1.Clinical Practice Guideline for the Prehospital Stage of Acute Stroke : III. Initial Decision for Primary Treatment in Subarachnoid Hemorrhage
Jae Sang OH ; Jong Min LEE ; Hong Suk AHN ; Jung-Jae KIM ; Kyoung Min JANG ; Gi-Yong YUN ; Jang Hun KIM ; Dongwook SEO ; Hyeong Jin LEE ; Yuna JO ; Jinwoo JEONG ; Kyoung-Chul CHA ; Yong Soo CHO ; Su Jin KIM ; Jongkyu PARK ; Won-Sang CHO ; Hoon KIM ; Young Woo KIM ; Seung Hun SHEEN ; Sang Weon LEE ; Jae Whan LEE ; Tae Gon KIM ; Sung-kon HA ; Sukh Que PARK ; Dae-Won KIM ; Soon Chan KWON
Journal of Korean Neurosurgical Society 2026;69(1):35-50
Subarachnoid hemorrhage (SAH) is a stroke subtype with high mortality and poor functional outcomes. Prompt occlusion of a ruptured aneurysm at an early stage is crucial to prevent rebleeding, which can result in even higher mortality and more severe disabilities. The most critical initial decision in SAH management is the choice of treatment method with surgical clipping or endovascular coiling. We aimed to develop an evidence-based clinical guideline to select the optimal initial treatment in patients with SAH. We developed this guideline based on evidence from systematic reviews and meta-analyses via a de novo process. A systematic literature review was conducted across four databases (MEDLINE, Embase, Cochrane, and KoreaMed) to answer two population, intervention, comparison, outcome questions comparing clipping and coiling. The risk of bias was assessed using ROB 2.0 and the Newcastle-Ottawa Scale. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses flow diagrams and meta-analyses were generated for functional outcome and mortality. We included six randomized control trials (RCTs) and 58 observational studies. Meta-analysis of RCTs showed that coiling improved functional outcomes compared to clipping (odds ratio [OR], 0.91; 95% confidence interval [CI], 0.86–0.97). No significant mortality difference was observed in RCTs (OR, 1.38; 95% CI, 0.91–2.09), but non-RCTs favored clipping for reduced mortality (OR, 0.77; 95% CI, 0.69–0.86). However, it is difficult to generalize these findings to all clinical situations, as patients with SAH have a highly variable clinical course. Final treatment decision should be tailored to the individual patient’s status, including aneurysm location, morphology, and the expertise available at the treatment center. Such decisions are best made by specialists such as a board-certified physician and should be explained to the patient and their caregivers, along with the rationale for selecting the most appropriate treatment at the given hospital. Korea has many certified endovascular neurosurgeons, cerebrovascular surgeons, and certified cerebrovascular centers. Proper selection of the most suitable treatment method by certified physicians and centers would greatly benefit patient outcomes and healthcare professionals.
2.Clinical Practice Guideline for the Prehospital Stage in Acute Stroke : I. Use of Emergency Medical Services Assessment Tools
Jae Sang OH ; Dongwook SEO ; Jinwoo JEONG ; Kyoung-Chul CHA ; Yong Soo CHO ; Su Jin KIM ; Jongkyu PARK ; Won-Sang CHO ; Se Won OH ; Jang Hun KIM ; Hyeong Jin LEE ; Hong Suk AHN ; Yuna JO ; Jung-Jae KIM ; Kyoung Min JANG ; Gi-Yong YUN ; Jong Min LEE ; Hoon KIM ; Young Woo KIM ; Tae Gon KIM ; Sung-kon HA ; Sukh Que PARK ; Soon Chan KWON
Journal of Korean Neurosurgical Society 2026;69(1):7-22
Accurate and early identification of stroke and large vessel occlusion (LVO) in emergency settings is essential for improving patient outcomes and ensuring the efficient allocation of medical resources. This clinical practice guideline systematically reviews domestic and international literature and conducts meta-analyses to evaluate the utility and diagnostic accuracy of stroke assessment tools used in prehospital emergency medical services (EMS). We developed a guideline based on evidence from systematic reviews and meta-analyses via a de novo process. A systematic literature review was conducted to evaluate the usefulness of diagnostic EMS assessment tools for diagnosing stroke and LVO. Overall, 70 non-randomized control studies were selected for this study. A meta-analysis was conducted with a subgroup analysis to distinguish between patients with stroke and those with LVO. EMS tools demonstrated high sensitivity but low specificity for diagnosing stroke. In the prehospital setting, using validated EMS stroke assessment tools is recommended for the early identification of stroke and LVO. Upon hospital arrival, stroke specialists should conduct further evaluation and triage to confirm the diagnosis and guide appropriate management. Delays in diagnosing LVO are frequently unacceptable. While experts advocate for the use of EMS assessment tools to facilitate early identification of LVO, these tools alone lack adequate sensitivity. Therefore, further diagnostic evaluations and consultation with stroke specialists upon hospital arrival are recommended.
3.Clinical Practice Guidelines for the Prehospital Stage of Acute Stroke in Korea II : Transport Decisions for Patients with Acute Ischemic Stroke
Jae Sang OH ; Yuna JO ; Jong Min LEE ; Hong Suk AHN ; Jung-Jae KIM ; Kyoung Min JANG ; Gi-Yong YUN ; Jang Hun KIM ; Dongwook SEO ; Hyeong Jin LEE ; Jinwoo JEONG ; Kyoung-Chul CHA ; Yong Soo CHO ; Su Jin KIM ; Jongkyu PARK ; Won-Sang CHO ; Hoon KIM ; Young Woo KIM ; Seung Hun SHEEN ; Sang Weon LEE ; Jae Whan LEE ; Tae Gon KIM ; Sung-kon HA ; Sukh Que PARK ; Soon Chan KWON
Journal of Korean Neurosurgical Society 2026;69(1):23-34
The mothership (MS) model, where patients are directly transferred to a thrombectomy-capable center, and the drip-and-ship (DS) model, where thrombolysis is initiated at the nearest primary stroke center before transfer for thrombectomy, are the primary transport modes for patients with stroke. We aimed to establish guidelines for selecting the appropriate transfer strategy based on emergent large vessel occlusion (LVO). We developed this guideline based on evidence from systematic reviews and meta-analyses via a de novo process. A systematic literature review was conducted across four databases (MEDLINE, Embase, Cochrane, and KoreaMed) to answer three Population, Intervention, Comparison, and Outcome questions comparing MS and DS models. The risk of bias was assessed using the Newcastle-Ottawa Scale. Preferred Reporting Items for Systematic Reviews and Meta-Analyses flow diagrams and meta-analyses were generated for functional outcomes, mortality, and successful recanalization. Twenty-six non-randomized controlled studies showed that the MS model improved good functional outcomes by approximately 14% compared with the DS model (odds ratio [OR], 1.14; 95% confidence interval [CI], 1.00–1.30). Fifteen studies reported that mortality in the MS and DS models showed no significant differences (OR, 0.97; 95% CI, 0.84–1.11). Twenty-four studies revealed no significant difference in successful recanalization between the MS and DS models (OR, 0.87; 95% CI, 0.68–1.10). The MS model should be considered first to improve the functional outcome of patients with LVO. However, if thrombectomy cannot be performed immediately after thrombolysis, or if a thrombectomy-enabled hospital is not nearby, the DS model should be considered by stroke specialists depending on transportation time and regional factors. We suggest a mixed approach with the DS model based on specific circumstances or regions to ensure the optimum treatment of patients with acute ischemic stroke (AIS). Appropriate transport for patients with LVO improves the prognosis of AIS.
4.Surgical Outcomes of Weight-Bearing Shoulders:Arthroscopic Rotator Cuff Repair and Reverse Shoulder Arthroplasty
Su Cheol KIM ; Hyun Gon KIM ; Young Girl RHEE ; Sung Min RHEE ; Chul-Hyun CHO ; Du-Han KIM ; Hee Dong LEE ; Jae Chul YOO
Clinics in Orthopedic Surgery 2025;17(3):438-452
Background:
This study aimed to report the short- and midterm outcomes of arthroscopic rotator cuff repair (ARCR) and reverse shoulder arthroplasty (RSA) in weight-bearing shoulders.
Methods:
This retrospective multicenter study included 19 cases of ARCR and 10 cases of RSA performed in weight-bearing shoulders from 2009 to 2021. In the ARCR group, postoperative 6-month magnetic resonance imaging confirmed the tendon integrity. In the RSA group, scapular notching, acromial fracture, and implant failure were assessed using plain radiographs, and complications were recorded. In both groups, preoperative and postoperative range of motion and functional scores were documented, along with subjective satisfaction and arm use for weight-bearing on the shoulders. For patients followed up for > 5 years, a midterm analysis was performed.
Results:
The ARCR group included 8 men and 11 women (average age, 58.8 ± 8.0 years). Initially, Patte types 1, 2, and 3 were noted in 9, 8, and 2 patients, respectively, and 4 patients exhibited full-thickness subscapularis tears. Four patients showed supraspinatus retear, and 2 patients showed subscapularis retear. Retear of any rotator cuff was observed in 5 patients (26.3%). Twelve patients were followed up for > 5 years; 11 (91.7%) used their operated arm for weight-bearing and 9 (75.0%) were satisfied. The RSA group included 5 men and 5 women (average age, 74.3 ± 7.9 years). Procedures included RSAs for cuff tear arthropathy (n = 6), osteoarthritis (n = 3), and fracture nonunion (n = 1). No cases of dislocation, prosthesis loosening, or disassociation were observed throughout the follow-up. However, 1 patient required implant removal due to infection, and 4 patients showed stage 1 scapular notching. Five patients were followed up for > 5 years, all of whom expressed satisfaction and used their operated arms for weight-bearing, despite mean forward flexion (107.5° ± 12.6°) and American Shoulder and Elbow Surgeons score (61.5 ± 5.3) being less than reported patient acceptable symptomatic state (110° and 76, respectively).
Conclusions
Both ARCR and RSA showed promising outcomes in terms of weight-bearing on the operated arm and subjective satisfaction at short- and midterm follow-up. Therefore, neither of these surgeries should be considered contraindicated for patients with weight-bearing shoulder conditions.
5.Surgical Outcomes of Weight-Bearing Shoulders:Arthroscopic Rotator Cuff Repair and Reverse Shoulder Arthroplasty
Su Cheol KIM ; Hyun Gon KIM ; Young Girl RHEE ; Sung Min RHEE ; Chul-Hyun CHO ; Du-Han KIM ; Hee Dong LEE ; Jae Chul YOO
Clinics in Orthopedic Surgery 2025;17(3):438-452
Background:
This study aimed to report the short- and midterm outcomes of arthroscopic rotator cuff repair (ARCR) and reverse shoulder arthroplasty (RSA) in weight-bearing shoulders.
Methods:
This retrospective multicenter study included 19 cases of ARCR and 10 cases of RSA performed in weight-bearing shoulders from 2009 to 2021. In the ARCR group, postoperative 6-month magnetic resonance imaging confirmed the tendon integrity. In the RSA group, scapular notching, acromial fracture, and implant failure were assessed using plain radiographs, and complications were recorded. In both groups, preoperative and postoperative range of motion and functional scores were documented, along with subjective satisfaction and arm use for weight-bearing on the shoulders. For patients followed up for > 5 years, a midterm analysis was performed.
Results:
The ARCR group included 8 men and 11 women (average age, 58.8 ± 8.0 years). Initially, Patte types 1, 2, and 3 were noted in 9, 8, and 2 patients, respectively, and 4 patients exhibited full-thickness subscapularis tears. Four patients showed supraspinatus retear, and 2 patients showed subscapularis retear. Retear of any rotator cuff was observed in 5 patients (26.3%). Twelve patients were followed up for > 5 years; 11 (91.7%) used their operated arm for weight-bearing and 9 (75.0%) were satisfied. The RSA group included 5 men and 5 women (average age, 74.3 ± 7.9 years). Procedures included RSAs for cuff tear arthropathy (n = 6), osteoarthritis (n = 3), and fracture nonunion (n = 1). No cases of dislocation, prosthesis loosening, or disassociation were observed throughout the follow-up. However, 1 patient required implant removal due to infection, and 4 patients showed stage 1 scapular notching. Five patients were followed up for > 5 years, all of whom expressed satisfaction and used their operated arms for weight-bearing, despite mean forward flexion (107.5° ± 12.6°) and American Shoulder and Elbow Surgeons score (61.5 ± 5.3) being less than reported patient acceptable symptomatic state (110° and 76, respectively).
Conclusions
Both ARCR and RSA showed promising outcomes in terms of weight-bearing on the operated arm and subjective satisfaction at short- and midterm follow-up. Therefore, neither of these surgeries should be considered contraindicated for patients with weight-bearing shoulder conditions.
6.Surgical Outcomes of Weight-Bearing Shoulders:Arthroscopic Rotator Cuff Repair and Reverse Shoulder Arthroplasty
Su Cheol KIM ; Hyun Gon KIM ; Young Girl RHEE ; Sung Min RHEE ; Chul-Hyun CHO ; Du-Han KIM ; Hee Dong LEE ; Jae Chul YOO
Clinics in Orthopedic Surgery 2025;17(3):438-452
Background:
This study aimed to report the short- and midterm outcomes of arthroscopic rotator cuff repair (ARCR) and reverse shoulder arthroplasty (RSA) in weight-bearing shoulders.
Methods:
This retrospective multicenter study included 19 cases of ARCR and 10 cases of RSA performed in weight-bearing shoulders from 2009 to 2021. In the ARCR group, postoperative 6-month magnetic resonance imaging confirmed the tendon integrity. In the RSA group, scapular notching, acromial fracture, and implant failure were assessed using plain radiographs, and complications were recorded. In both groups, preoperative and postoperative range of motion and functional scores were documented, along with subjective satisfaction and arm use for weight-bearing on the shoulders. For patients followed up for > 5 years, a midterm analysis was performed.
Results:
The ARCR group included 8 men and 11 women (average age, 58.8 ± 8.0 years). Initially, Patte types 1, 2, and 3 were noted in 9, 8, and 2 patients, respectively, and 4 patients exhibited full-thickness subscapularis tears. Four patients showed supraspinatus retear, and 2 patients showed subscapularis retear. Retear of any rotator cuff was observed in 5 patients (26.3%). Twelve patients were followed up for > 5 years; 11 (91.7%) used their operated arm for weight-bearing and 9 (75.0%) were satisfied. The RSA group included 5 men and 5 women (average age, 74.3 ± 7.9 years). Procedures included RSAs for cuff tear arthropathy (n = 6), osteoarthritis (n = 3), and fracture nonunion (n = 1). No cases of dislocation, prosthesis loosening, or disassociation were observed throughout the follow-up. However, 1 patient required implant removal due to infection, and 4 patients showed stage 1 scapular notching. Five patients were followed up for > 5 years, all of whom expressed satisfaction and used their operated arms for weight-bearing, despite mean forward flexion (107.5° ± 12.6°) and American Shoulder and Elbow Surgeons score (61.5 ± 5.3) being less than reported patient acceptable symptomatic state (110° and 76, respectively).
Conclusions
Both ARCR and RSA showed promising outcomes in terms of weight-bearing on the operated arm and subjective satisfaction at short- and midterm follow-up. Therefore, neither of these surgeries should be considered contraindicated for patients with weight-bearing shoulder conditions.
7.Surgical Outcomes of Weight-Bearing Shoulders:Arthroscopic Rotator Cuff Repair and Reverse Shoulder Arthroplasty
Su Cheol KIM ; Hyun Gon KIM ; Young Girl RHEE ; Sung Min RHEE ; Chul-Hyun CHO ; Du-Han KIM ; Hee Dong LEE ; Jae Chul YOO
Clinics in Orthopedic Surgery 2025;17(3):438-452
Background:
This study aimed to report the short- and midterm outcomes of arthroscopic rotator cuff repair (ARCR) and reverse shoulder arthroplasty (RSA) in weight-bearing shoulders.
Methods:
This retrospective multicenter study included 19 cases of ARCR and 10 cases of RSA performed in weight-bearing shoulders from 2009 to 2021. In the ARCR group, postoperative 6-month magnetic resonance imaging confirmed the tendon integrity. In the RSA group, scapular notching, acromial fracture, and implant failure were assessed using plain radiographs, and complications were recorded. In both groups, preoperative and postoperative range of motion and functional scores were documented, along with subjective satisfaction and arm use for weight-bearing on the shoulders. For patients followed up for > 5 years, a midterm analysis was performed.
Results:
The ARCR group included 8 men and 11 women (average age, 58.8 ± 8.0 years). Initially, Patte types 1, 2, and 3 were noted in 9, 8, and 2 patients, respectively, and 4 patients exhibited full-thickness subscapularis tears. Four patients showed supraspinatus retear, and 2 patients showed subscapularis retear. Retear of any rotator cuff was observed in 5 patients (26.3%). Twelve patients were followed up for > 5 years; 11 (91.7%) used their operated arm for weight-bearing and 9 (75.0%) were satisfied. The RSA group included 5 men and 5 women (average age, 74.3 ± 7.9 years). Procedures included RSAs for cuff tear arthropathy (n = 6), osteoarthritis (n = 3), and fracture nonunion (n = 1). No cases of dislocation, prosthesis loosening, or disassociation were observed throughout the follow-up. However, 1 patient required implant removal due to infection, and 4 patients showed stage 1 scapular notching. Five patients were followed up for > 5 years, all of whom expressed satisfaction and used their operated arms for weight-bearing, despite mean forward flexion (107.5° ± 12.6°) and American Shoulder and Elbow Surgeons score (61.5 ± 5.3) being less than reported patient acceptable symptomatic state (110° and 76, respectively).
Conclusions
Both ARCR and RSA showed promising outcomes in terms of weight-bearing on the operated arm and subjective satisfaction at short- and midterm follow-up. Therefore, neither of these surgeries should be considered contraindicated for patients with weight-bearing shoulder conditions.
8.Comparison of Clinical Outcomes between Drug-Eluting Balloons and Drug-Eluting Stents in Patients with Small Coronary Artery Disease
Man Su KIM ; Seong Ho PARK ; Seok OH ; Dae Yong HYUN ; Seung Hun LEE ; Yong Hwan LIM ; Jun Ho AHN ; Kyung Hoon CHO ; Min Chul KIM ; Doo Sun SIM ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Myung Ho JEONG
Korean Journal of Medicine 2024;99(5):253-262
Background/Aims:
Drug-eluting balloons (DEBs) represent a novel therapeutic approach for patients with small coronary artery disease. However, further studies are needed to compare the clinical efficacy of DEBs versus drug-eluting stents (DESs).
Methods:
In total, 492 patients (age, 67.9 ± 11.0 years; 339 men) with small coronary artery lesions (diameter < 2.75 mm) were randomly assigned to group I (DEB) (n = 104; age, 67.2 ± 10.7 years; 83 men) and group II (DES) (n = 388; age, 68.0 ± 11.1 years; 254 men). For inverse probability of treatment weighting (IPTW) analysis, the study population was stratified into groups I (n = 269) and II (n = 280). We compared the incidences of major adverse cardiac events (MACE) between the two groups during 12 months of clinical follow-up.
Results:
Group I had shorter device lengths (22.4 ± 5.8 mm) compared with group II (27.4 ± 9.3 mm; p < 0.001). Additionally, devices in group I were smaller in diameter (2.4 ± 0.1 mm) compared with those in group II (2.6 ± 0.1 mm; p < 0.001). Left ventricular ejection fraction (LVEF) was lower in group I (53.8% ± 12.6%) than in group II (58.6% ± 11.9%; p < 0.001). After IPTW, no significant differences in LVEF were observed between groups I and II. During 12 months of follow-up, the incidence of total MACE did not differ between the two groups.
Conclusions
No significant differences were observed in clinical efficacy between DEB and DES for the treatment of small coronary artery disease. Therefore, DEB can be considered a viable alternative to DES in patients with small coronary artery disease.
9.Evaluating the Influence of Scan Timing on Dosimetric Accuracy in EBT3 and EBT4 Radiochromic Films
Jin Dong CHO ; Su Chul HAN ; Jason Joon Bock LEE ; Hyebin LEE ; Heerim NAM
Progress in Medical Physics 2024;35(4):135-144
Purpose:
This study compares the dosimetric properties of EBT3 and EBT4 GAFchromic films in transmission and reflection scanning modes, focusing on dose response, sensitivity, and postirradiation stability.
Methods:
The EBT3 and EBT4 films were irradiated at doses of 0–10 Gy using a Varian TrueBeam linear accelerator at 6 MV. The films were scanned at intervals between 1 and 336 hours after irradiation in both transmission and reflection modes. Net optical density (NetOD) values from each scan were used to evaluate dose response and sensitivity, with calibration curves created for each film and scan mode. Dose differences between calculated and delivered doses were assessed over time.
Results:
The EBT3 and EBT4 films exhibited similar dose–response curves and stable NetOD values across both scanning modes. However, EBT4 exhibited reduced sensitivity variability in response to dose changes. After irradiation, NetOD values increased up to 24 hours before stabilizing, suggesting that a 24-hour scan time is sufficient for consistent measurements. Dose differences between films and modes remained within ±4%.
Conclusions
EBT4 offers comparable dosimetric performance to EBT3, with additional benefits, such as improved dose–response linearity and reduced sensitivity fluctuations. The findings indicate that EBT4 can serve as a reliable successor to EBT3.
10.Evaluating the Influence of Scan Timing on Dosimetric Accuracy in EBT3 and EBT4 Radiochromic Films
Jin Dong CHO ; Su Chul HAN ; Jason Joon Bock LEE ; Hyebin LEE ; Heerim NAM
Progress in Medical Physics 2024;35(4):135-144
Purpose:
This study compares the dosimetric properties of EBT3 and EBT4 GAFchromic films in transmission and reflection scanning modes, focusing on dose response, sensitivity, and postirradiation stability.
Methods:
The EBT3 and EBT4 films were irradiated at doses of 0–10 Gy using a Varian TrueBeam linear accelerator at 6 MV. The films were scanned at intervals between 1 and 336 hours after irradiation in both transmission and reflection modes. Net optical density (NetOD) values from each scan were used to evaluate dose response and sensitivity, with calibration curves created for each film and scan mode. Dose differences between calculated and delivered doses were assessed over time.
Results:
The EBT3 and EBT4 films exhibited similar dose–response curves and stable NetOD values across both scanning modes. However, EBT4 exhibited reduced sensitivity variability in response to dose changes. After irradiation, NetOD values increased up to 24 hours before stabilizing, suggesting that a 24-hour scan time is sufficient for consistent measurements. Dose differences between films and modes remained within ±4%.
Conclusions
EBT4 offers comparable dosimetric performance to EBT3, with additional benefits, such as improved dose–response linearity and reduced sensitivity fluctuations. The findings indicate that EBT4 can serve as a reliable successor to EBT3.

Result Analysis
Print
Save
E-mail