1.Super-elderly treatment resistant depression patient treated with modified electroconvulsive therapy: a case report
Shan CHONG ; Na'na XIONG ; Tengteng FAN
Sichuan Mental Health 2025;38(1):84-88
The paper reported a case of super-elderly patient with treatment-resistant depression who underwent modified electroconvulsive therapy (MECT). The patient was an 87-year-old female presented to the hospital with an 8-year history of depressive disorder marked by intermittent episodes, who exhibited poor response to various antidepressants while achieved a significant improvement after receiving MECT. In the past two years, the patient experienced a recurrence of depression following life stress events. The condition showed improvement with the administration of MECT. However, after discontinuation of MECT, the depression relapsed multiple times, prompting rehospitalization for continued MECT to sustain clinical benefits. The patient demonstrated overall tolerable adherence to MECT. Based on research of domestic and international, this paper explored treatment options for super-elderly patients with treatment-resistant depression, aiming to provide insights into the application of MECT in the management of depression among super-elderly patients with depression. [Funded by National Key Research and Development Project (number, 2019YFC0118502)]
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Inhibition of the growth, migration, and angiogenesis of esophageal squamous cell carcinoma by metformin by regulating ALKBH3 expression
Shan LIU ; Yue PAN ; Zhuo ZHANG ; Chong LIU ; Xueman LI ; Fei XIONG
Journal of International Oncology 2025;52(6):343-352
Objective:To investigate the effects of metformin on esophageal squamous cell carcinoma cell growth, migration and angiogenesis by regulating the expression of ALKBH3.Methods:Human esophageal cancer TE-1 cells were treated with different concentrations (0, 0.5, 1.0, 2.0, 4.0, 8.0 mmol/L) of metformin, and they were divided into a blank control group, low- (0.5 mmol/L), medium- (1.0 mmol/L), and high- (2.0 mmol/L) concentration metformin groups, a metformin (2.0 mmol/L) +pcDNA-NC group, and a metformin (2.0 mmol/L) +pcDNA-ALKBH3 group. The cell viability was determined by the CCK-8 method. The cell proliferation ability was detected by the clone formation assay. The cell migration and invasion abilities were examined by the Transwell assay. The cell apoptosis was detected by flow cytometry. The tube formation ability of cells was detected by the angiogenesis assay. A xenograft tumor model was constructed using 4- to 6-week-old male BALB/c thymus-less nude mice, which were divided into a model control group, a metformin group, a metformin+pcDNA-NC group, and a metformin+pcDNA-ALKBH3 group using a random number table method, and with six in each group. And the volume and weight of the tumor were measured. The protein expression levels of apoptosis-related proteins Bcl-2, Bax, ALKBH3 and vascular endothelial growth factor A (VEGF-A) were detected by Western blotting. The expression of CD31 protein was detected by immunohistochemistry.Results:After treating TE-1 cells with 0, 0.5, 1.0, 2.0, 4.0, and 8.0 mmol/L metformin for 48 hours, the cell viability was (100.00±0.00) %, (90.31±5.23) %, (81.25±8.65) %, (63.52±6.80) %, (54.64±5.35) %, and (31.48±4.21) %, respectively, with a statistically significant difference ( F=98.11, P<0.001). There were statistically significant differences in cell viability between 0.5, 1.0, 2.0, 4.0, 8.0 mmol/L and 0 mmol/L (all P<0.05). The IC 50 of metformin for TE-1 cells was 4.46 mmol/L. The numbers of colony formations of TE-1 cells in the blank control group, low-, medium-, and high-concentration metformin groups, metformin+pcDNA-NC group, and metformin+pcDNA-ALKBH3 group were 153.15±13.55, 134.80±11.62, 116.24±10.43, 93.17±8.85, 89.39±8.46, 110.26±7.21, respectively, with a statistically significant difference ( F=34.28, P<0.001); the numbers of colony formations of TE-1 cells in the metformin groups at different concentrations decreased significantly with the increase in metformin concentration (both P<0.05); compared with the metformin+pcDNA-NC group, the number of colony formations of cells in the metformin+pcDNA-ALKBH3 group increased ( P<0.05). The numbers of migration of TE-1 cells of 6 groups were 152.13±13.40, 133.85±10.72, 115.28±8.64, 91.16±7.89, 85.39±7.23, 116.85±8.36, the numbers of invasion were 135.22±10.77, 112.07±9.53, 86.30±7.45, 69.53±6.74, 65.81±5.65, 79.80±6.32, respectively, with statistically significant differences ( F=41.35, P<0.001; F=69.06, P<0.001); the numbers of migrated and invaded cells in the metformin groups at different concentrations decreased significantly with the increase in metformin concentration (all P<0.05); compared with the metformin+pcDNA-NC group, the numbers of migrated and invaded cells in the metformin+pcDNA-ALKBH3 group increased significantly (both P<0.05). The apoptosis rates of TE-1 cells in 6 groups were (3.22±1.13) %, (13.82±1.90) %, (22.67±2.53) %, (29.18±3.24) %, (26.84±2.75) %, and (16.36±1.63) %, respectively, with a statistically significant difference ( F=103.66, P<0.001); the apoptosis rates of cells in the metformin groups at different concentrations gradually increased with the increase in metformin concentration (both P<0.05); compared with the metformin+pcDNA-NC group, the apoptosis rate of cells in the metformin+pcDNA-ALKBH3 group was relatively lower ( P<0.05). The tubular structure of cells in blank control group was intact, and there were different degrees of damage to the tubular structure of cells in the low-, medium-, high- concentration metformin groups, the degree of damage to the tubular structure of cells in the metformin+pcDNA-ALKBH3 group was reduced. The numbers of cellular tubular structures of TE-1 cells in the 6 groups were 38.35±3.20, 27.15±2.64, 15.92±3.14, 7.39±1.50, 8.61±1.37, and 29.33±4.20, respectively, with a statistically significant difference ( F=113.92, P<0.001); the number of cellular tubular structures in the low-, medium-, and high- concentration metformin groups gradually decreased (both P<0.05); the number of cellular tubular structures in the metformin+pcDNA-ALKBH3 group was more than that in the metformin+pcDNA-NC group ( P<0.05). There were statistically significant differences in the protein expressions of Bcl-2, Bax, ALKBH3, and VEGF-A in TE-1 cells among 6 groups ( F=56.36, P<0.001; F=57.26, P<0.001; F=159.30, P<0.001; F=132.89, P<0.001); compared with the blank control group, the protein expressions of Bcl-2, ALKBH3, and VEGF-A in the metformin groups at different concentrations decreased, while the protein expression of Bax increased (all P<0.05); compared with the metformin+pcDNA-NC group, the protein expressions of Bcl-2, ALKBH3, and VEGF-A in the metformin+pcDNA-ALKBH3 group increased, and the expression level of Bax decreased (all P<0.05). The weights of tumors in the model control group, metformin group, metformin+pcDNA-NC group, and metformin+pcDNA-ALKBH3 group were (1.16±0.12), (0.46±0.05), (0.50±0.06), (1.19±0.14) g, the volumes of tumors were (878.36±108.93), (413.59±50.23), (439.78±51.39), (793.75±96.98) mm 3, with statistically significant differences ( F=96.61, P<0.001; F=51.90, P<0.001); the weight of tumors were lower and the volume of tumors were smaller in the metformin group than those in the model control group (both P<0.05), the weight of tumors were higher and the volume of tumors were bigger in the metformin+pcDNA-ALKBH3 group than those in the metformin group and the metformin+pcDNA-NC group (all P<0.05). CD31 was mainly distributed in the cytoplasm and cell membrane of tumor cells. There were statistically significant differences in the positive rates of CD31 and the protein expression levels of VEGF-A in transplanted tumor tissues among 4 groups ( F=7.12, P=0.002; F=48.81, P<0.001); the positive rate of CD31 and the protein expression level of VEGF-A in the metformin group were lower than those in the model control group; the positive rate of CD31 and the protein expression level of VEGF-A in the metformin+pcDNA-ALKBH3 group were higher than those in the metformin group and the metformin+pcDNA-NC group (all P<0.05) . Conclusions:Metformin may inhibit the proliferation, migration, and tumor angiogenesis of esophageal squamous cell carcinoma by reducing ALKBH3 expression.
8.Efficacy of observation screen-based manual cyclotorsion compensation in the correction of with-the-rule astigmatism during SMILE
Yalin LU ; Jian XIONG ; Fei HUANG ; Chong AI ; Fu GUI
Recent Advances in Ophthalmology 2025;45(5):365-369
Objective To evaluate the efficacy of the manual cyclotorsion compensation method based on the obser-vation screen in the correction of with-the-rule astigmatism during small incision lenticule extraction(SMILE).Methods This prospective study enrolled 40 patients who underwent SMILE and another 40 patients who underwent Q-value-guided femtosecond laser-assisted laser in situ keratomileusis(FS-LASIK)at the Ophthalmology Center of the Second Affiliated Hospital of Nanchang University from April to September 2024.Through the random number method,one eye of each pa-tient who underwent SMILE was assigned to the manual cyclotorsion compensation group(the cyclotorsion group,40 eyes),while the contralateral eye was assigned to the non-cyclotorsion group(the non-cyclotorsion group,40 eyes).Meanwhile,one eye of each patient who underwent FS-LASIK was randomly selected for the FS-LASIK group(40 eyes).The age,uncorrected distance visual acuity(UDVA),spherical power,cylindrical power,spherical equivalent(SE),and corrected distance visual acuity(CDVA)were recorded before surgery and 3 months after surgery,respectively.Astigma-tism was subjected to Alpins vector analysis,and the indicators for assessing astigmatism included target-induced astigma-tism(TIA),surgically-induced astigmatism(SIA),difference vector(DV),correction index(CI),success index(IOS),angle of error(AE),and absolute value of angle of error(|AE|).Results Before surgery,there was no significant difference in age,spherical power,cylindrical power,SE,and CDVA among the cyclotorsion group,the non-cyclotorsion group,and the FS-LASIK group(all P>0.05).At 3 months after surgery,the cyclotorsion group showed better UDVA and lower cylindrical power than the non-cyclotorsion group,with statistically significant differences(both P<0.05);howev-er,there was no significant difference in CDVA,spherical power,and SE between the two groups(all P>0.05).Besides,there was no significant difference in UDVA,CDVA,or refractive parameters between the cyclotorsion and FS-LASIK groups(all P>0.05).The Alpins vector analysis of astigmatism 3 months after surgery revealed better SIA,CI,IOS,and|AE|in the cyclotorsion group compared with the non-cyclotorsion group,with statistically significant differences(all P<0.05);however,there was no significant difference in TIA,DV,and AE between the two groups(all P>0.05).No signifi-cant differences were found between the cyclotorsion and FS-LASIK groups in any astigmatism vector parameter(all P>0.05).The linear regression analysis results indicated a high linear correlation between TIA and SIA in all groups.Conclu-sion The manual cyclotorsion compensation method based on the observation screen in the correction of with-the-rule astigmatism during SMILE is comparable to Q-value-guided FS-LASIK and superior to the conventional central tear film marking method in SMILE.
9.Efficacy of observation screen-based manual cyclotorsion compensation in the correction of with-the-rule astigmatism during SMILE
Yalin LU ; Jian XIONG ; Fei HUANG ; Chong AI ; Fu GUI
Recent Advances in Ophthalmology 2025;45(5):365-369
Objective To evaluate the efficacy of the manual cyclotorsion compensation method based on the obser-vation screen in the correction of with-the-rule astigmatism during small incision lenticule extraction(SMILE).Methods This prospective study enrolled 40 patients who underwent SMILE and another 40 patients who underwent Q-value-guided femtosecond laser-assisted laser in situ keratomileusis(FS-LASIK)at the Ophthalmology Center of the Second Affiliated Hospital of Nanchang University from April to September 2024.Through the random number method,one eye of each pa-tient who underwent SMILE was assigned to the manual cyclotorsion compensation group(the cyclotorsion group,40 eyes),while the contralateral eye was assigned to the non-cyclotorsion group(the non-cyclotorsion group,40 eyes).Meanwhile,one eye of each patient who underwent FS-LASIK was randomly selected for the FS-LASIK group(40 eyes).The age,uncorrected distance visual acuity(UDVA),spherical power,cylindrical power,spherical equivalent(SE),and corrected distance visual acuity(CDVA)were recorded before surgery and 3 months after surgery,respectively.Astigma-tism was subjected to Alpins vector analysis,and the indicators for assessing astigmatism included target-induced astigma-tism(TIA),surgically-induced astigmatism(SIA),difference vector(DV),correction index(CI),success index(IOS),angle of error(AE),and absolute value of angle of error(|AE|).Results Before surgery,there was no significant difference in age,spherical power,cylindrical power,SE,and CDVA among the cyclotorsion group,the non-cyclotorsion group,and the FS-LASIK group(all P>0.05).At 3 months after surgery,the cyclotorsion group showed better UDVA and lower cylindrical power than the non-cyclotorsion group,with statistically significant differences(both P<0.05);howev-er,there was no significant difference in CDVA,spherical power,and SE between the two groups(all P>0.05).Besides,there was no significant difference in UDVA,CDVA,or refractive parameters between the cyclotorsion and FS-LASIK groups(all P>0.05).The Alpins vector analysis of astigmatism 3 months after surgery revealed better SIA,CI,IOS,and|AE|in the cyclotorsion group compared with the non-cyclotorsion group,with statistically significant differences(all P<0.05);however,there was no significant difference in TIA,DV,and AE between the two groups(all P>0.05).No signifi-cant differences were found between the cyclotorsion and FS-LASIK groups in any astigmatism vector parameter(all P>0.05).The linear regression analysis results indicated a high linear correlation between TIA and SIA in all groups.Conclu-sion The manual cyclotorsion compensation method based on the observation screen in the correction of with-the-rule astigmatism during SMILE is comparable to Q-value-guided FS-LASIK and superior to the conventional central tear film marking method in SMILE.
10.IGF-1 Induces Osteogenic Differentiation of Rat Bone Marrow Mesenchymal Stem Cells by Promoting SOX4via the MAPK/ERK Pathway
Jingjun ZENG ; Jun DENG ; Chong HE ; Qi-an XIONG ; Xiujiang LI ; Zhiwen WANG
International Journal of Stem Cells 2024;17(4):418-426
Tissue engineering envisions functional substitute creation for damaged tissues. Insulin-like growth factor-1 (IGF-1) plays roles in bone marrow mesenchymal stem cell (BMSC) osteogenic differentiation (OD), and we investigated its specific mechanism. BMSCs were cultured and OD was induced. Surface antigens (CD105, CD90, CD44, CD45, CD34) were identified by flow cytometry. Adipogenic, chondrogenic, and osteogenic differentiation abilities of BMSCs were observed. BMSCs were cultured in osteogenic medium containing 80 ng/mL IGF-1 for 3 weeks. Alkaline phosphatase activity, calcification level, osteogenic factor (runt related protein 2 [RUNX2], osteocalcin [OCN], osterix [OSX]), total (t-) ERK1/2 and phosphorylated-(p-) ERK1/2 levels, and SRY-related high-mobility-group box 4 (SOX4) levels were assessed by alkaline phosphatase staining and Alizarin Red staining, Western blot, and reverse transcription-quantitative polymerase chain reaction. The mitogen-activated protein kinase/extracellular signal-regulated kinase (MAPK/ERK) pathway inhibitor (PD98059) was used to inhibit the MAPK/ERK pathway in IGF-1-treated BMSCs. Small interfering-SOX4 was transfected into BMSCs to down-regulate SOX4.IGF-1 increased alkaline phosphatase activity, cell calcification, and osteogenic factor (RUNX2, OCN, OSX) levels in BMSCs, indicating that IGF-1 induced rat BMSC OD. SOX4, and p-ERK1/2 and t-ERK1/2 levels were elevated in IGF-1-induced BMSCs, which were annulled by PD98059. PD98059 partly averted IGF-1-induced rat BMSC OD. SOX4 levels, alkaline phosphatase activity, cell calcification, and osteogenic factor (RUNX2, OCN, OSX) levels were reduced after SOX4 down-regulation, showing that downregulation of SOX4 averted the effect of IGF-1 on inducing rat BMSC OD. IGF-1 induced rat BMSC OD by stimulating SOX4 via the MAPK/ERK pathway.

Result Analysis
Print
Save
E-mail