1.Assessing High-density Y-SNP Panels for Paternal Haplogroup Assignment in Forensic Practice
De-Qin ZHANG ; Chun-Nian WANG ; Lin-Lin LOU ; Meng NI ; Jing GAO ; Jiang HUANG ; Li JIANG
Progress in Biochemistry and Biophysics 2026;53(2):458-469
ObjectiveThe accuracy of Y-chromosome haplogroup assignment is crucial for tracing paternal lineage in male samples. With the advancement of high-throughput sequencing technologies, high-density Y-SNP genotyping from whole-genome or array-based data has become a standard method for determiningY-chromosome haplogroups. This study systematically evaluated the performance of 4 commonly used high-density SNP genotyping systems—namely, the Global Screening Array (GSA), Chinese Genotyping Array (CGA), Affymetrix array, and the 1240K capture panel—for haplogroup assignment. This work provides a reference for data comparison across different systems. MethodsWe extracted genotype data for the 4 Y-SNP panels from 30× whole-genome sequencing (WGS) data of 1 590 male samples from the 1000 Genomes Project. Additionally, GSA array genotype data from 384 relative pairs (spanning 1st- to 12th-degree relationships) from 109 Chinese Han families were collected. Haplogroup assignment was performed using Y-LineageTracker v1.3.0 software. We assessed the concordance and resolution of haplogroup assignments between the four Y-SNP panels and the WGS data. The consistency and resolution of haplogroup assignments were also evaluated for both the 1000 Genomes Project samples and the 109 family samples collected in this study. Furthermore, the impact of varying numbers of Y-SNPs on haplogroup assignment was examined. ResultsThe GSA and CGA panels demonstrated superior resolution and discrimination of haplogroup subclades compared with the other two panels. The haplogroup assignments from the GSA, CGA, and 1240K panels showed high concordance with WGS data, with consistency rates exceeding 88.70%, whereas the Affymetrix platform exhibited a significantly lower consistency rate of 61.89%. Specifically, the GSA and CGA panels consistently demonstrated superior performance compared with the other two panels in the assignment of haplogroups O-M175 and H-L901, achieving complete concordance (100%) for both haplogroups. In contrast, the Affymetrix panel erroneously assigned all individuals belonging to haplogroup O-M175 to haplogroup K2-M526. Furthermore, its accuracy for haplogroup H-L901 was exceedingly low, at merely 1.41%. This poor performance was characterized by the misassignment of 98.59% of H-L901 samples—specifically, 1.41% to J-M304 and a predominant 97.18% to F-M89. For haplogroup R-M207, all four panels exhibited uniformly high levels of consistency, with concordance values exceeding 94.00%. Notably, for haplogroup E-M96, the 1240K and Affymetrix panels outperformed the GSA and CGA panels in terms of concordance, representing the first instance in which these two panels surpassed the latter. Conversely, for haplogroups J-M304, Q-M242, and I-M170, all 4 panels showed relatively elevated misclassification rates, with the Affymetrix array demonstrating the poorest overall performance. None of the four panels showed any discordant haplogroup assignments among the familial relative pairs analyzed. A positive correlation was observed between the number of Y-SNPs (ranging from 1 000 to 10 000) and classification consistency; however, classification consistency plateaued when the number of Y-SNPs exceeded 10 000. Furthermore, a random sampling analysis conducted on the GSA and CGA panels demonstrated that the haplogroup misclassification rate exhibited negligible fluctuation across the Y-SNP range of 500 to 1 000. Conversely, a marked enhancement in classification consistency was observed as the number of markers increased from 1 000 to 5 000, ultimately reaching a plateau within the interval of 5 000 to 8 000 markers. ConclusionThese findings indicate that the GSA and CGA panels provide high resolution and concordance, delivering reliable Y-haplogroup assignment for forensic investigations.
2.Assessing High-density Y-SNP Panels for Paternal Haplogroup Assignment in Forensic Practice
De-Qin ZHANG ; Chun-Nian WANG ; Lin-Lin LOU ; Meng NI ; Jing GAO ; Jiang HUANG ; Li JIANG
Progress in Biochemistry and Biophysics 2026;53(2):458-469
ObjectiveThe accuracy of Y-chromosome haplogroup assignment is crucial for tracing paternal lineage in male samples. With the advancement of high-throughput sequencing technologies, high-density Y-SNP genotyping from whole-genome or array-based data has become a standard method for determiningY-chromosome haplogroups. This study systematically evaluated the performance of 4 commonly used high-density SNP genotyping systems—namely, the Global Screening Array (GSA), Chinese Genotyping Array (CGA), Affymetrix array, and the 1240K capture panel—for haplogroup assignment. This work provides a reference for data comparison across different systems. MethodsWe extracted genotype data for the 4 Y-SNP panels from 30× whole-genome sequencing (WGS) data of 1 590 male samples from the 1000 Genomes Project. Additionally, GSA array genotype data from 384 relative pairs (spanning 1st- to 12th-degree relationships) from 109 Chinese Han families were collected. Haplogroup assignment was performed using Y-LineageTracker v1.3.0 software. We assessed the concordance and resolution of haplogroup assignments between the four Y-SNP panels and the WGS data. The consistency and resolution of haplogroup assignments were also evaluated for both the 1000 Genomes Project samples and the 109 family samples collected in this study. Furthermore, the impact of varying numbers of Y-SNPs on haplogroup assignment was examined. ResultsThe GSA and CGA panels demonstrated superior resolution and discrimination of haplogroup subclades compared with the other two panels. The haplogroup assignments from the GSA, CGA, and 1240K panels showed high concordance with WGS data, with consistency rates exceeding 88.70%, whereas the Affymetrix platform exhibited a significantly lower consistency rate of 61.89%. Specifically, the GSA and CGA panels consistently demonstrated superior performance compared with the other two panels in the assignment of haplogroups O-M175 and H-L901, achieving complete concordance (100%) for both haplogroups. In contrast, the Affymetrix panel erroneously assigned all individuals belonging to haplogroup O-M175 to haplogroup K2-M526. Furthermore, its accuracy for haplogroup H-L901 was exceedingly low, at merely 1.41%. This poor performance was characterized by the misassignment of 98.59% of H-L901 samples—specifically, 1.41% to J-M304 and a predominant 97.18% to F-M89. For haplogroup R-M207, all four panels exhibited uniformly high levels of consistency, with concordance values exceeding 94.00%. Notably, for haplogroup E-M96, the 1240K and Affymetrix panels outperformed the GSA and CGA panels in terms of concordance, representing the first instance in which these two panels surpassed the latter. Conversely, for haplogroups J-M304, Q-M242, and I-M170, all 4 panels showed relatively elevated misclassification rates, with the Affymetrix array demonstrating the poorest overall performance. None of the four panels showed any discordant haplogroup assignments among the familial relative pairs analyzed. A positive correlation was observed between the number of Y-SNPs (ranging from 1 000 to 10 000) and classification consistency; however, classification consistency plateaued when the number of Y-SNPs exceeded 10 000. Furthermore, a random sampling analysis conducted on the GSA and CGA panels demonstrated that the haplogroup misclassification rate exhibited negligible fluctuation across the Y-SNP range of 500 to 1 000. Conversely, a marked enhancement in classification consistency was observed as the number of markers increased from 1 000 to 5 000, ultimately reaching a plateau within the interval of 5 000 to 8 000 markers. ConclusionThese findings indicate that the GSA and CGA panels provide high resolution and concordance, delivering reliable Y-haplogroup assignment for forensic investigations.
3.Cage design-centric glider approach to full-endoscopic lumbar fusion: optimizing nerve root protection in facet-sparing and facet-resecting techniques
Yu-Chia HSU ; Hao-Chun CHUANG ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun-Sung KIM ; Cheng-Li LIN
Asian Spine Journal 2026;20(2):343-353
Endoscopic transforaminal lumbar interbody fusion (TLIF) offers substantial advantages in the management of degenerative spinal diseases, including accelerated postoperative recovery. However, its technical complexity and steep learning curve pose risks for nerve root injury. Optimizing nerve root protection in full-endoscopic facet-sparing TLIF (FE fs-TLIF) and full-endoscopic facet-resecting TLIF (FE fr-TLIF) is essential for enhancing surgical safety. This study aimed to improve the nerve root protection in FE fs-TLIF and FE fr-TLIF by optimizing cage glider selection and insertion techniques based on the specific cage shape—banana-shaped or bullet-shaped. The goal was to ensure safe cage positioning and mitigate nerve root injury during discectomy, endplate preparation, and cage insertion. These strategies were validated through cadaveric simulations and clinical implementation. In FE fr-TLIF utilizing bullet-shaped (straight) cages, one-tip and two-tip cage gliders effectively protected the traversing nerve root by facilitating medial cage entry, thereby minimizing irritation of the exiting nerve root. Conversely, in FE fr-TLIF with banana-shaped cages, the lateral tilt of the cage holder during implantation required the use of a two-tip cage glider to protect the traversing and exiting nerve roots, thereby mitigating the potential risk of nerve irritation. In FE fs-TLIF, a one-tip cage glider is preferred for safeguarding the exiting nerve root, while the traversing root is inherently protected by the medial wall of the facet joint. The use of a two-tip cage glider in FE fs-TLIF can cause injury to the nerve root during glider insertion. In addition to the selection of cage gliders, improper cage insertion steps can also contribute to postoperative neurapraxia. The appropriate selection of cage gliders with corresponding insertion techniques is critical for nerve root protection in endoscopic TLIF. Tailoring these choices to the specific approach (FE fs-TLIF or FE fr-TLIF) and cage type (banana or bullet) enhances surgical safety and clinical outcomes.
4.Research on Electrical Impedance and Microwave Dual-modality Tomography Algorithm Based on Conditional Diffusion Models
Jin-Zhen LIU ; Xiang-Qian MENG ; Hui XIONG ; Li-Min ZHOU ; Chun-Chan LI
Progress in Biochemistry and Biophysics 2026;53(6):1780-1792
ObjectiveStroke poses a heavy burden due to its high mortality and morbidity rates. Accurate and real-time detection of lesions is pivotal for prompt clinical intervention and favorable prognosis. Electrical impedance tomography (EIT) and microwave tomography (MWT) have emerged as compelling alternatives for stroke screening, owing to their non-ionizing, non-invasive and portable nature. EIT provides information on tissue conductivity, and MWT offers high sensitivity to changes in dielectric properties. However, single-modality imaging is inherently limited, EIT suffers from low sensitivity to deep-seated tissues and severe ill-posedness of inverse problems, whereas MWT is challenged by strong nonlinearity in inverse scattering and susceptibility to modeling errors. Consequently, the clinical utility of standalone EIT or MWT for stroke diagnosis remains constrained by poor spatial resolution and imaging artifacts. To improve the accuracy and robustness of stroke imaging, a dual-modality fusion conditional denoising diffusion probabilistic model (DM-DDPM) was proposed for high-precision dual-modality image reconstruction. MethodsA dual-encoder network with a symmetric architecture and independently trained parameters was constructed to extract heterogeneous features separately from EIT boundary voltage measurements and MWT scattered field signals. Attentional feature fusion (AFF) is employed to integrate complementary information from the two modalities adaptively, generating robust fused priors that suppress redundant noise while preserving key physical characteristics. Subsequently, the fused priors are embedded into a Transformer-based diffusion model via a cross attention mechanism to guide the reverse denoising process. This approach effectively reduces artifacts and enhances the stability of conductivity distribution reconstruction. Time step embedding is introduced to enable the network to perceive the diffusion stage and further improve the accuracy of noise prediction. ResultsSimulated experiments demonstrated that DM-DDPM significantly outperforms single-modality and multi-modality networks under various noise levels. A head model simulation dataset was constructed based on COMSOL Multiphysics, and tests were carried out under 50 dB, 40 dB and 30 dB signal-to-noise ratio levels. At 30 dB, the average relative error (RE) was below 0.20, while the structural similarity index measure (SSIM) and correlation coefficient (CC) remained above 0.90 and 0.89, respectively. Compared with single-modality and multi-modality networks, artifacts were significantly reduced, lesion edges were clearer, and localization was more accurate. The model maintains high reconstruction quality and strong robustness for single, double, and triple lesions simultaneously. Furthermore, physical experiments were conducted using a 16-electrode EIT system and a 16-antenna MWT system with asynchronous data acquisition. These experiments confirmed the feasibility of the method in real-world scenarios and demonstrated that it can robustly reconstruct simulated lesions despite environmental interference and measurement noise, validating its reliability for practical clinical applications. ConclusionThe proposed method effectively combines complementary dual-modality information with a conditional diffusion model. Low accuracy and poor noise resistance in single-modality imaging were effectively addressed, while the noise amplification issue caused by direct multimodal data fusion was avoided. The proposed algorithm exhibits strong anti-noise interference ability and high imaging stability in both simulation and physical experiments. Precise localization of stroke lesions with different quantities was achieved, providing a high-precision, and practical technical support for clinical stroke detection.
5.Jiawei Xiaoyao San exerts anti-liver cancer effects via exosomal miRNA pathway
Xiaoming LIU ; Jinlai CHENG ; Rushuang LI ; Niuniu LI ; Qiuyun QIN ; Meng XIA ; Chun YAO
Chinese Journal of Tissue Engineering Research 2025;29(19):4052-4062
BACKGROUND:Previous studies by our research group discovered that Jiawei Xiaoyao San has a significant anti-liver cancer effect,but the specific mechanism of action was unclear. OBJECTIVE:To investigate the regulatory effects of the traditional Chinese medicine formula Jiawei Xiaoyao San on the levels of miRNAs in plasma exosomes of rats with diethylnitrosamine chronically induced primary liver cancer,based on high-throughput sequencing combined with bioinformatics. METHODS:SD rats were randomly divided into a blank control group,a liver cancer model group,and a Jiawei Xiaoyao San treatment group.Liver cancer models were induced by continuous administration of diethylnitrosamine for 12 weeks.Starting from the 17th week,rats in the Jiawei Xiaoyao San treatment group were administered Jiawei Xiaoyao San once daily until the end of the 20th week,while rats in the blank control and liver cancer model groups were given an equivalent volume of saline.Anti-hepatocellular carcinoma effects were validated by assessing the morphological structure of rat liver tissues,along with the expression of the hepatocellular carcinoma markers,Glypican-3 protein and serum alpha-fetoprotein.Plasma exosomes from each group of rats were isolated using ultracentrifugation.High-throughput sequencing technology was used to screen for differentially expressed miRNAs in rat plasma exosomes.Bioinformatics was used to predict the potential biomarkers through which Jiawei Xiaoyao San exerts its anti-liver cancer effects via liver cancer-derived exosomal miRNAs,followed by functional analysis. RESULTS AND CONCLUSION:(1)Jiawei Xiaoyao San significantly improved the morphological structure of liver tissues in a rat model of liver cancer.Compared with the liver cancer model group,the expression of liver cancer markers Glypican-3 protein and serum alpha-fetoprotein was significantly reduced in the Jiawei Xiaoyao San treatment group.(2)Bioinformatics analysis showed that in the Jiawei Xiaoyao San group,upregulated miR-223-3p in the liver cancer model group had target binding sites with genes E2F1 and NCOA1,which were closely related to liver cancer survival and prognosis.Therefore,Jiawei Xiaoyao San has a therapeutic effect on liver cancer,possibly by targeting negative regulation of NCOA1/E2F1 through liver cancer plasma-derived exosomal miR-223-3p,thereby playing anti-liver cancer effect.
6.Predictive Modeling of Symptomatic Intracranial Hemorrhage Following Endovascular Thrombectomy: Insights From the Nationwide TREAT-AIS Registry
Jia-Hung CHEN ; I-Chang SU ; Yueh-Hsun LU ; Yi-Chen HSIEH ; Chih-Hao CHEN ; Chun-Jen LIN ; Yu-Wei CHEN ; Kuan-Hung LIN ; Pi-Shan SUNG ; Chih-Wei TANG ; Hai-Jui CHU ; Chuan-Hsiu FU ; Chao-Liang CHOU ; Cheng-Yu WEI ; Shang-Yih YAN ; Po-Lin CHEN ; Hsu-Ling YEH ; Sheng-Feng SUNG ; Hon-Man LIU ; Ching-Huang LIN ; Meng LEE ; Sung-Chun TANG ; I-Hui LEE ; Lung CHAN ; Li-Ming LIEN ; Hung-Yi CHIOU ; Jiunn-Tay LEE ; Jiann-Shing JENG ;
Journal of Stroke 2025;27(1):85-94
Background:
and Purpose Symptomatic intracranial hemorrhage (sICH) following endovascular thrombectomy (EVT) is a severe complication associated with adverse functional outcomes and increased mortality rates. Currently, a reliable predictive model for sICH risk after EVT is lacking.
Methods:
This study used data from patients aged ≥20 years who underwent EVT for anterior circulation stroke from the nationwide Taiwan Registry of Endovascular Thrombectomy for Acute Ischemic Stroke (TREAT-AIS). A predictive model including factors associated with an increased risk of sICH after EVT was developed to differentiate between patients with and without sICH. This model was compared existing predictive models using nationwide registry data to evaluate its relative performance.
Results:
Of the 2,507 identified patients, 158 developed sICH after EVT. Factors such as diastolic blood pressure, Alberta Stroke Program Early CT Score, platelet count, glucose level, collateral score, and successful reperfusion were associated with the risk of sICH after EVT. The TREAT-AIS score demonstrated acceptable predictive accuracy (area under the curve [AUC]=0.694), with higher scores being associated with an increased risk of sICH (odds ratio=2.01 per score increase, 95% confidence interval=1.64–2.45, P<0.001). The discriminatory capacity of the score was similar in patients with symptom onset beyond 6 hours (AUC=0.705). Compared to existing models, the TREAT-AIS score consistently exhibited superior predictive accuracy, although this difference was marginal.
Conclusions
The TREAT-AIS score outperformed existing models, and demonstrated an acceptable discriminatory capacity for distinguishing patients according to sICH risk levels. However, the differences between models were only marginal. Further research incorporating periprocedural and postprocedural factors is required to improve the predictive accuracy.
7.Changing antimicrobial resistance profiles of Burkholderia cepacia in hospitals across China:results from CHINET Antimicrobial Resistance Surveillance Program,2015-2021
Chunyue GE ; Yunjian HU ; Xiaoman AI ; Yang YANG ; Fupin HU ; Demei ZHU ; Yingchun XU ; Xiaojiang ZHANG ; Hui LI ; Ping JI ; Yi XIE ; Mei KANG ; Chuanqing WANG ; Pan FU ; Yuanhong XU ; Ying HUANG ; Ziyong SUN ; Zhongju CHEN ; Yuxing NI ; Jingyong SUN ; Yunzhuo CHU ; Sufei TIAN ; Zhidong HU ; Jin LI ; Yunsong YU ; Jie LIN ; Bin SHAN ; Yan DU ; Sufang GUO ; Lianhua WEI ; Fengmei ZOU ; Hong ZHANG ; Chun WANG ; Chao ZHUO ; Danhong SU ; Dawen GUO ; Jinying ZHAO ; Hua YU ; Xiangning HUANG ; Wen'en LIU ; Yanming LI ; Yan JIN ; Chunhong SHAO ; Xuesong XU ; Chao YAN ; Shanmei WANG ; Yafei CHU ; Lixia ZHANG ; Juan MA ; Shuping ZHOU ; Yan ZHOU ; Lei ZHU ; Jinhua MENG ; Fang DONG ; Zhiyong LÜ ; Fangfang HU ; Han SHEN ; Wanqing ZHOU ; Wei JIA ; Gang LI ; Jinsong WU ; Yuemei LU ; Jihong LI ; Jinju DUAN ; Jianbang KANG ; Xiaobo MA ; Yanping ZHENG ; Ruyi GUO ; Yan ZHU ; Yunsheng CHEN ; Qing MENG ; Shifu WANG ; Xuefei HU ; Jilu SHEN ; Wenhui HUANG ; Ruizhong WANG ; Hua FANG ; Bixia YU ; Yong ZHAO ; Ping GONG ; Kaizhen WENG ; Yirong ZHANG ; Jiangshan LIU ; Longfeng LIAO ; Hongqin GU ; Lin JIANG ; Wen HE ; Shunhong XUE ; Jiao FENG ; Chunlei YUE
Chinese Journal of Infection and Chemotherapy 2025;25(5):557-562
Objective To examine the changing prevalence and antimicrobial resistance profiles of Burkholderia cepacia in 52 hospitals across China from 2015 to 2021.Methods A total of 9 261 strains of B.cepacia were collected from 52 hospitals between January 1,2015 and December 31,2021.Antimicrobial susceptibility of the strains was tested using Kirby-Bauer method or automated antimicrobial susceptibility testing systems according to a unified protocol.The results were interpreted according to the breakpoints released in the Clinical & Laboratory Standards Institute(CLSI)guidelines(2023 edition).Results A total of 9 261 strains of B.cepacia were isolated from all age groups,especially elderly patients.The proportion was 11.1%(1 032 strains)in children,significantly lower than the proportion in adults.About half(46.5%,4 310/9 261)of the strains were isolated from patients at least 60 years old and 42.3%(3 919/9 261)of the strains were isolated from young adults.Most isolates(71.1%)were isolated from sputum and respiratory secretions,followed by urine(10.7%)and blood samples(8.1%).B.cepacia isolates were highly susceptible to the five antimicrobial agents recommended in the CLSI M100 document(33rd edition,2023).B.cepacia isolates showed relatively higher resistance rates to meropenem and levofloxacin.However,the resistance rates to ceftazidime,trimethoprim-sulfamethoxazole,and minocycline remained below 8.1%.The percentage of B.cepacia strains resistant to levofloxacin was the highest compared to other antibiotics in any of the three age groups(from 12.4%in the patients<18 years old to 20.6%in the patients aged 60 years or older).Conclusions B.cepacia is one of the clinically important non-fermenting gram-negative bacteria.Accurate and timely reporting of antimicrobial susceptibility test results and ongoing antimicrobial resistance surveillance are helpful for rational prescription of antimicrobial agents and proper prevention and control of nosocomial infections.
8.Predictive value of pre-infarction angina combined with Lp-PLA2 for no-reflow during PCI in eld-erly patients with acute STEMI
Jie-jie MENG ; Ya-dong FENG ; Ya-zhao SUN ; Xin-xin XU ; Chun-lan BAI ; Pei SUN ; Bin LI
Chinese Journal of cardiovascular Rehabilitation Medicine 2025;34(2):167-172
Objective:To investigate the predictive value of pre-infarction angina(PIA)combined with serum lipo-protein-associated phospholipase A2(Lp-PLA2)for no-reflow during primary percutaneous coronary interven-tion(PCI)in elderly patients with new-onset acute ST-segment elevation myocardial infarction(STEMI).Meth-ods:A total of 189 patients who hospitalized because of acute STEMI and underwent primary PCI within 12h in De-partment of Cardiology,Cangzhou People's Hospital between January 2018 and December 2022 were enrolled.Ac-cording to their TIMI blood flow during PCI,the patients were divided into no reflow group(n=42)and normal re-flow group(n=147).The baseline data were compared between two groups.Multivariate Logistic regression analy-sis was used to analyze the risk factors of no-reflow during PCI.The receiver operating characteristic(ROC)curve was plotted to evaluate the predictive value of PIA and Lp-PLA2 for no-reflow.Results:PI A occurred in 73 cases(38.6%),and no reflow occurred in 42 cases(22.2%)during primary PCI.Compared with patients in normal re-flow group,those in no reflow group had significant higher Lp-PLA2[(341.33±98.32)ng/ml vs.(261.95±75.21)ng/ml]and onset to reperfusion time[(7.02±1.28)h vs.(5.14±1.48)h],and significant lower incidence of PIA(23.8% vs.42.9%)(P<0.05 or<0.01).Multivariate Logistic regression analysis showed that Lp-PLA2(OR=1.528,95%CI 1.028~2.030,P<0.001),onset to reperfusion time(OR=2.602,95%CI 1.848~3.665,P<0.001)were independent risk factors for no reflow during PCI in elderly STEMI patients,while PIA was an inde-pendent protective factor(OR=0.261,95%CI 0.101~0.671,P=0.005).The area under ROC curve of Lp-PLA2 combined PIA was 0.863(95%CI 0.806~0.909),which was significantly higher than those of Lp-PLA2[0.733(95%CI 0.664~0.794),Z=2.690,P=0.007]and PIA alone[0.609(95%CI 0.535~0.679),Z=5.657,P<0.001].Conclusion:Pre-infarction angina has an important protective effect on no-reflow in STEMI patients.High Lp-PLA2 and absence of pre-infarction angina at admission may be good predictors of no-reflow during primary PCI in elderly patients with newly-onset acute STEMI,and it contributes to risk stratification of high risk patients.
9.Predictive value of pre-infarction angina combined with Lp-PLA2 for no-reflow during PCI in eld-erly patients with acute STEMI
Jie-jie MENG ; Ya-dong FENG ; Ya-zhao SUN ; Xin-xin XU ; Chun-lan BAI ; Pei SUN ; Bin LI
Chinese Journal of cardiovascular Rehabilitation Medicine 2025;34(2):167-172
Objective:To investigate the predictive value of pre-infarction angina(PIA)combined with serum lipo-protein-associated phospholipase A2(Lp-PLA2)for no-reflow during primary percutaneous coronary interven-tion(PCI)in elderly patients with new-onset acute ST-segment elevation myocardial infarction(STEMI).Meth-ods:A total of 189 patients who hospitalized because of acute STEMI and underwent primary PCI within 12h in De-partment of Cardiology,Cangzhou People's Hospital between January 2018 and December 2022 were enrolled.Ac-cording to their TIMI blood flow during PCI,the patients were divided into no reflow group(n=42)and normal re-flow group(n=147).The baseline data were compared between two groups.Multivariate Logistic regression analy-sis was used to analyze the risk factors of no-reflow during PCI.The receiver operating characteristic(ROC)curve was plotted to evaluate the predictive value of PIA and Lp-PLA2 for no-reflow.Results:PI A occurred in 73 cases(38.6%),and no reflow occurred in 42 cases(22.2%)during primary PCI.Compared with patients in normal re-flow group,those in no reflow group had significant higher Lp-PLA2[(341.33±98.32)ng/ml vs.(261.95±75.21)ng/ml]and onset to reperfusion time[(7.02±1.28)h vs.(5.14±1.48)h],and significant lower incidence of PIA(23.8% vs.42.9%)(P<0.05 or<0.01).Multivariate Logistic regression analysis showed that Lp-PLA2(OR=1.528,95%CI 1.028~2.030,P<0.001),onset to reperfusion time(OR=2.602,95%CI 1.848~3.665,P<0.001)were independent risk factors for no reflow during PCI in elderly STEMI patients,while PIA was an inde-pendent protective factor(OR=0.261,95%CI 0.101~0.671,P=0.005).The area under ROC curve of Lp-PLA2 combined PIA was 0.863(95%CI 0.806~0.909),which was significantly higher than those of Lp-PLA2[0.733(95%CI 0.664~0.794),Z=2.690,P=0.007]and PIA alone[0.609(95%CI 0.535~0.679),Z=5.657,P<0.001].Conclusion:Pre-infarction angina has an important protective effect on no-reflow in STEMI patients.High Lp-PLA2 and absence of pre-infarction angina at admission may be good predictors of no-reflow during primary PCI in elderly patients with newly-onset acute STEMI,and it contributes to risk stratification of high risk patients.
10.Diagnostic and treatment strategies for testicular torsion
Qing-song MENG ; Wan-ze ZHANG ; Ming ZHANG ; Jiang-hua JIA ; Xin WANG ; Wan-li MA ; Yao-hua WANG ; Ya-xuan WANG ; Jin-chun QI
National Journal of Andrology 2025;31(3):222-225
Objective:To investigate the differences between high-frequency ultrasound-guided manual detorsion combined with surgery(MD+S)and surgery alone in the treatment of testicular torsion,and to provide some new evidence for the timely diagno-sis and treatment of the disease.Methods:We retrospectively analyzed the clinical data on 134 cases of unilateral testicular torsion within 48 hours treated in our hospital by MD+S or by surgery alone from January 2015 to May 2022.We statistically analyzed the age distribution,and duration and degrees of testicular torsion,followed by comparison between the two groups.Results:In the 134 ca-ses,the median age of onset was 15(13-19)years old,the median onset-to-visit time was 15(8-25)hours,and the median de-gree of torsion was 360°(180°-1080°).Of the total number of patients,21 underwent testicular excision and the other 113 were treated with the testis preserved,with no statistically significant difference in age distribution between the two groups(P>0.05),and a higher rate of testis resection in those with longer duration and greater angle of torsion(P<0.05).Totally,33 of the patients were assigned to the MD+S group and 101 to the surgery alone group.According to the actual clinical conditions and excluding those with torsion time longer than 24 hours and torsion angle greater than 720 °,28 of the patients underwent ultrasound-guided MD+S(with 1 case of testis resection,3.6%),and 68 received surgery alone(with 7 cases of testis resection,10.3%).The rate of testis resection was higher in the surgery alone than that in the MD+S group,but with no statistically significant difference between the two groups(P>0.05),which was considered to be related to the small sample size in this study.Conclusion:The popularization of testicular torsion knowledge can shorten the onset-to-visit time,and reasonable manual detorsion before emergency surgery can reduce the rate of testis resection.

Result Analysis
Print
Save
E-mail