYE ; Jeffrey A. RIHN ; Alan S. HILIBRAND ; Alexander R. VACCARO ; Christopher K. KEPLER ; Gregory D. SCHROEDER
Asian Spine Journal 2023;17(6):1051-1058
Methods:
Patients undergoing primary, elective 1–3 level ACDF for radiculopathy at a single academic center between 2015 and 2021 were identified retrospectively. Cervical FS was evaluated using axial T2-weighted MRI images via a validated grading scale. The maximum degree of stenosis was used for multilevel disease. Motor symptoms were classified using encounters at their final preoperative and first postoperative visits, with examinations ≤3/5 indicating weakness. PROMs were obtained preoperatively and at 1-year follow-up. Bivariate analysis was used to compare outcomes based on stenosis severity, followed by multivariable analysis.
Results:
This study included 354 patients, 157 with moderate stenosis and 197 with severe stenosis. Overall, 58 patients (16.4%) presented with upper extremity weakness ≤3/5. A similar number of patients in both groups presented with baseline motor weakness (13.5% vs. 16.55, p =0.431). Postoperatively, 97.1% and 87.0% of patients with severe and moderate FS, respectively, experienced full motor recovery (p =0.134). At 1-year, patients with severe neuroforaminal stenosis presented with significantly worse 12-item Short Form Survey Physical Component Score (PCS-12) (33.3 vs. 37.3, p =0.049) but demonstrated a greater magnitude of improvement (Δ PCS-12: 5.43 vs. 0.87, p =0.048). Worse stenosis was independently associated with greater ΔPCS-12 at 1-year (β =5.59, p =0.022).
Conclusions
Patients with severe FS presented with worse preoperative physical health. While ACDF improved outcomes and conferred similar motor recovery in all patients, those with severe FS reported much better improvement in physical function.
8.Updated New York City Emergency Medical Services Acute Stroke Triage Protocol Reduces Interfacility Transfers and Time to Endovascular Thrombectomy for Emergent Large Vessel Occlusion Stroke Patients
Jacob R. MOREY ; Brian D. KIM ; Michael REDLENER ; Xiangnan ZHANG ; Naoum Fares MARAYATI ; Stavros MATSOUKAS ; Emily FIANO ; Laura K. STEIN ; J MOCCO ; Johanna T. FIFI
Journal of Stroke 2022;24(3):417-420
9.Management of complex surgical wounds of the back: identifying an evidence-based approach
Elizabeth G. ZOLPER ; Meher A. SALEEM ; Kevin G. KIM ; Mark D. MISHU ; Sarah R. SHER ; Christopher E. ATTINGER ; Kenneth L. FAN ; Karen K. EVANS
Archives of Plastic Surgery 2021;48(6):599-606
Background:
Postoperative dehiscence and surgical site infection after spinal surgery can carry serious morbidity. Multidisciplinary involvement of plastic surgery is essential to minimizing morbidity and achieving definitive closure. However, a standardized approach is lacking. The aim of this study was to identify effective reconstructive interventions for the basis of an evidence-based management protocol.
Methods:
A retrospective review was performed at a single tertiary institution for 45 patients who required 53 reconstruction procedures with plastic surgery for wounds secondary to spinal surgery from 2010 to 2019. Statistical analysis was performed for demographics, comorbidities, and treatment methods. Primary outcomes were postoperative complications, including dehiscence, seroma, and infection. The secondary outcome was time to healing.
Results:
The overall complication rate was 32%, with dehiscence occurring in 17%, seroma in 15% and infection in 11% of cases. Median follow-up was 10 months (interquartile range, 4–23). Use of antibiotic beads did not affect rate of infection occurrence after wound closure (P=0.146). Use of incisional negative pressure wound therapy (iNPWT) was significant for reduced time to healing (P=0.001). Patients treated without iNPWT healed at median of 67.5 days while the patients who received iNPWT healed in 33 days. Demographics and comorbidities between these two groups were similar.
Conclusions
This data provides groundwork for an evidence-based approach to soft tissue reconstruction and management of dehiscence after spinal surgery. Timely involvement of plastic surgery in high-risk patients and utilization of evidence-based interventions such as iNPWT are essential for improving outcomes in this population.
10.Clinical Targeted Next-Generation sequencing Panels for Detection of Somatic Variants in Gliomas
Hyemi SHIN ; Jason K. SA ; Joon Seol BAE ; Harim KOO ; Seonwhee JIN ; Hee Jin CHO ; Seung Won CHOI ; Jong Min KYOUNG ; Ja Yeon KIM ; Yun Jee SEO ; Je-Gun JOUNG ; Nayoung K. D. KIM ; Dae-Soon SON ; Jongsuk CHUNG ; Taeseob LEE ; Doo-Sik KONG ; Jung Won CHOI ; Ho Jun SEOL ; Jung-Il LEE ; Yeon-Lim SUH ; Woong-Yang PARK ; Do-Hyun NAM
Cancer Research and Treatment 2020;52(1):41-50
Purpose:
Targeted next-generation sequencing (NGS) panels for solid tumors have been useful in clinical framework for accurate tumor diagnosis and identifying essential molecular aberrations. However, most cancer panels have been designed to address a wide spectrum of pan-cancer models, lacking integral prognostic markers that are highly specific to gliomas.
Materials and Methods:
To address such challenges, we have developed a glioma-specific NGS panel, termed “GliomaSCAN,” that is capable of capturing single nucleotide variations and insertion/deletion, copy number variation, and selected promoter mutations and structural variations that cover a subset of intron regions in 232 essential glioma-associated genes. We confirmed clinical concordance rate using pairwise comparison of the identified variants from whole exome sequencing (WES), immunohistochemical analysis, and fluorescence in situ hybridization.
Results:
Our panel demonstrated high sensitivity in detecting potential genomic variants that were present in the standard materials. To ensure the accuracy of our targeted sequencing panel, we compared our targeted panel to WES. The comparison results demonstrated a high correlation. Furthermore, we evaluated clinical utility of our panel in 46 glioma patients to assess the detection capacity of potential actionable mutations. Thirty-two patients harbored at least one recurrent somatic mutation in clinically actionable gene.
Conclusion
We have established a glioma-specific cancer panel. GliomaSCAN highly excelled in capturing somatic variations in terms of both sensitivity and specificity and provided potential clinical implication in facilitating genome-based clinical trials. Our results could provide conceptual advance towards improving the response of genomically guided molecularly targeted therapy in glioma patients.

Result Analysis
Print
Save
E-mail