1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Construction and application of a large capacity VNAR library from the whitespotted bamboo shark (Chiloscyllium playgiosum).
Hao LI ; Litong LIU ; Xinyi KANG ; Chuan-Wei CHEN ; Mengran WANG ; Shaoqin FU ; Qingtong ZHOU ; Bo ZHAO ; Dehua YANG ; Ming-Wei WANG
Acta Pharmaceutica Sinica B 2025;15(4):1912-1921
Fifty whitespotted bamboo sharks (Chiloscyllium playgiosum) of both sexes were used to establish a large capacity variable domain of the new antigen receptor (VNAR) library with a total capacity of over 109 colony-forming units (CFU). It was applied to screen VNARs against human serum albumin (HSA) and human transcription factor EB (TFEB), respectively. Meanwhile, VNAR libraries specific to HSA and TFEB with capacities above 108 CFU were obtained following conventional immunization. These two approaches were systematically studied in terms of VNAR yield and composition. By comparing the VNAR sequences obtained from naïve and antigen-immunized libraries, we found that the complementary-determining region 3 (CDR3) of the former differs in composition from that of the latter. It shares a higher degree of homology with the naïve library. Meanwhile, the binding efficiency assessed by ELISA is also different between the naïve and antigen-immunized libraries. The binding of VNARs from the TFEB-immunized library appeared to surpass that observed with the naïve libraries, whereas the performance of VNARs from the HSA-immunized library indicated that both the immunized and naïve libraries for HSA had positive binding responses in polyclonal and monoclonal ELISA. The results are useful to develop novel diagnostic and therapeutic products based on shark VNARs.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Efficacy and safety of a facilitated percutaneous coronary intervention with half-dose recombinant staphylokinase in ST-segment elevation myocardial infarction
Tian-yu WU ; Wen-hao ZHANG ; Peng-sheng CHEN ; Chen LI ; Tian WU ; Zhan LÜ ; Tong WANG ; Kun LIU ; Zhi-wen TAO ; Xiao-xuan GONG ; Liang YUAN ; Yong LI ; Bo CHEN ; Xin CHEN ; Zeng-guang CHEN ; Nai-quan YANG ; Yuan-yuan SANG ; Xiao-yan WANG ; Bai-hong LI ; Li ZHU ; Guo-yu WANG ; Xin ZHAO ; Chuan LU ; Jun JIANG ; Rui-na HAO ; Chun-jian LI
Chinese Journal of Interventional Cardiology 2025;33(8):431-438
Objective To investigate the clinical efficacy and safety of facilitated percutaneous coronary intervention(PCI)with half-dose recombinant staphylokinase(r-SAK)in patients with ST-segment elevation myocardial infarction(STEMI)who are expected to undergo PCI within 120 minutes.Methods From October 2021 to August 2022,a total of 200 STEMI patients in eight centers were included and randomly assigned in a 1﹕1 ratio to either r-SAK group or control group.Patients received loading doses of aspirin and ticagrelor and intravenous heparin and were randomized to receive an intravenous bolus of either 5 mg r-SAK or normal saline prior to PCI.The outcomes were set as ST-segment resolution(STR)at 60-90 minutes after PCI,the proportion and transition of pathological Q waves on the 5th day after PCI,and the proportion of high-sensitivity cardiac troponin T(hs-cTnT)peaking within 12 hours of onset.The safety outcome was major bleeding events defined as Bleeding Academic Research Consortium(BARC)≥type 3 bleeding during hospitalization.Results Compared with the control group,the r-SAK group had a higher proportion of STR≥70%within 60-90 minutes after PCI(58.3%vs.40.3%,P=0.009);a lower proportion of pathological Q waves(59.1%vs.74.1%,P=0.040);a lower rate of Q wave progression(14.8%vs.43.2%,P<0.001);a higher rate of Q wave disappearance(12.5%vs.3.7%,P=0.027);and a higher proportion of hs-cTnT peaking within 12 hours of symptom onset[31/40(77.5%)vs.17/33(51.5%),P=0.027].Regarding the safety outcome,no significant difference in BARC≥type 3 bleeding was found between the two groups during hospitalization(P>0.05).Conclusions For STEMI patients who were expected to undergo primary PCI within 120 minutes of symptom onset,the facilitated PCI with half-dose r-SAK significantly increased the proportion of STR≥70%at 60-90 minutes after PCI,reduced the formation of pathological Q waves,and shortened the time to peak hs-cTnT,without increasing the risk of bleeding,which should be an alternative reperfusion strategy worthy of further study.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Construction and Performance of CD44-targeted Teniposide Nano-delivery System for Anti-B-cell Lymphoma Activity in vitro
Chuan-Min ZHANG ; Si-Jing MEI ; Lei HAN ; Yuan-Wei SHI ; Bo-Lian XIAO ; Xiao-Li XIE ; Quan-Ping SU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):815-825
Although teniposide(VM26)is widely used in the treatment of lymphoma,its poor water sol-ubility,low bioavailability and systemic toxicities still limit its clinical application.Nano-delivery systems are effective in increasing the bioavailability and reducing the toxicity of VM26,but there is an urgent need to overcome the problem of its non-specific targeting.Therefore,in this paper,we designed and constructed a hyaluronic acid-modified teniposide-targeted nano-delivery system(VM26-TNDS),and characterised its drug encapsulation rate,particle size and zeta potential.We also investigated the effects of VM26-TNDS on B-cell lymphoma cells with different expression of CD44 receptor,in terms of cellular targeting,inhibitory effect of proliferation,and induction of apoptosis and necrosis.The results showed that the drug encapsulation efficiency of VM26-TNDS exceeded 85%,and its liquid formulation could be stably stored at 4 ℃ for more than 6 months without precipitation.Based on CD44 receptor expression,Granta-519(high expression),Raji(medium-low expression)and SU-DHL-4(almost no expression)were screened for cellular experiments.Compared with VM26-NDS,the targeted modification could effec-tively reduce the uptake of VM26-TNDS by RAW264.7 and increase the uptake of VM26-TNDS by CD44 receptor-expressing lymphoma cells.The inhibitory proliferative effect and apoptotic necrosis-inducing a-bility of VM26-TNDS were stronger than those of VM26-NDS for Granta-519 and Raji cells,whereas there was no significant difference in the inhibitory effect on proliferation and ability to induce apoptosis and necrosis between VM26-NDS and VM26-TNDS in SU-DHL-4 cells,reflecting the targeting advantage for VM26-TNDS,as expected.However,its toxic effect on B-cell lymphoma cells only reflected the targeting advantage at some concentrations(0.25 μmol/L and 0.5 μmol/L),which met the expectation.The a-bove results indicate that a teniposide-targeted nano-delivery system,VM26-TNDS,has been successfully prepared in this study.VM26-TNDS improves the delivery efficiency of VM26 by targeting human B-cell lymphoma cells expressing the CD44 receptor,thus killing human B-cell lymphoma cells more effectively and overcoming the problem of non-specific targeting in drug delivery to improve the therapeutic effect.Its biological therapeutic effects and mechanisms still need to be proved by more in vitro and in vivo ex-perimental evidence.
9.Multicolor Fluorescent Copper Nanoclusters/Starch Composites and Their Application in Fingermark Development
Chuan-Jun YUAN ; Ming LI ; Yi-Fei SUN ; Jia-Ming LYU ; Zhi-Bo GAO ; Shi-Qiang SUN ; Pei-Liang HAN ; Feng-He LIU
Chinese Journal of Analytical Chemistry 2025;53(1):55-64,中插1-中插3
On the basis of that the fluorescence wavelength of copper nanoclusters(CuNCs)could cover the entire visible region,multicolor fluorescent CuNCs/starch composites were prepared and applied in fingermark development.With L-glutathione as the reducing agent and protective ligand,blue emissive and orange emissive CuNCs solutions were obtained in alkaline solutions at 90℃and 25℃,respectively.With the aggregation-induced emission effect induced by ethanol as a poor solvent,the fluorescence of orange emissive CuNCs with a higher intensity was achieved in an ethanol-water solution.With ascorbic acid as the reducing agent and 3-mercaptopropionic acid as the protective agent,green emissive CuNCs solution was prepared in an acid solution.Particle morphologies,chemical compositions and optical properties of these three CuNCs above were investigated using physical characterization and spectroscopic analysis,indicating that well-dispersed CuNCs had excellent photoluminescent properties.These CuNCs solutions were combined with starch to form composite powders by simply drying.The influences of the type of CuNCs and the ratio of CuNCs to starch on the emission wavelength and fluorescence intensity of the products were studied.The obtained CuNCs/starch composites could emit blue,green and orange fluorescence under 365 nm ultraviolet light,respectively,which were suitable for fingermark development.Minutiae and partial level-3 features of latent fingermarks could be effectively developed.High-quality fluorescence fingermark images would be captured using appropriate optical filters to eliminate background interference of various substrates.
10.Study on Colorimetric Sensor Array Based on Enzymatic Method for Highly Selective Detection of Sarin
Lian-Bo JIANG ; Guo-Hong LIU ; Zhuang-Hu XU ; Jian LI ; Yong-Ling SHEN ; Cai-Xia XU ; Chuan-Qin ZANG ; Yan-Hua XIAO ; Dan-Ping LI ; Ting LIANG
Chinese Journal of Analytical Chemistry 2025;53(5):832-841,中插21-中插23
Sarin(GB)is a typical representative of nerve agents with high toxicity,and very low amount can cause death.GB can cause water and atmospheric environment poisoning,so the detection of GB in water and air is of great significance.In this work,a colorimetric sensor array(CSA)based on GB inhibition of cholinesterase activity was constructed to detect GB with high selectivity.A 4×4 colorimetric array was constructed using acetylcholinesterase(AChE),butyryl cholinesterase(BuChE)and the corresponding substrate acetylthiocholine iodide(S-ACh),butyryl thiocholine iodide(S-BCh),acetylcholine chloride(ACh),butyryl choline chloride(BCh)and 2,6-dichloroindophenol ethyl ester(DCIE).The linear curve of the sensor was Y=131.3×lgC+271.6(R2=0.997),where Y was the array response Euclidean distance,C was the concentration of GB(mg/L),the linear range was 0.03?0.32 mg/L,and the detection limit was 27.6 μg/L.The method could effectively distinguish chemical warfare agents(CWA)such as VX,Soman(GD),mustard gas(HD),Louie reagent(L),and had high anti-interference ability,sensitivity and good repeatability.It was successfully applied to the detection of GB in simulated water and simulated air samples,and the sample recovery rate was 97.2% ?100.9%.This method would be potentially applied to the field rapid detection of nerve agents.

Result Analysis
Print
Save
E-mail