1.The Korean Rectal Cancer Multidisciplinary Committee Clinical Practice Guidelines for Rectal Cancer version 2.0
Hyo Seon RYU ; Hyun Jung KIM ; Dong Hyun KANG ; Yoo-Kang KWAK ; Han Deok KWAK ; Yoon-Hye KWON ; Dalyon KIM ; Baek-Hui KIM ; Jae Hyun KIM ; Ji Hun KIM ; Jin Won KIM ; Tae Hyung KIM ; Hae Young KIM ; Soo Min NAM ; Gyoung Tae NOH ; Jun Woo BONG ; Nak Song SUNG ; Seon Hui SHIN ; Kil-Yong LEE ; Sung Chul LEE ; Sea-Won LEE ; Jung Won LEE ; Jong Min LEE ; Myung Hoon IHN ; Joo Han LIM ; Woong Bae JI ; Dae Hee PYO ; Young Ki HONG ; Jung-Myun KWAK ;
Annals of Coloproctology 2026;42(1):4-33
Rectal cancer, which accounts for approximately 40% of colorectal cancers, remains a major clinical concern. Recent advances in diagnostic imaging, surgical techniques, radiotherapy, and systemic treatment have steadily improved rectal cancer outcomes. Considering this, the Korean Rectal Cancer Multidisciplinary (KRCM) Committee has aimed to provide clinicians and policymakers with up-to-date, evidence-based clinical practice guidelines to support optimal decision-making, reflecting current evidence, the Korean healthcare context, and patient values and preferences. The Clinical Practice Guidelines for Rectal Cancer version 2.0 were developed through multidisciplinary collaboration with related academic societies, building upon and updating the KRCM Clinical Practice Guidelines version 1.0 (titled “Multidisciplinary guidelines for the management of rectal cancer”). These consensus guidelines of the KRCM were established based on a comprehensive literature review, evidence synthesis, with recommendation development guided by the GRADE (Grading of Recommendations Assessment, Development and Evaluation) methodology, and consideration of applicability in real-world clinical practice under the national health insurance system. Each recommendation has been presented with its strength and level of evidence.
2.Periarticular Osteoid Osteoma of the Calcaneus: A Case Report
Kyeong Baek KIM ; Jung Yun BAE ; Suk-Woong KANG ; Won Chul SHIN ; Sang-Min LEE ; Seung Hun WOO
Journal of Korean Foot and Ankle Society 2026;30(2):80-85
Osteoid osteoma accounts for approximately 10% of all benign bone tumors, but only approximately 4% of cases occur in the foot and ankle area. Periarticular osteoid osteoma frequently manifests with nonspecific clinical symptoms that mimic other conditions, potentially leading clinicians down a diagnostic side path and resulting in delayed or missed diagnoses compared to extra-articular osteoid osteoma. Although plain radiographs may show nonspecific findings, magnetic resonance imaging can detect bone marrow edema and surrounding soft tissue changes. Computed tomography is the most accurate modality for diagnosis. This paper reports the case of a 26-year-old female diagnosed with periarticular osteoid osteoma of the calcaneus and was treated with arthroscopic localized curettage at the author’s institution.
3.Profiling of Anti-Signal-Recognition Particle Antibodies and Clinical Characteristics in South Korean Patients With Immune-Mediated Necrotizing Myopathy
Soo-Hyun KIM ; Yunjung CHOI ; Eun Kyoung OH ; Ichizo NISHINO ; Shigeaki SUZUKI ; Bum Chun SUH ; Ha Young SHIN ; Seung Woo KIM ; Byeol-A YOON ; Seong-il OH ; Yoo Hwan KIM ; Hyunjin KIM ; Young-Min LIM ; Seol-Hee BAEK ; Je-Young SHIN ; Hung Youl SEOK ; Seung-Ah LEE ; Young-Chul CHOI ; Hyung Jun PARK
Journal of Clinical Neurology 2025;21(1):31-39
Background:
and Purpose This study evaluated the diagnostic utility of an anti-signal-recognition particle 54 (anti-SRP54) antibody-based enzyme-linked immunosorbent assay (ELISA) as well as the clinical, serological, and pathological characteristics of patients with SRP immune-mediated necrotizing myopathy (IMNM).
Methods:
We evaluated 87 patients with idiopathic inflammatory myopathy and 107 healthy participants between January 2002 and December 2023. The sensitivity and specificity of the ELISA for anti-SRP54 antibodies were assessed, and the clinical profiles of patients with antiSRP54 antibodies were determined.
Results:
The ELISA for anti-SRP54 antibodies had a sensitivity and specificity of 88% and 99%, respectively, along with a test–retest reliability of 0.92 (p<0.001). The 32 patients diagnosed with anti-SRP IMNM using a line-blot immunoassay included 28 (88%) who tested positive for anti-SRP54 antibodies using the ELISA, comprising 12 (43%) males and 16 (57%) females whose median ages at symptom onset and diagnosis were 43.0 years and 43.5 years, respectively. Symptoms included proximal muscle weakness in all 28 (100%) patients, neck weakness in 9 (32%), myalgia in 15 (54%), dysphagia in 5 (18%), dyspnea in 4 (14%), dysarthria in 2 (7%), interstitial lung disease in 2 (7%), and myocarditis in 2 (7%). The median serum creatine kinase (CK) level was 7,261 U/L (interquartile range: 5,086–10,007 U/L), and the median anti-SRP54 antibody level was 2.0 U/mL (interquartile range: 1.0–5.6 U/mL). The serum CK level was significantly higher in patients with coexisting anti-Ro-52 antibodies.
Conclusions
This study has confirmed the reliability of the ELISA for anti-SRP54 antibodies and provided insights into the clinical, serological, and pathological characteristics of South Korean patients with anti-SRP IMNM.
4.Clinical practice guidelines for uterine corpus cancer: an update to the Korean Society of Gynecologic Oncology guidelines
Woo Yeon HWANG ; Ju-Hyun KIM ; Joseph J. NOH ; Min-Hyun BAEK ; Min Chul CHOI ; Yong Jae LEE ; Maria LEE ; Dong Hoon SUH ; Yong Beom KIM ; Dae-Yeon KIM
Journal of Gynecologic Oncology 2025;36(1):e71-
The Korean Society of Gynecologic Oncology has updated its clinical practice guidelines for endometrial cancer to incorporate advancements in recent high-quality randomized controlled trials. These guidelines address evolving treatment paradigms, and are tailored to the Korean medical context. Key updates include a strong recommendation for doxorubicin/trabectedin combination therapy in metastatic or recurrent unresectable leiomyosarcoma based on the significant survival benefits demonstrated in a randomized controlled trial. For advanced or recurrent endometrial cancer, immune checkpoint inhibitors combined with chemotherapy have received strong recommendations, owing to their proven efficacy and increased accessibility in Korea. Conditional recommendations were made for combination therapies involving durvalumab and olaparib, reflecting their potential benefits, but acknowledging regulatory and accessibility constraints. These guidelines aim to provide evidence-based, practical strategies to optimize care for patients with endometrial cancer while addressing unmet clinical needs and adapting global advancements to Korea’s healthcare environment.
5.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
6.Profiling of Anti-Signal-Recognition Particle Antibodies and Clinical Characteristics in South Korean Patients With Immune-Mediated Necrotizing Myopathy
Soo-Hyun KIM ; Yunjung CHOI ; Eun Kyoung OH ; Ichizo NISHINO ; Shigeaki SUZUKI ; Bum Chun SUH ; Ha Young SHIN ; Seung Woo KIM ; Byeol-A YOON ; Seong-il OH ; Yoo Hwan KIM ; Hyunjin KIM ; Young-Min LIM ; Seol-Hee BAEK ; Je-Young SHIN ; Hung Youl SEOK ; Seung-Ah LEE ; Young-Chul CHOI ; Hyung Jun PARK
Journal of Clinical Neurology 2025;21(1):31-39
Background:
and Purpose This study evaluated the diagnostic utility of an anti-signal-recognition particle 54 (anti-SRP54) antibody-based enzyme-linked immunosorbent assay (ELISA) as well as the clinical, serological, and pathological characteristics of patients with SRP immune-mediated necrotizing myopathy (IMNM).
Methods:
We evaluated 87 patients with idiopathic inflammatory myopathy and 107 healthy participants between January 2002 and December 2023. The sensitivity and specificity of the ELISA for anti-SRP54 antibodies were assessed, and the clinical profiles of patients with antiSRP54 antibodies were determined.
Results:
The ELISA for anti-SRP54 antibodies had a sensitivity and specificity of 88% and 99%, respectively, along with a test–retest reliability of 0.92 (p<0.001). The 32 patients diagnosed with anti-SRP IMNM using a line-blot immunoassay included 28 (88%) who tested positive for anti-SRP54 antibodies using the ELISA, comprising 12 (43%) males and 16 (57%) females whose median ages at symptom onset and diagnosis were 43.0 years and 43.5 years, respectively. Symptoms included proximal muscle weakness in all 28 (100%) patients, neck weakness in 9 (32%), myalgia in 15 (54%), dysphagia in 5 (18%), dyspnea in 4 (14%), dysarthria in 2 (7%), interstitial lung disease in 2 (7%), and myocarditis in 2 (7%). The median serum creatine kinase (CK) level was 7,261 U/L (interquartile range: 5,086–10,007 U/L), and the median anti-SRP54 antibody level was 2.0 U/mL (interquartile range: 1.0–5.6 U/mL). The serum CK level was significantly higher in patients with coexisting anti-Ro-52 antibodies.
Conclusions
This study has confirmed the reliability of the ELISA for anti-SRP54 antibodies and provided insights into the clinical, serological, and pathological characteristics of South Korean patients with anti-SRP IMNM.
7.Clinical practice guidelines for uterine corpus cancer: an update to the Korean Society of Gynecologic Oncology guidelines
Woo Yeon HWANG ; Ju-Hyun KIM ; Joseph J. NOH ; Min-Hyun BAEK ; Min Chul CHOI ; Yong Jae LEE ; Maria LEE ; Dong Hoon SUH ; Yong Beom KIM ; Dae-Yeon KIM
Journal of Gynecologic Oncology 2025;36(1):e71-
The Korean Society of Gynecologic Oncology has updated its clinical practice guidelines for endometrial cancer to incorporate advancements in recent high-quality randomized controlled trials. These guidelines address evolving treatment paradigms, and are tailored to the Korean medical context. Key updates include a strong recommendation for doxorubicin/trabectedin combination therapy in metastatic or recurrent unresectable leiomyosarcoma based on the significant survival benefits demonstrated in a randomized controlled trial. For advanced or recurrent endometrial cancer, immune checkpoint inhibitors combined with chemotherapy have received strong recommendations, owing to their proven efficacy and increased accessibility in Korea. Conditional recommendations were made for combination therapies involving durvalumab and olaparib, reflecting their potential benefits, but acknowledging regulatory and accessibility constraints. These guidelines aim to provide evidence-based, practical strategies to optimize care for patients with endometrial cancer while addressing unmet clinical needs and adapting global advancements to Korea’s healthcare environment.
8.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
9.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
10.Profiling of Anti-Signal-Recognition Particle Antibodies and Clinical Characteristics in South Korean Patients With Immune-Mediated Necrotizing Myopathy
Soo-Hyun KIM ; Yunjung CHOI ; Eun Kyoung OH ; Ichizo NISHINO ; Shigeaki SUZUKI ; Bum Chun SUH ; Ha Young SHIN ; Seung Woo KIM ; Byeol-A YOON ; Seong-il OH ; Yoo Hwan KIM ; Hyunjin KIM ; Young-Min LIM ; Seol-Hee BAEK ; Je-Young SHIN ; Hung Youl SEOK ; Seung-Ah LEE ; Young-Chul CHOI ; Hyung Jun PARK
Journal of Clinical Neurology 2025;21(1):31-39
Background:
and Purpose This study evaluated the diagnostic utility of an anti-signal-recognition particle 54 (anti-SRP54) antibody-based enzyme-linked immunosorbent assay (ELISA) as well as the clinical, serological, and pathological characteristics of patients with SRP immune-mediated necrotizing myopathy (IMNM).
Methods:
We evaluated 87 patients with idiopathic inflammatory myopathy and 107 healthy participants between January 2002 and December 2023. The sensitivity and specificity of the ELISA for anti-SRP54 antibodies were assessed, and the clinical profiles of patients with antiSRP54 antibodies were determined.
Results:
The ELISA for anti-SRP54 antibodies had a sensitivity and specificity of 88% and 99%, respectively, along with a test–retest reliability of 0.92 (p<0.001). The 32 patients diagnosed with anti-SRP IMNM using a line-blot immunoassay included 28 (88%) who tested positive for anti-SRP54 antibodies using the ELISA, comprising 12 (43%) males and 16 (57%) females whose median ages at symptom onset and diagnosis were 43.0 years and 43.5 years, respectively. Symptoms included proximal muscle weakness in all 28 (100%) patients, neck weakness in 9 (32%), myalgia in 15 (54%), dysphagia in 5 (18%), dyspnea in 4 (14%), dysarthria in 2 (7%), interstitial lung disease in 2 (7%), and myocarditis in 2 (7%). The median serum creatine kinase (CK) level was 7,261 U/L (interquartile range: 5,086–10,007 U/L), and the median anti-SRP54 antibody level was 2.0 U/mL (interquartile range: 1.0–5.6 U/mL). The serum CK level was significantly higher in patients with coexisting anti-Ro-52 antibodies.
Conclusions
This study has confirmed the reliability of the ELISA for anti-SRP54 antibodies and provided insights into the clinical, serological, and pathological characteristics of South Korean patients with anti-SRP IMNM.

Result Analysis
Print
Save
E-mail