1.Clinical outcomes following microsurgery and endovascular embolization in the management of spinal dural arteriovenous fistula: A meta-analysis study.
Chang Wei YUAN ; Ying Jin WANG ; Shu Jie ZHANG ; Sheng Li SHEN ; Hong Zhou DUAN
Journal of Peking University(Health Sciences) 2022;54(2):304-314
OBJECTIVE:
To compare the clinical effect of microsurgery and endovascular embolization in the treatment of spinal dural arteriovenous fistula (SDAVF) by meta-analysis.
METHODS:
A systematic review was performed to retrieve all relevant literature about surgical treatment or endovascular embolization of SDAVF up to December 2019 through PubMed, Embase, Web of Science, Cochrane Central Register of Controlled Trials Results, CNKI, Wanfang Data, and SinoMed. The Chinese and English key words included: "SDAVF", "spinal dural arteriovenous fistula", "spinal AVM", "spinal vascular malformation and treatment". The included studies were evaluated using the Newcastle-Ottawa scale. The early failure rate, long-term recurrence, neurological recovery, and complications were evaluated and the clinical effects of the two methods in the treatment of SDAVF were compared by using RevMan 5.3 software. And a further subgroup analysis of the therapeutic effect of endovascular embolization with different embolic agents was conducted.
RESULTS:
A total of 46 studies involving 1 958 cases of SDAVF were included, in which 935 cases were treated by microsurgery and 1 023 cases were treated by endovascular embolization. The funnel plot demonstrated that there was no publication bias. The results of meta-analysis showed that the incidence of early surgical failure was lower than that of endovascular embolization (OR=0.20, 95%CI: 0.13-0.30, P < 0.05), and the long-term recurrence was also lower than that of endovascular embolization (OR=0.36, 95%CI: 0.22-0.58, P < 0.05). The improvement of neurological function in the surgical patients is significantly higher than that in the patients treated with endovascular embolization (OR=2.86, 95%CI: 1.36-5.99, P < 0.05). There was no significant difference in the occurrence of complications in these two groups (OR=1.52, 95%CI: 0.88-2.64, P=0.14). In the cases of endovascular embolization, the risk of treatment failure or recurrence was higher with Onyx glue than with n-butyl 2-cyanoacrylate (NBCA), and the difference was statistically significant (OR=4.70, 95%CI: 1.55-14.28, P < 0.05).
CONCLUSION
Although the treatment of dural arteriovenous fistulas by intravascular embolization has been widely used, the clinical effect of microsurgery is still better than that of endovascular embolization. Large scale and high-quality randomized controlled trials are required to validate the efficacy and safety of endovascular treatment in SDAVF patients.
Central Nervous System Vascular Malformations/surgery*
;
Embolization, Therapeutic/methods*
;
Enbucrilate/therapeutic use*
;
Endovascular Procedures/methods*
;
Humans
;
Microsurgery/methods*
;
Retrospective Studies
;
Treatment Outcome
2.Comparing intra-oral wound healing after alveoloplasty using silk sutures and n-butyl-2-cyanoacrylate
Pratik SUTHAR ; Sonal SHAH ; Pushkar WAKNIS ; Gandhali LIMAYE ; Aditi SAHA ; Pranav SATHE
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2020;46(1):28-35
OBJECTIVES: The need for proper wound closure is of paramount importance after any intra-oral surgery. Various wound closure techniques have been described in literature using traditional non-absorbable suture materials. These include like synthetic absorbable sutures, surgical staples and tissue adhesives. Cyanoacrylates are among the most commonly used biocompatible tissue adhesives. To evaluate and compare intraoral wound healing using 3-0 silk sutures and n-butyl-2-cyanoacrylate after alveoloplasty.MATERIALS AND METHODS: A total of 20 patients requiring bilateral alveoloplasty in the same arch (upper or lower) were included in this study. Patients with any pre-existing pathology or systemic disease were excluded. After alveoloplasty was performed, the wound was closed using 3-0 braided silk sutures on one side, and using n-butyl-2-cyanoacrylate bio adhesive on the other side. Patients were evaluated based on the following parameters: time required to achieve wound closure; the incidence of immediate and postoperative hemostasis; the time to the use of the first rescue medication; the side where pain first arises; and the side where wound healing begins first.RESULTS: Compared to 3-0 silk sutures, cyanoacrylate demonstrated better hemostatic properties, reduced operative time, reduced postoperative pain and better wound healing.CONCLUSION: These data suggest that cyanoacrylate glue is an adequate alternative to conventional sutures to close the surgical wound after alveoloplasty, and better than are 3-0 silk sutures.
Adhesives
;
Alveoloplasty
;
Cyanoacrylates
;
Enbucrilate
;
Hemostasis
;
Humans
;
Incidence
;
Operative Time
;
Pain, Postoperative
;
Pathology
;
Silk
;
Sutures
;
Tissue Adhesives
;
Wound Closure Techniques
;
Wound Healing
;
Wounds and Injuries
3.Coil-Protected Technique for Liquid Embolization in Neurovascular Malformations
Keun Young PARK ; Jin Woo KIM ; Byung Moon KIM ; Dong Joon KIM ; Joonho CHUNG ; Chang Ki JANG ; Jun Hwee KIM
Korean Journal of Radiology 2019;20(8):1285-1292
OBJECTIVE: To evaluate the safety and efficacy of the coil-protected technique for liquid embolization in neurovascular malformations. MATERIALS AND METHODS: Twenty-two patients who underwent coil-protected liquid embolization for symptomatic cranial (n = 13) and spinal (n = 9) arteriovenous fistula (AVF) or arteriovenous malformations (AVMs) were identified. A total of 36 target feeder vessels were embolized with N-butyl cyanoacrylate and/or Onyx (Medtronic). This technique was used to promote delivery of a sufficient amount of liquid embolic agent into the target shunt or nidus in cases where tortuous feeding arteries preclude a microcatheter wedging techniqu and/or to prevent reflux of the liquid embolic agent in cases with a short safety margin. The procedure was considered technically successful if the target lesion was sufficiently filled with liquid embolic agent without unintentional reflux. Angiographic and clinical outcomes were retrospectively evaluated. RESULTS: Technical success was achieved for all 36 target feeders. Post-embolization angiographies revealed complete occlusion in 16 patients and near-complete and partial occlusion in three patients each. There were no treatment-related complications. Of the six patients who showed near-complete or partial occlusion, five received additional treatments: two received stereotactic radiosurgery for cerebral AVM, two underwent surgical removal of cerebral AVM, and one underwent additional embolization by direct puncture for a mandibular AVM. Finally, all patients showed complete (n = 19) or near-complete (n = 3) occlusion of the target AVF or AVM on follow-up angiographies. The presenting neurological symptoms improved completely in 15 patients (68.2%) and partially in seven patients (31.8%). CONCLUSION: The coil-protected technique is a safe and effective method for liquid embolization, especially in patients with various neurovascular shunts or malformations who could not be successfully treated with conventional techniques.
Angiography
;
Arteries
;
Arteriovenous Fistula
;
Arteriovenous Malformations
;
Cyanoacrylates
;
Follow-Up Studies
;
Humans
;
Methods
;
Punctures
;
Radiosurgery
;
Retrospective Studies
4.Clinical usefulness of fixation of absorbable implants with cyanoacrylate in comminuted fractures of the maxilla
Gang San JU ; Kyung Min SON ; Woo Young CHOI ; Ji Seon CHEON
Archives of Craniofacial Surgery 2019;20(4):233-238
BACKGROUND: The open reduction of craniofacial bone fractures requires internal fixation using metal plates and screws, which have been considered the gold standard. However, metal implants pose a risk of palpation, protrusion, and foreign body reaction, and they may require an additional operation for removal. Recently, good results have been reported for absorbable implants which complement the disadvantages of metal implants. This study presents the results of using absorbable mesh, plates, and screws with cyanoacrylate for more accurate and firmer fixation of comminuted fractures of the maxilla. METHODS: In total, 235 patients underwent operations for comminuted fractures of the maxilla. From January 2012 to December 2014, absorbable mesh and screws were used in 114 patients, while from January 2015 to December 2017, absorbable mesh, plates, and screws with cyanoacrylate were used in 121 patients. Open reduction of the bone fragments was performed, after which absorbable implants were accurately molded and fixed by screws. RESULTS: All patients underwent postoperative computed tomography scans, which showed highly accurate reduction and firm fixation in the patients who underwent procedures using absorbable implants, screws, and cyanoacrylate. There were no postoperative complications or cases of abnormal facial contour. CONCLUSION: When absorbable implants and screws are used for maxillary fractures, no additional surgery to remove the metal plate is required. In addition, the use of cyanoacrylate enables accurate and firm fixation of the tiny bone fragments that cannot be fixed with screws.
Absorbable Implants
;
Complement System Proteins
;
Cyanoacrylates
;
Foreign-Body Reaction
;
Fractures, Bone
;
Fractures, Comminuted
;
Fungi
;
Humans
;
Maxilla
;
Maxillary Fractures
;
Palpation
;
Postoperative Complications
5.Treatment of Pseudoaneurysm of Internal Maxillary Artery Resulting from Needle Injury
Na Young KIM ; Jong Yeon KIM ; Jhin Soo PYEN ; Kum WHAN ; Sung Min CHO ; Jong Wook CHOI
Korean Journal of Neurotrauma 2019;15(2):176-181
Pseudoaneurysm of internal maxillary artery (IMA) after trauma is rare, and most cases reported are caused by maxilla-facial blunt trauma. Pseudoaneurysm is discontinuity in the vascular wall leading to an extravascular hematoma that freely communicates with the intravascular space producing pulsatile hematoma rapidly. A 44-years-old woman presented with a pulsatile swelling and pain in the left parotid region. She underwent the masticatory muscle reduction using needle injection in dentistry 1 month ago. The left facial pulsatile swelling developed after the procedure immediately and uncontrolled bleeding occurred on the day of visit to our institution. We performed emergency angiography and diagnosed pseudoaneurysm of left IMA. We treated by embolization with Histoacryl Glue through left IMA. IMA total occlusion was confirmed and symptoms improved. Pseudoaneurysm following blunt trauma of the face have been reported but are few. Furthermore, there is no report of IMA pseudoaneurysm due to direct injury by needle. Recently, many cosmetic surgery procedures using injection techniques have been performed, and it is necessary to pay attention to the direct vessel injury by the needle. And endovascular therapies can give early recovery with minimal morbidity and avoids injury to the facial nerve and its branches.
Adhesives
;
Aneurysm, False
;
Angiography
;
Dentistry
;
Emergencies
;
Enbucrilate
;
Facial Nerve
;
Female
;
Hematoma
;
Hemorrhage
;
Humans
;
Masticatory Muscles
;
Maxillary Artery
;
Needles
;
Parotid Region
;
Surgery, Plastic
6.Biocompatibility of n-butyl-2-cyanoacrylate (Histoacryl) in cervical structures of rats: prospective in vivo study
Yong Joon SUH ; Hyeong Won YU ; Su JIn KIM ; Ji Young CHOE ; Hyo Jin PARK ; June Young CHOI ; Kyu Eun LEE
Annals of Surgical Treatment and Research 2019;96(4):162-168
PURPOSE: We investigated the biocompatibility of n-butyl-2-cyanoacrylate (NBCA) in the cervical deep tissues of rats to assess its biocompatibility. METHODS: A total of 30 Sprague-Dawley rats were injected with NBCA. After 30, 90, 180, and 360 days, cubes of tissue (1 cm × 1 cm × 1 cm) surrounding the NBCA and normal tissue from the other side of the neck were excised from each rat. The adhesion of NBCA to adjacent structures was examined histologically. Cells were counted per high-power field (HPF), and fibrosis was graded with the measurement of fibrotic thickening. RESULTS: All animals displayed normal behavior without any symptoms of distress throughout the study. There was no recognizable inflammatory reaction, foreign body reaction, or fibrosis in the 30 control samples. The analyses of experimental samples showed significantly decreased inflammatory cell counts over time (lymphoplasma cell count decreased from 100 (range, 70–100) to 30 (range, 30–50) per HPF, P = 0.010; neutrophil count decreased from 2 (range, 2–30) to 0 (range, 0–2) per HPF, P = 0.017). However, there was no significant difference in the number of multinuclear giant cells throughout the study period (a decrease from 22 [range, 16–34] to 16 [range, 12–22] per HPF, P = 0.287). The level of fibrosis was Common Toxicity Criteria ver. 4.0 Grade 1 without further thickening (P = 0.600). However, maturation of fibrosis progressed gradually. CONCLUSION: NBCA was biologically tolerable in the cervical deep tissues of rats. However, precautions are needed with respect to preventing a sustained foreign body reaction and fibrosis.
Animals
;
Biocompatible Materials
;
Cell Count
;
Chyle
;
Cyanoacrylates
;
Enbucrilate
;
Fibrosis
;
Foreign-Body Reaction
;
Giant Cells
;
Neck
;
Neck Dissection
;
Neutrophils
;
Prospective Studies
;
Rats
;
Rats, Sprague-Dawley
7.Gallbladder Fistula Treated with N-Butyl-2-Cyanoacrylate after Radiofrequency Ablation in a Hepatocellular Carcinoma Patient: a Case Report
In Tae SO ; Byoung Kook JANG ; Jae Seok HWANG ; Young hwan KIM
Journal of Liver Cancer 2019;19(1):69-73
Radiofrequency ablation (RFA) is a minimally invasive local therapy for hepatocellular carcinoma (HCC). Even though RFA is considered to be a safe treatment modality, a variety of complications have been reported. Recently, we encountered a case of refractory fistula between a liver abscess and the gallbladder after RFA. A 64-year-old woman diagnosed with HCC associated with chronic hepatitis B was treated by RFA. After RFA, she experienced abdominal pain, and abdominal computed tomography (CT) revealed a liver abscess complicated by a previous treatment of HCC, she was treated with intravenous antibiotics and percutaneous abscess drainage. Follow-up abdominal CT revealed a fistula between the liver abscess and gallbladder, which was successfully treated with percutaneous transcatheter n-butyl-2-cyanoacrylate (NBCA) embolization. We herein report the rare case of a refractory fistula between a liver abscess and the gallbladder after RFA in a patient treated with NBCA embolization.
Abdominal Pain
;
Abscess
;
Anti-Bacterial Agents
;
Carcinoma, Hepatocellular
;
Catheter Ablation
;
Drainage
;
Enbucrilate
;
Female
;
Fistula
;
Follow-Up Studies
;
Gallbladder
;
Hepatitis B, Chronic
;
Humans
;
Liver Abscess
;
Middle Aged
;
Tomography, X-Ray Computed
8.Multiple Cerebral Infarction after Injection of N-Butyl-2-Cyanoacrylate for Gastric Variceal Bleeding
Journal of the Korean Neurological Association 2019;37(1):73-77
Endoscopic obliteration with N-butyl-2-cyanoacrylate is the first-line treatment for gastric variceal bleeding. Although N-butyl-2-cyanoacrylate has higher success rate, there is some fatal complications such as systemic embolization. We report a case of 54-year-old male who developed myocardial and multiple cerebral infarction after endoscopic obliteration of gastric variceal bleeding with N-butyl-2-cyanoacrylate.
Cerebral Infarction
;
Embolism
;
Enbucrilate
;
Esophageal and Gastric Varices
;
Humans
;
Male
;
Middle Aged
9.Endovascular treatment of pancreatitis-related gastrointestinal bleeding
Gastrointestinal Intervention 2018;7(3):162-166
Hemorrhage following pancreatitis may become complicated during the disease course and with possibly fatal consequences. Radiologic findings are as follows: the presence of hematomas, hemorrhagic pseudocysts, extravasation of contrast media or the formation of arterial pseudoaneurysms. The digital subtraction angiography findings are as follows: contrast extravasation due to arterial rupture; pseudoaneurysm formation; and luminal irregularity. A pseudoaneurysm is considered to be treated as soon as detected due to its risk of rupture. Endovascular management, which includes embolization using coils, N-butyl cyanoacrylate, gelatin sponge, stents, and thrombin, is an effective option for the treatment for pancreatitis-related bleeding.
Aneurysm, False
;
Angiography, Digital Subtraction
;
Cyanoacrylates
;
Embolization, Therapeutic
;
Endovascular Procedures
;
Extravasation of Diagnostic and Therapeutic Materials
;
Gelatin
;
Hematoma
;
Hemorrhage
;
Pancreatitis
;
Phenobarbital
;
Porifera
;
Rupture
;
Stents
;
Thrombin
10.Is glue embolization safe and effective for gastrointestinal bleeding?
Shinsaku YATA ; Yasufumi OHUCHI ; Akira ADACHI ; Masayuki ENDO ; Shohei TAKASUGI ; Kazumichi TSUKAMOTO ; Kensuke MATSUMOTO ; Mika KODANI ; Jun MAKISHIMA ; Shinya FUJII
Gastrointestinal Intervention 2018;7(3):158-161
Transcatheter arterial embolization using N-butyl-2-cyanoacrylate (NBCA) for gastrointestinal arterial bleeding enables higher cessation rate and lower recurrent bleeding rate compared with conventional embolic materials including gelatin sponge, metallic coil, and polyvinyl alcohol (PVA) particle. Glue embolization is particularly effective in patients with coagulopathy. Even in the lower gastrointestinal tract, ischemic bowel complications by glue embolization are comparable to other agents. Glue embolization is also effective for arterial esophageal bleeding without any serious ischemic complications although the anatomy of the esophageal artery is complex and varied. For bleeding after abdominal surgery such as pancreaticoduodenectomy or hepatic lobectomy, interventional radiologists should be careful with indicating glue embolization because the presence of fewer collateral vessels can easily result in serious ischemic complications. Modified glue such as Glubran 2 (NBCA associated with methacryloxyfulfolane) can reduce the risk of ischemic complication due to its less thermal reaction, but the outcomes seem unsatisfactory.
Adhesives
;
Arteries
;
Cyanoacrylates
;
Embolization, Therapeutic
;
Enbucrilate
;
Gastrointestinal Hemorrhage
;
Gelatin
;
Hemorrhage
;
Humans
;
Lower Gastrointestinal Tract
;
Pancreaticoduodenectomy
;
Polyvinyl Alcohol
;
Porifera

Result Analysis
Print
Save
E-mail