1.Study on the predictive model for the efficacy of neurokinin-1 receptor antagonists combined with 5-hydroxytryp-tamine 3 receptor antagonists and dexamethasone for preventing nausea and vomiting induced by highly emetogenic chemotherapy
Jingyue ZHANG ; Hanxu ZHANG ; Chong YANG ; Yinjuan SUN ; Diansheng ZHONG ; Linlin ZHANG ; Hengjie YUAN
China Pharmacy 2026;37(2):220-225
OBJECTIVE To construct a predictive model for evaluating the efficacy of a triple antiemetic regimen (neurokinin- 1 receptor antagonist+5-hydroxytryptamine 3 receptor antagonist+dexamethasone) for preventing nausea and vomiting induced by highly emetogenic chemotherapy (HEC) based on interpretable deep learning algorithms. METHODS Clinical data of cancer patients who received HEC and were treated with the standard triple antiemetic regimen in the oncology department of Tianjin Medical University General Hospital from January 2018 to December 2022 were collected retrospectively. Demographic, clinical and metabolism-related variables were integrated. After data pre-processing, two deep learning algorithms (deep random forest and dense neural network) and four machine learning algorithms (support vector machine, categorical boosting, random forest and decision tree) were used to build predictive models. Subsequently, model performance evaluation and model interpretability analysis were conducted. RESULTS Among the six candidate models, the deep random forest model demonstrated the best predictive performance on the test set, with an area under the receiver operating characteristic curve of 0.850, an accuracy of 0.911, a precision of 0.805, a recall of 0.783, an F1 score of 0.793, and a Brier score of 0.075. Interpretability analysis revealed that creatinine clearance rate (Ccr) was the key predictive factor, and low Ccr levels, female gender, younger age, highly emetogenic drugs (particularly cisplatin-containing chemotherapy regimens), and anticipatory nausea and vomiting were positively correlated with the risk of HEC-related nausea and vomiting. CONCLUSIONS The deep random forest model exhibits the best performance in predicting the efficacy of triple antiemetic regimen for preventing HEC-related nausea and vomiting. The key predictors in this model primarily include Ccr,anticipatory nausea and vomiting, gender, age, and highly emetogenic drugs.
2.Clinical Observation of Mind-Regulating and Meridians-Dredging Acupuncture Combined with Rehabilitation Training in Treating Limb Dysfunction in Recovery Period of Cerebral Infarction
Wen ZHANG ; Shanbin SUN ; Chong CHEN ; Xiaoli SUN ; Yanju LI ; Ermei CAO ; Yueguang LIANG ; Sifang CHEN ; Haowen TIAN ; Yujie YANG ; Panfu HAO
Journal of Guangzhou University of Traditional Chinese Medicine 2025;42(1):71-77
Objective To observe the clinical efficacy of mind-regulating and meridians-dredging acupuncture combined with rehabilitation training in treating limb dysfunction in recovery period of cerebral infarction(CI).Methods A total of 110 cases of patients with limb dysfunction in recovery period of CI were randomly divided into observation group and control group,55 cases in each group,the control group was given routine rehabilitation training,and the observation group was treated with mind-regulating and meridians-dredging acupuncture on the basis of intervention of the control group,the course of treatment covered two consecutive weeks.After two weeks of treatment,the clinical efficacy of the two groups was evaluated,and the changes of scores of traditional Chinese medicine(TCM)syndrome,Fugl-Meyer Assessment(FMA),Berg Balance Scale(BBS)and Modified Barthel Index(MBI)before and after treatment of patients in the two groups were observed.The changes of electromyographic signal before and after treatment were compared between the two groups.And the safety and the occurrence of adverse reactions in the two groups were evaluated.Results(1)The total effective rate was 98.18%(54/55)in the observation group and 87.27%(48/55)in the control group.The efficacy of the observation group was superior to that of the control group,the difference being statistically significant(P<0.05).(2)After treatment,the TCM syndrome scores of patients in the two groups were significantly improved(P<0.05),and the improvement in the observation group was significantly superior to that in the control group,with a statistically significant difference(P<0.05).(3)After treatment,the FMA scores of patients in the two groups improved significantly(P<0.05),and the improvement in the observation group was significantly superior to that in the control group,the difference being statistically significant(P<0.05).(4)After treatment,the BBS scores and MBI scores of the patients in the two groups improved significantly(P<0.05),and the improvement in the observation group was significantly superior to that in the control group,the difference being statistically significant(P<0.05).(5)After treatment,the root mean square value(RMS)of biceps brachii muscle elbow flexion and triceps brachii muscle elbow extention of the two groups of patients improved significantly(P<0.05),and the improvement in the observation group was significantly superior to that in the control group,the difference being statistically significant(P<0.05).(6)During the treatment,there were no obvious adverse reactions occurred in both groups.Conclusion Mind-regulating and meridians-dredging acupuncture combined with rehabilitation training in treating limb dysfunction in recovery period of CI can significantly improve the motor ability of patients,and adjust the electromyographic signals of the affected limbs,with high safety.
3.Factors affecting the prevalence of hyperuricemia in an island troop
Yongguang FANG ; Shujun SUN ; Chong TANG ; Chunyu LIU ; Qian XU ; Ying LIANG ; Huihui GUO ; Peng YANG ; Nannan CHEN
Journal of Navy Medicine 2025;46(6):574-578
Objective To analyze the factors affecting the prevalence of hyperuricemia(HUA)in an island troop.Methods A total of 1 113 soldiers stationed on an island from December 2021 to December 2022 were selected as research objects by cluster sampling.Their lifestyle and health information were collected.Physical examination and laboratory detection were conducted.Multivariate logistic regression was used to analyze the influencing factors of HUA.Results The prevalence rate of HUA was 21.02%(234/1 113).There were significant differences in the body mass index(BMI),waist-to-hip ratio,triglyceride,alanine aminotransferase,and creatinine between the soldiers with hyperuricemia and the soldiers with normal blood uric acid(P<0.05).Multivariate logistic regression analysis showed that BMI≥24(OR=1.49,95%CI:1.09-2.05),abnormal liver function(OR=2.26,95%CI:1.31-3.92),and dyslipidemia(OR=1.46,95%CI:1.01-2.12)were positively correlated with hyperuricemia;age>30 years old(OR=0.59,95%CI:0.37-0.93)and exercise time>1 h per week(OR=0.46,95%CI:0.22-0.97)were negatively correlated with HUA.Conclusion The prevalence rate of hyperuricemia is at a high level in an island troop.BMI≥24,age≤30 years old,exercise time≤1 h per week,abnormal liver function,and dyslipidemia are the risk factors for HUA.Prevention and control measures should be taken as early as possible for the soldiers with these risk factors.
4.Isolation,identification,and analysis of drug resistance and virulence genes in Escherichia coli isolated from artificially bred sika deer
Cheng-yang ZHANG ; Xue JI ; Bo-wen JIANG ; Bing LIANG ; Rong-lei HUANG ; Chong-tao DU ; Yang SUN
Chinese Journal of Zoonoses 2025;41(5):522-528
To understand the background of Escherichia coli(E.coli)carried by artificially bred sika deer and the biological characteristics of the isolated strains,such as drug resistance and pathogenicity,in April 2024,we collected 184 fresh deer fecal samples from four deer farms in Luxiang Township,Shuangyang District,Changchun City,Jilin Province,for isolation and cultivation of E.coli.The isolates were tested for drug resistance and biochemical identification with a BD PhoenixTM-100 Automated Microbiology System.The virulence genes were detected with PCR,and the strains were molecularly typed with ERIC-PCR.A total of 165 E.coli strains were isolated from 184 samples of deer feces,with an isolation rate of 89.67%.Twenty strains had a drug resistance phenotype,and the drug resistance rate was 12.12%;these strains included 15 strains of multi-drug resistant bacteria and 11 strains of ESBL-producing bacteria.Virulence gene detection indicated that the sika deer isolates carried multiple diarrhea-associated virulence genes,such as EAST-1(12.12%),eae(1.21%),stx1(7.88%),stx2(7.27%),and STa(1.82%).ERIC-PCR demonstrated that the isolates showed high polymorphism.The ESBL-producing E.coli carried by sika deer are likely to spread drug resistance in the community and livestock population.Some isolates carried multiple diarrhea-associated virulence genes,thus posing a human transmission risk.Therefore,monitoring of drug resistance and virulence genes must be strengthened,and antibiotics must be used reasonably during the breeding process to avoid excessive use and misuse.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Independent and Interactive Effects of Air Pollutants, Meteorological Factors, and Green Space on Tuberculosis Incidence in Shanghai.
Qi YE ; Jing CHEN ; Ya Ting JI ; Xiao Yu LU ; Jia le DENG ; Nan LI ; Wei WEI ; Ren Jie HOU ; Zhi Yuan LI ; Jian Bang XIANG ; Xu GAO ; Xin SHEN ; Chong Guang YANG
Biomedical and Environmental Sciences 2025;38(7):792-809
OBJECTIVE:
To assess the independent and combined effects of air pollutants, meteorological factors, and greenspace exposure on new tuberculosis (TB) cases.
METHODS:
TB case data from Shanghai (2013-2018) were obtained from the Shanghai Center for Disease Control and Prevention. Environmental data on air pollutants, meteorological variables, and greenspace exposure were obtained from the National Tibetan Plateau Data Center. We employed a distributed-lag nonlinear model to assess the effects of these environmental factors on TB cases.
RESULTS:
Increased TB risk was linked to PM 2.5, PM 10, and rainfall, whereas NO 2, SO 2, and air pressure were associated with a reduced risk. Specifically, the strongest cumulative effects occurred at various lags: PM 2.5 ( RR = 1.166, 95% CI: 1.026-1.325) at 0-19 weeks; PM 10 ( RR = 1.167, 95% CI: 1.028-1.324) at 0-18 weeks; NO 2 ( RR = 0.968, 95% CI: 0.938-0.999) at 0-1 weeks; SO 2 ( RR = 0.945, 95% CI: 0.894-0.999) at 0-2 weeks; air pressure ( RR = 0.604, 95% CI: 0.447-0.816) at 0-8 weeks; and rainfall ( RR = 1.404, 95% CI: 1.076-1.833) at 0-22 weeks. Green space exposure did not significantly impact TB cases. Additionally, low temperatures amplified the effect of PM 2.5 on TB.
CONCLUSION
Exposure to PM 2.5, PM 10, and rainfall increased the risk of TB, highlighting the need to address air pollutants for the prevention of TB in Shanghai.
China/epidemiology*
;
Humans
;
Air Pollutants/analysis*
;
Tuberculosis/epidemiology*
;
Incidence
;
Meteorological Concepts
;
Particulate Matter/adverse effects*
;
Environmental Exposure
;
Male
;
Female
;
Adult
;
Air Pollution
;
Middle Aged
10.Validation of the effectiveness of leaf position data for the linear accelerator log file
Chenlu LIU ; Xiaotong WANG ; Long SUN ; Chong XU ; Bo XUE ; Xiaohua YANG ; Guoping SHAN
Chinese Journal of Radiation Oncology 2025;34(8):796-803
Objective:To validate the effectiveness of the leaf position data of multi-leaf collimator (MLC) recorded in the Infinity medical linear accelerator log file (LF).Methods:In this study, the establishment of the film dose calibration curve involved two steps. Initially, the pixel values obtained from scanning the film were converted into net optical density values. Subsequently, a sixth-order polynomial fit was performed on the net optical density and dose data. The picket fence (PF) tests were performed on the electronic portal imaging device (EPID) and film, and the corresponding acquired PF test images were analyzed using the relative leaf travel distance, relative leaf position, relative leaf pair full-width half -maximum (FWHM), and relative leaf pair neighbor region width analysis index, and compared with the relevant results in LF. In addition, to investigate the effect of gravity on the recorded leaf position data by the Infinity medical linear accelerator LF, the above PF tests were executed at 0°, 90°, 180°, and 270° gantry angles, respectively. Intergroup differences were assessed with the Wilcoxon rank-sum test.Results:The film dose calibration curve demonstrated high goodness-of-fit, with a correlation coefficient ( R2) of 0.9994. Across all gantry angles, the dispersion of overall leaf position data for EBT3 film, EPID, and LF followed a consistent pattern based on four analysis metrics: EBT3 film > EPID > LF. Moreover, for each analysis metric, inter-tool differences in standard deviations of results were consistently below 0.1 mm, and this pattern was invariant to gantry angle. Conclusions:The leaf position data recorded in the Infinity medical linear accelerator LF have a high degree of accuracy, and can be used as reference for the actual position of the MLC leaf. Furthermore, gravitational forces exhibit negligible impact on leaf position data acquired via LF.

Result Analysis
Print
Save
E-mail