1.Mechanistic study of Tripterygium wilfordii multiglucoside in improving nephrotic syndrome via regulating the HIF-1α/miR-155-5p/Nrf2 pathway
Yifan TAO ; Chundong SONG ; Xu WANG ; Chong ZHANG ; Ying SU ; Xidong JIA ; Haoran JIANG
China Pharmacy 2026;37(5):602-606
OBJECTIVE To study the improvement effect and mechanism of Tripterygium wilfordii multiglucoside (TWM) on nephrotic syndrome in rats. METHODS The nephrotic syndrome model was established by intravenous injection of adriamycin via the tail vein. The modeling rats were randomly divided into the model group (distilled water), prednisone group (10 mg/kg), and TWM high- and low-dose groups (10 and 5 mg/kg, respectively). Additionally, blank group (distilled water) without model induction was established. Each group consisted of 9 rats. Rats in each group were administered the corresponding drugs or distilled water by gavage, once a day, for 6 consecutive weeks. The histopathological morphology of kidney tissues in rats was observed; the levels of 24-hour urinary protein (24 h-UTP) and serum biochemical indicators [albumin (ALB), blood urea nitrogen (BUN), serum creatinine (SCr), cholesterol (CHOL), and triglyceride (TG)] in rats were determined; the levels of oxidative stress indicators [superoxide dismutase (SOD), malondialdehyde (MDA)] in kidney tissue of rats were determined; expressions of hypoxia-inducible factor-1α (HIF-1α)/microRNA-155-5p (miR-155-5p)/nuclear factor erythriod 2- related factor 2 (Nrf2) signaling pathway-related mRNA and protein in the renal tissues of rats were detected. RESULTS Compared with the blank group, the rats in the model group exhibited disordered renal tissue structure, with a small amount of glomerular necrosis and edema of the renal tubular epithelial cells. 24 h-UTP, serum levels of SCr, BUN, CHOL and TG, MDA content, mRNA and protein expressions of HIF-1α and Keap1 as well as the expression of miR-155-5p in renal tissues were increased significantly ( P <0.05). Serum level of ALB, SOD level in renal tissue as well as mRNA and protein expressions of Nrf2 were decreased significantly ( P <0.05). Compared with the model group, TWM high-dose and low-dose groups exhibited significant improvements in renal injury, with notable reversals in the levels of the above quantitative indicators ( P <0.05). CONCLUSIONS TWM can alleviate oxidative stress-induced damage and thereby improve nephrotic syndrome in rats by regulating the HIF-1α/miR-155-5p/Nrf2 signaling pathway.
2.Preparation of γ-Polyglutamic Acid Complex Medical Coating and Analysis of Its Antibacterial Properties
Ke LUAN ; Dong-Hua XU ; Ming-Zhe WANG ; Xu ZHANG ; Qiu-Yan YAN ; De-An SHI ; Rui WANG ; Heng-Chong SHI ; Hong XU
Chinese Journal of Analytical Chemistry 2025;53(7):1196-1203
Medical device related infections caused by bacteria are common complications in clinical practice,and preventing bacterial colonization on the surface of medical materials is one of the important challenges in the medical field.Therefore,there is an urgent need to construct medical coatings that combine antibacterial properties and biocompatibility.In this study,a γ-polyglutamic acid(γ-PGA)complex with long-chain alkyl quaternary ammonium salts formed by electrostatic and hydrophobic interactions was prepared,which was insoluble in water but soluble in organic solvents(e.g.,ethanol),and was capable of constructing antimicrobial coatings on the surfaces of medical materials in a simple and efficient manner.The bactericidal effect of the coating was verified using viable bacteria counting experiments,and the results showed that the bactericidal rate of the coated thermoplastic polyurethane(TPU)membrane against Staphylococcus aureus was greater than 99.9%compared with that of the uncoated TPU membrane.In addition,a cytotoxicity assay was performed using the L929 fibroblast and cell proliferation detection kit(CCK-8),which showed that the survival rate of L929 fibroblasts on coated TPU was greater than 90%.Meanwhile,the hemolysis rate of coated erythrocytes was tested using fresh rabbit red blood cells(RBCs),and the hemolysis rate on the coated TPU surface was 1.5%.The above results indicated that the coating had good biocompatibility.The preparation method of medical antibacterial coating reported in this study provided a new idea for preventing bacterial infections related to implantable/interventional medical devices.
3.Factors affecting the prevalence of hyperuricemia in an island troop
Yongguang FANG ; Shujun SUN ; Chong TANG ; Chunyu LIU ; Qian XU ; Ying LIANG ; Huihui GUO ; Peng YANG ; Nannan CHEN
Journal of Navy Medicine 2025;46(6):574-578
Objective To analyze the factors affecting the prevalence of hyperuricemia(HUA)in an island troop.Methods A total of 1 113 soldiers stationed on an island from December 2021 to December 2022 were selected as research objects by cluster sampling.Their lifestyle and health information were collected.Physical examination and laboratory detection were conducted.Multivariate logistic regression was used to analyze the influencing factors of HUA.Results The prevalence rate of HUA was 21.02%(234/1 113).There were significant differences in the body mass index(BMI),waist-to-hip ratio,triglyceride,alanine aminotransferase,and creatinine between the soldiers with hyperuricemia and the soldiers with normal blood uric acid(P<0.05).Multivariate logistic regression analysis showed that BMI≥24(OR=1.49,95%CI:1.09-2.05),abnormal liver function(OR=2.26,95%CI:1.31-3.92),and dyslipidemia(OR=1.46,95%CI:1.01-2.12)were positively correlated with hyperuricemia;age>30 years old(OR=0.59,95%CI:0.37-0.93)and exercise time>1 h per week(OR=0.46,95%CI:0.22-0.97)were negatively correlated with HUA.Conclusion The prevalence rate of hyperuricemia is at a high level in an island troop.BMI≥24,age≤30 years old,exercise time≤1 h per week,abnormal liver function,and dyslipidemia are the risk factors for HUA.Prevention and control measures should be taken as early as possible for the soldiers with these risk factors.
4.Setd2 overexpression rescues bivalent gene expression during SCNT-mediated ZGA.
Xiaolei ZHANG ; Ruimin XU ; Yuyan ZHAO ; Yijia YANG ; Qi SHI ; Hong WANG ; Xiaoyu LIU ; Shaorong GAO ; Chong LI
Protein & Cell 2025;16(6):439-457
Successful cloning through somatic cell nuclear transfer (SCNT) faces significant challenges due to epigenetic obstacles. Recent studies have highlighted the roles of H3K4me3 and H3K27me3 as potential contributors to these obstacles. However, the underlying mechanisms remain largely unclear. In this study, we generated genome-wide maps of H3K4me3 and H3K27me3 in mouse pre-implantation NT embryos. Our analysis revealed that aberrantly over-represented broad H3K4me3 domain and H3K27me3 signal lead to increased bivalent marks at gene promoters in NT embryos compared with naturally fertilized (NF) embryos at the 2-cell stage, which may link to relatively low levels of H3K36me3 in NT 2-cell embryos. Notably, the overexpression of Setd2, a H3K36me3 methyltransferase, successfully restored multiple epigenetic marks, including H3K36me3, H3K4me3, and H3K27me3. In addition, it reinstated the expression levels of ZGA-related genes by reestablishing H3K36me3 at gene body regions, which excluded H3K27me3 from bivalent promoters, ultimately improving cloning efficiency. These findings highlight the excessive bivalent state at gene promoters as a potent barrier and emphasize the removal of these barriers as a promising approach for achieving higher cloning efficiency.
Animals
;
Mice
;
Histone-Lysine N-Methyltransferase/biosynthesis*
;
Histones/genetics*
;
Nuclear Transfer Techniques
;
Female
;
Gene Expression Regulation, Developmental
;
Promoter Regions, Genetic
;
Epigenesis, Genetic
;
Embryo, Mammalian/metabolism*
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Short-term Effects of Fine Particulate Matter and its Constituents on Acute Exacerbations of Chronic Bronchitis: A Time-stratified Case-crossover Study.
Jing Wei ZHANG ; Jian ZHANG ; Peng Fei LI ; Yan Dan XU ; Xue Song ZHOU ; Xiu Li TANG ; Jia QIU ; Zhong Ao DING ; Ming Jia XU ; Chong Jian WANG
Biomedical and Environmental Sciences 2025;38(3):389-393

Result Analysis
Print
Save
E-mail