1.Establishment and Preliminary Analysis of GP73 Interactome Using Proximity-dependent Labeling Technology
Mu-Yi LIU ; Chang ZHANG ; Meng-Xin YANG ; Xin-Long YAN ; Lu-Ming WAN ; Cong-Wen WEI
Progress in Biochemistry and Biophysics 2026;53(3):711-723
ObjectiveProtein-protein interactions (PPIs) are fundamental to the execution of biological functions within living cells. However, traditional biochemical methods, such as co-immunoprecipitation (Co-IP), often fail to capture transient, weak, or membrane-associated interactions due to the stringent detergent requirements for cell lysis. Proximity labeling (PL) has emerged in recent years as a transformative technology for mapping the proteomes of specific subcellular compartments and identifying dynamic interactomes in situ. Golgi protein 73 (GP73, also known as GOLPH2), a resident type II Golgi transmembrane protein, is a well-recognized clinical biomarker for liver diseases, including hepatocellular carcinoma (HCC). Despite its clinical significance, the comprehensive physiological and pathological functions of GP73 remain partially understood. This study aims to establish an APEX2-mediated proximity labeling system specifically targeting GP73 to map its interactome in a living cellular environment, thereby providing new insights into its molecular roles and regulatory mechanisms. MethodsTo achieve spatial specificity, we first constructed a stable cell line expressing a fusion protein consisting of GP73 and the engineered soybean peroxidase APEX2. The localization of the GP73-APEX2 fusion protein was validated to ensure it correctly targeted the Golgi apparatus. The proximity labeling reaction was initiated by incubating the cells with biotin-phenol (BP) for 30 min, followed by a brief (1 min) treatment with1 mmol/L hydrogen peroxide (H2O2). This catalytic reaction converts BP into highly reactive, short-lived biotin-phenoxyl radicals that covalently attach to endogenous proteins within a small labeling radius of the GP73-APEX2 enzyme. Subsequently, the cells were quenched, and biotinylated proteins were enriched using high-affinity streptavidin-coated magnetic beads. The captured “neighbor” proteins were subjected to on-bead digestion and analyzed via liquid chromatography-tandem mass spectrometry (LC-MS/MS) for high-throughput identification. Rigorous bioinformatics analysis, including Gene Ontology (GO) enrichment, Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway analysis, and protein-protein interaction network mapping, was performed to interpret the biological significance of the identified candidates. ResultsOur results demonstrate the successful establishment of a robust and sensitive APEX2-based proximity labeling system for GP73. We identified a total of 95 high-confidence interacting proteins that were significantly enriched in the GP73 proximity proteome compared to control groups. Bioinformatics analysis revealed that these interactors were predominantly associated with biological processes such as vesicular transport, protein localization, and, most notably, molecular functions related to “ribosome binding” and “translation regulation”. This suggested an unexpected role for the Golgi-resident GP73 in the cellular translation machinery. To validate these findings, we performed targeted biochemical assays which confirmed a direct interaction between GP73 and the subunits of the eukaryotic translation initiation factor 3 (eIF3) complex, specifically EIF3G and EIF3I. Furthermore, functional validation using the surface sensing of translation (SUnSET) assay—a non-radioactive method to monitor protein synthesis—revealed that the overexpression of GP73 significantly promoted global protein translation levels in the cell, whereas its depletion or inhibition resulted in reduced translation efficiency. ConclusionThis study successfully utilized APEX2-mediated proximity labeling to provide the first systematic map of GP73 interactome in living cells. Our findings uncover a novel, unconventional function of GP73 as a regulator of cellular protein translation, likely mediated through its interaction with the eIF3 complex. This discovery significantly broadens our understanding of the biological roles of GP73 beyond its traditional function in the Golgi apparatus and suggests that it may act as a bridge between Golgi-related trafficking and the protein synthesis machinery. Furthermore, the technical framework established in this study provides a valuable template for investigating other complex organelle-associated protein networks and resolving transient macromolecular interactions in various physiological and pathological contexts.
2.Multi-component Quality Consistency Evaluation of Leonuri Herba Granules Based on HPLC-DAD-CAD Multi-detector Technique and Chemometrics
Shuangyan LI ; Jun ZHANG ; Cong GUO ; Siyuan LI ; Jipeng DI ; Jiangmin SU ; An LIU ; Xiaodi KOU ; Yan LIU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(8):174-181
ObjectiveTo systematically evaluate the content differences of 4 components in Leonuri Herba granules, reveal the quality fluctuation patterns of products from the same and different manufacturers, providing scientific basis for the optimization of production process and quality control. MethodsHigh performance liquid chromatography-diode array detector-charged aerosol detector(HPLC-DAD-CAD) was employed to determine the contents of 4 components(syringic acid, leonurine hydrochloride, ferulic acid, and stachydrine hydrochloride) in samples from 19 manufacturers(53 batches, 159 boxes). Additionally, fingerprint profiles were constructed, and the fingerprint dissimilarity(PS) and relative standard deviation(RSD) of different samples from the same manufacturer were calculated. A principal component analysis(PCA) model was established with PS and the RSD values of the 4 components as variables to classify the manufacturers. Finally, samples from 5 manufacturers(M1-M5) covering three consistency groups were selected to calculate three quality consistency parameters, namely intra-batch consistency(PA), inter-batch consistency(PB), and PS. Then, PCA was performed with PA, PB, and PS of these 5 manufacturers as variables. ResultsThe average total content of the 4 index components per bag across the 19 manufacturers ranged from 41.10 mg to 97.54 mg. Among them, the content of stachydrine hydrochloride(a pharmacopoeial quality control component) was 32.46-72.70 mg per bag, all meeting the requirements of the 2025 edition of the Pharmacopoeia of the People's Republic of China, with RSD of 1.7%-17.1%. The content ranges of the other 3 components were as follows:syringic acid of 1.43-41.92 mg per bag, leonurine hydrochloride of 0.67-11.85 mg per bag, and ferulic acid of 0.11-3.81 mg per bag. Notably, leonurine hydrochloride exhibited the most significant content fluctuation among samples from the same manufacturer(RSD of 4.8%-59.2%). PCA results showed that the 19 manufacturers could be classified into 3 categories. Samples from 8 manufacturers(M2, M6, M7, M8, M10, M15, M17, M18) demonstrated relatively high consistency, five manufacturers(M3, M9, M12, M13, M14) showed moderate consistency, six manufacturers(M1, M4, M5, M11, M16, M19) exhibited low consistency. The two methods yielded consistent classification results for the 5 representative manufacturers, verifying the reliability of the proposed method. Among these, manufacturer M2 showed the best quality consistency and the highest total content of indicator components among M1-M5. ConclusionThe HPLC-DAD-CAD multi-detector hyphenation technology established in this study enables the accurate detection of 4 components in Leonuri Herba granules. Significant differences in the total content of these four components are observed among products from 19 manufacturers. The application of 2 consistency evaluation methods combined with PCA can effectively classify their consistency into 3 categories, and the classification results of the 2 methods are highly consistent. This study provides scientific basis for the process optimization and quality standard improvement of Leonuri Herba granules.
3.Multi-component Quality Consistency Evaluation of Leonuri Herba Granules Based on HPLC-DAD-CAD Multi-detector Technique and Chemometrics
Shuangyan LI ; Jun ZHANG ; Cong GUO ; Siyuan LI ; Jipeng DI ; Jiangmin SU ; An LIU ; Xiaodi KOU ; Yan LIU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(8):174-181
ObjectiveTo systematically evaluate the content differences of 4 components in Leonuri Herba granules, reveal the quality fluctuation patterns of products from the same and different manufacturers, providing scientific basis for the optimization of production process and quality control. MethodsHigh performance liquid chromatography-diode array detector-charged aerosol detector(HPLC-DAD-CAD) was employed to determine the contents of 4 components(syringic acid, leonurine hydrochloride, ferulic acid, and stachydrine hydrochloride) in samples from 19 manufacturers(53 batches, 159 boxes). Additionally, fingerprint profiles were constructed, and the fingerprint dissimilarity(PS) and relative standard deviation(RSD) of different samples from the same manufacturer were calculated. A principal component analysis(PCA) model was established with PS and the RSD values of the 4 components as variables to classify the manufacturers. Finally, samples from 5 manufacturers(M1-M5) covering three consistency groups were selected to calculate three quality consistency parameters, namely intra-batch consistency(PA), inter-batch consistency(PB), and PS. Then, PCA was performed with PA, PB, and PS of these 5 manufacturers as variables. ResultsThe average total content of the 4 index components per bag across the 19 manufacturers ranged from 41.10 mg to 97.54 mg. Among them, the content of stachydrine hydrochloride(a pharmacopoeial quality control component) was 32.46-72.70 mg per bag, all meeting the requirements of the 2025 edition of the Pharmacopoeia of the People's Republic of China, with RSD of 1.7%-17.1%. The content ranges of the other 3 components were as follows:syringic acid of 1.43-41.92 mg per bag, leonurine hydrochloride of 0.67-11.85 mg per bag, and ferulic acid of 0.11-3.81 mg per bag. Notably, leonurine hydrochloride exhibited the most significant content fluctuation among samples from the same manufacturer(RSD of 4.8%-59.2%). PCA results showed that the 19 manufacturers could be classified into 3 categories. Samples from 8 manufacturers(M2, M6, M7, M8, M10, M15, M17, M18) demonstrated relatively high consistency, five manufacturers(M3, M9, M12, M13, M14) showed moderate consistency, six manufacturers(M1, M4, M5, M11, M16, M19) exhibited low consistency. The two methods yielded consistent classification results for the 5 representative manufacturers, verifying the reliability of the proposed method. Among these, manufacturer M2 showed the best quality consistency and the highest total content of indicator components among M1-M5. ConclusionThe HPLC-DAD-CAD multi-detector hyphenation technology established in this study enables the accurate detection of 4 components in Leonuri Herba granules. Significant differences in the total content of these four components are observed among products from 19 manufacturers. The application of 2 consistency evaluation methods combined with PCA can effectively classify their consistency into 3 categories, and the classification results of the 2 methods are highly consistent. This study provides scientific basis for the process optimization and quality standard improvement of Leonuri Herba granules.
4.Curcumin extraction and preparation and optimization of curcumin nanoparticles
Yuhang WANG ; Han ZHANG ; Chaojing ZHANG ; Xurong KOU ; Tongtong JING ; Rimei LIN ; Xinyu LIU ; Shilei LOU ; Hui YAN ; Cong SUN
Chinese Journal of Tissue Engineering Research 2026;30(2):362-374
BACKGROUND:Curcumin is the main active ingredient of turmeric and has significant medicinal value in anti-tumor,anti-inflammatory,antioxidant and other aspects.However,its poor water solubility,unstable chemical properties and easy decomposition lead to difficulty in extracting curcumin and low extraction yield.Therefore,it is particularly important to optimize the curcumin extraction method.OBJECTIVE:To enhance the extraction yield and utilization value of curcumin and optimize the curcumin extraction process and curcumin nanoparticle preparation process.METHODS:Curcumin was extracted from turmeric by ethanol extraction,ultrasonic extraction,ionic liquid extraction,enzyme extraction,and ionic liquid combined with ultrasonic assisted enzyme extraction.The curcumin extraction yield was detected by high performance liquid chromatography;the best extraction method was determined,and subsequent process optimization experiments were carried out.The curcumin extraction yield was the response value with the type of ionic liquid,reaction temperature,ultrasonic time,liquid-to-solid ratio,ionic liquid concentration,and enzyme-drug mass ratio as parameters.The optimal production process of ionic liquid combined with ultrasonic assisted enzyme extraction was determined by single factor combined response surface experiment.The optimal process for preparing curcumin nanoparticles by ionic crosslinking method was determined by single factor combined response surface experiment with acetic acid concentration,chitosan to sodium tripolyphosphate mass ratio,stirring rate,curcumin mass concentration,sodium tripolyphosphate mass concentration,and chitosan mass concentration as parameters,and drug encapsulation efficiency as response value.Curcumin nanoparticles were prepared under the optimal process,and the particle size,polydispersity index,Zata potential value,drug loading,stability,hemolysis rate,and antioxidant capacity in vivo and in vitro of the nanoparticles were detected.RESULTS AND CONCLUSION:(1)Among the five extraction methods,the curcumin yield of ionic liquid combined with ultrasound-assisted enzyme extraction was the highest,and this method was selected as the curcumin extraction method for subsequent experiments.The results of single factor combined response surface experiment showed that the optimal process for curcumin extraction was:ionic liquid selected 1-hexyl-3-methylimidazolium chloride,reaction temperature 55 ℃,liquid-to-solid ratio 40 mL/g,ultrasound time 57 minutes,ionic liquid concentration 57%,enzyme-drug mass ratio 3.5:10,and the obtained turmeric extraction yield was 3.10%.The optimal preparation process of curcumin nanoparticles was:glacial acetic acid concentration 0.5%,chitosan and sodium tripolyphosphate mass ratio 5.0:1,stirring speed 150 r/min,curcumin mass concentration 2.23 mg/mL,sodium tripolyphosphate mass concentration 1.45 mg/mL,chitosan mass concentration 3.63 mg/mL,and the obtained drug encapsulation efficiency was 90.61%.(2)The drug loading of curcumin nanoparticles was(14.49±0.23)%,the average particle size was(76.95±1.65)nm,the polydispersity coefficient was 0.15±0.02,and the Zata potential value was(32.37±1.46)mV.The curcumin nanoparticles had good stability and blood compatibility,did not induce hemolysis,and had stronger antioxidant capacity in vivo and in vitro than free curcumin.(3)The results show that the process optimization not only solves the problems of low extraction yield,poor solubility,and low bioavailability of curcumin,but also enhances its antioxidant activity in vivo and in vitro.
5.Curcumin extraction and preparation and optimization of curcumin nanoparticles
Yuhang WANG ; Han ZHANG ; Chaojing ZHANG ; Xurong KOU ; Tongtong JING ; Rimei LIN ; Xinyu LIU ; Shilei LOU ; Hui YAN ; Cong SUN
Chinese Journal of Tissue Engineering Research 2026;30(2):362-374
BACKGROUND:Curcumin is the main active ingredient of turmeric and has significant medicinal value in anti-tumor,anti-inflammatory,antioxidant and other aspects.However,its poor water solubility,unstable chemical properties and easy decomposition lead to difficulty in extracting curcumin and low extraction yield.Therefore,it is particularly important to optimize the curcumin extraction method.OBJECTIVE:To enhance the extraction yield and utilization value of curcumin and optimize the curcumin extraction process and curcumin nanoparticle preparation process.METHODS:Curcumin was extracted from turmeric by ethanol extraction,ultrasonic extraction,ionic liquid extraction,enzyme extraction,and ionic liquid combined with ultrasonic assisted enzyme extraction.The curcumin extraction yield was detected by high performance liquid chromatography;the best extraction method was determined,and subsequent process optimization experiments were carried out.The curcumin extraction yield was the response value with the type of ionic liquid,reaction temperature,ultrasonic time,liquid-to-solid ratio,ionic liquid concentration,and enzyme-drug mass ratio as parameters.The optimal production process of ionic liquid combined with ultrasonic assisted enzyme extraction was determined by single factor combined response surface experiment.The optimal process for preparing curcumin nanoparticles by ionic crosslinking method was determined by single factor combined response surface experiment with acetic acid concentration,chitosan to sodium tripolyphosphate mass ratio,stirring rate,curcumin mass concentration,sodium tripolyphosphate mass concentration,and chitosan mass concentration as parameters,and drug encapsulation efficiency as response value.Curcumin nanoparticles were prepared under the optimal process,and the particle size,polydispersity index,Zata potential value,drug loading,stability,hemolysis rate,and antioxidant capacity in vivo and in vitro of the nanoparticles were detected.RESULTS AND CONCLUSION:(1)Among the five extraction methods,the curcumin yield of ionic liquid combined with ultrasound-assisted enzyme extraction was the highest,and this method was selected as the curcumin extraction method for subsequent experiments.The results of single factor combined response surface experiment showed that the optimal process for curcumin extraction was:ionic liquid selected 1-hexyl-3-methylimidazolium chloride,reaction temperature 55 ℃,liquid-to-solid ratio 40 mL/g,ultrasound time 57 minutes,ionic liquid concentration 57%,enzyme-drug mass ratio 3.5:10,and the obtained turmeric extraction yield was 3.10%.The optimal preparation process of curcumin nanoparticles was:glacial acetic acid concentration 0.5%,chitosan and sodium tripolyphosphate mass ratio 5.0:1,stirring speed 150 r/min,curcumin mass concentration 2.23 mg/mL,sodium tripolyphosphate mass concentration 1.45 mg/mL,chitosan mass concentration 3.63 mg/mL,and the obtained drug encapsulation efficiency was 90.61%.(2)The drug loading of curcumin nanoparticles was(14.49±0.23)%,the average particle size was(76.95±1.65)nm,the polydispersity coefficient was 0.15±0.02,and the Zata potential value was(32.37±1.46)mV.The curcumin nanoparticles had good stability and blood compatibility,did not induce hemolysis,and had stronger antioxidant capacity in vivo and in vitro than free curcumin.(3)The results show that the process optimization not only solves the problems of low extraction yield,poor solubility,and low bioavailability of curcumin,but also enhances its antioxidant activity in vivo and in vitro.
6.Identification of radiation-sensitive genes using machine learning algorithms
Yizhe GAO ; Tianjing CAI ; Shuang LI ; Xuelei TIAN ; Cong XI ; Juan YAN ; Qingjie LIU
Chinese Journal of Radiological Health 2026;35(2):240-245
Objective To establish an analytical strategy covering multi-dataset processing, recursive feature elimination (RFE) screening and multi-model evaluation based on multiple machine learning algorithms, so as to screen radiation-sensitive genes and verify the feasibility of the evaluation strategy. Methods Qualified radiation transcriptome datasets were retrieved from public gene expression databases. Following standardized data preprocessing and feature preselection, 13 machine learning algorithms were adopted to construct models. The performance of each model was compared and validated in independent datasets. Results A total of 38 eligible datasets were included. Sixteen differentially expressed genes unreported in existing literature were screened out, among which ugcrhl, pdcl3, mct4, h2-g2 and fam120aos were correlated with radiation phenotypes. Ensemble learning algorithms including random forest and gradient boosting exhibited the optimal comprehensive performance. Independent dataset verification confirmed that the screened genes overlapped with known radiation-sensitive genes, and the model performance was consistent with the findings. Conclusion The machine learning strategy constructed in this study can effectively explore potential radiation-sensitive genes, and provides methodological support for subsequent relevant studies.
7.Identification of radiation-sensitive genes using machine learning algorithms
Yizhe GAO ; Tianjing CAI ; Shuang LI ; Xuelei TIAN ; Cong XI ; Juan YAN ; Qingjie LIU
Chinese Journal of Radiological Health 2026;35(2):240-245
Objective To establish an analytical strategy covering multi-dataset processing, recursive feature elimination (RFE) screening and multi-model evaluation based on multiple machine learning algorithms, so as to screen radiation-sensitive genes and verify the feasibility of the evaluation strategy. Methods Qualified radiation transcriptome datasets were retrieved from public gene expression databases. Following standardized data preprocessing and feature preselection, 13 machine learning algorithms were adopted to construct models. The performance of each model was compared and validated in independent datasets. Results A total of 38 eligible datasets were included. Sixteen differentially expressed genes unreported in existing literature were screened out, among which ugcrhl, pdcl3, mct4, h2-g2 and fam120aos were correlated with radiation phenotypes. Ensemble learning algorithms including random forest and gradient boosting exhibited the optimal comprehensive performance. Independent dataset verification confirmed that the screened genes overlapped with known radiation-sensitive genes, and the model performance was consistent with the findings. Conclusion The machine learning strategy constructed in this study can effectively explore potential radiation-sensitive genes, and provides methodological support for subsequent relevant studies.
8.Identification of radiation-sensitive genes using machine learning algorithms
Yizhe GAO ; Tianjing CAI ; Shuang LI ; Xuelei TIAN ; Cong XI ; Juan YAN ; Qingjie LIU
Chinese Journal of Radiological Health 2026;35(2):240-245
Objective To establish an analytical strategy covering multi-dataset processing, recursive feature elimination (RFE) screening and multi-model evaluation based on multiple machine learning algorithms, so as to screen radiation-sensitive genes and verify the feasibility of the evaluation strategy. Methods Qualified radiation transcriptome datasets were retrieved from public gene expression databases. Following standardized data preprocessing and feature preselection, 13 machine learning algorithms were adopted to construct models. The performance of each model was compared and validated in independent datasets. Results A total of 38 eligible datasets were included. Sixteen differentially expressed genes unreported in existing literature were screened out, among which ugcrhl, pdcl3, mct4, h2-g2 and fam120aos were correlated with radiation phenotypes. Ensemble learning algorithms including random forest and gradient boosting exhibited the optimal comprehensive performance. Independent dataset verification confirmed that the screened genes overlapped with known radiation-sensitive genes, and the model performance was consistent with the findings. Conclusion The machine learning strategy constructed in this study can effectively explore potential radiation-sensitive genes, and provides methodological support for subsequent relevant studies.
9.A cisplatin prodrug-based self-assembling ozone delivery nanosystem sensitizes radiotherapy in triple-negative breast cancer.
Tianyue XU ; Dan ZHENG ; Meixu CHEN ; Linlin SONG ; Zhihui LIU ; Yan CHENG ; Yujie ZHAO ; Liwen HUANG ; Yixuan LI ; Zhankun YANG ; Cong LI ; Biao DONG ; Jing JING ; Hubing SHI
Acta Pharmaceutica Sinica B 2025;15(5):2703-2722
Lacking therapeutic targets highlights the crucial roles of chemotherapy and radiotherapy in the clinical management of triple-negative breast cancer (TNBC). To relieve the side effects of the chemoradiotherapy combination regimen, we design and develop a self-assembled micelle nanosystem consisting of perfluorocarbon chain-modified cisplatin prodrug. By incorporating perfluorodecalin, this nanosystem can effectively carry ozone and promote irradiation-derived reactive oxygen species (ROS) production. By leveraging the perfluorocarbon sidechain, the nanosystem exhibits efficient internalization by TNBC cells and effectively escapes from lysosomal entrapment. Under X-ray irradiation, ozone-generated ROS disrupts the intracellular redox balance, thereby facilitating the release of cisplatin in a reduction-responsive manner mediated by reduced glutathione. Moreover, oxygen derived from ozone decomposition enhances the efficacy of radiotherapy by alleviating tumor hypoxia. Notably, the combination of irradiation with ozone-loaded cisplatin prodrug nano system synergistically prompts antitumor efficacy and reduces cellular/systemic toxicity in vitro and in vivo. Furthermore, the combo regimen remodels the tumor microenvironment into an immune-favored state by triggering immunogenic cell death and relieving hypoxia, which provides a promising foundation for a combination regimen of immunotherapy. In conclusion, our nanosystem presents a novel strategy for integrating chemotherapy and radiotherapy to optimize the efficacy and safety of TNBC clinical treatment.
10.Effectiveness and safety of augmentative plating technique in managing nonunion following intramedullary nailing of long bones in the lower extremity: A systematic review and meta-analysis.
Cong-Xiao FU ; Hao GAO ; Jun REN ; Hu WANG ; Shuai-Kun LU ; Guo-Liang WANG ; Zhen-Feng ZHU ; Yun-Yan LIU ; Wen LUO ; Yong ZHANG ; Yun-Fei ZHANG
Chinese Journal of Traumatology 2025;28(3):164-174
PURPOSE:
To methodically assess the effectiveness of augmentative plating (AP) and exchange nailing (EN) in managing nonunion following intramedullary nailing for long bone fractures of the lower extremity.
METHODS:
PubMed, EMBASE, Web of Science, and the Cochrane Library were searched to gather clinical studies regarding the use of AP and EN techniques in the treatment of nonunion following intramedullary nailing of lower extremity long bones. The search was conducted up until May 2023. The original studies underwent an independent assessment of their quality, a process conducted utilizing the Newcastle-Ottawa scale. Data were retrieved from these studies, and meta-analysis was executed utilizing Review Manager 5.3.
RESULTS:
This meta-analysis included 8 studies involving 661 participants, with 305 in the AP group and 356 in the EN group. The results of the meta-analysis demonstrated that the AP group exhibited a higher rate of union (odds ratio: 8.61, 95% confidence intervals (CI): 4.12 - 17.99, p < 0.001), shorter union time (standardized mean difference (SMD): -1.08, 95% CI: -1.79 - -0.37, p = 0.003), reduced duration of the surgical procedure (SMD: -0.56, 95% CI: -0.93 - -0.19, p = 0.003), less bleeding (SMD: -1.5, 95% CI: -2.81 - -0.18, p = 0.03), and a lower incidence of complications (relative risk: -0.17, 95% CI: -0.27 - -0.06, p = 0.001). In the subgroup analysis, the time for union in the AP group in nonisthmal and isthmal nonunion of lower extremity long bones was shorter compared to the EN group (nonisthmal SMD: -1.94, 95% CI: -3.28 - -0.61, p < 0.001; isthmal SMD: -1.08, 95% CI: -1.64 - -0.52, p = 0.002).
CONCLUSION
In the treatment of nonunion in diaphyseal fractures of the long bones in the lower extremity, the AP approach is superior to EN, both intraoperatively (with reduced duration of the surgical procedure and diminished blood loss) and postoperatively (with an elevated union rate, shorter union time, and lower incidence of complications). Specifically, in the management of nonunion of lower extremity long bones with non-isthmal and isthmal intramedullary nails, AP demonstrated shorter union time in comparison to EN.
Humans
;
Bone Nails/adverse effects*
;
Bone Plates/adverse effects*
;
Femoral Fractures/surgery*
;
Fracture Fixation, Intramedullary/methods*
;
Fractures, Ununited/surgery*
;
Lower Extremity/injuries*

Result Analysis
Print
Save
E-mail