1.Quality evaluation of Gegen Formula Granules
Dai-liang ZHANG ; Chun-xia WANG ; Lei SHI ; Yu-kang LIU ; Yong-qiang LIN ; Yu-zhuo WANG ; Jing-hua ZHANG ; Jin-xin LI ; Gui-yun CAO ; Zhao-qing MENG
Chinese Traditional Patent Medicine 2025;47(5):1421-1431
AIM To evaluate the quality of Gegen Formula Granules.METHODS Linear calibration with two reference substances(LCTRS)was adopted in the predicting of retention time with puerarin and daidzein as internal standards.UPLC characteristic chromatograms were established.The contents of 3'-hydroxy puerarin,puerarin(internal standard),3'-methoxy puerarin,puerarin 6"-O-xyloside,puerarin apioside and daidzin were determined by quantitative determination analysis multi-components by a single marker(QAMS),after which their transfer rates were calculated.RESULTS Compared with relative retention time method,LCTRS demonstrated higher positional accuracy for characteristic peaks and wider application range for columns.There were 9 characteristic peaks in the characteristic chromatograms for 14 batches of formula granules and 15 batches of standard decoctions with the similarities of more than 0.95.The contents and transfer rates of various constituents in formula granules and standard decoctions were basically consistent.CONCLUSION The chemical constituents in formula granules and their standard decoctions of Puerariae lobatae Radix display good consistency,reliable preparation process is observable in the former.
2.Influence of surface structure of 3D-printed silk fibroin-based scaffolds on bronchial epithelial cells growth in vitro
Zhong-chun CHEN ; Nong-ping ZHONG ; Tao DONG ; Zheng-zhong SHAO ; Xia ZHAO
Fudan University Journal of Medical Sciences 2025;52(4):475-483
Objective To investigate the effect of the structure of 3D-printed silk fibroin/hydroxypropyl methylcellulose(SF/HPMC)scaffolds on the growth of tracheal epithelial cells in vitro.Methods Six types of SF/HPMC scaffolds with different surface topography,pore size,and porosity were fabricated using a 3D printer by adjusting the concentration of SF/HPMC solutions and printing parameters,combined with freeze-drying.Normal human bronchial epithelial cell lines BEAS-2B were cultured on these scaffolds for 7 days.The cell proliferation was detected by CCK-8 assay and live/dead cell staining,and the cell morphology was observed by scanning electron microscopy(SEM).Results The porosity of 20%(weight percentage)SF/HPMC scaffolds with rough surface and smooth surface were 70.5%±2.0%and 65.5%±6.1%,respectively,and the porosity of 30%(weight percentage)SF/HPMC scaffolds with rough surface and smooth surface were 63.9%±2.1%and 59.6%±2.1%,respectively.The two pore sizes of the rough-surfaced 20%SF/HPMC scaffolds were(443.9±104.1)μm and(681.1±115.1)μm.BEAS-2B cells spread better on the rough-surfaced scaffolds,and their proliferation was higher on scaffolds with higher porosity and smaller pore sizes compared to those with lower porosity and larger pore sizes.Conclusion The 3D-printed SF/HPMC scaffolds are suitable for bronchial epithelial cell growth.Scaffolds with rough surfaces,higher porosity,and appropriate pore sizes might facilitate BEAS-2B cell growth.
3.Necessity of blood hemocompatibility evaluation in medical devices with indirect contact with blood
Chun-xia QIAO ; Qiu-jin QU ; Li HOU ; Zeng-lin ZHAO ; Xiang-yu CHU ; Xiao-xia SUN
Chinese Medical Equipment Journal 2025;46(8):44-49
Objective To study the need for blood compatibility evaluation of medical devices that come into indirect contact with blood in order to accurately evaluate the risk of their interaction with blood.Methods Seven medical devices with indirect contact with blood were selected as samples including extension tubes of central venous catheters,port bodies of implantable drug delivery devices,infusion sets,receiving lines of dialysis equipment,auxiliary lines of left ventricular assist devices,blood monitors and catheter holders,with high-density polyethylene as the negative control,glass beads as the positive control and blank whole blood or plasma for the blank control.Partial thromboplastin time(PTT)test,platelet count test and hematology test(white blood cell and red blood cell count)were performed by direct contact method and indirect contact method,respectively.In the direct contact method,whole blood or plasma was in direct contact with the sample;while in the indirect contact method,whole blood or plasma was not in direct contact with the extraction solution,with no direct contact with the sample.Results With the indirect contact method the ratios(expressed as a percentage)of the PTT,platelate,WBC and RBC counts of the samples,positive and negative controls to those of the blank control were all higher than those with the direct contact method,and the indirect contact method had the sensitivity lower than that of the direct contact method.Conclusion Medical devices indirectly contacting blood have low risks for causing coagulation and platelet and hematologic adverse reactions,which are suggested to be evaluated for hemolysis testing only in case of the history of safe clinical use.[Chinese Medical Equipment Journal,2025,46(8):44-49]
4.Design and synthesis of novel saponin-triazole derivatives in the regulation of adipogenesis.
Yongsheng FANG ; Zhiyun ZHU ; Chun XIE ; Dazhen XIA ; Huimin ZHAO ; Zihui WANG ; Qian LU ; Caimei ZHANG ; Wenyong XIONG ; Xiaodong YANG
Chinese Journal of Natural Medicines (English Ed.) 2025;23(8):920-931
Saponins associated with Panax notoginseng (P. notoginseng) demonstrate significant therapeutic efficacy across multiple diseases. However, certain high-yield saponins face limited clinical applications due to their reduced pharmacological efficacy. This study synthesized and evaluated 36 saponin-1,2,3-triazole derivatives of ginsenosides Rg1/Rb1 and notoginsenoside R1 for anti-adipogenesis activity in vitro. The research revealed that the ginsenosides Rg1-1,2,3-triazole derivative a17 demonstrates superior adipogenesis inhibitory effects. Structure-activity relationships (SARs) analysis indicates that incorporating an amidyl-substituted 1,2,3-triazole into the saponin side chain via Click reaction enhances anti-adipogenesis activity. Additionally, several other derivatives exhibit general adipogenesis inhibition. Compound a17 demonstrated enhanced potency compared to the parent ginsenoside Rg1. Mechanistic investigations revealed that a17 exhibits dose-dependent inhibition of adipogenesis in vitro, accompanied by decreased expression of preadipocytes. Peroxisome proliferator-activated receptor γ (PPARγ), fatty acid synthase (FAS), and fatty acid binding protein 4 (FABP4) adipogenesis regulators. These findings establish the ginsenoside Rg1-1,2,3-triazole derivative a17 as a promising adipocyte differentiation inhibitor and potential therapeutic agent for obesity and associated metabolic disorders. This research provides a foundation for developing effective therapeutic approaches for various metabolic syndromes.
Adipogenesis/drug effects*
;
Triazoles/chemical synthesis*
;
Ginsenosides/chemical synthesis*
;
Saponins/chemical synthesis*
;
Animals
;
Mice
;
Structure-Activity Relationship
;
PPAR gamma/genetics*
;
3T3-L1 Cells
;
Adipocytes/metabolism*
;
Panax notoginseng/chemistry*
;
Drug Design
;
Molecular Structure
;
Humans
;
Cell Differentiation/drug effects*
;
Fatty Acid-Binding Proteins/genetics*
5.Threshold-Effect Associations of Serum 25-hydroxyvitamin D on Bone Turnover Markers and GC rs2282679 Variants in Chinese Women of Childbearing Age.
Xiao Yun SHAN ; Yu Ting LI ; Xia Yu ZHAO ; Yi Chun HU ; Si Ran LI ; Hui di ZHANG ; Yang CAO ; Rui WANG ; Li Chen YANG
Biomedical and Environmental Sciences 2025;38(4):433-446
OBJECTIVE:
This study aimed to investigate possible serum 25-hydroxyvitamin D [25(OH)D] cutoffs for the associations between 25(OH)D and Bone turnover markers (BTMs), and how GC gene variation influences such cutoffs in Chinese women of childbearing age.
METHODS:
In total, 1,505 non-pregnant or non-lactating women (18-45 years) were recruited from the 2015 Chinese Adult Chronic Disease and Nutrition Surveillance. Serum 25(OH)D, osteocalcin (OC), procollagen type 1 N-terminal propeptide (P1NP), β-CrossLaps of type 1 collagen containing cross-linked C-telopeptide (β-CTX), and single nucleotide polymorphisms were determined. Locally weighted regression and smoothing scatterplot and segmented regression were performed to estimate the 25(OH)D thresholds.
RESULTS:
The median serum 25(OH)D was 16.63 (11.96-22.55) ng/mL and the prevalence of low serum 25(OH)D (< 12 ng/mL) was 25.2%. Women with the lowest 25(OH)D had the highest β-CTX. After adjustment for the confounders, 25(OH)D cutoffs for OC [14.04 (12.84-15.23) ng/mL], β-CTX [13.94 (12.49-15.39) ng/mL], and P1NP [13.87 (12.37-15.37) ng/mL] in the whole population, cutoffs for OC [12.30 (10.68-13.91) ng/mL], β-CTX [12.23 (10.22-14.23) ng/mL], and P1NP [11.85 (10.40-13.31) ng/mL] in women with the GC rs2282679 G allele, and cutoffs for OC [12.75 (11.81-13.68) ng/mL], β-CTX [13.05 (11.78-14.32) ng/mL], and P1NP [12.81 (11.57-14.06) ng/mL] in women with the GC rs2282679 T allele, were observed. Below these cutoffs, BTMs were negatively associated with 25(OH)D, while above these cutoffs, BTMs plateaued.
CONCLUSION
In Chinese women of childbearing age, there were thresholds effect of serum 25(OH)D concentrations on BTMs. The results indicated that serum 25(OH)D concentrations < 13.87 ng/mL in this population had adverse influences on maintaining bone remodeling. BTMs were suppressed at a relatively lower serum 25(OH)D in women with the GC rs2282679 G allele compared with those with the T allele.
Humans
;
Female
;
Vitamin D/blood*
;
Adult
;
Middle Aged
;
Polymorphism, Single Nucleotide
;
Adolescent
;
Young Adult
;
China
;
Biomarkers/blood*
;
Bone Remodeling/genetics*
;
Vitamin D-Binding Protein/genetics*
;
Procollagen/blood*
;
Osteocalcin/blood*
;
Peptide Fragments/blood*
;
East Asian People
6.Association of Body Mass Index with All-Cause Mortality and Cause-Specific Mortality in Rural China: 10-Year Follow-up of a Population-Based Multicenter Prospective Study.
Juan Juan HUANG ; Yuan Zhi DI ; Ling Yu SHEN ; Jian Guo LIANG ; Jiang DU ; Xue Fang CAO ; Wei Tao DUAN ; Ai Wei HE ; Jun LIANG ; Li Mei ZHU ; Zi Sen LIU ; Fang LIU ; Shu Min YANG ; Zu Hui XU ; Cheng CHEN ; Bin ZHANG ; Jiao Xia YAN ; Yan Chun LIANG ; Rong LIU ; Tao ZHU ; Hong Zhi LI ; Fei SHEN ; Bo Xuan FENG ; Yi Jun HE ; Zi Han LI ; Ya Qi ZHAO ; Tong Lei GUO ; Li Qiong BAI ; Wei LU ; Qi JIN ; Lei GAO ; He Nan XIN
Biomedical and Environmental Sciences 2025;38(10):1179-1193
OBJECTIVE:
This study aimed to explore the association between body mass index (BMI) and mortality based on the 10-year population-based multicenter prospective study.
METHODS:
A general population-based multicenter prospective study was conducted at four sites in rural China between 2013 and 2023. Multivariate Cox proportional hazards models and restricted cubic spline analyses were used to assess the association between BMI and mortality. Stratified analyses were performed based on the individual characteristics of the participants.
RESULTS:
Overall, 19,107 participants with a sum of 163,095 person-years were included and 1,910 participants died. The underweight (< 18.5 kg/m 2) presented an increase in all-cause mortality (adjusted hazards ratio [ aHR] = 2.00, 95% confidence interval [ CI]: 1.66-2.41), while overweight (≥ 24.0 to < 28.0 kg/m 2) and obesity (≥ 28.0 kg/m 2) presented a decrease with an aHR of 0.61 (95% CI: 0.52-0.73) and 0.51 (95% CI: 0.37-0.70), respectively. Overweight ( aHR = 0.76, 95% CI: 0.67-0.86) and mild obesity ( aHR = 0.72, 95% CI: 0.59-0.87) had a positive impact on mortality in people older than 60 years. All-cause mortality decreased rapidly until reaching a BMI of 25.7 kg/m 2 ( aHR = 0.95, 95% CI: 0.92-0.98) and increased slightly above that value, indicating a U-shaped association. The beneficial impact of being overweight on mortality was robust in most subgroups and sensitivity analyses.
CONCLUSION
This study provides additional evidence that overweight and mild obesity may be inversely related to the risk of death in individuals older than 60 years. Therefore, it is essential to consider age differences when formulating health and weight management strategies.
Humans
;
Body Mass Index
;
China/epidemiology*
;
Male
;
Female
;
Middle Aged
;
Prospective Studies
;
Rural Population/statistics & numerical data*
;
Aged
;
Follow-Up Studies
;
Adult
;
Mortality
;
Cause of Death
;
Obesity/mortality*
;
Overweight/mortality*
7.Development and validation of the rapid health aging assessment scale for the Chinese population
Bingqi YE ; Jialu YANG ; Jianhua LI ; Wunong CHEN ; Jianhua YE ; Xiaotao ZHOU ; Yong WANG ; Siqi LI ; Qi ZHANG ; Wanying ZHAO ; Jiayi SONG ; Chun WANG ; Yan LIU ; Min XIA
Chinese Journal of Preventive Medicine 2025;59(7):1078-1083
Objective:To develop a rapid assessment scale for healthy aging suitable for the Chinese population.Methods:Based on existing healthy aging assessment scales, national standards, and expert consensus, an initial Healthy Aging Rapid Assessment Scale was drafted through two rounds of expert consultation. A pre-survey was conducted with 3 220 subjects recruited from Guangzhou between July 2023 and July 2024. Items were screened through item analysis and exploratory factor analysis to form the final scale. Reliability and validity of the final scale were validated across five cities: Guangzhou, Dongguan, Shenzhen, Baoding, and Chuxiong.Results:The initial version comprised 36 items, while the finalized scale contained 18 items across three dimensions: metabolic health, mental health, and cognitive health. Test-retest reliability ranged from 0.71 to 0.81 across all study sites. The Spearman-Brown coefficient varied between 0.91-0.96, Cronbach′s α between 0.77-0.83, comparative fit index (CFI) between 0.90-0.98, goodness-of-fit index (GFI) between 0.90-0.99, and root-mean-square error of approximation (RMSEA) between 0.03-0.09. For the three dimensions, reliability and validity metrics demonstrated consistency: Spearman-Brown coefficients 0.87-0.99, Cronbach′s α 0.77-0.83, CFI 0.90-0.98, GFI 0.90-0.99, and RMSEA 0.03-0.09 across four regions.Conclusion:The developed Healthy Aging Rapid Assessment Scale for the Chinese population exhibits robust reliability and validity.
8.Development and validation of the rapid health aging assessment scale for the Chinese population
Bingqi YE ; Jialu YANG ; Jianhua LI ; Wunong CHEN ; Jianhua YE ; Xiaotao ZHOU ; Yong WANG ; Siqi LI ; Qi ZHANG ; Wanying ZHAO ; Jiayi SONG ; Chun WANG ; Yan LIU ; Min XIA
Chinese Journal of Preventive Medicine 2025;59(7):1078-1083
Objective:To develop a rapid assessment scale for healthy aging suitable for the Chinese population.Methods:Based on existing healthy aging assessment scales, national standards, and expert consensus, an initial Healthy Aging Rapid Assessment Scale was drafted through two rounds of expert consultation. A pre-survey was conducted with 3 220 subjects recruited from Guangzhou between July 2023 and July 2024. Items were screened through item analysis and exploratory factor analysis to form the final scale. Reliability and validity of the final scale were validated across five cities: Guangzhou, Dongguan, Shenzhen, Baoding, and Chuxiong.Results:The initial version comprised 36 items, while the finalized scale contained 18 items across three dimensions: metabolic health, mental health, and cognitive health. Test-retest reliability ranged from 0.71 to 0.81 across all study sites. The Spearman-Brown coefficient varied between 0.91-0.96, Cronbach′s α between 0.77-0.83, comparative fit index (CFI) between 0.90-0.98, goodness-of-fit index (GFI) between 0.90-0.99, and root-mean-square error of approximation (RMSEA) between 0.03-0.09. For the three dimensions, reliability and validity metrics demonstrated consistency: Spearman-Brown coefficients 0.87-0.99, Cronbach′s α 0.77-0.83, CFI 0.90-0.98, GFI 0.90-0.99, and RMSEA 0.03-0.09 across four regions.Conclusion:The developed Healthy Aging Rapid Assessment Scale for the Chinese population exhibits robust reliability and validity.
9.Influence of surface structure of 3D-printed silk fibroin-based scaffolds on bronchial epithelial cells growth in vitro
Zhong-chun CHEN ; Nong-ping ZHONG ; Tao DONG ; Zheng-zhong SHAO ; Xia ZHAO
Fudan University Journal of Medical Sciences 2025;52(4):475-483
Objective To investigate the effect of the structure of 3D-printed silk fibroin/hydroxypropyl methylcellulose(SF/HPMC)scaffolds on the growth of tracheal epithelial cells in vitro.Methods Six types of SF/HPMC scaffolds with different surface topography,pore size,and porosity were fabricated using a 3D printer by adjusting the concentration of SF/HPMC solutions and printing parameters,combined with freeze-drying.Normal human bronchial epithelial cell lines BEAS-2B were cultured on these scaffolds for 7 days.The cell proliferation was detected by CCK-8 assay and live/dead cell staining,and the cell morphology was observed by scanning electron microscopy(SEM).Results The porosity of 20%(weight percentage)SF/HPMC scaffolds with rough surface and smooth surface were 70.5%±2.0%and 65.5%±6.1%,respectively,and the porosity of 30%(weight percentage)SF/HPMC scaffolds with rough surface and smooth surface were 63.9%±2.1%and 59.6%±2.1%,respectively.The two pore sizes of the rough-surfaced 20%SF/HPMC scaffolds were(443.9±104.1)μm and(681.1±115.1)μm.BEAS-2B cells spread better on the rough-surfaced scaffolds,and their proliferation was higher on scaffolds with higher porosity and smaller pore sizes compared to those with lower porosity and larger pore sizes.Conclusion The 3D-printed SF/HPMC scaffolds are suitable for bronchial epithelial cell growth.Scaffolds with rough surfaces,higher porosity,and appropriate pore sizes might facilitate BEAS-2B cell growth.
10.Necessity of blood hemocompatibility evaluation in medical devices with indirect contact with blood
Chun-xia QIAO ; Qiu-jin QU ; Li HOU ; Zeng-lin ZHAO ; Xiang-yu CHU ; Xiao-xia SUN
Chinese Medical Equipment Journal 2025;46(8):44-49
Objective To study the need for blood compatibility evaluation of medical devices that come into indirect contact with blood in order to accurately evaluate the risk of their interaction with blood.Methods Seven medical devices with indirect contact with blood were selected as samples including extension tubes of central venous catheters,port bodies of implantable drug delivery devices,infusion sets,receiving lines of dialysis equipment,auxiliary lines of left ventricular assist devices,blood monitors and catheter holders,with high-density polyethylene as the negative control,glass beads as the positive control and blank whole blood or plasma for the blank control.Partial thromboplastin time(PTT)test,platelet count test and hematology test(white blood cell and red blood cell count)were performed by direct contact method and indirect contact method,respectively.In the direct contact method,whole blood or plasma was in direct contact with the sample;while in the indirect contact method,whole blood or plasma was not in direct contact with the extraction solution,with no direct contact with the sample.Results With the indirect contact method the ratios(expressed as a percentage)of the PTT,platelate,WBC and RBC counts of the samples,positive and negative controls to those of the blank control were all higher than those with the direct contact method,and the indirect contact method had the sensitivity lower than that of the direct contact method.Conclusion Medical devices indirectly contacting blood have low risks for causing coagulation and platelet and hematologic adverse reactions,which are suggested to be evaluated for hemolysis testing only in case of the history of safe clinical use.[Chinese Medical Equipment Journal,2025,46(8):44-49]

Result Analysis
Print
Save
E-mail