1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Mechanism of action of Qingjie Huagong decoction reducing inflammatory response of acute pancreatitis based on PI3K/AKT/NF-κB signaling pathway
Xiao-dong ZHU ; Min-chao FENG ; Kun-rong LIU ; Ying BAN ; Pan SU ; Chuan-feng XUAN ; Xiao-yi HUANG ; De-wen LI ; Xi-ping TANG ; Guo-zhong CHEN
Chinese Pharmacological Bulletin 2025;41(5):978-984
Aim To explore the therapeutic effect and mechanism of Qingjie Huagong decoction in modulating PI3K/AKT/NF-κB signaling pathway in inflammatory response of acute pancreatitis(AP)mice.Methods Twenty-four mice were randomly divided into Blank group,Model group,Ustekin group,and Qingjie Hua-gong decoction group,with six mice in each group.The AP model was prepared by using rain frogin.Serum α-AMS,PNLP,IL-1β,IL-6,IL-8,IL-18,and TNF-α lev-els were detected by ELISA;the pancreatic pathology was detected by HE staining;the expressions of PI3K,AKT,and NF-κB-related proteins and mRNAs were de-tected by immunohistochemistry,Western blot,and RT-qPCR.Results Compared with the blank group,the model group showed obvious pathological damage to the pancreas,with significantly higher serum α-AMS,PN-LP,IL-1β,IL-6,IL-8,IL-18,and TNF-α levels(P<0.01),and significantly higher levels of PI3K,AKT,and NF-κB-related proteins and mRNA expression(P<0.01).Compared with the model group,both the Qingjie Huagong decoction group and the ustekin group improved the histopathological changes in the pancreas of AP mice,decreased the serum α-AMS,PNLP,IL-1β,IL-6,IL-8,IL-18,and TNF-α levels,and down-reg-ulated the expression levels of pancreatic PI3K,AKT,NF-κB-related proteins and mRNA(P<0.05 or P<0.01).Conclusion Qingjie Huagong decoction may inhibit the inflammatory response and protect pancreat-ic tissues by regulating the expression of PI3K/AKT/NF-κB signaling pathway.
3.Incidence rates and high-risk factors of different typies of patient-ventilator asynchrony under assisted mechanical ventilation
Qimin CHEN ; Jiaoyangzi LIU ; Jia YUAN ; Dehua HE ; Ming LIU ; Caixue PAN ; Ying LIU ; Yan TANG ; Xu LIU ; Xianjun CHEN ; Chuan XIAO ; Shuwen LI ; Wei LI ; Daixiu GAO ; Feng SHEN
The Journal of Practical Medicine 2025;41(10):1509-1516
Objective To investigate the incidence and types of patient-ventilator asynchrony(PVA)in mechanically ventilated patients within the intensive care unit(ICU),and to identify associated high-risk factors,thereby providing a basis for reducing PVA,enhancing mechanical ventilation efficiency,and refining ventilation strategies.Methods A prospective observational study was conducted among patients admitted to the general ICU of the Affiliated Hospital of Guizhou Medical University from October to December 2024 who were receiving mechanical ventilation.Inclusion criteria were as follows:age ≥18 years and mechanical ventilation duration ≥12 hours.Exclusion criteria included complete controlled mechanical ventilation,palliative care or do-not-resuscitate status,and lack of informed consent.Senior respiratory therapists performed daily bedside observations of ventilator waveforms for 10~15 minutes between 08:00 and 12:00.PVA was diagnosed based on pressure-time and flow-time waveforms,with the types of PVA being recorded.Demographic and clinical data,including age,sex,body mass index(BMI),primary diagnosis,comorbidities,APACHEⅡ score at ICU admission,blood gas analysis,ventila-tion mode and parameters,analgesia and sedation status,duration of mechanical ventilation,and length of ICU stay,were collected.The incidence and types of PVA during the observation period were analyzed.Univariate and multivariate logistic regression analyses were performed to identify high-risk factors for PVA.Clinical outcomes were compared between patients with and without PVA.Results A total of 105 patients and 453 episodes of assisted mechanical ventilation waveforms were analyzed.Among these,60.95%(64/105)experienced at least one episode of PVA.Of the 453 ventilation waveforms assessed,35.76%(162/453)demonstrated PVA.The types of PVA,ranked by incidence,were as follows:cycling mismatch(12.58%,57/453),double triggering(11.92%,54/453),ineffective triggering(9.49%,43/453),flow starvation(5.30%,24/453),and exhalation flow limitation(1.77%,8/453).The incidence of PVA varied significantly across different ventilation modes:45.7%in volume-assist/control ventilation(V-A/C),38.1%in pressure-assist/control ventilation(P-A/C),42.9%in synchronized intermittent mandatory ventilation(SIMV),and 16.7%in pressure support ventilation(PSV)(P<0.001).Multi-variate logistic regression analysis revealed that the mechanical ventilation mode[reference:PSV;V-A/C:OR=4.687,95%CI:2.140~10.263,P<0.001;P-A/C:OR=2.922,95%CI:1.489~5.734,P=0.002;SIMV:OR=4.682,95%CI:1.758~12.466,P=0.002]and actual respiratory rate(OR=1.07,95%CI:1.016~1.127,P=0.011)were significant high-risk factors for PVA.Patients with PVA had a significantly longer duration of mechanical ventilation[8.21(5.35,13.91)days vs.3.00(1.96,5.71)days,P<0.001]compared to those without PVA.Conclusions PVA is commonly observed in ICU patients receiving assisted invasive mechanical ventilation,with cycling mismatch,double triggering,and ineffective triggering being the most prevalent types.The incidence of PVA tends to be lower when using the PSV mode.Clinically,real-time monitoring of patient-ventilator synchrony via ventilator waveforms,along with the optimization of ventilator modes and parameters,should be employed to minimize the occurrence of PVA and enhance the efficiency of mechanical ventilation.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Sequential treatment with siltuximab and tocilizumab for childhood idiopathic multicentric Castleman disease: a case report.
Ping YI ; Xing-Xing ZHANG ; Tian TANG ; Ying WANG ; Xiao-Chuan WU ; Xing-Fang LI
Chinese Journal of Contemporary Pediatrics 2025;27(5):613-617
The patient, an 11-year-old girl, was admitted with recurrent fever for 20 days, worsening with abdominal distension for 7 days. Upon admission, she presented with recurrent fever, lymphadenopathy, hepatosplenomegaly, polyserositis, and multiple organ dysfunction. Lymph node pathology and clinical manifestations confirmed the diagnosis of idiopathic multicentric Castleman disease-TAFRO syndrome. Treatment with siltuximab combined with glucocorticoids was initiated, followed by maintenance therapy with tocilizumab. The patient is currently in complete clinical remission. Therefore, once a child is diagnosed with idiopathic multicentric Castleman disease -TAFRO syndrome, early use of siltuximab should be considered for rapid disease control, followed by tocilizumab for maintenance therapy.
Humans
;
Castleman Disease/drug therapy*
;
Child
;
Antibodies, Monoclonal, Humanized/administration & dosage*
;
Female
;
Antibodies, Monoclonal/administration & dosage*
7.Glucocorticoid Discontinuation in Patients with Rheumatoid Arthritis under Background of Chinese Medicine: Challenges and Potentials Coexist.
Chuan-Hui YAO ; Chi ZHANG ; Meng-Ge SONG ; Cong-Min XIA ; Tian CHANG ; Xie-Li MA ; Wei-Xiang LIU ; Zi-Xia LIU ; Jia-Meng LIU ; Xiao-Po TANG ; Ying LIU ; Jian LIU ; Jiang-Yun PENG ; Dong-Yi HE ; Qing-Chun HUANG ; Ming-Li GAO ; Jian-Ping YU ; Wei LIU ; Jian-Yong ZHANG ; Yue-Lan ZHU ; Xiu-Juan HOU ; Hai-Dong WANG ; Yong-Fei FANG ; Yue WANG ; Yin SU ; Xin-Ping TIAN ; Ai-Ping LYU ; Xun GONG ; Quan JIANG
Chinese journal of integrative medicine 2025;31(7):581-589
OBJECTIVE:
To evaluate the dynamic changes of glucocorticoid (GC) dose and the feasibility of GC discontinuation in rheumatoid arthritis (RA) patients under the background of Chinese medicine (CM).
METHODS:
This multicenter retrospective cohort study included 1,196 RA patients enrolled in the China Rheumatoid Arthritis Registry of Patients with Chinese Medicine (CERTAIN) from September 1, 2019 to December 4, 2023, who initiated GC therapy. Participants were divided into the Western medicine (WM) and integrative medicine (IM, combination of CM and WM) groups based on medication regimen. Follow-up was performed at least every 3 months to assess dynamic changes in GC dose. Changes in GC dose were analyzed by generalized estimator equation, the probability of GC discontinuation was assessed using Kaplan-Meier curve, and predictors of GC discontinuation were analyzed by Cox regression. Patients with <12 months of follow-up were excluded for the sensitivity analysis.
RESULTS:
Among 1,196 patients (85.4% female; median age 56.4 years), 880 (73.6%) received IM. Over a median 12-month follow-up, 34.3% (410 cases) discontinued GC, with significantly higher rates in the IM group (40.8% vs. 16.1% in WM; P<0.05). GC dose declined progressively, with IM patients demonstrating faster reductions (median 3.75 mg vs. 5.00 mg in WM at 12 months; P<0.05). Multivariate Cox analysis identified age <60 years [P<0.001, hazard ratios (HR)=2.142, 95% confidence interval (CI): 1.523-3.012], IM therapy (P=0.001, HR=2.175, 95% CI: 1.369-3.456), baseline GC dose ⩽7.5 mg (P=0.003, HR=1.637, 95% CI: 1.177-2.275), and absence of non-steroidal anti-inflammatory drugs use (P=0.001, HR=2.546, 95% CI: 1.432-4.527) as significant predictors of GC discontinuation. Sensitivity analysis (545 cases) confirmed these findings.
CONCLUSIONS
RA patients receiving CM face difficulties in following guideline-recommended GC discontinuation protocols. IM can promote GC discontinuation and is a promising strategy to reduce GC dependency in RA management. (Trial registration: ClinicalTrials.gov, No. NCT05219214).
Adult
;
Aged
;
Female
;
Humans
;
Male
;
Middle Aged
;
Arthritis, Rheumatoid/drug therapy*
;
Glucocorticoids/therapeutic use*
;
Medicine, Chinese Traditional
;
Retrospective Studies
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Study on Colorimetric Sensor Array Based on Enzymatic Method for Highly Selective Detection of Sarin
Lian-Bo JIANG ; Guo-Hong LIU ; Zhuang-Hu XU ; Jian LI ; Yong-Ling SHEN ; Cai-Xia XU ; Chuan-Qin ZANG ; Yan-Hua XIAO ; Dan-Ping LI ; Ting LIANG
Chinese Journal of Analytical Chemistry 2025;53(5):832-841,中插21-中插23
Sarin(GB)is a typical representative of nerve agents with high toxicity,and very low amount can cause death.GB can cause water and atmospheric environment poisoning,so the detection of GB in water and air is of great significance.In this work,a colorimetric sensor array(CSA)based on GB inhibition of cholinesterase activity was constructed to detect GB with high selectivity.A 4×4 colorimetric array was constructed using acetylcholinesterase(AChE),butyryl cholinesterase(BuChE)and the corresponding substrate acetylthiocholine iodide(S-ACh),butyryl thiocholine iodide(S-BCh),acetylcholine chloride(ACh),butyryl choline chloride(BCh)and 2,6-dichloroindophenol ethyl ester(DCIE).The linear curve of the sensor was Y=131.3×lgC+271.6(R2=0.997),where Y was the array response Euclidean distance,C was the concentration of GB(mg/L),the linear range was 0.03?0.32 mg/L,and the detection limit was 27.6 μg/L.The method could effectively distinguish chemical warfare agents(CWA)such as VX,Soman(GD),mustard gas(HD),Louie reagent(L),and had high anti-interference ability,sensitivity and good repeatability.It was successfully applied to the detection of GB in simulated water and simulated air samples,and the sample recovery rate was 97.2% ?100.9%.This method would be potentially applied to the field rapid detection of nerve agents.
10.Highly Sensitive Detection of Water in Organic Solvents Using Pyrene-Phenol-based Fluorescent Probe
Jing LIANG ; Yan-Li WANG ; Cui-Wen JIANG ; Xiao-Chuan HUANG ; Li TANG ; Tao LI ; Yu YA ; De-Jiao NING ; Li-Ping XIE ; Fei-Yan YAN
Chinese Journal of Analytical Chemistry 2025;53(6):894-902,中插1-中插5
A pyrene-phenol-based fluorescent probe PyP which showed typical intramolecular charge transfer(ICT)and monomer-excimer activities was synthesized by using pyrene carboxaldehyde hydrazone and 4-tert-butyl-2,6-diformylphenol as the raw materials.The effects of solvents on PyP were studied,and the results showed that the color of protic polar solvents(Ethanol,N,N-dimethylformamide,methanol and H2O)were successfully identified.Based on the solvent polarity-regulated PyP monomer-excimer switching,the rapid and highly sensitive ratiometric probe,"Turn-off"and"Turn-on"multimodal probes were established for detection of trace water content in organic solvents(Dimethyl sulfoxide,N,N-dimethylformamide,ethanol and methanol),with detection limits(3σ/k)of 0.0021%,0.046%,0.062%and 0.024%.The method was successfully used to detect water content in dimethyl sulfoxide,N,N-dimethy lformamide,ethanol and methanol commercial organic solvents,with recoveries ranging from 97.2%to 108.0%.The developed method showed good accuracy and stability,and had good application prospect.

Result Analysis
Print
Save
E-mail