1.Design, synthesis and evaluation of oxadiazoles as novel XO inhibitors
Hong-zhan WANG ; Ya-jun YANG ; Ying YANG ; Fei YE ; Jin-ying TIAN ; Chuan-ming ZHANG ; Zhi-yan XIAO
Acta Pharmaceutica Sinica 2025;60(1):164-171
Xanthine oxidase (XO) is an important therapeutic target for the treatment of hyperuricemia and gout. Based on the previously identified potent XO inhibitor
2.Carbon footprint accounting of traditional Chinese medicine extracts based on life cycle assessment: a case study of mulberry leaf extract from an enterprise.
Zhi-Min CI ; Jian-Xiang OU ; Qiang YU ; Chuan ZHENG ; Zhao-Qing PEI ; Li-Ping QU ; Ming YANG ; Li HAN ; Ding-Kun ZHANG
China Journal of Chinese Materia Medica 2025;50(1):120-129
Under the background of carbon peaking and carbon neutrality goals, the Ministry of Ecology and Environment, together with 15 national ministries and commissions, has formulated the Implementation Plan on Establishing a Carbon Footprint Management System, and it is urgent for traditional Chinese medicine(TCM) pharmaceutical enterprises to carry out research on carbon footprint accounting methods of related products. Based on the life cycle assessment(LCA) theory, taking mulberry leaf extract produced by a certain enterprise as an example, this study analyzed the carbon footprint of TCM extracts during the life cycle. The results show that for every 1 kg of product produced, the carbon emissions from the stages of raw material acquisition, transportation, and extract production are-20.569, 1.205, and 173.577 kgCO_2eq(CO_2 equivalent), respectively. The carbon footprint of the product is 154.213 kgCO_2eq·kg~(-1). In addition, the carbon emission is the highest in the production stage, in which the consumption of ethanol solvents makes the greatest contribution to the carbon footprint, accounting for 25.71%, more than one-fourth of the total carbon footprint. The second contribution was from the treatment process of TCM residues, accounting for 19.67%, closely followed by wastewater treatment(17.71%), the consumption of hot steam(17.43%), and drinking water(16.90%). The consumption of electric power and packaging materials has a smaller carbon emission of 2.58%. In particular, the carbon emission caused by the consumption of packaging materials is only 0.04%, which is negligible. The results of the study are expected to provide a reference for TCM enterprises to carry out research on the carbon footprint of products, offer ideas for collaborative innovation in reducing pollution and carbon emissions throughout the entire industry chain of TCM, and develop new quality productivity of modern TCM industry based on green and low-carbon manufacturing.
Morus/chemistry*
;
Plant Leaves/chemistry*
;
Carbon Footprint
;
Drugs, Chinese Herbal/chemistry*
;
Plant Extracts/analysis*
;
Medicine, Chinese Traditional
3.Grounded theory, scientific connotation, and clinical application of aromatic immunity in traditional Chinese medicine.
Si-Rui XIANG ; Qin JIAN ; Qi XU ; Jun-Zhi LIN ; Ding-Kun ZHANG ; Ming YANG ; Chuan ZHENG
China Journal of Chinese Materia Medica 2025;50(5):1137-1145
Aromatic immunity in traditional Chinese medicine(TCM) is the medical knowledge accumulated in the process of people's struggling with diseases. It plays an important role in plague prevention, disease treatment, health preservation, and rehabilitation, and has profound TCM basic theoretical support and abundant modern scientific evidence. With the in-depth promotion of the Healthy China initiative and the succession of health needs in the post-COVID-19 era, how to practice the health concept of aromatic immunity in TCM and develop its health service resources with high quality has become an important proposition to be discussed urgently. This paper summarizes the cognitive process, puts forward the basic concept, discusses the scientific connotation and clinical application value, and looks forward to the future development trend of aromatic immunity in TCM, aiming to provide guidance for the development of great health products and promote the application of aromatic immunity in TCM in serving people's health.
Medicine, Chinese Traditional/methods*
;
Humans
;
COVID-19/immunology*
;
China
;
Drugs, Chinese Herbal/therapeutic use*
;
SARS-CoV-2
4.Glucocorticoid Discontinuation in Patients with Rheumatoid Arthritis under Background of Chinese Medicine: Challenges and Potentials Coexist.
Chuan-Hui YAO ; Chi ZHANG ; Meng-Ge SONG ; Cong-Min XIA ; Tian CHANG ; Xie-Li MA ; Wei-Xiang LIU ; Zi-Xia LIU ; Jia-Meng LIU ; Xiao-Po TANG ; Ying LIU ; Jian LIU ; Jiang-Yun PENG ; Dong-Yi HE ; Qing-Chun HUANG ; Ming-Li GAO ; Jian-Ping YU ; Wei LIU ; Jian-Yong ZHANG ; Yue-Lan ZHU ; Xiu-Juan HOU ; Hai-Dong WANG ; Yong-Fei FANG ; Yue WANG ; Yin SU ; Xin-Ping TIAN ; Ai-Ping LYU ; Xun GONG ; Quan JIANG
Chinese journal of integrative medicine 2025;31(7):581-589
OBJECTIVE:
To evaluate the dynamic changes of glucocorticoid (GC) dose and the feasibility of GC discontinuation in rheumatoid arthritis (RA) patients under the background of Chinese medicine (CM).
METHODS:
This multicenter retrospective cohort study included 1,196 RA patients enrolled in the China Rheumatoid Arthritis Registry of Patients with Chinese Medicine (CERTAIN) from September 1, 2019 to December 4, 2023, who initiated GC therapy. Participants were divided into the Western medicine (WM) and integrative medicine (IM, combination of CM and WM) groups based on medication regimen. Follow-up was performed at least every 3 months to assess dynamic changes in GC dose. Changes in GC dose were analyzed by generalized estimator equation, the probability of GC discontinuation was assessed using Kaplan-Meier curve, and predictors of GC discontinuation were analyzed by Cox regression. Patients with <12 months of follow-up were excluded for the sensitivity analysis.
RESULTS:
Among 1,196 patients (85.4% female; median age 56.4 years), 880 (73.6%) received IM. Over a median 12-month follow-up, 34.3% (410 cases) discontinued GC, with significantly higher rates in the IM group (40.8% vs. 16.1% in WM; P<0.05). GC dose declined progressively, with IM patients demonstrating faster reductions (median 3.75 mg vs. 5.00 mg in WM at 12 months; P<0.05). Multivariate Cox analysis identified age <60 years [P<0.001, hazard ratios (HR)=2.142, 95% confidence interval (CI): 1.523-3.012], IM therapy (P=0.001, HR=2.175, 95% CI: 1.369-3.456), baseline GC dose ⩽7.5 mg (P=0.003, HR=1.637, 95% CI: 1.177-2.275), and absence of non-steroidal anti-inflammatory drugs use (P=0.001, HR=2.546, 95% CI: 1.432-4.527) as significant predictors of GC discontinuation. Sensitivity analysis (545 cases) confirmed these findings.
CONCLUSIONS
RA patients receiving CM face difficulties in following guideline-recommended GC discontinuation protocols. IM can promote GC discontinuation and is a promising strategy to reduce GC dependency in RA management. (Trial registration: ClinicalTrials.gov, No. NCT05219214).
Adult
;
Aged
;
Female
;
Humans
;
Male
;
Middle Aged
;
Arthritis, Rheumatoid/drug therapy*
;
Glucocorticoids/therapeutic use*
;
Medicine, Chinese Traditional
;
Retrospective Studies
5.Efficacy and Safety of Systemic Thrombolysis in the Treatment of Lower Extremity Fracture Complicated With Distal Deep Vein Thrombosis.
Shi-Qiang LIAO ; Shu-Ming SHI ; Qiang ZHANG ; Chuan-Yong LI ; Guang-Feng ZHENG ; Zhi-Chang PAN ; Jian-Jie RONG
Acta Academiae Medicinae Sinicae 2025;47(2):237-243
Objective To evaluate the efficacy and safety of systemic thrombolysis(ST)and standard anticoagulation(SA)in the treatment of lower extremity fracture complicated with distal deep vein thrombosis(DDVT).Methods We retrospectively analyzed the clinical data of 60 patients with lower extremity fracture complicated with DDVT treated from January 2021 to December 2023.When the lower limb venography indicated a calf thrombus burden score ≥3 points,a retrievable inferior vena cava filter(IVCF)was successfully placed in the healthy femoral vein before orthopedic surgery.The patients who received further anticoagulant or thrombolytic therapy after surgery were allocated into a ST group(n=30,urokinase ST and SA)and a SA group(n=30,only SA).The two groups were compared in terms of calf thrombus burden score,thrombus dissolution rate,IVCF placement time,IVCF retrieval rate,intercepted thrombi,hemoglobin level,platelet count,D-dimer level,and complications.Results There was no statistically significant difference in the calf thrombus burden score between the two groups before treatment(P=0.431).However,after treatment,the scores in both groups decreased(both P<0.001),with the ST group showing lower score than the SA group(P=0.002).The thrombus dissolution rate in the ST group was higher than that in the SA group(P<0.001).There was no statistically significant difference in the IVCF placement time between the two groups(P=0.359),and the IVCF retrieval rate was 100% in both groups.The ST group had fewer intercepted thrombi than the SA group(P=0.002).There was no statistically significant difference in hemoglobin level(P=0.238),platelet count(P=0.914),or D-dimer level(P=0.756)between the two groups before treatment.However,after treatment,both groups showed an increase in platelet count(both P<0.001)and a decrease in D-dimer level(both P<0.001).There was no statistically significant difference in the occurrence of complications between the two groups(P=0.704).Conclusions Both SA and ST demonstrate safety and efficacy in the treatment of lower extremity fractures complicated with DDVT,serving as valuable options for clinical application.Compared with SA,ST not only enhances the thrombus dissolution in the calf but also mitigates the risk of thrombosis associated with IVCF.
Humans
;
Venous Thrombosis/therapy*
;
Retrospective Studies
;
Thrombolytic Therapy/methods*
;
Male
;
Female
;
Middle Aged
;
Fractures, Bone/complications*
;
Lower Extremity/injuries*
;
Anticoagulants/therapeutic use*
;
Aged
;
Treatment Outcome
;
Adult
6.Optimisation of CUBIC tissue clearing technology based on perfusion methods
Chuan-Hui GONG ; Jia-Yi QIU ; Ke-Xin YIN ; Ji-Ru ZHANG ; Cheng HE ; Ye YUAN ; Guang-Ming LÜ
Acta Anatomica Sinica 2024;55(3):363-370
Objective In order to shorten the transparency time of clear,unobstructed brain imaging cocktails and computational analysis(CUBIC),improve the transparency efficiency,and explore the possibility of applying hydrophilic tissue transparency technique,this study was conducted to optimize the perfusion of CUBIC technique and compare it with four hydrophilic tissue clearing method in terms of tissue transparency effect,transparency time,area change,volume change and adeno-associated virus(AAV)fluorescence retention.Methods Brain,liver,spleen and kidney of 6 adult Institute of Cancer Research(ICR)mice were subjected to clearing treatment by SeeDB,FRUIT,ScaleS and CUBIC method,respectively.The area and gray value of the samples were measured by Image J 1.8.0,and the volume before and after transparency was measured by drainage method to compare the transparency effect,time and size deformation of each group.Perfusion optimization of the CUBIC was performed by improving the perfusion rate with the optimal perfusion dose,each group of the experimental sample size was 6.Fluorescence preservation by different techniques was evaluated by injecting AAV in the motor cortex of 16 adult mice and taking the cervical spinal segments for transparency treatment after four weeks,and the fluorescence photographs were measured by Image J 1.8.0 to measure the mean fluorescent intensity.Results The optimal perfusion rate and dose of CUBIC was 15 ml/min and 200 ml respectively.For transparency ability and speed,the perfusion CUBIC had the lowest mean gray value and took the shortest time,while CUBIC consumed the longest time,and SeeDB,FRUIT,and ScaleS did not show good transparency ability.In terms of area and volume changes,several techniques showed different degrees of expansion after transparency of tissues or organs.In terms of fluorescence retention,perfusion CUBIC showed the best retention of green fluorescent protein(GFP)fluorescence signal,followed by CUBIC,ScaleS,FRUIT,and SeeDB.Conclusion Perfusion CUBIC technique shows the best tissue transparency,the shortest transparency time,and the most AAV fluorescence retention compared with other techniques.
7.Maintenance and improvement program for WYD2000 field surgical lamp
Ming-Ming ZHU ; Ji-Su CAO ; Ze-Rui ZHANG ; Jiang-Hui HAO ; Rui-Zhe WANG ; Feng ZHOU ; Lu-Chuan XUN
Chinese Medical Equipment Journal 2024;45(4):116-118
The steps for installation and withdrawal of WYD2000 field surgical lamp were introduced.The failures and causes of broken cross-arm connector of WYD2000 field surgical lamp were analyzed.The problems of WYD2000 field surgical lamp in vulnerability to breaking and difficulty in maintenance were solved by designing and manufacturing a special maintenance tool and optimizing the materials and fixing mode of cross-arm connection.References were provided for main-tenance and improvement of WYD2000 field surgical lamp.[Chinese Medical Equipment Journal,2024,45(4):116-118]
8.Development and Application of a Micro-device for Rapid Detection of Ammonia Nitrogen in Environmental Water
Peng WANG ; Yong TIAN ; Chuan-Yu LIU ; Wei-Liang WANG ; Xu-Wei CHEN ; Yan-Feng ZHANG ; Ming-Li CHEN ; Jian-Hua WANG
Chinese Journal of Analytical Chemistry 2024;52(2):178-186,中插1-中插3
The analysis of ammonia nitrogen in real water samples is challenging due to matrix interferences and difficulties for rapid on-site analysis.On the basis of the standard method,i.e.water quality-determination of ammonia nitrogen-salicylic acid spectrophotometry(HJ 536-2009),a simple device for online detecting ammonia nitrogen was developed using a sequential injection analysis(SIA)system in this work.The ammonia nitrogen transformation system,color reaction system,and detection system were built in compatible with the SIA system,respectively.In particular,the detection system was assembled by employing light-emitting diode as the light source,photodiode as the detector,and polyvinylchloride tube as the cuvette,thus significantly reducing the volume,energy consumption and fabricating cost of the detection system.As a result,the accurate analysis of ammonia nitrogen in complex water samples was achieved.A quantitative detection of ammonia nitrogen in water sample was obtained in 12 min,along with linear range extending to 1000 μmol/L,precisions(Relative standard deviation,RSD)of 4.3%(C=10 μmol/L,n=7)and 4.2%(C=500 μmol/L,n=7),and limit of detection(LOD)of 0.65 μmol/L(S/N=3,n=7).The results of interfering experiments showed that the detection of ammonia nitrogen by the developed device was not interfered by the common coexisting ions and components,therefore the environmental water could be directly analyzed,such as reservoir water,domestic sewage,sea water and leachate of waste landfill.The analytical results were consistent with those obtained by the environmental protection standard method(Water quality determination of ammonia nitrogen-salicylic acid spectrophotometry,HJ 536-2009).In addition,the spiking recoveries were in the range of 92.3%-98.1%,further confirming the accuracy and practicality of the developed device.
9.Key issues in the study of drug nanocrystals self-stabilized Pickering emulsions as drug delivery system
Ji-fen ZHANG ; Fang-ming DONG ; Chuan LIU ; Tao YI
Acta Pharmaceutica Sinica 2024;59(6):1582-1592
Drug nanocrystals self-stabilized Pickering emulsion (DNSPE) is a novel Pickering emulsion with drug nanocrystals as the stabilizer. There are more and more researches on DNSPE in the field of drug delivery in recent years. On the basis of summarizing the research status of DNSPE used as drug delivery systems, this paper comprehensively reviewed the research progress of three key issues, such as the main factors affecting construction of DNSPE, characterization methods of properties and structures, and
10.Clinical evaluation of platelet-rich plasma in the treatment of early and middle stage knee osteoarthritis under 3.0T MRI T2 mapping sequence.
Zhao Yang WANG ; Wen Fei GAO ; Yi Ming SHAO ; Yi Chuan GAO ; Xue Shan XU ; Bing Jie LIU ; Ming Sheng ZHANG
Chinese Journal of Surgery 2023;61(2):138-144
Objective: To quantitatively evaluate the clinical effect of platelet-rich plasma(PRP) intra-articular injection for early and middle stage knee osteoarthritis(KOA) treatment by 3.0T MRI T2 mapping sequence. Methods: Clinical data of 26 patients with early or middle stage KOA who received treatment from April to December 2021 at Department of Orthopaedic Surgery,the Second Affiliated Hospital,Zhengzhou University were retrospectively analyzed. In total, 8 patients were male and 18 were female,with age of (66.4±12.0)years(range:51 to 94 years). Four patients were bilateral KOA and 22 patients were unilateral KOA.All patients received PRP intra-articular injection. Patients underwent 3.0T MRI T2 mapping sequence scanning pre-treatment,3-month-after and 6-month-after treatment respectively. Those were used to measure and compare T2 values of medial and lateral femoral articular surface and patellofemoral articular surface. Visual analogue scale(VAS) and Western Ontario and McMaster Osteoarthritis Index (WOMAC) score were recorded and evaluated. The results were analyzed using repeated measure ANOVA followed by Bonferroni multiple comparison test.The correlation between WOMAC scores and T2 values at pre-treatment and 6 months post-treatment was analyzed using Pearson correlation test. Results: After treatment, the patients' International Cartilage Regeneration&Joint Preservation Society(ICRS) classification were partly improved(one case improved from grade Ⅲ to grade Ⅱ, one case improved from grade Ⅱ to grade Ⅰ),and all patients generally improved after treatment in clinical symptoms. Compared with pre-treatment,VAS and WOMAC scores of grade Ⅰ,Ⅱ,and Ⅲ of 6-month after treatment were declined significantly(all P<0.05).The T2 values of articular cartilage declined to varying degrees(the decrease in T2 values was about 2.06 ms in grade Ⅰ, 2.66 ms in grade Ⅱ, and 3.72 ms in grade Ⅲ).Three-month (VAS:4.8±1.3,WOMAC:21.5±4.0) and 6-month (VAS:4.2±1.4,WOMAC:17.2±2.9) after treatment, the VAS and WOMAC score were significantly higher than those before treatment (VAS:6.0±1.2, WOMAC:29.0±2.3) (F=48.846, F=346.746;both P<0.01). Multiple comparisons showed a statistically significant difference between pre-treatment and post-treatment VAS (P<0.01) and it also was significantly different between 3-month and 6-month post-treatment (P<0.01).At 3- and 6-month after treatment,WOMAC scores were significantly different from before treatment.And it also was significantly different between 3-month and 6-month post-treatment (P<0.01).There was a statistically significant improvement in T2 values of patellofemoral articular surface, medial and lateral femoral articular surface at pre-treatment((44.64±4.02)ms,(44.17±3.64)ms and(43.53±3.91)ms) and 3-month ((43.19±3.91)ms,(43.24±3.34)ms and (42.47±3.80)ms), 6-month ((41.49±3.64)ms,(41.83±3.15)ms and (41.10±3.42)ms) after treatment(F=148.845,F=73.657,F=86.268;all P<0.01).The results of the multiple comparisons showed a statistically significant difference in the T2 values of medial and lateral femoral articular surface and patellofemoral articular surface at each time point(all P<0.01).The Pearson correlation analysis suggested that the WOMAC score at pre-treatment was positively correlated with the medial condyle (r=0.856,P<0.01) and the patellofemoral joint surface T2 values (r=0.840,P<0.01);The WOMAC score at 6-month post-treatment was positively correlated with the medial condyle (r=0.731,P<0.01) and the patellofemoral joint surface T2 values (r=0.691,P<0.01). Conclusions: In the treatment of early and mid-stage KOA,MRI T2 mapping sequences are able to indicate the integrity of cartilage morphology and quantitatively evaluate cartilage repair. PRP has a good therapeutic effect on cartilage repair and reconstruction.
Humans
;
Female
;
Male
;
Osteoarthritis, Knee/therapy*
;
Retrospective Studies
;
Orthopedic Procedures
;
Platelet-Rich Plasma
;
Magnetic Resonance Imaging

Result Analysis
Print
Save
E-mail