1.Effectiveness analysis of Youngswick-Akin osteotomy on moderate hallux valgus combined with mild to moderate hallux rigidus.
Wenbo XU ; Lei HUANG ; Chenqin XU ; Haiqing WANG ; Yanzhao ZHU ; Haoyang REN ; Lufeng YAO
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(10):1256-1262
OBJECTIVE:
To investigate the effectiveness of Youngswick-Akin osteotomy in the treatment of moderate hallux valgus combined with mild to moderate hallux rigidus.
METHODS:
The clinical data of 43 patients with moderate hallux valgus combined with mild to moderate hallux rigidus who were admitted between August 2019 and August 2022 and met the selection criteria were retrospectively analyzed. There were 8 males and 35 females. The age ranged from 28 to 77 years, with an average age of 59.0 years. The disease duration ranged from 10 to 35 months, with an average of 20 months. The degree of hallux rigidus included 2 cases of CoughlinⅠ degree, 29 cases of Ⅱ degree, 12 cases of Ⅲ degree. The preoperative hallux valgus angle ranged from 25° to 40°, with an average of 32°. All patients were treated with Youngswick-Akin osteotomy. The first metatarsophalangeal joint space was compared before operation and at 6 months after operation. The American Orthopaedic Foot and Ankle Society (AOFAS) score and visual analogue scale (VAS) score were used to evaluate the functional recovery and pain relief of the patients before operation and at 6 and 24 months after operation. According to the severity of hallux rigidus, the patients were divided into mild group (Ⅰ, Ⅱ degree) and moderate group (Ⅲ degree) to compare the prognosis, including the changes of AOFAS score, VAS score, and the first metatarsophalangeal joint space.
RESULTS:
The operation time was 60-75 minutes (mean, 65 minutes). The intraoperative blood loss was 10-30 mL (mean, 20 mL). Two cases had superficial infection of the incision margin after operation, and healed well after dressing change and antibiotic treatment. The incisions of the other patients healed by first intention, and no medial cutaneous nerve injury of the great toe occurred. All patients were followed up 24-31 months, with an average of 25.8 months. The patient's hallux valgus deformity was corrected without recurrence; no complication such as osteomyelitis and hallux varus occurred. The AOFAS score, VAS score, and the first metatarsophalangeal joint space after operation significantly improved when compared with those before operation, the AOFAS score and VAS score at 24 months after operation further improved when compared with those at 6 months after operation, and the differences were significant ( P<0.05). The change of VAS score in mild group was significantly better than that in moderate group ( P<0.05); but there was no significant difference in the changes of AOFAS score and the first metatarsophalangeal joint space between the two groups ( P>0.05).
CONCLUSION
Youngswick-Akin osteotomy for moderate valgus deformity with mild to moderate hallux rigidus can achieve good functional recovery, pain relief, and joint space improvement.
Humans
;
Osteotomy/methods*
;
Hallux Valgus/diagnostic imaging*
;
Male
;
Female
;
Middle Aged
;
Hallux Rigidus/diagnostic imaging*
;
Retrospective Studies
;
Adult
;
Aged
;
Treatment Outcome
;
Metatarsophalangeal Joint/surgery*
2.An Atrial Fibrillation Classification Method Study Based on BP Neural Network and SVM.
Chenqin LIU ; Gaozang LIN ; Jingjing ZHOU ; Jilun YE ; Xu ZHANG
Chinese Journal of Medical Instrumentation 2023;47(3):258-263
Atrial fibrillation is a common arrhythmia, and its diagnosis is interfered by many factors. In order to achieve applicability in diagnosis and improve the level of automatic analysis of atrial fibrillation to the level of experts, the automatic detection of atrial fibrillation is very important. This study proposes an automatic detection algorithm for atrial fibrillation based on BP neural network (back propagation network) and support vector machine (SVM). The electrocardiogram (ECG) segments in the MIT-BIH atrial fibrillation database are divided into 10, 32, 64, and 128 heartbeats, respectively, and the Lorentz value, Shannon entropy, K-S test value and exponential moving average value are calculated. These four characteristic parameters are used as the input of SVM and BP neural network for classification and testing, and the label given by experts in the MIT-BIH atrial fibrillation database is used as the reference output. Among them, the use of atrial fibrillation in the MIT-BIH database, the first 18 cases of data are used as the training set, and the last 7 cases of data are used as the test set. The results show that the accuracy rate of 92% is obtained in the classification of 10 heartbeats, and the accuracy rate of 98% is obtained in the latter three categories. The sensitivity and specificity are both above 97.7%, which has certain applicability. Further validation and improvement in clinical ECG data will be done in next study.
Humans
;
Atrial Fibrillation/diagnosis*
;
Support Vector Machine
;
Heart Rate
;
Algorithms
;
Neural Networks, Computer
;
Electrocardiography
3.A Ventricular Fibrillation Recognition Method Based on Random Forest and BP Neural Network.
Chenqin LIU ; Gaozang LIN ; Jilun YE ; Xu ZHANG
Chinese Journal of Medical Instrumentation 2023;47(4):396-401
Ventricular fibrillation is the most common pathophysiological mechanism leading to cardiac arrest. If cardiac arrest can be rescued in time, the survival rate of patients can be greatly improved. Therefore, rapid and accurate identification of ventricular fibrillation is extremely important. This paper proposes an automatic detection algorithm for ventricular fibrillation based on random forest and BP (back propagation) neural network. Pass the ECG signal through a 6 s moving window, calculate 6 kinds of characteristic parameters according to the time-frequency domain information of the signal, use these 6 kinds of characteristic parameters as the input of the classifier, carry out classification and test, and give the authoritative experts in the database. A total of 44 cases of related data were used to evaluate the method. The results show that using the ten-fold cross-validation method, the accuracy of classification of ventricular fibrillation in the CU database (Creighton University Ventricular Tachyarrhythmia Database) and the AHA database (the American Heart Association Database) has reached 96.38% and 99.45%, which has certain applicability.
4.Fetal ECG Detection System Based on WiFi Data Transmission.
Gaozang LIN ; Chenqin LIU ; Zichen LIU ; Hangyu LE ; Jilun YE ; Xu ZHANG
Chinese Journal of Medical Instrumentation 2023;47(4):406-410
Fetal ECG monitoring is a routine clinical detection method that can reflect the changes of fetal heart in utero in real time. At present, most of the clinical fetal heart rate detection adopts the ultrasonic Doppler method, which is technically difficult and highly specialized in operation and expensive. This study introduces a fetal ECG detection system based on the maternal abdominal electrode method. The weak fetal ECG changes are sensed through the maternal abdominal electrode, and the mixed ECG signal is obtained through the corresponding amplification and filtering circuit. Finally, the obtained signal is passed through WiFi, transmitted to the host computer. The host computer uses the adaptive filtering algorithm to estimate the fetal ECG signal. The system has strong feasibility, low operation expertise, low cost, and is more convenient.
5.Development of Respiratory Signal Monitoring System Based on Photoplethysmography.
Chenqin LIU ; Sinian YUAN ; Gaozang LIN ; Shijie CAI ; Jilun YE ; Xu ZHANG ; Hao JIN
Chinese Journal of Medical Instrumentation 2022;46(4):368-372
Breathing is of great significance in the monitoring of patients with obstructive sleep apnea hypopnea syndrome, perioperative monitoring and intensive care. In this study, a respiratory monitoring and verification system based on optical capacitance product pulse wave (PPG) is designed, which can synchronously collect human PPG signals. Through algorithm processing, the characteristic parameters of PPG signal are calculated, and the respiratory signal and respiratory frequency can be extracted in real time. In order to verify the accuracy of extracting respiratory signal and respiratory rate by the algorithm, the system adds the nasal airflow respiratory signal acquisition module to synchronously collect the nasal airflow respiratory signal as the standard signal for comparison and verification. Finally, the root mean square error between the respiratory rate extracted by the algorithm from the pulse wave and the standard respiratory rate is only 1.05 times/min.
Algorithms
;
Electrocardiography
;
Heart Rate
;
Humans
;
Photoplethysmography
;
Respiration
;
Respiratory Rate
;
Signal Processing, Computer-Assisted
;
Sleep Apnea, Obstructive

Result Analysis