1.Assessing High-density Y-SNP Panels for Paternal Haplogroup Assignment in Forensic Practice
De-Qin ZHANG ; Chun-Nian WANG ; Lin-Lin LOU ; Meng NI ; Jing GAO ; Jiang HUANG ; Li JIANG
Progress in Biochemistry and Biophysics 2026;53(2):458-469
ObjectiveThe accuracy of Y-chromosome haplogroup assignment is crucial for tracing paternal lineage in male samples. With the advancement of high-throughput sequencing technologies, high-density Y-SNP genotyping from whole-genome or array-based data has become a standard method for determiningY-chromosome haplogroups. This study systematically evaluated the performance of 4 commonly used high-density SNP genotyping systems—namely, the Global Screening Array (GSA), Chinese Genotyping Array (CGA), Affymetrix array, and the 1240K capture panel—for haplogroup assignment. This work provides a reference for data comparison across different systems. MethodsWe extracted genotype data for the 4 Y-SNP panels from 30× whole-genome sequencing (WGS) data of 1 590 male samples from the 1000 Genomes Project. Additionally, GSA array genotype data from 384 relative pairs (spanning 1st- to 12th-degree relationships) from 109 Chinese Han families were collected. Haplogroup assignment was performed using Y-LineageTracker v1.3.0 software. We assessed the concordance and resolution of haplogroup assignments between the four Y-SNP panels and the WGS data. The consistency and resolution of haplogroup assignments were also evaluated for both the 1000 Genomes Project samples and the 109 family samples collected in this study. Furthermore, the impact of varying numbers of Y-SNPs on haplogroup assignment was examined. ResultsThe GSA and CGA panels demonstrated superior resolution and discrimination of haplogroup subclades compared with the other two panels. The haplogroup assignments from the GSA, CGA, and 1240K panels showed high concordance with WGS data, with consistency rates exceeding 88.70%, whereas the Affymetrix platform exhibited a significantly lower consistency rate of 61.89%. Specifically, the GSA and CGA panels consistently demonstrated superior performance compared with the other two panels in the assignment of haplogroups O-M175 and H-L901, achieving complete concordance (100%) for both haplogroups. In contrast, the Affymetrix panel erroneously assigned all individuals belonging to haplogroup O-M175 to haplogroup K2-M526. Furthermore, its accuracy for haplogroup H-L901 was exceedingly low, at merely 1.41%. This poor performance was characterized by the misassignment of 98.59% of H-L901 samples—specifically, 1.41% to J-M304 and a predominant 97.18% to F-M89. For haplogroup R-M207, all four panels exhibited uniformly high levels of consistency, with concordance values exceeding 94.00%. Notably, for haplogroup E-M96, the 1240K and Affymetrix panels outperformed the GSA and CGA panels in terms of concordance, representing the first instance in which these two panels surpassed the latter. Conversely, for haplogroups J-M304, Q-M242, and I-M170, all 4 panels showed relatively elevated misclassification rates, with the Affymetrix array demonstrating the poorest overall performance. None of the four panels showed any discordant haplogroup assignments among the familial relative pairs analyzed. A positive correlation was observed between the number of Y-SNPs (ranging from 1 000 to 10 000) and classification consistency; however, classification consistency plateaued when the number of Y-SNPs exceeded 10 000. Furthermore, a random sampling analysis conducted on the GSA and CGA panels demonstrated that the haplogroup misclassification rate exhibited negligible fluctuation across the Y-SNP range of 500 to 1 000. Conversely, a marked enhancement in classification consistency was observed as the number of markers increased from 1 000 to 5 000, ultimately reaching a plateau within the interval of 5 000 to 8 000 markers. ConclusionThese findings indicate that the GSA and CGA panels provide high resolution and concordance, delivering reliable Y-haplogroup assignment for forensic investigations.
2.Assessing High-density Y-SNP Panels for Paternal Haplogroup Assignment in Forensic Practice
De-Qin ZHANG ; Chun-Nian WANG ; Lin-Lin LOU ; Meng NI ; Jing GAO ; Jiang HUANG ; Li JIANG
Progress in Biochemistry and Biophysics 2026;53(2):458-469
ObjectiveThe accuracy of Y-chromosome haplogroup assignment is crucial for tracing paternal lineage in male samples. With the advancement of high-throughput sequencing technologies, high-density Y-SNP genotyping from whole-genome or array-based data has become a standard method for determiningY-chromosome haplogroups. This study systematically evaluated the performance of 4 commonly used high-density SNP genotyping systems—namely, the Global Screening Array (GSA), Chinese Genotyping Array (CGA), Affymetrix array, and the 1240K capture panel—for haplogroup assignment. This work provides a reference for data comparison across different systems. MethodsWe extracted genotype data for the 4 Y-SNP panels from 30× whole-genome sequencing (WGS) data of 1 590 male samples from the 1000 Genomes Project. Additionally, GSA array genotype data from 384 relative pairs (spanning 1st- to 12th-degree relationships) from 109 Chinese Han families were collected. Haplogroup assignment was performed using Y-LineageTracker v1.3.0 software. We assessed the concordance and resolution of haplogroup assignments between the four Y-SNP panels and the WGS data. The consistency and resolution of haplogroup assignments were also evaluated for both the 1000 Genomes Project samples and the 109 family samples collected in this study. Furthermore, the impact of varying numbers of Y-SNPs on haplogroup assignment was examined. ResultsThe GSA and CGA panels demonstrated superior resolution and discrimination of haplogroup subclades compared with the other two panels. The haplogroup assignments from the GSA, CGA, and 1240K panels showed high concordance with WGS data, with consistency rates exceeding 88.70%, whereas the Affymetrix platform exhibited a significantly lower consistency rate of 61.89%. Specifically, the GSA and CGA panels consistently demonstrated superior performance compared with the other two panels in the assignment of haplogroups O-M175 and H-L901, achieving complete concordance (100%) for both haplogroups. In contrast, the Affymetrix panel erroneously assigned all individuals belonging to haplogroup O-M175 to haplogroup K2-M526. Furthermore, its accuracy for haplogroup H-L901 was exceedingly low, at merely 1.41%. This poor performance was characterized by the misassignment of 98.59% of H-L901 samples—specifically, 1.41% to J-M304 and a predominant 97.18% to F-M89. For haplogroup R-M207, all four panels exhibited uniformly high levels of consistency, with concordance values exceeding 94.00%. Notably, for haplogroup E-M96, the 1240K and Affymetrix panels outperformed the GSA and CGA panels in terms of concordance, representing the first instance in which these two panels surpassed the latter. Conversely, for haplogroups J-M304, Q-M242, and I-M170, all 4 panels showed relatively elevated misclassification rates, with the Affymetrix array demonstrating the poorest overall performance. None of the four panels showed any discordant haplogroup assignments among the familial relative pairs analyzed. A positive correlation was observed between the number of Y-SNPs (ranging from 1 000 to 10 000) and classification consistency; however, classification consistency plateaued when the number of Y-SNPs exceeded 10 000. Furthermore, a random sampling analysis conducted on the GSA and CGA panels demonstrated that the haplogroup misclassification rate exhibited negligible fluctuation across the Y-SNP range of 500 to 1 000. Conversely, a marked enhancement in classification consistency was observed as the number of markers increased from 1 000 to 5 000, ultimately reaching a plateau within the interval of 5 000 to 8 000 markers. ConclusionThese findings indicate that the GSA and CGA panels provide high resolution and concordance, delivering reliable Y-haplogroup assignment for forensic investigations.
3.Cage design-centric glider approach to full-endoscopic lumbar fusion: optimizing nerve root protection in facet-sparing and facet-resecting techniques
Yu-Chia HSU ; Hao-Chun CHUANG ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun-Sung KIM ; Cheng-Li LIN
Asian Spine Journal 2026;20(2):343-353
Endoscopic transforaminal lumbar interbody fusion (TLIF) offers substantial advantages in the management of degenerative spinal diseases, including accelerated postoperative recovery. However, its technical complexity and steep learning curve pose risks for nerve root injury. Optimizing nerve root protection in full-endoscopic facet-sparing TLIF (FE fs-TLIF) and full-endoscopic facet-resecting TLIF (FE fr-TLIF) is essential for enhancing surgical safety. This study aimed to improve the nerve root protection in FE fs-TLIF and FE fr-TLIF by optimizing cage glider selection and insertion techniques based on the specific cage shape—banana-shaped or bullet-shaped. The goal was to ensure safe cage positioning and mitigate nerve root injury during discectomy, endplate preparation, and cage insertion. These strategies were validated through cadaveric simulations and clinical implementation. In FE fr-TLIF utilizing bullet-shaped (straight) cages, one-tip and two-tip cage gliders effectively protected the traversing nerve root by facilitating medial cage entry, thereby minimizing irritation of the exiting nerve root. Conversely, in FE fr-TLIF with banana-shaped cages, the lateral tilt of the cage holder during implantation required the use of a two-tip cage glider to protect the traversing and exiting nerve roots, thereby mitigating the potential risk of nerve irritation. In FE fs-TLIF, a one-tip cage glider is preferred for safeguarding the exiting nerve root, while the traversing root is inherently protected by the medial wall of the facet joint. The use of a two-tip cage glider in FE fs-TLIF can cause injury to the nerve root during glider insertion. In addition to the selection of cage gliders, improper cage insertion steps can also contribute to postoperative neurapraxia. The appropriate selection of cage gliders with corresponding insertion techniques is critical for nerve root protection in endoscopic TLIF. Tailoring these choices to the specific approach (FE fs-TLIF or FE fr-TLIF) and cage type (banana or bullet) enhances surgical safety and clinical outcomes.
4.Research on Electrical Impedance and Microwave Dual-modality Tomography Algorithm Based on Conditional Diffusion Models
Jin-Zhen LIU ; Xiang-Qian MENG ; Hui XIONG ; Li-Min ZHOU ; Chun-Chan LI
Progress in Biochemistry and Biophysics 2026;53(6):1780-1792
ObjectiveStroke poses a heavy burden due to its high mortality and morbidity rates. Accurate and real-time detection of lesions is pivotal for prompt clinical intervention and favorable prognosis. Electrical impedance tomography (EIT) and microwave tomography (MWT) have emerged as compelling alternatives for stroke screening, owing to their non-ionizing, non-invasive and portable nature. EIT provides information on tissue conductivity, and MWT offers high sensitivity to changes in dielectric properties. However, single-modality imaging is inherently limited, EIT suffers from low sensitivity to deep-seated tissues and severe ill-posedness of inverse problems, whereas MWT is challenged by strong nonlinearity in inverse scattering and susceptibility to modeling errors. Consequently, the clinical utility of standalone EIT or MWT for stroke diagnosis remains constrained by poor spatial resolution and imaging artifacts. To improve the accuracy and robustness of stroke imaging, a dual-modality fusion conditional denoising diffusion probabilistic model (DM-DDPM) was proposed for high-precision dual-modality image reconstruction. MethodsA dual-encoder network with a symmetric architecture and independently trained parameters was constructed to extract heterogeneous features separately from EIT boundary voltage measurements and MWT scattered field signals. Attentional feature fusion (AFF) is employed to integrate complementary information from the two modalities adaptively, generating robust fused priors that suppress redundant noise while preserving key physical characteristics. Subsequently, the fused priors are embedded into a Transformer-based diffusion model via a cross attention mechanism to guide the reverse denoising process. This approach effectively reduces artifacts and enhances the stability of conductivity distribution reconstruction. Time step embedding is introduced to enable the network to perceive the diffusion stage and further improve the accuracy of noise prediction. ResultsSimulated experiments demonstrated that DM-DDPM significantly outperforms single-modality and multi-modality networks under various noise levels. A head model simulation dataset was constructed based on COMSOL Multiphysics, and tests were carried out under 50 dB, 40 dB and 30 dB signal-to-noise ratio levels. At 30 dB, the average relative error (RE) was below 0.20, while the structural similarity index measure (SSIM) and correlation coefficient (CC) remained above 0.90 and 0.89, respectively. Compared with single-modality and multi-modality networks, artifacts were significantly reduced, lesion edges were clearer, and localization was more accurate. The model maintains high reconstruction quality and strong robustness for single, double, and triple lesions simultaneously. Furthermore, physical experiments were conducted using a 16-electrode EIT system and a 16-antenna MWT system with asynchronous data acquisition. These experiments confirmed the feasibility of the method in real-world scenarios and demonstrated that it can robustly reconstruct simulated lesions despite environmental interference and measurement noise, validating its reliability for practical clinical applications. ConclusionThe proposed method effectively combines complementary dual-modality information with a conditional diffusion model. Low accuracy and poor noise resistance in single-modality imaging were effectively addressed, while the noise amplification issue caused by direct multimodal data fusion was avoided. The proposed algorithm exhibits strong anti-noise interference ability and high imaging stability in both simulation and physical experiments. Precise localization of stroke lesions with different quantities was achieved, providing a high-precision, and practical technical support for clinical stroke detection.
5.Study on accumulation of polysaccharide and steroid components in Polyporus umbellatus infected by Armillaria spp.
Ming-shu YANG ; Yi-fei YIN ; Juan CHEN ; Bing LI ; Meng-yan HOU ; Chun-yan LENG ; Yong-mei XING ; Shun-xing GUO
Acta Pharmaceutica Sinica 2025;60(1):232-238
In view of the few studies on the influence of
6.The application strategies of non-uniform sampling in the structure elucidation of small molecule compounds—an instantiation using fuziline
Li-li ZHANG ; Ke ZHANG ; Jie LIU ; Chun-wang MENG ; Rui FENG ; Liang XIONG
Acta Pharmaceutica Sinica 2025;60(1):218-224
Two-dimensional nuclear magnetic resonance (2D NMR) is a widely used technique for structural analysis of small molecular compounds. It can obtain information about the hydrogen-hydrogen correlation, hydrogen-carbon single bond correlation, hydrogen-carbon remote correlation, and hydrogen-hydrogen spatial arrangement of compounds. Thus, 2D NMR has an irreplaceable role in the structure elucidation of small molecular products. However, the sample amount of trace components in phytochemical research is very low, and the traditional sampling method (uniform sampling) has problems of poor spectral quality and too long measure time. Increasing the number of scans results in several hours of the acquisition time for a single two-dimensional spectrum, which in turn causes strain on the NMR machine. The non-uniform sampling (NUS) technique can shorten the acquisition time to a large extent and not affect the quality of 2D NMR data, which greatly improves the efficiency of 2D NMR acquisition. In this paper, fuziline, a small molecular compound in the lateral roots of
7.Research on Magnetic Stimulation Intervention Technology for Alzheimer’s Disease Guided by Heart Rate Variability
Shu-Ting CHEN ; Du-Yan GENG ; Chun-Meng FAN ; Wei-Ran ZHENG ; Gui-Zhi XU
Progress in Biochemistry and Biophysics 2025;52(5):1264-1278
ObjectiveNon-invasive magnetic stimulation technology has been widely used in the treatment of Alzheimer’s disease (AD), but there is a lack of convenient and timely methods for evaluating and providing feedback on the effectiveness of the stimulation, which can be used to guide the adjustment of the stimulation protocol. This study aims to explore the possibility of heart rate variability (HRV) in diagnosing AD and guiding AD magnetic stimulation intervention techniques. MethodsIn this study, we used a 40 Hz, 10 mT pulsed magnetic field to expose AD mouse models to whole-body exposure for 18 d, and detected the behavioral and electroencephalographic signals before and after exposure, as well as the instant electrocardiographic signals after exposure every day. ResultsUsing one-way ANOVA and Pearson correlation coefficient analysis, we found that some HRV indicators could identify AD mouse models as accurately as behavioral and electroencephalogram(EEG) changes (P<0.05) and significantly distinguish the severity of the disease (P<0.05), including rMSSD, pNN6, LF/HF, SD1/SD2, and entropy arrangement. These HRV indicators showed good correlation and statistical significance with behavioral and EEG changes (r>0.3, P<0.05); HRV indicators were significantly modulated by the magnetic field exposure before and after the exposure, both of which were observed in the continuous changes of electrocardiogram (ECG) (P<0.05), and the trend of the stimulation effect was more accurately observed in the continuous changes of ECG. ConclusionHRV can accurately reflect the pathophysiological changes and disease degree, quickly evaluate the effect of magnetic stimulation, and has the potential to guide the pattern of magnetic exposure, providing a new idea for the study of personalized electromagnetic neuroregulation technology for brain diseases.
8.Predictive Modeling of Symptomatic Intracranial Hemorrhage Following Endovascular Thrombectomy: Insights From the Nationwide TREAT-AIS Registry
Jia-Hung CHEN ; I-Chang SU ; Yueh-Hsun LU ; Yi-Chen HSIEH ; Chih-Hao CHEN ; Chun-Jen LIN ; Yu-Wei CHEN ; Kuan-Hung LIN ; Pi-Shan SUNG ; Chih-Wei TANG ; Hai-Jui CHU ; Chuan-Hsiu FU ; Chao-Liang CHOU ; Cheng-Yu WEI ; Shang-Yih YAN ; Po-Lin CHEN ; Hsu-Ling YEH ; Sheng-Feng SUNG ; Hon-Man LIU ; Ching-Huang LIN ; Meng LEE ; Sung-Chun TANG ; I-Hui LEE ; Lung CHAN ; Li-Ming LIEN ; Hung-Yi CHIOU ; Jiunn-Tay LEE ; Jiann-Shing JENG ;
Journal of Stroke 2025;27(1):85-94
Background:
and Purpose Symptomatic intracranial hemorrhage (sICH) following endovascular thrombectomy (EVT) is a severe complication associated with adverse functional outcomes and increased mortality rates. Currently, a reliable predictive model for sICH risk after EVT is lacking.
Methods:
This study used data from patients aged ≥20 years who underwent EVT for anterior circulation stroke from the nationwide Taiwan Registry of Endovascular Thrombectomy for Acute Ischemic Stroke (TREAT-AIS). A predictive model including factors associated with an increased risk of sICH after EVT was developed to differentiate between patients with and without sICH. This model was compared existing predictive models using nationwide registry data to evaluate its relative performance.
Results:
Of the 2,507 identified patients, 158 developed sICH after EVT. Factors such as diastolic blood pressure, Alberta Stroke Program Early CT Score, platelet count, glucose level, collateral score, and successful reperfusion were associated with the risk of sICH after EVT. The TREAT-AIS score demonstrated acceptable predictive accuracy (area under the curve [AUC]=0.694), with higher scores being associated with an increased risk of sICH (odds ratio=2.01 per score increase, 95% confidence interval=1.64–2.45, P<0.001). The discriminatory capacity of the score was similar in patients with symptom onset beyond 6 hours (AUC=0.705). Compared to existing models, the TREAT-AIS score consistently exhibited superior predictive accuracy, although this difference was marginal.
Conclusions
The TREAT-AIS score outperformed existing models, and demonstrated an acceptable discriminatory capacity for distinguishing patients according to sICH risk levels. However, the differences between models were only marginal. Further research incorporating periprocedural and postprocedural factors is required to improve the predictive accuracy.
9.Predictive Modeling of Symptomatic Intracranial Hemorrhage Following Endovascular Thrombectomy: Insights From the Nationwide TREAT-AIS Registry
Jia-Hung CHEN ; I-Chang SU ; Yueh-Hsun LU ; Yi-Chen HSIEH ; Chih-Hao CHEN ; Chun-Jen LIN ; Yu-Wei CHEN ; Kuan-Hung LIN ; Pi-Shan SUNG ; Chih-Wei TANG ; Hai-Jui CHU ; Chuan-Hsiu FU ; Chao-Liang CHOU ; Cheng-Yu WEI ; Shang-Yih YAN ; Po-Lin CHEN ; Hsu-Ling YEH ; Sheng-Feng SUNG ; Hon-Man LIU ; Ching-Huang LIN ; Meng LEE ; Sung-Chun TANG ; I-Hui LEE ; Lung CHAN ; Li-Ming LIEN ; Hung-Yi CHIOU ; Jiunn-Tay LEE ; Jiann-Shing JENG ;
Journal of Stroke 2025;27(1):85-94
Background:
and Purpose Symptomatic intracranial hemorrhage (sICH) following endovascular thrombectomy (EVT) is a severe complication associated with adverse functional outcomes and increased mortality rates. Currently, a reliable predictive model for sICH risk after EVT is lacking.
Methods:
This study used data from patients aged ≥20 years who underwent EVT for anterior circulation stroke from the nationwide Taiwan Registry of Endovascular Thrombectomy for Acute Ischemic Stroke (TREAT-AIS). A predictive model including factors associated with an increased risk of sICH after EVT was developed to differentiate between patients with and without sICH. This model was compared existing predictive models using nationwide registry data to evaluate its relative performance.
Results:
Of the 2,507 identified patients, 158 developed sICH after EVT. Factors such as diastolic blood pressure, Alberta Stroke Program Early CT Score, platelet count, glucose level, collateral score, and successful reperfusion were associated with the risk of sICH after EVT. The TREAT-AIS score demonstrated acceptable predictive accuracy (area under the curve [AUC]=0.694), with higher scores being associated with an increased risk of sICH (odds ratio=2.01 per score increase, 95% confidence interval=1.64–2.45, P<0.001). The discriminatory capacity of the score was similar in patients with symptom onset beyond 6 hours (AUC=0.705). Compared to existing models, the TREAT-AIS score consistently exhibited superior predictive accuracy, although this difference was marginal.
Conclusions
The TREAT-AIS score outperformed existing models, and demonstrated an acceptable discriminatory capacity for distinguishing patients according to sICH risk levels. However, the differences between models were only marginal. Further research incorporating periprocedural and postprocedural factors is required to improve the predictive accuracy.
10.Predictive Modeling of Symptomatic Intracranial Hemorrhage Following Endovascular Thrombectomy: Insights From the Nationwide TREAT-AIS Registry
Jia-Hung CHEN ; I-Chang SU ; Yueh-Hsun LU ; Yi-Chen HSIEH ; Chih-Hao CHEN ; Chun-Jen LIN ; Yu-Wei CHEN ; Kuan-Hung LIN ; Pi-Shan SUNG ; Chih-Wei TANG ; Hai-Jui CHU ; Chuan-Hsiu FU ; Chao-Liang CHOU ; Cheng-Yu WEI ; Shang-Yih YAN ; Po-Lin CHEN ; Hsu-Ling YEH ; Sheng-Feng SUNG ; Hon-Man LIU ; Ching-Huang LIN ; Meng LEE ; Sung-Chun TANG ; I-Hui LEE ; Lung CHAN ; Li-Ming LIEN ; Hung-Yi CHIOU ; Jiunn-Tay LEE ; Jiann-Shing JENG ;
Journal of Stroke 2025;27(1):85-94
Background:
and Purpose Symptomatic intracranial hemorrhage (sICH) following endovascular thrombectomy (EVT) is a severe complication associated with adverse functional outcomes and increased mortality rates. Currently, a reliable predictive model for sICH risk after EVT is lacking.
Methods:
This study used data from patients aged ≥20 years who underwent EVT for anterior circulation stroke from the nationwide Taiwan Registry of Endovascular Thrombectomy for Acute Ischemic Stroke (TREAT-AIS). A predictive model including factors associated with an increased risk of sICH after EVT was developed to differentiate between patients with and without sICH. This model was compared existing predictive models using nationwide registry data to evaluate its relative performance.
Results:
Of the 2,507 identified patients, 158 developed sICH after EVT. Factors such as diastolic blood pressure, Alberta Stroke Program Early CT Score, platelet count, glucose level, collateral score, and successful reperfusion were associated with the risk of sICH after EVT. The TREAT-AIS score demonstrated acceptable predictive accuracy (area under the curve [AUC]=0.694), with higher scores being associated with an increased risk of sICH (odds ratio=2.01 per score increase, 95% confidence interval=1.64–2.45, P<0.001). The discriminatory capacity of the score was similar in patients with symptom onset beyond 6 hours (AUC=0.705). Compared to existing models, the TREAT-AIS score consistently exhibited superior predictive accuracy, although this difference was marginal.
Conclusions
The TREAT-AIS score outperformed existing models, and demonstrated an acceptable discriminatory capacity for distinguishing patients according to sICH risk levels. However, the differences between models were only marginal. Further research incorporating periprocedural and postprocedural factors is required to improve the predictive accuracy.

Result Analysis
Print
Save
E-mail