1.An Attention-weighted Tri-modal Ultrasound Network (TUS-Net) for Screening of Atypical Hepatocellular Carcinoma From LR-M Liver Nodules
He-Chong ZHANG ; Liang-Hui HUANG ; Xue-Hua WANG ; Shang-Lin JIANG ; Ying-Ying CHEN ; Ya-Guang ZENG ; Wei ZHENG
Progress in Biochemistry and Biophysics 2026;53(5):1485-1498
ObjectiveDiscriminating atypical hepatocellular carcinoma (HCC) from other malignancies in liver nodules classified as Liver Imaging Reporting and Data System category M (LR-M) remains a significant diagnostic challenge on conventional ultrasound examination. The LR-M category, originally intended to capture non-HCC malignancies, paradoxically contains up to 63% of atypical HCCs that deviate from classic enhancement patterns, leading to potential misdiagnosis and suboptimal treatment planning. While deep learning has shown promise in HCC diagnosis, most existing models rely exclusively on single-modality ultrasound, overlooking the diagnostic benefits of integrating complementary information from multiple imaging sources. To address this gap, we propose a novel attention-weighted tri-modal ultrasound network (TUS-Net) that integrates contrast-enhanced ultrasound (CEUS), B-mode ultrasound (BUS), and time-intensity curves (TICs) to improve diagnostic accuracy for these clinically challenging lesions. MethodsOur framework incorporates a three-dimensional convolutional neural network (C3D) backbone to extract spatiotemporal features from CEUS videos, capturing dynamic vascular patterns critical for lesion characterization. To effectively fuse complementary modalities, we introduce a dual-channel feature fusion module (DCFFM) that adaptively combines features from CEUS and BUS through channel-wise attention mechanisms, allowing the model to dynamically weigh the contribution of each modality based on diagnostic relevance. Additionally, we propose a temporal intensity feature fusion module (TIFFM) that leverages quantitative hemodynamic information from TICs to guide the model’s attention toward diagnostically critical temporal phases, such as arterial wash-in and portal venous washout. The model is further enhanced by automated lesion localization using YOLOX and class activation mapping for interpretability, ensuring that predictions align with clinically meaningful imaging features. ResultsEvaluated on a tri-modal ultrasound dataset comprising 161 patients with pathologically confirmed LR-M nodules (131 atypical HCC and 30 non-HCC malignancies), our model achieved an accuracy of 86.83%, a sensitivity of 92.50%, a specificity of 75.50%, and an AUC of 89.32% in screening atypical HCC. Compared to single-modality baselines, TUS-Net demonstrated superior specificity, a clinically critical metric given the higher risk associated with misclassifying non-HCC malignancies. Ablation studies confirmed the contribution of each module, with the full model outperforming both standard C3D and 3D ResNet backbones integrated with attention mechanisms. A reader study involving junior and senior radiologists further validated the clinical utility of AI assistance, showing consistent improvements in specificity and inter-reader consistency, particularly for less experienced clinicians. ConclusionThese results surpass existing benchmark models and demonstrate the potential of our approach to enhance diagnostic precision in clinically specific cases. By intelligently fusing multi-modal ultrasound data with attention-guided mechanisms, TUS-Net offers a reliable and interpretable tool that holds promise for improving the non-invasive diagnosis of atypical HCC in challenging LR-M liver nodules.
2.An Attention-weighted Tri-modal Ultrasound Network (TUS-Net) for Screening of Atypical Hepatocellular Carcinoma From LR-M Liver Nodules
He-Chong ZHANG ; Liang-Hui HUANG ; Xue-Hua WANG ; Shang-Lin JIANG ; Ying-Ying CHEN ; Ya-Guang ZENG ; Wei ZHENG
Progress in Biochemistry and Biophysics 2026;53(5):1485-1498
ObjectiveDiscriminating atypical hepatocellular carcinoma (HCC) from other malignancies in liver nodules classified as Liver Imaging Reporting and Data System category M (LR-M) remains a significant diagnostic challenge on conventional ultrasound examination. The LR-M category, originally intended to capture non-HCC malignancies, paradoxically contains up to 63% of atypical HCCs that deviate from classic enhancement patterns, leading to potential misdiagnosis and suboptimal treatment planning. While deep learning has shown promise in HCC diagnosis, most existing models rely exclusively on single-modality ultrasound, overlooking the diagnostic benefits of integrating complementary information from multiple imaging sources. To address this gap, we propose a novel attention-weighted tri-modal ultrasound network (TUS-Net) that integrates contrast-enhanced ultrasound (CEUS), B-mode ultrasound (BUS), and time-intensity curves (TICs) to improve diagnostic accuracy for these clinically challenging lesions. MethodsOur framework incorporates a three-dimensional convolutional neural network (C3D) backbone to extract spatiotemporal features from CEUS videos, capturing dynamic vascular patterns critical for lesion characterization. To effectively fuse complementary modalities, we introduce a dual-channel feature fusion module (DCFFM) that adaptively combines features from CEUS and BUS through channel-wise attention mechanisms, allowing the model to dynamically weigh the contribution of each modality based on diagnostic relevance. Additionally, we propose a temporal intensity feature fusion module (TIFFM) that leverages quantitative hemodynamic information from TICs to guide the model’s attention toward diagnostically critical temporal phases, such as arterial wash-in and portal venous washout. The model is further enhanced by automated lesion localization using YOLOX and class activation mapping for interpretability, ensuring that predictions align with clinically meaningful imaging features. ResultsEvaluated on a tri-modal ultrasound dataset comprising 161 patients with pathologically confirmed LR-M nodules (131 atypical HCC and 30 non-HCC malignancies), our model achieved an accuracy of 86.83%, a sensitivity of 92.50%, a specificity of 75.50%, and an AUC of 89.32% in screening atypical HCC. Compared to single-modality baselines, TUS-Net demonstrated superior specificity, a clinically critical metric given the higher risk associated with misclassifying non-HCC malignancies. Ablation studies confirmed the contribution of each module, with the full model outperforming both standard C3D and 3D ResNet backbones integrated with attention mechanisms. A reader study involving junior and senior radiologists further validated the clinical utility of AI assistance, showing consistent improvements in specificity and inter-reader consistency, particularly for less experienced clinicians. ConclusionThese results surpass existing benchmark models and demonstrate the potential of our approach to enhance diagnostic precision in clinically specific cases. By intelligently fusing multi-modal ultrasound data with attention-guided mechanisms, TUS-Net offers a reliable and interpretable tool that holds promise for improving the non-invasive diagnosis of atypical HCC in challenging LR-M liver nodules.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Exploration and Practice of a Comprehensive Model of"Teaching,Science and Ideology Trinity"to Enhance the Scientific Research Comprehensive Ability of Medical Students
Xiao-Hong YANG ; Chun-Hong HUANG ; Da-Ya LUO ; Wei-Feng ZHU ; Mu-Ying YING ; Yi JIANG ; Jing-Chong GUO ; Hao-Tang LIAO ; Xiao-Li TANG
Chinese Journal of Biochemistry and Molecular Biology 2025;41(9):1360-1368
The integration of science and education is not only an important strategy for promoting social progress and technological development,but also a modern form of higher education aiming at cultivating innovative talents.Conducting scientific research training for undergraduate medical students is one of the important ways to cultivate their innovative abilities and comprehensive qualities.Our team proposed a"teaching,science,and ideology trinity"teaching model to comprehensively cultivate students' scientific research comprehensive abilities under the value orientation of ideological and political education by or-ganically integrating molecular biology experimental teaching with the scientific research training of under-graduate medical students.In this teaching activity,taking the experiment of gene polymorphism as an example,our team selected students with research potential from the whole grade and divided them into 4 project groups that were instructed by 4 teachers.The students were trained in the whole process of scien-tific research,including topic selection,project writing,experimental designing,application for research ethics,and project summary.Our team has always adhered to student-contentedness of educational con-cepts to stimulate students' intrinsic motivation throughout the teaching process.Students are the design-ers and implementers of the project,and teachers are only guides and promoters of learning.After this training,students not only became familiar with the writing and implementation of scientific research pro-jects,but also improved their literature reading,experimental designing,experimental skills,and prob-lem-solving abilities.More importantly,this teaching activity also cultivated students' awareness of re-search ethics and academic moral standards.
5.Exploration and Practice of a Comprehensive Model of"Teaching,Science and Ideology Trinity"to Enhance the Scientific Research Comprehensive Ability of Medical Students
Xiao-Hong YANG ; Chun-Hong HUANG ; Da-Ya LUO ; Wei-Feng ZHU ; Mu-Ying YING ; Yi JIANG ; Jing-Chong GUO ; Hao-Tang LIAO ; Xiao-Li TANG
Chinese Journal of Biochemistry and Molecular Biology 2025;41(9):1360-1368
The integration of science and education is not only an important strategy for promoting social progress and technological development,but also a modern form of higher education aiming at cultivating innovative talents.Conducting scientific research training for undergraduate medical students is one of the important ways to cultivate their innovative abilities and comprehensive qualities.Our team proposed a"teaching,science,and ideology trinity"teaching model to comprehensively cultivate students' scientific research comprehensive abilities under the value orientation of ideological and political education by or-ganically integrating molecular biology experimental teaching with the scientific research training of under-graduate medical students.In this teaching activity,taking the experiment of gene polymorphism as an example,our team selected students with research potential from the whole grade and divided them into 4 project groups that were instructed by 4 teachers.The students were trained in the whole process of scien-tific research,including topic selection,project writing,experimental designing,application for research ethics,and project summary.Our team has always adhered to student-contentedness of educational con-cepts to stimulate students' intrinsic motivation throughout the teaching process.Students are the design-ers and implementers of the project,and teachers are only guides and promoters of learning.After this training,students not only became familiar with the writing and implementation of scientific research pro-jects,but also improved their literature reading,experimental designing,experimental skills,and prob-lem-solving abilities.More importantly,this teaching activity also cultivated students' awareness of re-search ethics and academic moral standards.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Medication rules and mechanisms of treating chronic renal failure by Jinling medical school based on data mining, network pharmacology, and experimental validation.
Jin-Long WANG ; Wei WU ; Yi-Gang WAN ; Qi-Jun FANG ; Yu WANG ; Ya-Jing LI ; Fee-Lan CHONG ; Sen-Lin MU ; Chu-Bo HUANG ; Huang HUANG
China Journal of Chinese Materia Medica 2025;50(6):1637-1649
This study aims to explore the medication rules and mechanisms of treating chronic renal failure(CRF) by Jinling medical school based on data mining, network pharmacology, and experimental validation systematically and deeply. Firstly, the study selected the papers published by the inherited clinicians in Jinling medical school in Chinese journals using the subject headings named "traditional Chinese medicine(TCM) + chronic renal failure", "TCM + chronic renal inefficiency", or "TCM + consumptive disease" in China National Knowledge Infrastructure, Wanfang, and VIP Chinese Science and Technology Periodical Database and screened TCM formulas for treating CRF according to inclusion and exclusion criteria. The study analyzed the frequency of use of single TCM and the four properties, five tastes, channel tropism, and efficacy of TCM used with high frequency and performed association rule and clustering analysis, respectively. As a result, a total of 215 TCM formulas and 235 different single TCM were screened, respectively. The TCM used with high frequency included Astragali Radix, Rhei Radix et Rhizoma, Salviae Miltiorrhizae Radix et Rhizoma, Poria, and Atractylodis Macrocephalae Rhizoma(top 5). The single TCM characterized by "cold properties, sweet flavor, and restoring spleen channel" and the TCM with the efficacy of tonifying deficiency had the highest frequency of use, respectively. Then, the TCM with the rules of "blood-activating and stasis-removing" and "diuretic and dampness-penetrating" appeared. In addition, the core combination of TCM [(Hexin Formula, HXF)] included "Astragali Radix, Rhei Radix et Rhizoma, Poria, Salviae Miltiorrhizae Radix, and Angelicae Sinensis Radix". The network pharmacology analysis showed that HXF had 91 active compounds and 250 corresponding protein targets including prostaglandin-endoperoxide synthase 2(PTGS2), PTGS1, sodium voltage-gated channel alpha subunit 5(SCN5A), cholinergic receptor muscarinic 1(CHRM1), and heat shock protein 90 alpha family class A member 1(HSP90AA1)(top 5). Gene Ontology(GO) function analysis revealed that the core targets of HXF predominantly affected biological processes, cellular components, and molecular functions such as positive regulation of transcription by ribonucleic acid polymerase Ⅱ and DNA template transcription, formation of cytosol, nucleus, and plasma membrane, and identical protein binding and enzyme binding. Kyoto Encyclopedia of Genes and Genomes(KEGG) analysis revealed that CRF-related genes were involved in a variety of signaling pathways and cellular metabolic pathways, primarily involving "phosphatidylinositol 3-kinase(PI3K)-protein kinase B(Akt) pathway" and "advanced glycation end products-receptor for advanced glycation end products". Molecular docking results showed that the active components in HXF such as isomucronulatol 7-O-glucoside, betulinic acid, sitosterol, and przewaquinone B might be crucial in the treatment of CRF. Finally, a modified rat model with renal failure induced by adenine was used, and the in vivo experimental confirmation was performed based on the above-mentioned predictions. The results verify that HXF can regulate mitochondrial autophagy in the kidneys and the PI3K-Akt-mammalian target of rapamycin(mTOR) signaling pathway activation at upstream, so as to alleviate renal tubulointerstitial fibrosis and then delay the progression of CRF.
Data Mining
;
Drugs, Chinese Herbal/chemistry*
;
Network Pharmacology
;
Humans
;
Kidney Failure, Chronic/metabolism*
;
Medicine, Chinese Traditional
;
China
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail