1.Efficacy of revision surgery for hiatal hernia with gastroesophageal reflux disease after sleeve gastrectomy
Chongwen ZHAN ; Lili LIU ; Qiwei SHEN ; Bo XU ; Xiaojian FU ; Yikai SHAO ; Rong HUA ; Qiyuan YAO
Chinese Journal of General Surgery 2025;34(4):668-675
Background and Aims:Gastroesophageal reflux disease(GERD)is a common complication following sleeve gastrectomy(SG),particularly in patients with concomitant hiatal hernia,where symptoms tend to be more persistent and refractory,significantly impairing postoperative quality of life.This study aimed to evaluate the efficacy of laparoscopic hiatal hernia repair combined with gastroesophageal fixation in SG patients with severe GERD and hiatal hernia,providing clinical reference for revisional surgical strategies.Methods:The clinical data of 9 patients with severe GERD after SG who underwent laparoscopic hiatal hernia repair and gastroesophageal fixation at Huashan Hospital,Fudan University,between January 2023 and June 2024 were retrospectively analyzed.GerdQ scores,proportion of endoscopically confirmed reflux esophagitis,and proton pump inhibitor(PPI)usage were compared before and after surgery.Surgical parameters and follow-up outcomes were also recorded.Results:All patients successfully completed the surgery without major intraoperative complications,and the mean postoperative hospital stay was 5.22 d.After a mean follow-up period of 15.27 months,the GerdQ score significantly decreased from 11.67±2.00 to 7.22±1.48.The proportion of patients with GerdQ score≥8 decreased from 100.00%to 44.44%,and the rate of endoscopically confirmed GERD dropped from 88.89%to 11.11%;PPI use also significantly declined,with all differences reaching statistical significance(all P<0.05).Conclusion:Laparoscopic hiatal hernia repair combined with gastroesophageal fixation can effectively alleviate reflux symptoms in SG patients with coexisting hiatal hernia,demonstrating favorable short-term efficacy and high safety.This approach may be a preferable surgical option for selected patients.
2.Efficacy of revision surgery for hiatal hernia with gastroesophageal reflux disease after sleeve gastrectomy
Chongwen ZHAN ; Lili LIU ; Qiwei SHEN ; Bo XU ; Xiaojian FU ; Yikai SHAO ; Rong HUA ; Qiyuan YAO
Chinese Journal of General Surgery 2025;34(4):668-675
Background and Aims:Gastroesophageal reflux disease(GERD)is a common complication following sleeve gastrectomy(SG),particularly in patients with concomitant hiatal hernia,where symptoms tend to be more persistent and refractory,significantly impairing postoperative quality of life.This study aimed to evaluate the efficacy of laparoscopic hiatal hernia repair combined with gastroesophageal fixation in SG patients with severe GERD and hiatal hernia,providing clinical reference for revisional surgical strategies.Methods:The clinical data of 9 patients with severe GERD after SG who underwent laparoscopic hiatal hernia repair and gastroesophageal fixation at Huashan Hospital,Fudan University,between January 2023 and June 2024 were retrospectively analyzed.GerdQ scores,proportion of endoscopically confirmed reflux esophagitis,and proton pump inhibitor(PPI)usage were compared before and after surgery.Surgical parameters and follow-up outcomes were also recorded.Results:All patients successfully completed the surgery without major intraoperative complications,and the mean postoperative hospital stay was 5.22 d.After a mean follow-up period of 15.27 months,the GerdQ score significantly decreased from 11.67±2.00 to 7.22±1.48.The proportion of patients with GerdQ score≥8 decreased from 100.00%to 44.44%,and the rate of endoscopically confirmed GERD dropped from 88.89%to 11.11%;PPI use also significantly declined,with all differences reaching statistical significance(all P<0.05).Conclusion:Laparoscopic hiatal hernia repair combined with gastroesophageal fixation can effectively alleviate reflux symptoms in SG patients with coexisting hiatal hernia,demonstrating favorable short-term efficacy and high safety.This approach may be a preferable surgical option for selected patients.
3.Short-term efficacy evaluation of single-session microwave ablation for benign thyroid nodules
Junsong LIU ; Chongwen XU ; Xiaobao YAO ; Ruimin ZHAO ; Shiyang WANG ; Qian ZHAO ; Honghui LI ; Yanxia BAI ; Shaoqiang ZHANG
Chinese Archives of Otolaryngology-Head and Neck Surgery 2024;31(7):414-420
OBJECTIVE To evaluate the short-term efficacy of single-session microwave ablation for benign thyroid nodule.METHODS Patients with benign thyroid nodules treated by microwave ablation between June 2019 and December 2022 at the Department of Otolaryngology Head and Neck Surgery,the First Affiliated Hospital of Xi'an Jiaotong University,were included for analysis.Thyroid function was tested 1 month after treatment,and ultrasound and thyroid function were performed 3 months,6 months and 1 year after treatment.Volume reduction rates(VRR)of nodules were calculated.Data of the last follow-up within 1 year were included for analysis.Variables including gender,age,whether Hashimoto's thyroiditis was present,longitudinal diameter of nodules,solid volume of nodules were included for univariate and multivariate analysis.RESULTS A total of 151 patients with 163 nodules were included.The perioperative complication rate was 1.99%(3/151).The VRR at half year after treatment was(79.58±17.70)%,and the success rate at half year after treatment was 93.43%(128/137).The VRR of at 1year after treatment was(81.24±24.29)%.The 1-year treatment success rate was 92.77%(77/83).Univariate and multivariate analysis showed that nodular solid volume and age were independent factors affecting VRR after ablation.Regression coefficient of age and solid volume was 0.34(P<0.05)and-0.47(P<0.05),respectively.For every 1 cm3 increase in solid volume,1-year VRR(%)decreased by 0.47.Regression equation:1-year VRR=68.92+0.34×age-0.47×solid volume.Serum FT4 gradually decreased and the thyroid stimulating hormone(TSH)gradually increased within 6 months after ablation,and the differences were statistically significant(P<0.05).After 6 months,serum FT4 gradually recovered to the normal level and TSH gradually recovered.However,TSH still did not reach the preoperative level one year after ablation.FT3 decreased gradually after treatment,but there was no significant difference between the values at each time point(P=0.40).After the ablation of thyroid nodule,the mean value of thyroid function index fluctuated,but all of them were within the normal reference range.CONCLUSION Microwave ablation is a safe and effective treatment method for benign thyroid nodules,with an overall success rate of over 90%.Solid nodule volume and age are independent factors affecting the microwave ablation effect of benign thyroid nodules.
4.Efficacy of magnetic traction hyoid suspension surgery in the animal model of OSAHS
Chongwen XU ; Fangli YANG ; Hao DAI ; Qian ZHAO ; Shaoqiang ZHANG ; Jinfeng YAN ; Yanxia BAI ; Jigang BAI
Journal of Xi'an Jiaotong University(Medical Sciences) 2023;44(3):460-465
【Objective】 To explore the effectiveness of creating the obstructive sleep apnea hypopnea syndrome (OSAHS) animal model of glossocoma using the botulinum toxin type A in white rabbits, and to explore the effectiveness and safety of magnetic traction hyoid suspension operation in the OSAHS animal model of glossocoma. 【Methods】 A total of 12 adult male experimental white rabbits were randomly divided into two groups. The animals in the experimental group were injected with 0.4 mL (10 U) of botulinum toxin type A in the genioglossus muscle to construct the OSAHS animal model of glossocoma. The animals in the control group were injected with 0.4 mL of normal saline. We designed and 3D printed a polyacrylate shell that could be loaded with inner and outer neodymium iron boron (NdFeB) magnets. After the modeling, a polyacrylate shell with the inner magnet device was fixed on the hyoid bone of the animals in the experimental group. All animals in the experimental group wore the polyacrylate orthotic neck brace containing the outer magnet 10 days after the operation. The arterial blood oxygen detector was used to record the oxygen saturation (SaO
5.Efficacy of three-port laparoscopic sleeve gastrectomy in treatment of obesity
Chongwen ZHAN ; Qiwei SHEN ; Yikai SHAO ; Bo XU ; Rong HUA ; Qiyuan YAO
Journal of Surgery Concepts & Practice 2023;28(5):463-468
Objective To evaluate the feasibility,safety and efficacy of three-port laparoscopic sleeve gastrectomy(LSG).Methods Clinical data of 130 patients with obesity who underwent LSG from April 2020 to January 2021 and completed follow-up in time were analyzed retrospectively.All patients were divided into two groups as surgical method,there were 52 cases in three-port group and 78 cases in four-port group.Perioperative indicators and improvement of obesity in two groups were compared.Results All procedures were performed via LSG.Compared with four-port group,the mean operative time of three-port group was shorter[(88.35±22.64)min vs.(98.29±26.25)min,P=0.027].There were no significant differences in amount of bleeding intraoperative,postoperative pain,postoperative drainage,hospital stay after operation,postoperative complication rate and weight loss 6 months and 2 years after surgery(P>0.05).Conclusions Under the premise of no increase in surgical complications and operative time,three-port LSG can reduce the number and size of surgical scars,which is conducive to skin beauty,and obtain the same weight loss effect as four-port LSG,and can be used as a routine operation for sleeve gastrectomy.
6.Quantitative evaluation of extracellular volume fraction after acute ST segment elevation myocardial infarction by iodine density based on spectral detector CT
Binghua CHEN ; Dongaolei AN ; Jie HE ; Rui WU ; Ruoyang SHI ; Chongwen WU ; Ting YUE ; Ziyang FAN ; Yisi DAI ; Jialu SHEN ; Yingying DING ; Ji WANG ; Jun PU ; Xingbiao CHEN ; Lianming WU ; Jianrong XU
Chinese Journal of Radiology 2020;54(6):527-533
Objective:To explore the feasibility of quantitative evaluation of extracellular volume (ECV) fraction in acute ST-segment elevation myocardial infarction (STEMI) by dual-layer spectral detector CT.Methods:The clinical and imaging data of 20 patients with STEMI who underwent cardiac contrast-enhanced CT and MRI from January to October 2019 in Renji Hospital affiliated to Shanghai Jiaotong University School of Medicine were retrospectively analyzed.The dual spectral detector was used in the enhanced CT scan of the coronary artery with retrospectively gate and the late iodine enhancement with prospective gate. Conventional image and holographic spectral image were obtained by iterative and spectral reconstruction. The short axis image of the heart matched with MR image was obtained by multiplanar reconstruction. Based on the data of spectral based image, the IDD map was reconstructed for the calculation of myocardial CT-ECV during the late iodine enhancement. ECV of infarcted myocardium, salvageable myocardium and remote myocardium based on CT and MRI were calculated respectively. Bland-Altman consistency test and intra group correlation coefficient analysis (ICC) were used to compare the consistency of two measurements and different methods. The correlation between CT-ECV and MRI-ECV was compared by Spearman method.Results:The CT-ECV values of infarcted, salvageable, and remote myocardium were 51.21 (49.27, 53)%, 38.64 (36.17, 40)%, and 51.21 (49.27, 53)%, respectively. The difference was statistically significant ( H= 43.17, P<0.01). The CT-ECV value of infarcted myocardium was significantly higher than that of salvageable myocardium and remote myocardium ( Z=-24.60, 35.40, P<0.01), but there was no significant difference between salvageable myocardium and remote myocardium ( Z= 10.80, P=0.15). The T 1 values of infarcted myocardium, salvageable myocardium and remote myocardium were (1 554.85±70.94), (1 443.85±67.28) and (1 307.05±91.73) ms respectively, the difference was statistically significant ( F=51.35, P<0.01). The T 1 value of infarcted myocardium was higher than that of salvageable myocardium and remote myocardium ( t=-5.07, 9.55, P<0.01), and salvageable myocardium was significantly higher than that of remote myocardium ( t=5.38, P<0.01). The MRI-ECV values of infarcted myocardium, salvageable myocardium and remote myocardium were 55.00 (49.27, 57.75)%, 33.50 (29.00, 35.00)%,and 27.00 (26.00, 29.00)%, respectively. The difference was statistically significant ( Z= 47.12, P<0.01). MRI-ECV of infarcted myocardium was significantly higher than that of salvageable myocardium and remote myocardium ( Z=37.45, -20.30, P< 0.01), and salvageable myocardium was significantly higher than that of remote myocardium ( Z = 17.15, P<0.05). The difference between CT-ECV and MRI-ECV measured by two physicians was good. The bias of Bland-Altman analysis was -0.1% (95% CI:-5.5%-5.2%), 0.8% (95% CI:-9.8%-8.2%), and the ICC values were 0.92 and 0.94, respectively. The bias of Bland-Altman analysis in CT-ECV and MRI-ECV consistency test was 4.00% (95% CI:-9.0%-16.9%) and ICC value was 0.88, which had a good correlation ( r=0.75, P=0.001). Conclusions:The iodine density based ECV fromdual-layer spectral detector CT can be used to quantitatively evaluate the changes of extracellular space after acute STEMI, which is helpful to quantitatively evaluate the histological changes after myocardial ischemia.
7.Diagnostic value of contrast-enhanced ultrasound combined with tumor markers in benign and malignant ovarian tumors
Yiyun XU ; Mang LI ; Yan CAI ; Yongjin PENG ; Yingying YUAN ; Wenfang WU ; Chongwen XIE
Journal of Chinese Physician 2019;21(8):1146-1148
Objective To explore the diagnostic value of contrast-enhanced ultrasound combined with tumor markers in benign and malignant ovarian tumors.Methods The clinical data of 100 patients with ovarian tumors treated in our hospital from May 2016 to May 2017 were analyzed retrospectively.The parameters of contrast-enhanced ultrasonography (CEUS) for benign and malignant ovarian tumors were analyzed.The levels of tumor markers were measured and the ultrasound imaging was analyzed.Analysis of the detection rate of benign and malignant ovarian tumors by contrast-enhanced ultrasound alone or in combination with tumor markers.Results Compared with benign ovarian tumors,ovarian malignant tumors have the characteristics of uneven enhancement,early onset and peak time of contrast enhancement,and higher rate of enhancement (P < 0.05);compared with benign ovarian tumors,serum CA125 and CA199 levels in patients with ovarian malignant tumors were higher,with significant difference (P < 0.05).The detection rates of contrast-enhanced ultrasound combined with tumor markers were higher than those of ultrasound or tumor markers alone,and were in accordance with pathological criteria.Conclusions The application of combined contrast-enhanced ultrasound and tumor markers in the diagnosis of ovarian benign and malignant tumors has a high detection rate,can significantly improve the accuracy of clinical detection,and provide a strong basis for treatment.
8.Ferroptosis: A Novel Anti-tumor Action for Cisplatin.
Jipeng GUO ; Bingfei XU ; Qi HAN ; Hongxia ZHOU ; Yun XIA ; Chongwen GONG ; Xiaofang DAI ; Zhenyu LI ; Gang WU
Cancer Research and Treatment 2018;50(2):445-460
PURPOSE: Ferroptosis is a new mode of regulated cell death, which is completely distinct from other cell death modes based on morphological, biochemical, and genetic criteria. This study evaluated the therapeutic role of ferroptosis in classic chemotherapy drugs, including the underlying mechanism. MATERIALS AND METHODS: Cell viabilitywas detected by using the methylthiazoltetrazlium dye uptake method. RNAiwas used to knockout iron-responsive element binding protein 2, and polymerase chain reaction, western blot was used to evaluate the efficiency. Intracellular reduced glutathione level and glutathione peroxidases activitywere determined by related assay kit. Intracellularreactive oxygen species levelswere determined by flowcytometry. Electron microscopywas used to observe ultrastructure changes in cell. RESULTS: Among five chemotherapeutic drugs screened in this study, cisplatin was found to be an inducer for both ferroptosis and apoptosis in A549 and HCT116 cells. The depletion of reduced glutathione caused by cisplatin and the inactivation of glutathione peroxidase played the vital role in the underlying mechanism. Besides, combination therapy of cisplatin and erastin showed significant synergistic effect on their anti-tumor activity. CONCLUSION: Ferroptosis had great potential to become a new approach in anti-tumor therapies and make up for some classic drugs, which open up a new way for their utility in clinic.
Apoptosis
;
Blotting, Western
;
Carrier Proteins
;
Cell Death
;
Cisplatin*
;
Drug Therapy
;
Glutathione
;
Glutathione Peroxidase
;
HCT116 Cells
;
Methods
;
Oxygen
;
Peroxidases
;
Polymerase Chain Reaction
9.Meta analysis on correlation between living quality of Chinese empty-nest elderly and social support based on Pearson correlation coefficient
Shasha LI ; Lina WANG ; Xu E ; Chongwen WU
Chongqing Medicine 2018;47(1):66-70
Objective To adopt the meta analysis to evaluate the living quality of empty-nest elderly based on Pearson and Spearson correlation coefficients.Methods The databases including Cochmne library,PubMed,PIDQuest,Medline,Springerlink,CMB,CNKI,VIP and WanFang Data were retrieved by using the network databases with the retrieval time limit until July 2016.The literatures on the correlation between the social support and living quality of Chinese empty-nest elderly were searched.The included studies were screened according to the inclusion and exclusion criteria.After extracting data and appraising the quality of the included studies,the meta analysis was conducted by using STATA11.0 software.Results Five articles were included.The literature quality was good as a whole.The total sample amounts were 2 485 subjects,including 1 201 males and 1 284 females.The meta analysis showed that merge correlation coefficient of social support and living quality,and 95 % confidence interval(CI)were 0.287 (0.252,0.329);which of social support utilization degree and living quality were 0.232 (0.191,0.274);which of subjective support and living quality were 0.260 (0.224,0.298),which of objective support and living quality were 0.139 (0.101,0.179),after merge,the correlation coefficient of social support was highest.The living quality and social support total score were increased with the samples amounts increase,and the correlation was accordingly decreased.The correlation coefficient measured by random sample method was higher than that measured by the non-random sample method.The correlation coefficient and social support in southern empty-nest elderly was higher than that of northern empty-nest elderly.Conclusion The living quality in Chinese empty-nest elderly has a correlation with the social support,which is mainly affected by subjective support and support utilization degree.
10.Performance evaluation of paramagnetic particles chemiluminescence micro-particle immunoassay for determination of serum vitamin B12
Chongwen AN ; Haixia LI ; Qun MENG ; Jianping HU ; Xiangdong XU
Chinese Journal of Immunology 2014;(11):1508-1513
Objective:To evaluate the performance of paramagnetic particles chemiluminescence microparticle immunoassay ( CMIA) for detection of serum Vitamin B12 ( VitB12 ).Methods: Analysed CMIA system precision, accuracy, anti-interference, analytical measuring range( AMR) ,clinical reportable range ( CRR) and biological reference interval were evaluated,according to the clinical and laboratory standards institude ( CLSI) EP5-A2,EP15-A2,EP7-A2,EP6-A,C28-A3c guidelines.To assess the accuracy,we used the reference material SRM 1955 from national institute of standards and technology ( NIST ) and external quality assessment ( EQA) samples ( LN5-B and K-C) from CAP.Results:The precisions of within-run and between-run were less than standard of manu-facturer when the concentration of VitB12 was 108.84-874.43 pmol/L.The results of SRM1955 met the allowable range of the target val-ue.The results of EQA samples( K-C and LN5-B) also up to the CAP calibration and validation/linear evaluation error limits stipulated standards,and the results through linear verification when the concentration of VitB12 was 89-1 057 pmol/L.The 95% verification interval contains the specified value also.The relative deviation was less than external quality assessment standard from national center for clinical laboratory ( TEa:target value ±25%).Anti-interference evaluation showed without significant interferenc when TG ≤20 mmol/L,Bil ≤300 μmol/L VitC≤1.5 g/L to the VitB12 detection system ( CMIA).AMR validation showed determines the best fit equation was linear equation polynomial.There was the linear relationship when the concentration of VitB12 was 0-1 107 pmol/L.The upper limit of CRR was 110 700 pmol/L,the maximum dilution was 100 times.Biological reference interval validation showed that the overall level of VitB12 in this study reference individuals conform to the standard of manufacturer statement for the population,the overall level of VitB12 in female little higher than male,but no significant differences.Conclusion:Performance of CMIA for detection of serum VitB12 basically met needs of laboratory,which can provide reliable results of VitB12 for laboratory,provide information for the VitB12 status of population in the laboratory evaluation.

Result Analysis
Print
Save
E-mail