1.Multi-component Quality Consistency Evaluation of Leonuri Herba Granules Based on HPLC-DAD-CAD Multi-detector Technique and Chemometrics
Shuangyan LI ; Jun ZHANG ; Cong GUO ; Siyuan LI ; Jipeng DI ; Jiangmin SU ; An LIU ; Xiaodi KOU ; Yan LIU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(8):174-181
ObjectiveTo systematically evaluate the content differences of 4 components in Leonuri Herba granules, reveal the quality fluctuation patterns of products from the same and different manufacturers, providing scientific basis for the optimization of production process and quality control. MethodsHigh performance liquid chromatography-diode array detector-charged aerosol detector(HPLC-DAD-CAD) was employed to determine the contents of 4 components(syringic acid, leonurine hydrochloride, ferulic acid, and stachydrine hydrochloride) in samples from 19 manufacturers(53 batches, 159 boxes). Additionally, fingerprint profiles were constructed, and the fingerprint dissimilarity(PS) and relative standard deviation(RSD) of different samples from the same manufacturer were calculated. A principal component analysis(PCA) model was established with PS and the RSD values of the 4 components as variables to classify the manufacturers. Finally, samples from 5 manufacturers(M1-M5) covering three consistency groups were selected to calculate three quality consistency parameters, namely intra-batch consistency(PA), inter-batch consistency(PB), and PS. Then, PCA was performed with PA, PB, and PS of these 5 manufacturers as variables. ResultsThe average total content of the 4 index components per bag across the 19 manufacturers ranged from 41.10 mg to 97.54 mg. Among them, the content of stachydrine hydrochloride(a pharmacopoeial quality control component) was 32.46-72.70 mg per bag, all meeting the requirements of the 2025 edition of the Pharmacopoeia of the People's Republic of China, with RSD of 1.7%-17.1%. The content ranges of the other 3 components were as follows:syringic acid of 1.43-41.92 mg per bag, leonurine hydrochloride of 0.67-11.85 mg per bag, and ferulic acid of 0.11-3.81 mg per bag. Notably, leonurine hydrochloride exhibited the most significant content fluctuation among samples from the same manufacturer(RSD of 4.8%-59.2%). PCA results showed that the 19 manufacturers could be classified into 3 categories. Samples from 8 manufacturers(M2, M6, M7, M8, M10, M15, M17, M18) demonstrated relatively high consistency, five manufacturers(M3, M9, M12, M13, M14) showed moderate consistency, six manufacturers(M1, M4, M5, M11, M16, M19) exhibited low consistency. The two methods yielded consistent classification results for the 5 representative manufacturers, verifying the reliability of the proposed method. Among these, manufacturer M2 showed the best quality consistency and the highest total content of indicator components among M1-M5. ConclusionThe HPLC-DAD-CAD multi-detector hyphenation technology established in this study enables the accurate detection of 4 components in Leonuri Herba granules. Significant differences in the total content of these four components are observed among products from 19 manufacturers. The application of 2 consistency evaluation methods combined with PCA can effectively classify their consistency into 3 categories, and the classification results of the 2 methods are highly consistent. This study provides scientific basis for the process optimization and quality standard improvement of Leonuri Herba granules.
2.Multi-component Quality Consistency Evaluation of Leonuri Herba Granules Based on HPLC-DAD-CAD Multi-detector Technique and Chemometrics
Shuangyan LI ; Jun ZHANG ; Cong GUO ; Siyuan LI ; Jipeng DI ; Jiangmin SU ; An LIU ; Xiaodi KOU ; Yan LIU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(8):174-181
ObjectiveTo systematically evaluate the content differences of 4 components in Leonuri Herba granules, reveal the quality fluctuation patterns of products from the same and different manufacturers, providing scientific basis for the optimization of production process and quality control. MethodsHigh performance liquid chromatography-diode array detector-charged aerosol detector(HPLC-DAD-CAD) was employed to determine the contents of 4 components(syringic acid, leonurine hydrochloride, ferulic acid, and stachydrine hydrochloride) in samples from 19 manufacturers(53 batches, 159 boxes). Additionally, fingerprint profiles were constructed, and the fingerprint dissimilarity(PS) and relative standard deviation(RSD) of different samples from the same manufacturer were calculated. A principal component analysis(PCA) model was established with PS and the RSD values of the 4 components as variables to classify the manufacturers. Finally, samples from 5 manufacturers(M1-M5) covering three consistency groups were selected to calculate three quality consistency parameters, namely intra-batch consistency(PA), inter-batch consistency(PB), and PS. Then, PCA was performed with PA, PB, and PS of these 5 manufacturers as variables. ResultsThe average total content of the 4 index components per bag across the 19 manufacturers ranged from 41.10 mg to 97.54 mg. Among them, the content of stachydrine hydrochloride(a pharmacopoeial quality control component) was 32.46-72.70 mg per bag, all meeting the requirements of the 2025 edition of the Pharmacopoeia of the People's Republic of China, with RSD of 1.7%-17.1%. The content ranges of the other 3 components were as follows:syringic acid of 1.43-41.92 mg per bag, leonurine hydrochloride of 0.67-11.85 mg per bag, and ferulic acid of 0.11-3.81 mg per bag. Notably, leonurine hydrochloride exhibited the most significant content fluctuation among samples from the same manufacturer(RSD of 4.8%-59.2%). PCA results showed that the 19 manufacturers could be classified into 3 categories. Samples from 8 manufacturers(M2, M6, M7, M8, M10, M15, M17, M18) demonstrated relatively high consistency, five manufacturers(M3, M9, M12, M13, M14) showed moderate consistency, six manufacturers(M1, M4, M5, M11, M16, M19) exhibited low consistency. The two methods yielded consistent classification results for the 5 representative manufacturers, verifying the reliability of the proposed method. Among these, manufacturer M2 showed the best quality consistency and the highest total content of indicator components among M1-M5. ConclusionThe HPLC-DAD-CAD multi-detector hyphenation technology established in this study enables the accurate detection of 4 components in Leonuri Herba granules. Significant differences in the total content of these four components are observed among products from 19 manufacturers. The application of 2 consistency evaluation methods combined with PCA can effectively classify their consistency into 3 categories, and the classification results of the 2 methods are highly consistent. This study provides scientific basis for the process optimization and quality standard improvement of Leonuri Herba granules.
3.Establishment and Preliminary Analysis of GP73 Interactome Using Proximity-dependent Labeling Technology
Mu-Yi LIU ; Chang ZHANG ; Meng-Xin YANG ; Xin-Long YAN ; Lu-Ming WAN ; Cong-Wen WEI
Progress in Biochemistry and Biophysics 2026;53(3):711-723
ObjectiveProtein-protein interactions (PPIs) are fundamental to the execution of biological functions within living cells. However, traditional biochemical methods, such as co-immunoprecipitation (Co-IP), often fail to capture transient, weak, or membrane-associated interactions due to the stringent detergent requirements for cell lysis. Proximity labeling (PL) has emerged in recent years as a transformative technology for mapping the proteomes of specific subcellular compartments and identifying dynamic interactomes in situ. Golgi protein 73 (GP73, also known as GOLPH2), a resident type II Golgi transmembrane protein, is a well-recognized clinical biomarker for liver diseases, including hepatocellular carcinoma (HCC). Despite its clinical significance, the comprehensive physiological and pathological functions of GP73 remain partially understood. This study aims to establish an APEX2-mediated proximity labeling system specifically targeting GP73 to map its interactome in a living cellular environment, thereby providing new insights into its molecular roles and regulatory mechanisms. MethodsTo achieve spatial specificity, we first constructed a stable cell line expressing a fusion protein consisting of GP73 and the engineered soybean peroxidase APEX2. The localization of the GP73-APEX2 fusion protein was validated to ensure it correctly targeted the Golgi apparatus. The proximity labeling reaction was initiated by incubating the cells with biotin-phenol (BP) for 30 min, followed by a brief (1 min) treatment with1 mmol/L hydrogen peroxide (H2O2). This catalytic reaction converts BP into highly reactive, short-lived biotin-phenoxyl radicals that covalently attach to endogenous proteins within a small labeling radius of the GP73-APEX2 enzyme. Subsequently, the cells were quenched, and biotinylated proteins were enriched using high-affinity streptavidin-coated magnetic beads. The captured “neighbor” proteins were subjected to on-bead digestion and analyzed via liquid chromatography-tandem mass spectrometry (LC-MS/MS) for high-throughput identification. Rigorous bioinformatics analysis, including Gene Ontology (GO) enrichment, Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway analysis, and protein-protein interaction network mapping, was performed to interpret the biological significance of the identified candidates. ResultsOur results demonstrate the successful establishment of a robust and sensitive APEX2-based proximity labeling system for GP73. We identified a total of 95 high-confidence interacting proteins that were significantly enriched in the GP73 proximity proteome compared to control groups. Bioinformatics analysis revealed that these interactors were predominantly associated with biological processes such as vesicular transport, protein localization, and, most notably, molecular functions related to “ribosome binding” and “translation regulation”. This suggested an unexpected role for the Golgi-resident GP73 in the cellular translation machinery. To validate these findings, we performed targeted biochemical assays which confirmed a direct interaction between GP73 and the subunits of the eukaryotic translation initiation factor 3 (eIF3) complex, specifically EIF3G and EIF3I. Furthermore, functional validation using the surface sensing of translation (SUnSET) assay—a non-radioactive method to monitor protein synthesis—revealed that the overexpression of GP73 significantly promoted global protein translation levels in the cell, whereas its depletion or inhibition resulted in reduced translation efficiency. ConclusionThis study successfully utilized APEX2-mediated proximity labeling to provide the first systematic map of GP73 interactome in living cells. Our findings uncover a novel, unconventional function of GP73 as a regulator of cellular protein translation, likely mediated through its interaction with the eIF3 complex. This discovery significantly broadens our understanding of the biological roles of GP73 beyond its traditional function in the Golgi apparatus and suggests that it may act as a bridge between Golgi-related trafficking and the protein synthesis machinery. Furthermore, the technical framework established in this study provides a valuable template for investigating other complex organelle-associated protein networks and resolving transient macromolecular interactions in various physiological and pathological contexts.
4.Curcumin extraction and preparation and optimization of curcumin nanoparticles
Yuhang WANG ; Han ZHANG ; Chaojing ZHANG ; Xurong KOU ; Tongtong JING ; Rimei LIN ; Xinyu LIU ; Shilei LOU ; Hui YAN ; Cong SUN
Chinese Journal of Tissue Engineering Research 2026;30(2):362-374
BACKGROUND:Curcumin is the main active ingredient of turmeric and has significant medicinal value in anti-tumor,anti-inflammatory,antioxidant and other aspects.However,its poor water solubility,unstable chemical properties and easy decomposition lead to difficulty in extracting curcumin and low extraction yield.Therefore,it is particularly important to optimize the curcumin extraction method.OBJECTIVE:To enhance the extraction yield and utilization value of curcumin and optimize the curcumin extraction process and curcumin nanoparticle preparation process.METHODS:Curcumin was extracted from turmeric by ethanol extraction,ultrasonic extraction,ionic liquid extraction,enzyme extraction,and ionic liquid combined with ultrasonic assisted enzyme extraction.The curcumin extraction yield was detected by high performance liquid chromatography;the best extraction method was determined,and subsequent process optimization experiments were carried out.The curcumin extraction yield was the response value with the type of ionic liquid,reaction temperature,ultrasonic time,liquid-to-solid ratio,ionic liquid concentration,and enzyme-drug mass ratio as parameters.The optimal production process of ionic liquid combined with ultrasonic assisted enzyme extraction was determined by single factor combined response surface experiment.The optimal process for preparing curcumin nanoparticles by ionic crosslinking method was determined by single factor combined response surface experiment with acetic acid concentration,chitosan to sodium tripolyphosphate mass ratio,stirring rate,curcumin mass concentration,sodium tripolyphosphate mass concentration,and chitosan mass concentration as parameters,and drug encapsulation efficiency as response value.Curcumin nanoparticles were prepared under the optimal process,and the particle size,polydispersity index,Zata potential value,drug loading,stability,hemolysis rate,and antioxidant capacity in vivo and in vitro of the nanoparticles were detected.RESULTS AND CONCLUSION:(1)Among the five extraction methods,the curcumin yield of ionic liquid combined with ultrasound-assisted enzyme extraction was the highest,and this method was selected as the curcumin extraction method for subsequent experiments.The results of single factor combined response surface experiment showed that the optimal process for curcumin extraction was:ionic liquid selected 1-hexyl-3-methylimidazolium chloride,reaction temperature 55 ℃,liquid-to-solid ratio 40 mL/g,ultrasound time 57 minutes,ionic liquid concentration 57%,enzyme-drug mass ratio 3.5:10,and the obtained turmeric extraction yield was 3.10%.The optimal preparation process of curcumin nanoparticles was:glacial acetic acid concentration 0.5%,chitosan and sodium tripolyphosphate mass ratio 5.0:1,stirring speed 150 r/min,curcumin mass concentration 2.23 mg/mL,sodium tripolyphosphate mass concentration 1.45 mg/mL,chitosan mass concentration 3.63 mg/mL,and the obtained drug encapsulation efficiency was 90.61%.(2)The drug loading of curcumin nanoparticles was(14.49±0.23)%,the average particle size was(76.95±1.65)nm,the polydispersity coefficient was 0.15±0.02,and the Zata potential value was(32.37±1.46)mV.The curcumin nanoparticles had good stability and blood compatibility,did not induce hemolysis,and had stronger antioxidant capacity in vivo and in vitro than free curcumin.(3)The results show that the process optimization not only solves the problems of low extraction yield,poor solubility,and low bioavailability of curcumin,but also enhances its antioxidant activity in vivo and in vitro.
5.Curcumin extraction and preparation and optimization of curcumin nanoparticles
Yuhang WANG ; Han ZHANG ; Chaojing ZHANG ; Xurong KOU ; Tongtong JING ; Rimei LIN ; Xinyu LIU ; Shilei LOU ; Hui YAN ; Cong SUN
Chinese Journal of Tissue Engineering Research 2026;30(2):362-374
BACKGROUND:Curcumin is the main active ingredient of turmeric and has significant medicinal value in anti-tumor,anti-inflammatory,antioxidant and other aspects.However,its poor water solubility,unstable chemical properties and easy decomposition lead to difficulty in extracting curcumin and low extraction yield.Therefore,it is particularly important to optimize the curcumin extraction method.OBJECTIVE:To enhance the extraction yield and utilization value of curcumin and optimize the curcumin extraction process and curcumin nanoparticle preparation process.METHODS:Curcumin was extracted from turmeric by ethanol extraction,ultrasonic extraction,ionic liquid extraction,enzyme extraction,and ionic liquid combined with ultrasonic assisted enzyme extraction.The curcumin extraction yield was detected by high performance liquid chromatography;the best extraction method was determined,and subsequent process optimization experiments were carried out.The curcumin extraction yield was the response value with the type of ionic liquid,reaction temperature,ultrasonic time,liquid-to-solid ratio,ionic liquid concentration,and enzyme-drug mass ratio as parameters.The optimal production process of ionic liquid combined with ultrasonic assisted enzyme extraction was determined by single factor combined response surface experiment.The optimal process for preparing curcumin nanoparticles by ionic crosslinking method was determined by single factor combined response surface experiment with acetic acid concentration,chitosan to sodium tripolyphosphate mass ratio,stirring rate,curcumin mass concentration,sodium tripolyphosphate mass concentration,and chitosan mass concentration as parameters,and drug encapsulation efficiency as response value.Curcumin nanoparticles were prepared under the optimal process,and the particle size,polydispersity index,Zata potential value,drug loading,stability,hemolysis rate,and antioxidant capacity in vivo and in vitro of the nanoparticles were detected.RESULTS AND CONCLUSION:(1)Among the five extraction methods,the curcumin yield of ionic liquid combined with ultrasound-assisted enzyme extraction was the highest,and this method was selected as the curcumin extraction method for subsequent experiments.The results of single factor combined response surface experiment showed that the optimal process for curcumin extraction was:ionic liquid selected 1-hexyl-3-methylimidazolium chloride,reaction temperature 55 ℃,liquid-to-solid ratio 40 mL/g,ultrasound time 57 minutes,ionic liquid concentration 57%,enzyme-drug mass ratio 3.5:10,and the obtained turmeric extraction yield was 3.10%.The optimal preparation process of curcumin nanoparticles was:glacial acetic acid concentration 0.5%,chitosan and sodium tripolyphosphate mass ratio 5.0:1,stirring speed 150 r/min,curcumin mass concentration 2.23 mg/mL,sodium tripolyphosphate mass concentration 1.45 mg/mL,chitosan mass concentration 3.63 mg/mL,and the obtained drug encapsulation efficiency was 90.61%.(2)The drug loading of curcumin nanoparticles was(14.49±0.23)%,the average particle size was(76.95±1.65)nm,the polydispersity coefficient was 0.15±0.02,and the Zata potential value was(32.37±1.46)mV.The curcumin nanoparticles had good stability and blood compatibility,did not induce hemolysis,and had stronger antioxidant capacity in vivo and in vitro than free curcumin.(3)The results show that the process optimization not only solves the problems of low extraction yield,poor solubility,and low bioavailability of curcumin,but also enhances its antioxidant activity in vivo and in vitro.
6.Identification of radiation-sensitive genes using machine learning algorithms
Yizhe GAO ; Tianjing CAI ; Shuang LI ; Xuelei TIAN ; Cong XI ; Juan YAN ; Qingjie LIU
Chinese Journal of Radiological Health 2026;35(2):240-245
Objective To establish an analytical strategy covering multi-dataset processing, recursive feature elimination (RFE) screening and multi-model evaluation based on multiple machine learning algorithms, so as to screen radiation-sensitive genes and verify the feasibility of the evaluation strategy. Methods Qualified radiation transcriptome datasets were retrieved from public gene expression databases. Following standardized data preprocessing and feature preselection, 13 machine learning algorithms were adopted to construct models. The performance of each model was compared and validated in independent datasets. Results A total of 38 eligible datasets were included. Sixteen differentially expressed genes unreported in existing literature were screened out, among which ugcrhl, pdcl3, mct4, h2-g2 and fam120aos were correlated with radiation phenotypes. Ensemble learning algorithms including random forest and gradient boosting exhibited the optimal comprehensive performance. Independent dataset verification confirmed that the screened genes overlapped with known radiation-sensitive genes, and the model performance was consistent with the findings. Conclusion The machine learning strategy constructed in this study can effectively explore potential radiation-sensitive genes, and provides methodological support for subsequent relevant studies.
7.Identification of radiation-sensitive genes using machine learning algorithms
Yizhe GAO ; Tianjing CAI ; Shuang LI ; Xuelei TIAN ; Cong XI ; Juan YAN ; Qingjie LIU
Chinese Journal of Radiological Health 2026;35(2):240-245
Objective To establish an analytical strategy covering multi-dataset processing, recursive feature elimination (RFE) screening and multi-model evaluation based on multiple machine learning algorithms, so as to screen radiation-sensitive genes and verify the feasibility of the evaluation strategy. Methods Qualified radiation transcriptome datasets were retrieved from public gene expression databases. Following standardized data preprocessing and feature preselection, 13 machine learning algorithms were adopted to construct models. The performance of each model was compared and validated in independent datasets. Results A total of 38 eligible datasets were included. Sixteen differentially expressed genes unreported in existing literature were screened out, among which ugcrhl, pdcl3, mct4, h2-g2 and fam120aos were correlated with radiation phenotypes. Ensemble learning algorithms including random forest and gradient boosting exhibited the optimal comprehensive performance. Independent dataset verification confirmed that the screened genes overlapped with known radiation-sensitive genes, and the model performance was consistent with the findings. Conclusion The machine learning strategy constructed in this study can effectively explore potential radiation-sensitive genes, and provides methodological support for subsequent relevant studies.
8.Identification of radiation-sensitive genes using machine learning algorithms
Yizhe GAO ; Tianjing CAI ; Shuang LI ; Xuelei TIAN ; Cong XI ; Juan YAN ; Qingjie LIU
Chinese Journal of Radiological Health 2026;35(2):240-245
Objective To establish an analytical strategy covering multi-dataset processing, recursive feature elimination (RFE) screening and multi-model evaluation based on multiple machine learning algorithms, so as to screen radiation-sensitive genes and verify the feasibility of the evaluation strategy. Methods Qualified radiation transcriptome datasets were retrieved from public gene expression databases. Following standardized data preprocessing and feature preselection, 13 machine learning algorithms were adopted to construct models. The performance of each model was compared and validated in independent datasets. Results A total of 38 eligible datasets were included. Sixteen differentially expressed genes unreported in existing literature were screened out, among which ugcrhl, pdcl3, mct4, h2-g2 and fam120aos were correlated with radiation phenotypes. Ensemble learning algorithms including random forest and gradient boosting exhibited the optimal comprehensive performance. Independent dataset verification confirmed that the screened genes overlapped with known radiation-sensitive genes, and the model performance was consistent with the findings. Conclusion The machine learning strategy constructed in this study can effectively explore potential radiation-sensitive genes, and provides methodological support for subsequent relevant studies.
9.A Multi-dimensional Indicator-based Approach for Quality Evaluation of Chinese Patent Medicines
Shuangyan LI ; Siyuan LI ; Sha CHEN ; Yue GUO ; Jun ZHANG ; Cong GUO ; Yan LIU ; An LIU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(19):229-237
Chinese patent medicines are the core preparations for disease prevention and treatment in clinical traditional Chinese medicine (TCM). Their quality is the key to ensuring safe and effective medication and promoting the high-quality development of the TCM industry. At present, the quality evaluation of Chinese patent medicines faces prominent problems, such as inadequate control of quality consistency, over-reliance on single indicators, one-sided evaluation dimensions, unstable statistical methods, and poor implementability of research findings. These defects lead to insufficient scientificity of evaluation results, making it difficult to support the implementation of policies including centralized procurement, high quality, and favorable prices for Chinese patent medicines. According to the core requirements of quality evaluation for Chinese patent medicines, this study established a four-dimensional comprehensive evaluation system encompassing consistency index(CI), content index(MI), effect index(EI), and preparation index(PI). All evaluation indicators were normalized to achieve horizontal comparability. Meanwhile, an improved radar chart was introduced to realize the visualization of evaluation results. This method can systematically integrate four types of core quality attributes: Quality consistency, component content, biological activity, and preparation characteristics. It can effectively distinguish quality differences among products of the same specification from different manufacturers. The evaluation results are unique, stable, and not affected by the addition or reduction of samples, which takes scientificity, objectivity, and operability into account. This method can provide scientific and technical support for screening high-quality Chinese patent medicines and implementing policies of centralized procurement, high quality, and favorable prices. Moreover, it has important practical significance for improving the quality evaluation system of Chinese patent medicines and advancing the standard and modern development of TCM.
10.Emodin Alleviating Lung Injury in Stroke Associated Pneumonia Rats through Regulating JAK2/STAT3 Signaling Pathway
Na LI ; Lan ZHANG ; Yan QIN ; Yawei LIU ; Yizi ZHANG ; Lei SONG ; Cong FU
Journal of Guangzhou University of Traditional Chinese Medicine 2025;42(1):191-197
Objective To observe the effect of emodin on lung injury in rats with stroke associated pneumonia(SAP)through regulating Janus kinase 2(JAK2)/signal transducer and activators of transcription 3(STAT3)signaling pathway.Methods The SAP rat model was established by modified thread embolization method combined with intratracheal injection of Pseudomonas aeruginosa method.The successfully modeled rats were randomly divided into model group,emodin low-and high-dose groups and emodin high-dose+coumermycin(JAK2 activator)group,with 12 rats in each group,and another 12 SD rats were selected as the sham-operated group.After the intervention,the partial pressure of arterial blood gas indexes such as carbon dioxide(PaCO2)and partial pressure of oxygen(PaO2)were measured,the ratio of lung wet/dry mass(W/D)was determined,the inflammatory cell count in the bronchoalveolar lavage fluid(BALF)was detected,the histopathological feature in the lung tissues was observed by hematoxylin-eosin(HE)staining and the pathological injury was scored,enzyme-linked immunosorbent assay(ELISA)was used to detect myeloperoxidase(MPO)activity in the lung tissues and interleukin 6(IL-6)and cyclooxygenase 2(COX-2)levels in BALF and serum,and Western Blot was used to detect the expression of JAK2/STAT3 pathway key proteins in lung tissues.Results Compared with the sham-operated group,the model group rats showed that more obvious pathological injury in lung tissues was seen,and PaCO2 value,ratio of lung W/D,white blood cell count and eosinophils count in BALF,pathological injury score,MPO activity in lung tissues,IL-6 and COX-2 levels in BALF and serum,and ratios of p-JAK2/JAK2 and p-STAT3/STAT3 in lung tissues were significantly increased,and PaO2 value was significantly decreased,the differences being statistically significant(P<0.05);compared with the model group,the emodin low-and high-dose groups rats showed that the pathological injury in lung tissues was reduced,PaCO2 value,ratio of lung W/D,white blood cell count and eosinophils count in BALF,pathological injury score,MPO activity in lung tissues,IL-6 and COX-2 levels in BALF and serum,and ratios of p-JAK2/JAK2 and p-STAT3/STAT3 in lung tissues were all decreased,and PaO2 value was increased,the differences being statistically significant(P<0.05),and the improvement effect was more stronger in high-dose emodin group;coumermycin attenuated the improvement effect of emodin on the above various indexes in the model rats.Conclusion Emodin can reduce the inflammation levels in SAP rats through inhibiting the activation of JAK2/STAT3 signaling pathway,thus reducing the lung tissue damage and improving the lung function of rats.

Result Analysis
Print
Save
E-mail