1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Changes of cardiovascular function and quality of life in patients with chronic heart failure after medi-cal community homogenization management
Yan XU ; Lin XUE ; Yan-chuan WANG ; Yuan-yuan SHU ; Ya-mei WANG
Chinese Journal of cardiovascular Rehabilitation Medicine 2025;34(2):241-246
Objective:To investigate the effect of medical community homogenization management(MCHM)on self-care ability,heart function,vascular endothelial function and quality of life in patients with chronic heart failure(CHF).Methods:This randomized controlled study enrolled 110 CHF patients admitted in Panzhihua Central Hos-pital between April 2021 and April 2023.They were divided into intervention group(n=55)and routine group(n=55).The control group received routine management,while intervention group received additional MCHM,both groups were intervened for 3 months.Self-care ability,heart function,vascular endothelial function,quality of life and incidence of adverse events were compared between two groups.Results:Compared with patients in control group,those in intervention group had significant higher total score of self-care of heart failure index(SCHFI)[(82.30±2.98)points vs.(59.46±3.19)points],stroke volume(SV)[(73.30±2.31)ml vs.(54.66±1.96)ml],left ventricular ejection fraction(LVEF)[(58.25±2.90)% vs.(52.41±2.52)%],early diastolic peak flow velocity/late diastolic peak flow velocity(E/A)[(1.95±0.18)vs.(1.30±0.16)]and the level of nitric oxide(NO)[(106.70±4.44)μmol/L vs.(82.36±4.66)μmol/L](P<0.001 all),and significant lower left ventricular end-diastolic diameter(LVEDd)[(49.79±1.58)mm vs.(56.49±2.17)mm],endothelin-1(ET-1)[(36.66±2.65)ng/L vs.(46.88±2.66)ng/L],Minnesota living with heart failure questionnaire(MLHFQ)total score[(36.12±3.23)points vs.(54.67±3.35)points](P<0.001 all).Patients in intervention group had significant lower incidence of adverse events comparing to those in control group(7.27% vs.25.45%,P=0.010).Conclu-sion:Medical community homogenization management could significantly improve self-care ability,heart func-tion,vascular endothelial function and quality of life with good safety in CHF patients.
7.circHERC4_041 Inhibits the Fibrotic Phenotype of Cardiac Fibroblasts by Encoding Protein
Yuan GAO ; Chuan-Meng ZHOU ; Hua-Yan WU ; Ya WANG ; Ru-Shi WU ; Pei-Ying GUAN ; Jun-Tao FANG ; Jin-Dong XU ; Yu-Peng LIU ; Zhi-Qin HU ; Zhi-Xin SHAN
Chinese Journal of Biochemistry and Molecular Biology 2025;41(3):393-403
A mounting body of research suggests that circRNAs significantly contribute to the develop-ment of myocardial fibrosis.The microarray results of human circular RNA expression profile indicated that circHERC4_041 expression increased in the myocardium of patients with heart failure,RT-qPCR a-nalysis confirmed that the myocardial expression level of circHERC4_041 in individuals with heart failure were considerably elevated compared to that in healthy organ donors.Fluorescence in situ hybridization(FISH)confirmed that circHERC4_041 was abundant in the cytoplasm of human cardiomyocyte AC16.Overexpression of circHERC4_041 in mouse myocardial fibroblasts(mCFs)mediated by adenovirus in-hibited the expression of fibrosis-related proteins in mCFs.Experiments involving cell proliferation,wound healing,and Transwell assays demonstrated that overexpression of circHERC4_041 suppressed the growth and mobility of mCFs(P<0.001).Sequence analysis results suggested that circHERC4_041 con-tains potential ribosome entry sequence(IRES)and open reading frame(ORF).Western blot confirmed that circHERC4_041 could translate the 516 amino acid HERC4-516aa protein,which was mainly located in the cytoplasm of the cell.Cell functional experiments confirmed that circHERC4_041 inhibited the fi-brotic phenotype of mCFs by specifically translating HERC4-516aa(P<0.05).The specific interaction between HERC4-516aa and transglutaminase 2(TGM2)was confirmed by IP-MS screening and Co-IP i-dentification.Further results found that the degradation of TGM2 was promoted through proteasome path-way.The overexpression of TGM2 in mCFs facilitated by adenoviral vectors could counteract the suppres-sive effects of HERC4-516aa on the fibrotic phenotype of mCFs.Therefore,this study confirmed that the HERC4-516aa protein translated by circHERC4_041 can specifically bind to TGM2 to inhibit the fibrotic phenotype of myocardial fibroblasts.
8.Changes of cardiovascular function and quality of life in patients with chronic heart failure after medi-cal community homogenization management
Yan XU ; Lin XUE ; Yan-chuan WANG ; Yuan-yuan SHU ; Ya-mei WANG
Chinese Journal of cardiovascular Rehabilitation Medicine 2025;34(2):241-246
Objective:To investigate the effect of medical community homogenization management(MCHM)on self-care ability,heart function,vascular endothelial function and quality of life in patients with chronic heart failure(CHF).Methods:This randomized controlled study enrolled 110 CHF patients admitted in Panzhihua Central Hos-pital between April 2021 and April 2023.They were divided into intervention group(n=55)and routine group(n=55).The control group received routine management,while intervention group received additional MCHM,both groups were intervened for 3 months.Self-care ability,heart function,vascular endothelial function,quality of life and incidence of adverse events were compared between two groups.Results:Compared with patients in control group,those in intervention group had significant higher total score of self-care of heart failure index(SCHFI)[(82.30±2.98)points vs.(59.46±3.19)points],stroke volume(SV)[(73.30±2.31)ml vs.(54.66±1.96)ml],left ventricular ejection fraction(LVEF)[(58.25±2.90)% vs.(52.41±2.52)%],early diastolic peak flow velocity/late diastolic peak flow velocity(E/A)[(1.95±0.18)vs.(1.30±0.16)]and the level of nitric oxide(NO)[(106.70±4.44)μmol/L vs.(82.36±4.66)μmol/L](P<0.001 all),and significant lower left ventricular end-diastolic diameter(LVEDd)[(49.79±1.58)mm vs.(56.49±2.17)mm],endothelin-1(ET-1)[(36.66±2.65)ng/L vs.(46.88±2.66)ng/L],Minnesota living with heart failure questionnaire(MLHFQ)total score[(36.12±3.23)points vs.(54.67±3.35)points](P<0.001 all).Patients in intervention group had significant lower incidence of adverse events comparing to those in control group(7.27% vs.25.45%,P=0.010).Conclu-sion:Medical community homogenization management could significantly improve self-care ability,heart func-tion,vascular endothelial function and quality of life with good safety in CHF patients.
9.circHERC4_041 Inhibits the Fibrotic Phenotype of Cardiac Fibroblasts by Encoding Protein
Yuan GAO ; Chuan-Meng ZHOU ; Hua-Yan WU ; Ya WANG ; Ru-Shi WU ; Pei-Ying GUAN ; Jun-Tao FANG ; Jin-Dong XU ; Yu-Peng LIU ; Zhi-Qin HU ; Zhi-Xin SHAN
Chinese Journal of Biochemistry and Molecular Biology 2025;41(3):393-403
A mounting body of research suggests that circRNAs significantly contribute to the develop-ment of myocardial fibrosis.The microarray results of human circular RNA expression profile indicated that circHERC4_041 expression increased in the myocardium of patients with heart failure,RT-qPCR a-nalysis confirmed that the myocardial expression level of circHERC4_041 in individuals with heart failure were considerably elevated compared to that in healthy organ donors.Fluorescence in situ hybridization(FISH)confirmed that circHERC4_041 was abundant in the cytoplasm of human cardiomyocyte AC16.Overexpression of circHERC4_041 in mouse myocardial fibroblasts(mCFs)mediated by adenovirus in-hibited the expression of fibrosis-related proteins in mCFs.Experiments involving cell proliferation,wound healing,and Transwell assays demonstrated that overexpression of circHERC4_041 suppressed the growth and mobility of mCFs(P<0.001).Sequence analysis results suggested that circHERC4_041 con-tains potential ribosome entry sequence(IRES)and open reading frame(ORF).Western blot confirmed that circHERC4_041 could translate the 516 amino acid HERC4-516aa protein,which was mainly located in the cytoplasm of the cell.Cell functional experiments confirmed that circHERC4_041 inhibited the fi-brotic phenotype of mCFs by specifically translating HERC4-516aa(P<0.05).The specific interaction between HERC4-516aa and transglutaminase 2(TGM2)was confirmed by IP-MS screening and Co-IP i-dentification.Further results found that the degradation of TGM2 was promoted through proteasome path-way.The overexpression of TGM2 in mCFs facilitated by adenoviral vectors could counteract the suppres-sive effects of HERC4-516aa on the fibrotic phenotype of mCFs.Therefore,this study confirmed that the HERC4-516aa protein translated by circHERC4_041 can specifically bind to TGM2 to inhibit the fibrotic phenotype of myocardial fibroblasts.
10.A multicenter study of neonatal stroke in Shenzhen,China
Li-Xiu SHI ; Jin-Xing FENG ; Yan-Fang WEI ; Xin-Ru LU ; Yu-Xi ZHANG ; Lin-Ying YANG ; Sheng-Nan HE ; Pei-Juan CHEN ; Jing HAN ; Cheng CHEN ; Hui-Ying TU ; Zhang-Bin YU ; Jin-Jie HUANG ; Shu-Juan ZENG ; Wan-Ling CHEN ; Ying LIU ; Yan-Ping GUO ; Jiao-Yu MAO ; Xiao-Dong LI ; Qian-Shen ZHANG ; Zhi-Li XIE ; Mei-Ying HUANG ; Kun-Shan YAN ; Er-Ya YING ; Jun CHEN ; Yan-Rong WANG ; Ya-Ping LIU ; Bo SONG ; Hua-Yan LIU ; Xiao-Dong XIAO ; Hong TANG ; Yu-Na WANG ; Yin-Sha CAI ; Qi LONG ; Han-Qiang XU ; Hui-Zhan WANG ; Qian SUN ; Fang HAN ; Rui-Biao ZHANG ; Chuan-Zhong YANG ; Lei DOU ; Hui-Ju SHI ; Rui WANG ; Ping JIANG ; Shenzhen Neonatal Data Network
Chinese Journal of Contemporary Pediatrics 2024;26(5):450-455
Objective To investigate the incidence rate,clinical characteristics,and prognosis of neonatal stroke in Shenzhen,China.Methods Led by Shenzhen Children's Hospital,the Shenzhen Neonatal Data Collaboration Network organized 21 institutions to collect 36 cases of neonatal stroke from January 2020 to December 2022.The incidence,clinical characteristics,treatment,and prognosis of neonatal stroke in Shenzhen were analyzed.Results The incidence rate of neonatal stroke in 21 hospitals from 2020 to 2022 was 1/15 137,1/6 060,and 1/7 704,respectively.Ischemic stroke accounted for 75%(27/36);boys accounted for 64%(23/36).Among the 36 neonates,31(86%)had disease onset within 3 days after birth,and 19(53%)had convulsion as the initial presentation.Cerebral MRI showed that 22 neonates(61%)had left cerebral infarction and 13(36%)had basal ganglia infarction.Magnetic resonance angiography was performed for 12 neonates,among whom 9(75%)had involvement of the middle cerebral artery.Electroencephalography was performed for 29 neonates,with sharp waves in 21 neonates(72%)and seizures in 10 neonates(34%).Symptomatic/supportive treatment varied across different hospitals.Neonatal Behavioral Neurological Assessment was performed for 12 neonates(33%,12/36),with a mean score of(32±4)points.The prognosis of 27 neonates was followed up to around 12 months of age,with 44%(12/27)of the neonates having a good prognosis.Conclusions Ischemic stroke is the main type of neonatal stroke,often with convulsions as the initial presentation,involvement of the middle cerebral artery,sharp waves on electroencephalography,and a relatively low neurodevelopment score.Symptomatic/supportive treatment is the main treatment method,and some neonates tend to have a poor prognosis.

Result Analysis
Print
Save