1.Mechanism of drug-containing serum of Dianxianqing granules in inhibiting microglial ferroptosis
Guangkun FAN ; Yue QI ; Jixian WANG ; Wei CHEN ; Chunpeng XIA ; Yihang WANG ; Yue ZHAO ; Yang AN
China Pharmacy 2026;37(3):317-323
OBJECTIVE To explore the potential mechanism by which drug-containing serum of Dianxianqing granules (DXQ) inhibits microglial ferroptosis. METHODS Male SD rats were given normal saline and Dianxianqing granules solution via intragastric administration to prepare normal serum and DXQ, respectively. Mice microglia BV2 cells were collected and successfully transfected with a negative control small interfering RNA (si-NC), and then they were included in the si-NC group and cultured under normal conditions. Cells successfully transfected with small interfering RNA targeting glutathione peroxidase 4 (GPX4) (si-GPX4) were divided into the si-GPX4 group, the CsA group (treated with 1 μmol/L cyclosporine A), and the DXQ- L, DXQ-M and DXQ-H groups (treated with 5%, 7% and 10% DXQ, respectively). These groups were subsequently treated with their corresponding drug solutions and ferroptosis inducer Erastin (10 μmol/L). The intracellular levels of total iron ions, glutathione (GSH), reactive oxygen species (ROS), and the expression of mitochondrial superoxide were determined in each group after 48 h of treatment. Additionally, mitochondrial membrane potential, the opening degree of mitochondrial permeability transition pore (MPTP), and mRNA expressions of GPX4 and cyclophilin D (CypD) were detected. Furthermore, the expressions of ferroptosis-related proteins[GPX4, transferrin receptor 1 (TfR1) and ferritin heavy chain 1 (FTH1)], as well as MPTP-related proteins [adenine nucleotide translocator (ANT), cytochrome C (CytC), mitochondrial calcium uniporter (MCU) and CypD] were assessed. RESULTS Compared with si-NC group, the levels of total iron ions and ROS, the expression level of mitochondrial superoxide, the opening degree of MPTP, protein and its mRNA expressions of CypD as well as protein expressions of TfR1 and MCU were increased or up-regulated significantly (P<0.01); however, GSH content, mitochondrial membrane potential, protein and mRNA expressions of GPX4, and protein expressions of FTH1, ANT and CytC were decreased or down-regulated significantly (P<0.01). Compared with the si-GPX4 group, the cells in the DXQ-M, DXQ-H groups showed a general improvement in the above quantitative indicators (P<0.01 or P<0.05). CONCLUSIONS DXQ can enhance antioxidant capacity by activating the GSH/GPX4 pathway, regulate the expressions of TfR1 and FTH1 protein to correct iron ion homeostasis, inhibit excessive opening of MPTP to improve mitochondrial function, and ultimately suppress microglial ferroptosis.
2.Intelligent robot-assisted minimally invasive reduction system for fresh subtrochanteric fractures of the femur
Ruofei MA ; Chunpeng ZHAO ; Honghu XIAO ; Mingjian BEI ; Gang ZHU ; Yu WANG ; Yingchun SONG ; Xinbao WU
Chinese Journal of Orthopaedic Trauma 2025;27(2):109-116
Objective:To evaluate the feasibility and efficacy of our self-designed intelligent robot-assisted reduction system for fresh subtrochanteric fractures of the femur.Methods:A retrospective cohort study was conducted to include 10 patients with fresh subtrochanteric fracture of the femur who had been admitted to Department of Orthopedic Trauma, Beijing Jishuitan Hospital from January 2024 to July 2024. There were 7 males and 3 females with an age of (45.0±14.3) years and an interval from injury to surgery of (7.9±3.7) d. All the patients were treated by minimally invasive reduction which was assisted by our self-designed intelligent robot, and internal fixation with intramedullary nails. The operation duration, intraoperative reduction duration, intraoperative blood loss, and intraoperative fluoroscopy frequency were recorded. The reduction effect was evaluated by calculating the differences between preoperative planning and postoperative CT reconstruction (i.e., the differences in femoral shaft length and in rotation angle). The hip functional recovery was assessed by Harris hip function Scoring.Results:The mean operation time was 200.0 (161.3, 217.5) min, the reduction time (83.0±35.5) min, the intraoperative blood loss (290.0±110.1) mL, and the intraoperative fluoroscopy 18.5 (9.0, 19.3) times. In all patients, the difference in femoral shaft length was (2.4±1.4) mm, and the difference in rotation angle 5.1°±3.0°. All patients were followed up for (8.2±2.0)months. All the fractures got united at the last follow-up. Their Harris hip function score was (83.3±4.1) points.Conclusion:Our self-designed intelligent robot-assisted reduction system is feasible and effective in the surgery of fresh subtrochanteric fracture of the femur, because the robot system can complete the autonomous planning of reduction approaches before surgery and assist fracture reduction under real-time monitoring with three-dimensional images, leading to fine outcomes.
3.Heterotopic ossification: Current developments and emerging potential therapies.
Mingjian BEI ; Qiyong CAO ; Chunpeng ZHAO ; Yaping XIAO ; Yimin CHEN ; Honghu XIAO ; Xu SUN ; Faming TIAN ; Minghui YANG ; Xinbao WU
Chinese Medical Journal 2025;138(4):389-404
This review aimed to provide a comprehensive analysis of the etiology, epidemiology, pathology, and conventional treatment of heterotopic ossification (HO), especially emerging potential therapies. HO is the process of ectopic bone formation at non-skeletal sites. HO can be subdivided into two major forms, acquired and hereditary, with acquired HO predominating. Hereditary HO is a rare and life-threatening genetic disorder, but both acquired and hereditary form can cause severe complications, such as peripheral nerve entrapment, pressure ulcers, and disability if joint ankylosis develops, which heavily contributes to a reduced quality of life. Modalities have been proposed to treat HO, but none have emerged as the gold standard. Surgical excision remains the only effective modality; however, the optimal timing is controversial and may cause HO recurrence. Recently, potential therapeutic strategies have emerged that focus on the signaling pathways involved in HO, and small molecule inhibitors have been shown to be promising. Moreover, additional specific targets, such as small interfering RNAs (siRNAs) and non-coding RNAs, could be used to effectively block HO or develop combinatorial therapies for HO.
Humans
;
Ossification, Heterotopic/genetics*
4.TiRobot-assisted minimally invasive treatment of coracoid process fractures of scapula.
Yonghong DAI ; Qingyu LI ; Yanhui ZENG ; Zhengjie WU ; Chunpeng ZHAO ; Junqiang WANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):40-46
OBJECTIVE:
To explore effectiveness of TiRobot-assisted screw implantation in the treatment of coracoid process fractures of the scapula.
METHODS:
A retrospective analysis was conducted on the clinical data from 24 patients with coracoid process fractures of the scapula admitted between September 2019 and January 2024 and met selection criteria. Among them, 12 patients underwent TiRobot-assisted screw implantation (robot group) and 12 underwent manual screw implantation (control group) during internal fixation. There was no significant difference ( P>0.05) in baseline data such as gender, age, body mass index, disease duration, cause of injury, coracoid process fracture classification, and proportion of patients with associated injuries between the two groups. The incision length, operation time, intraoperative blood loss, hospital stay, accuracy of screw placement, coracoid process fracture healing time, and complications were recorded and compared, as well as pain visual analogue scale (VAS) score, and Constant-Murley score at last follow-up.
RESULTS:
The intraoperative blood loss and incision length in the robot group were significantly lower than those in the control group ( P<0.05); however, there was no significant difference in operation time and hospital stay between the two groups ( P>0.05). All patients were followed up 8-27 months (mean, 17.5 months), and the difference in follow-up time between the two groups was not significant ( P>0.05). At last follow-up, the VAS score for shoulder pain in the robot group was signifncatly lower compared to the control group, and the Constant-Murley score was significantly higher ( P<0.05). In the robot group, 16 screws were implanted intraoperatively, while 13 screws were implanted in the control group. Radiographic re-evaluation showed that the excellent and good rate of screw implantation was higher in the robot group (93.8%, 15/16) than in the control group (61.5%, 8/13), but the difference in the precision of screw implantation between the two groups was not significant ( P>0.05). Four patients in the robot group and 1 in the control group achieved double screws fixation; however, the difference in achieving double screws fixation between the two groups was not significant ( P>0.05). All fractures healed in both groups with 1 case of malunion in the control group. There was no significant difference in healing time between the two groups ( P>0.05). During follow-up, 1 patient in the control group experienced screw loosening and displacement. There was no significant difference in the incidence of screw loosening and fracture malunion between the two groups ( P>0.05).
CONCLUSION
Compared with manual screw implantation, TiRobot-assisted minimally invasive treatment of coracoid process fractures of the scapula can reduce intraoperative blood loss, shorten incision length, alleviate pain, and obtain better promote shoulder joint functional recovery.
Humans
;
Male
;
Female
;
Retrospective Studies
;
Fracture Fixation, Internal/instrumentation*
;
Minimally Invasive Surgical Procedures/instrumentation*
;
Adult
;
Middle Aged
;
Fractures, Bone/surgery*
;
Bone Screws
;
Coracoid Process/surgery*
;
Robotic Surgical Procedures/methods*
;
Scapula/surgery*
;
Treatment Outcome
;
Operative Time
;
Young Adult
;
Length of Stay
;
Blood Loss, Surgical
5.Intelligent robot-assisted minimally invasive reduction system for fresh subtrochanteric fractures of the femur
Ruofei MA ; Chunpeng ZHAO ; Honghu XIAO ; Mingjian BEI ; Gang ZHU ; Yu WANG ; Yingchun SONG ; Xinbao WU
Chinese Journal of Orthopaedic Trauma 2025;27(2):109-116
Objective:To evaluate the feasibility and efficacy of our self-designed intelligent robot-assisted reduction system for fresh subtrochanteric fractures of the femur.Methods:A retrospective cohort study was conducted to include 10 patients with fresh subtrochanteric fracture of the femur who had been admitted to Department of Orthopedic Trauma, Beijing Jishuitan Hospital from January 2024 to July 2024. There were 7 males and 3 females with an age of (45.0±14.3) years and an interval from injury to surgery of (7.9±3.7) d. All the patients were treated by minimally invasive reduction which was assisted by our self-designed intelligent robot, and internal fixation with intramedullary nails. The operation duration, intraoperative reduction duration, intraoperative blood loss, and intraoperative fluoroscopy frequency were recorded. The reduction effect was evaluated by calculating the differences between preoperative planning and postoperative CT reconstruction (i.e., the differences in femoral shaft length and in rotation angle). The hip functional recovery was assessed by Harris hip function Scoring.Results:The mean operation time was 200.0 (161.3, 217.5) min, the reduction time (83.0±35.5) min, the intraoperative blood loss (290.0±110.1) mL, and the intraoperative fluoroscopy 18.5 (9.0, 19.3) times. In all patients, the difference in femoral shaft length was (2.4±1.4) mm, and the difference in rotation angle 5.1°±3.0°. All patients were followed up for (8.2±2.0)months. All the fractures got united at the last follow-up. Their Harris hip function score was (83.3±4.1) points.Conclusion:Our self-designed intelligent robot-assisted reduction system is feasible and effective in the surgery of fresh subtrochanteric fracture of the femur, because the robot system can complete the autonomous planning of reduction approaches before surgery and assist fracture reduction under real-time monitoring with three-dimensional images, leading to fine outcomes.
6.Study on the prognostic factors related to interventional therapy in patients with acute myocardial infarction assisted by VA-ECMO
Junduo WU ; Chunpeng ZHANG ; Bo LI ; Lei ZHAO ; Jinwu LI ; Mingsong ZHANG ; Shengnan XU ; Bin LIU
Chinese Journal of Cardiology 2025;53(6):661-665
Objective:To investigate the prognostic factors in patients with acute myocardial infarction (AMI) who underwent interventional therapy assisted by venous-arterial extracorporeal membrane oxygenation (VA-ECMO).Methods:This single-center retrospective cohort study enrolled AMI patients who received VA-ECMO-assisted interventional therapy in the Department of Cardiology at the Second Hospital of Jilin University from June 2018 to November 2022. Patients were divided into the in-hospital survival group and in-hospital death group based on the in-hospital survival. Data on patient demographics, laboratory tests, imaging examinations, coronary angiography results, VA-ECMO-related parameters, complications, and prognosis were collected through the electronic medical record system.Results:A total of 71 AMI patients were enrolled, with an age of (62.4±11.1) years, of whom 54 (76%) were male. There were 46 patients in the in-hospital survival group and 25 patients in the in-hospital death group. Compared to the in-hospital survival group, the in-hospital death group exhibited significantly higher levels of cardiac troponin I (36.08 (2.86, 100.00) μg/L vs. 2.75 (0.18, 13.86) μg/L, P=0.01) and B-type natriuretic peptide (1 724.50 (50.00, 4 200.50) vs. 460.85 (163.80, 1 862.33), P=0.01), and the left ventricular ejection fraction was lower ((35.0±12.9)% vs. (43.0±12.8)%, P=0.01), moreover the incidence of patients with left main coronary artery disease (80% (20/25) vs. 39% (18/46), P<0.01), cardiac arrest (56% (14/25) vs. 20% (9/46), P<0.01), cardiopulmonary resuscitation (52%(13/25) vs. 26%(12/46), P=0.03), and the time from cardiac arrest to ECMO initiation >24 hours (84% (21/25) vs. 9% (4/46), P<0.01) were higher. Conclusions:The prognosis of AMI patients undergoing VA-ECMO-assisted interventional therapy may be influenced by a number of related factors, including cardiac troponin I, B-type natriuretic peptide levels, left ventricular ejection fraction, combined with left main coronary artery disease, cardiac arrest and cardiopulmonary resuscitation, and the interval between cardiac arrest and the initiation of ECMO.
7.Study on the prognostic factors related to interventional therapy in patients with acute myocardial infarction assisted by VA-ECMO
Junduo WU ; Chunpeng ZHANG ; Bo LI ; Lei ZHAO ; Jinwu LI ; Mingsong ZHANG ; Shengnan XU ; Bin LIU
Chinese Journal of Cardiology 2025;53(6):661-665
Objective:To investigate the prognostic factors in patients with acute myocardial infarction (AMI) who underwent interventional therapy assisted by venous-arterial extracorporeal membrane oxygenation (VA-ECMO).Methods:This single-center retrospective cohort study enrolled AMI patients who received VA-ECMO-assisted interventional therapy in the Department of Cardiology at the Second Hospital of Jilin University from June 2018 to November 2022. Patients were divided into the in-hospital survival group and in-hospital death group based on the in-hospital survival. Data on patient demographics, laboratory tests, imaging examinations, coronary angiography results, VA-ECMO-related parameters, complications, and prognosis were collected through the electronic medical record system.Results:A total of 71 AMI patients were enrolled, with an age of (62.4±11.1) years, of whom 54 (76%) were male. There were 46 patients in the in-hospital survival group and 25 patients in the in-hospital death group. Compared to the in-hospital survival group, the in-hospital death group exhibited significantly higher levels of cardiac troponin I (36.08 (2.86, 100.00) μg/L vs. 2.75 (0.18, 13.86) μg/L, P=0.01) and B-type natriuretic peptide (1 724.50 (50.00, 4 200.50) vs. 460.85 (163.80, 1 862.33), P=0.01), and the left ventricular ejection fraction was lower ((35.0±12.9)% vs. (43.0±12.8)%, P=0.01), moreover the incidence of patients with left main coronary artery disease (80% (20/25) vs. 39% (18/46), P<0.01), cardiac arrest (56% (14/25) vs. 20% (9/46), P<0.01), cardiopulmonary resuscitation (52%(13/25) vs. 26%(12/46), P=0.03), and the time from cardiac arrest to ECMO initiation >24 hours (84% (21/25) vs. 9% (4/46), P<0.01) were higher. Conclusions:The prognosis of AMI patients undergoing VA-ECMO-assisted interventional therapy may be influenced by a number of related factors, including cardiac troponin I, B-type natriuretic peptide levels, left ventricular ejection fraction, combined with left main coronary artery disease, cardiac arrest and cardiopulmonary resuscitation, and the interval between cardiac arrest and the initiation of ECMO.
8.Operative treatment of geriatric pelvic fractures
Qiyong CAO ; Chunpeng ZHAO ; Honghu XIAO ; Mingjian BEI ; Xinbao WU
Chinese Journal of Orthopaedic Trauma 2024;26(3):222-227
Objective:To explore the clinical efficacy of operative treatment of geriatric pelvic fractures.Methods:A retrospective study was conducted to analyze the clinical data of 55 geriatric patients with pelvic fracture who had been operatively treated at Department of Orthopaedic Trauma, Beijing Jishuitan Hospital from January 2020 to October 2023. There were 13 males and 42 females with an age of 72.0 (68.0, 83.3) years. By the AO/OTA classification, there were 47 cases of type B and 8 cases of type C; by the classification for fragility fractures of pelvis, there were 5 cases of type Ⅱ, 44 cases of type Ⅲ, and 6 cases of type Ⅳ. The patients received operative treatment 4.0 (3.0, 6.3) days after injury. Of the 10 patients treated by open reduction and closed reduction, the posterior ring was fixated by a plate in 7 and by screws in 3, and the anterior ring was fixated by either a plate, an external fixator or a minimally invasive anterior pelvic ring internal fixator except in the 2 cases receiving no fixation. Of the other 45 patients treated by closed reduction and fixation, the posterior ring was all fixated by screws except in the 2 cases receiving no fixation, and the anterior ring was fixated by either screws, an external fixator or a minimally invasive anterior pelvic ring internal fixator except in the 10 cases receiving no fixation. The major peri-operative complications, quality of fracture reduction, mortality, and functional recovery of the pelvis at the last follow-up were recorded.Results:There were no major peri-operative complications. According to the Matta criteria, the quality of fracture reduction was excellent in 31, good in 14, fair in 8 and poor in 2 cases, giving a good to excellent rate of 81.8% (45/55). Fifty-four cases were followed up for (15.4±9.1) months and 1 case was lost to the follow-up. Four cases died within 1 year after operation, giving a mortality of 7.4% (4/54). The modified Majeed score at the last follow-up was 69 (54, 76) for the 46 cases who had been followed up for longer than 4 months; the functional recovery of the pelvis at the last follow-up was rated as excellent in 27 cases, as good in 8 cases and as fair in 11 cases, giving a good to excellent rate of 76.1% (35/46) according to the criteria proposed by the faculty of the writers. The internal fixation failed in 3 cases during the follow-up.Conclusion:For the geriatric pelvic fractures, operative treatment can lead to satisfactory clinical outcomes.
9.A digital classification system of pelvic fractures based on close reduction techniques
Xu SUN ; Yuneng LI ; Qiyong CAO ; Chunpeng ZHAO ; Yimin CHEN ; Minghui YANG ; Shiwen ZHU ; Honghua WU ; Xinbao WU
Chinese Journal of Orthopaedic Trauma 2024;26(5):428-434
Objective:To explore the feasibility and consistency of a new digital classification system of pelvic fractures named as JST classification based on close reduction techniques.Methods:A retrospective collection was conducted of the data from the 63 patients with pelvic fracture who had undergone surgical treatment after JST classification at Department of Orthopaedics and Traumatology, Beijing Jishuitan Hospital from March 2021 to March 2023. Digital classification of the pelvic fractures was performed based on their locations and displacements. The classification first divides the pelvis into 4 parts: left half pelvis and right half pelvis; sacral Denis Ⅲ area and pubic symphysis. The symmetrical left and right sacral Denis Ⅰ and Denis Ⅱ areas are also included in the left/right half pelvis. Subsequently, the left half pelvis and right half pelvis are divided into 4 regions and marked by capitalized English letters: Sacrum Area (including Denis Ⅰ and Denis Ⅱ, denoted as S), Sacroiliac Joint Area (denoted as J), Iliac Area (denoted as I), and Pubic Area (denoted as P); to distinguish right/left, R and L are used as prefixes. The 2 asymmetric parts are also marked with English letters: Denis Ⅲ area of the sacrum (denoted as Sac), and pubic symphysis (denoted as C). Afterwards, the fracture line morphology and displacement in each region are marked digitally to form a complete JST classification system. The inter- and intra-observer reliabilities (Fleiss' and Cohen's Kappa) of the JST classification system were tested by 3 observers with more than 10 years of experience in pelvic fracture treatment.Results:Consistency analysis of the JST classification results showed that the mean κ value of the intra-observer reliability was 0.818 (from 0.658 to 0.946, P<0.001) and the inter-observer reliability 0.873 (from 0.674 to 1.000, P<0.001), both indicating excellent agreement. Of the 63 patients, 59 obtained successful closed reduction with the assistance of the Rossum Robot R-Universal intelligent orthopedic surgical robot system after fracture classification by the JST system, yielding a success rate of 93.7% (59/63). Conclusions:The new JST classification system for pelvic fractures demonstrates strong intra and inter-observer reliabilities compared with traditional classification systems. As JST classification system labels each fracture site and key bones, it is of great significance for the deep learning and intraoperative operations of intelligent fracture robots.
10.Fixation with a 3D printed individualized custom-made plate for elderly patients with periprosthetic femoral fracture: an analysis of short-term efficacy
Mingjian BEI ; Chunpeng ZHAO ; Gang LIU ; Honghu XIAO ; Hangyu GU ; Qiyong CAO ; Minghui YANG ; Xinbao WU
Chinese Journal of Orthopaedic Trauma 2023;25(3):254-259
Objective:To explore the short-term efficacy of fixation with a 3D printed individualized custom-made plate in the treatment of elderly patients with periprosthetic femoral fracture.Methods:Retrospectively analyzed were the 5 elderly patients with periprosthetic femoral fracture who had been treated by fixation with a 3D printed individualized custom-made plate from January 2022 to July 2022 at Department of Orthopaedics and Traumatology, Beijing Jishuitan Hospital. There were 3 males and 2 females, aged 81, 86, 77, 91 and 87 years, respectively. One left and 4 right limbs were affected. Vancouver classification: type B1 ( n=3), type B2 ( n=1), and type C ( n=1). The time from operation to injury was 5, 6, 10, 5 and 7 days, respectively. Preoperatively, the femur affected, prosthesis and individualized plate with a greater trochanteric hook, loop cable channel and bone-like trabecular microporous structure were custom-made by 3D printing according to 1:1 models. Virtual operations were simulated to formulate surgical protocols. The operation time, length of surgical incision, intraoperative blood loss and transfusion, hospital stay, hip function and complications at the last follow-up were recorded. Results:The 5 patients were followed up for 12, 7, 10, 3 and 6 months, respectively. There were no events of superficial incision or deep prosthesis infection. Respectively, the operation time was 1.8, 1.7, 2.3, 2.0 and 3.3 h; the length of surgical incision 31, 30, 38, 27 and 30 cm; the intraoperative bleeding volume 400, 300, 300, 500 and 600 mL; the length of hospital stay 8, 9, 15, 14 and 11 d. Four patients received intraoperative blood transfusion of 300, 900, 150 and 1, 050 mL, respectively. One patient died of a heart attack 3 months after discharge; another patient developed dyskinesia at the contralateral limb 3 months after discharge due to cerebral infarction and died of recurrent cerebral infarction 7 months after discharge. At the last follow-up, the Harris hip scores of 3 patients were 86, 77 and 69 points, respectively. None of the patients had complications like breakage or loosening of implants.Conclusion:In the treatment of elderly patients with periprosthetic femoral fracture, fixation with a 3D printed individualized custom-made plate may lead to fine limb function and good short-term curative efficacy.