1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Olfactory diagnostic analysis system based on a low-pressure chamber,simulated weightless human bedridden volunteers,and general population oral odor mapping analysis
Quanchun FAN ; Chong XU ; Junlian LIU ; Xiaorui WU ; Yu LIU ; Jiaping WANG ; Shuang ZHAO ; Yongzhi LI
Space Medicine & Medical Engineering 2025;36(4):380-384
Objective Hypobaric chamber and simulated weightless bed are essential methods for aerospace medical research,and conducting state assessment of volunteers before and after hypobaric chamber and simulated weightless bed tests is an essential guideline for aerospace implementation medicine.To further improve the efficiency of human condition assessment,in addition to the conventional biochemical and physiological indicators,the human oral exhaled gas can be used for condition assessment,and the olfactometry acquisition equipment and analysis software can collect and detect most volatile gases to complete the human oral exhaled gas data acquisition.Conducting comparative analysis of olfactory mapping data from different populations may be a means to assess the status of the body.Methods The olfactometry acquisition equipment was used to collect the oral exhaled breath olfactometry profiles of the general population,hypobaric cabin volunteers,and ambulatory volunteers.The olfactometry analysis software was used to calculate the 12 eigenvalues of the olfactometry profiles and the t-SNE downscaling,and the radar plots were used to analyze the olfactometry profiles of the general population,low-pressure cabin volunteers,and ambulatory volunteers respectively.A comparative analysis of different populations was conducted.Results(1)The t-SNE mapping data of the general population and the ambulatory volunteers were almost indistinguishable;(2)the t-SNE mapping data of the hypobaric cabin volunteers and the general population had a slight overlap,but the distinguishability of the vast majority of the t-SNE mapping data was obvious;(3)the t-SNE mapping data of the hypobaric cabin volunteers and the ambulatory volunteers were distinguishable with no overlap,and the ambulatory t SNE data are highly aggregated,and the distribution of t-SNE data in low-pressure cabin is more discrete;(4)there are 2-3 sensors with large eigenvalues and a large range of variation for both low-pressure cabin volunteers and recumbent volunteers after training activities,and the common sensor with a large range of variation is S6.Conclusion Olfactory diagnostic analysis mapping may be a means to assess the health status of the body and may be useful for spaceflight health status assessment in the future.The analysis and application of flight health state assessment can be a reference in the future.
7.Development of a High-throughput Sequencing Platform for Detection of Viral Encephalitis Pathogens Based on Amplicon Sequencing
Li Ya ZHANG ; Zhe Wen SU ; Chen Rui WANG ; Yan LI ; Feng Jun ZHANG ; Hui Sheng LIU ; He Dan HU ; Xiao Chong XU ; Yu Jia YIN ; Kai Qi YIN ; Ying HE ; Fan LI ; Hong Shi FU ; Kai NIE ; Dong Guo LIANG ; Yong TAO ; Tao Song XU ; Feng Chao MA ; Yu Huan WANG
Biomedical and Environmental Sciences 2024;37(3):294-302
Objective Viral encephalitis is an infectious disease severely affecting human health.It is caused by a wide variety of viral pathogens,including herpes viruses,flaviviruses,enteroviruses,and other viruses.The laboratory diagnosis of viral encephalitis is a worldwide challenge.Recently,high-throughput sequencing technology has provided new tools for diagnosing central nervous system infections.Thus,In this study,we established a multipathogen detection platform for viral encephalitis based on amplicon sequencing. Methods We designed nine pairs of specific polymerase chain reaction(PCR)primers for the 12 viruses by reviewing the relevant literature.The detection ability of the primers was verified by software simulation and the detection of known positive samples.Amplicon sequencing was used to validate the samples,and consistency was compared with Sanger sequencing. Results The results showed that the target sequences of various pathogens were obtained at a coverage depth level greater than 20×,and the sequence lengths were consistent with the sizes of the predicted amplicons.The sequences were verified using the National Center for Biotechnology Information BLAST,and all results were consistent with the results of Sanger sequencing. Conclusion Amplicon-based high-throughput sequencing technology is feasible as a supplementary method for the pathogenic detection of viral encephalitis.It is also a useful tool for the high-volume screening of clinical samples.
8.Development of a Traditional Chinese Medicine syndrome diagnosis scale for long-term simulated weightlessness experiments
Hongzhi SHI ; Chong XU ; Jiatuo XU ; Quanchun FAN ; Junlian LIU ; Liping TU ; Xiaojuan HU ; Chengpu ZHANG ; Shuang ZHAO ; Tao MI ; Yongzhi LI ; Yinghui LI
Space Medicine & Medical Engineering 2024;35(1):8-14
Objective To develop a Traditional Chinese Medicine(TCM)syndrome diagnosis scale suitable for evaluating the overall health status of participants in long-term simulated weightlessness experiments,and preliminarily evaluate its reliability and validity.Methods Based on the understanding of the pathogenesis of TCM in different stages of long-term manned spaceflight,a scale was developed through literature research and expert consultation.Test-retest reliability and internal consistency coefficient were used to test the reliability of the scale.Item analysis and factor principal component analysis were used to evaluate the validity of the scale,and a rotating component matrix was used to analyze the correlation between each item and dimension using 36 volunteers in a 90 days head down bed rest experiment as the research subjects.Results The scale contains eight dimensions and 57 items.The reliability analysis showed that the correlation coefficient of the total score of the scale for the first and second tests of 30 participants was 0.889,indicating high stability of the scale.The Cronbach coefficient of the scale was 0.934,indicating very good internal consistency.The split half reliability after correction was 0.858,indicating a high reliability of the scale.The validity analysis showed that the difference between the high score group and the low score one for each of the 57 items was statistically significant(P<0.01),and the Pearson correlation coefficient between each item and the total score of the scale was greater than 0.4(P<0.001).The cumulative contribution rate of 8 common factors extracted using principal component factor analysis was 55.293%,and the results of rotating component matrix analysis,after applying TCM theory and expert feedback,had a coincidence of up to 87.5%with the initial 8 dimensions,indicating good structural validity of the scale.Conclusion The scale has good reliability and validity,and can diagnose TCM syndromes.It is suitable for long-term simulated weightlessness experiment and provides an objective and quantitative new method for evaluating the subjective feelings of participants.
9.Traditional Chinese medicine pattern identification research on health status of astronauts in long term spaceflight
Hongzhi SHI ; Chong XU ; Quanchun FAN ; Junlian LIU ; Shuang ZHAO ; Tao MI ; Chengpu ZHANG ; Xuemin YIN ; Yongzhi LI
Space Medicine & Medical Engineering 2024;35(5):302-306,318
Objective To study traditional Chinese medicine(TCM)syndrome pattern of astronauts in long term spaceflight,and to summarize and elucidate the characteristics and evolvement of their holistic functional status based on TCM Pattern Identification and Classification System.Methods The Digital TCM Diagnostic Instrument and TCM Syndrome Diagnosis Scale were used to collect information from 9 astronauts in three manned missions of China Space Station,through diagnostic methods of observation,palpation and inquiry according to CM theory.Data collection was performed at various stages before,during,and after spaceflight,a total of 32 person-time digital images of tongues and facial complexion and over 2 000 data were collected.Through data mining and analysis using four diagnostic feature fusion methods,the distribution characteristics of TCM pattern among astronauts at different stages of flight and with different physical constitutions were proposed,and the health status and evolution trend of astronauts were evaluated based on the health concept of TCM.Results ⑴The astronauts showed related manifestations of 8 TCM syndromes during long term flight,among which 4 syndromes had higher scores,including Liver Depression Transforming into Fire,Liver and Kidney Yin Deficiency,Heart Kidney Disharmony,and Spleen and Kidney Yang Deficiency.However,their syndrome differentiation were mainly based on Yin and Yang in equilibrium,with only a few individuals showing a brief deviation from the equilibrium state at a certain stage.After long-term adaptation and adjustment,they almost had returned to a state of Yin-Yang equilibrium reestablishment.⑵As the flight time increased,the proportion of Liver Depression Transforming into Fire and Qi and Blood Deficiency in Heart and Spleen syndrome increased month by month,indicating that the psychological and emotional changes and insufficient Qi and blood status during long term flight need to be focused on.⑶Physical constitution had a certain impact on the syndrome patterns during flight,the astronauts with biased constitutions had significantly higher total scores for all syndrome patterns than that of individuals with Normal-constitution,astronauts with Yin deficiency had slightly higher scores for Heart Kidney Disharmony than those with Yang(Qi)deficiency,indicating that personalized TCM conditioning measures should be developed based on the pathogenesis of TCM syndrome during different flight periods,combined with factors such as physical constitution,etc.Conclusion The research has verified the scientific nature and effectiveness of TCM pattern analysis based on"four diagnostic"methods,which could be used for achieving quantitative and comprehensive evaluation of astronaut health status from the perspective of TCM in long-term space flight.
10.Diagnostic value of cross-primer isothermal amplification technology in tuberculosis and its related influencing factors
YU Huang ; LIU Chong ; OUYANG Fan-xian ; CHEN Zhuo-lin ; CHEN Lin ; CHEN Xiao-juan ; XU Yu-ni ; CHEN Shao-wen
China Tropical Medicine 2023;23(3):240-
Abstract: Objective To analyze the value and influencing factors of cross-primer isothermal amplification technology(CPA) in clinical screening and diagnosis of tuberculosis (TB). Methods We collected 543 inpatients in the Second Affiliated Hospital of Hainan Medical College from January 1, 2018 to December 31, 2021, including 179 patients with tuberculosis, 187 patients with pneumonia and 177 patients with other diseases. The patients' sputum, alveolar lavage fluid, pleural effusion and midstream urine were detected by CPA, smear microscopy, culture method and gene detection. The value of CPA detection in the diagnosis of tuberculosis and its influencing factors were evaluated. Statistical analysis was performed using SPSS 26.0. Results The total positive rate of CPA was 14.4% (78/543), and the positive rate of sputum samples accounted for 29.1% (39/134). Among the 78 cases of CPA positive patients, the tuberculosis group accounted for 69.2% (54/78), followed by pneumonia group 21.8% (17/78), and other diseases group accounted for 9.0% (7/78). Taking CPA test as the reference method, the "sensitivity" of smear microscopy was lower than that of genetic testing and culture, while the "specificity" was higher than that of culture and gene testing, and the "missed diagnosis rate" of smear microscopy was higher than that of genetic testing and culture. CPA test positive was related to gender, ESR and pneumonia. There is a good agreement between CPA test and culture method and gene test (Kappa>0.9), and a moderate agreement between CPA test and smear microscopy (Kappa=0.616). Conclusions Sputum specimen is the best choice for CPA detection, while the value of pleural effusion detection is relatively limited. Sputum, alveolar lavage fluid and midcourse urine can be used as clinical specimens for screening and diagnosis of "tuberculosis group and other disease group", while sputum can be used for screening and diagnosis of "tuberculosis group and pneumonia group". Gender, ESR and pneumonia are the influencing factors of CPA positive patients. Therefore, CPA testing is worthy of clinical promotion, but more clinical research data are needed.

Result Analysis
Print
Save
E-mail