1.Comparative study on the visual quality of different types of multifocal in-traocular lenses after cataract surgery
Jiaping DENG ; Sen LIU ; Han JIANG ; Meng MA ; Chengzhang LUO ; Jun ZHENG ; Shuangle LI
Recent Advances in Ophthalmology 2025;45(12):967-973
Objective To compare and analyze the impact of intraocular higher-order aberrations and total ocular higher-order aberrations on visual quality after the implantation of different types of multifocal intraocular lenses(MIOL),in order to provide personalized MIOL selection recommendations for patients.Methods A total of 107 patients(107 eyes)with age-related cataract were selected and divided into the SBL-3,MF15,ZMB00,and Zeiss809 groups based on the type of MIOL implanted.Uncorrected distance visual acuity(UCDVA),best-corrected distance visual acuity(BCDVA),best-corrected near visual acuity(BCNVA),optical parameters and wavefront aberrations were compared 3 months postop-eratively.Results Preoperatively,there were no statistically significant differences in any optical parameters or visual acuity among the four groups(all P>0.05).At three months postoperatively,there were no significant differences in UCD-VA,BCDVA,BCNVA,corneal aberration,or intraocular spherical aberration among the four groups(all P>0.05).How-ever,significant differences were observed in the predicted visual acuity at 100%,20%,and 9%contrast(100%VA,20%VA,9%VA),streller ratio(SR),modulation transfer function cutoff frequency(MTF cutoff),intraocular coma,intraocu-lar trefoil,total higher-order aberrations,and the average modulation transfer function height values(MTF AH)of the en-tire eye across various spatial frequencies showed significant differences(all P<0.05).Pairwise comparisons showed that the ZMB00 and Zeiss809 groups had significantly better 100%VA,20%VA,9%VA,SR,MTF cutoff,and MTF AH,and sig-nificantly lower intraocular coma,intraocular trefoil,and total higher-order aberrations than the SBL-3 group(all P<0.05).The MF15 group only had significantly lower intraocular trefoil than the SBL-3 group(P<0.05).Correlation analy-sis results at 3 months postoperatively showed that in the SBL-3 and MF15 groups,UCDVA(logMAR)was positively corre-lated with the objective scattering index and negatively correlated with 100%VA,20%VA,9%VA,SR,and MTF cutoff(all P<0.05).MTF AH was negatively correlated with intraocular coma and total higher-order aberrations,and positively cor-related with intraocular spherical aberration(all P<0.05).In the ZMB00 and Zeiss809 groups,MTF AH was negatively cor-related with intraocular coma,intraocular trefoil,and total higher-order aberrations(all P<0.05),but showed no correla-tion with intraocular spherical aberration(all P>0.05).Conclusion There are no differences in UCDVA,BCDVA,or BCNVA among patients implanted with the four types of MIOLs,but differences existed in objective visual quality.The ob-jective visual quality of ZMB00 and Zeiss809 is significantly better than that of SBL-3,making them the preferred choices for patients with high-quality visual demands;SBL-3 is suitable for basic demand scenarios;MF15,which is only superior to SBL-3 in terms of intraocular trefoil,can be a compromise option for those sensitive to trefoil aberration.
2.Comparative study on the visual quality of different types of multifocal in-traocular lenses after cataract surgery
Jiaping DENG ; Sen LIU ; Han JIANG ; Meng MA ; Chengzhang LUO ; Jun ZHENG ; Shuangle LI
Recent Advances in Ophthalmology 2025;45(12):967-973
Objective To compare and analyze the impact of intraocular higher-order aberrations and total ocular higher-order aberrations on visual quality after the implantation of different types of multifocal intraocular lenses(MIOL),in order to provide personalized MIOL selection recommendations for patients.Methods A total of 107 patients(107 eyes)with age-related cataract were selected and divided into the SBL-3,MF15,ZMB00,and Zeiss809 groups based on the type of MIOL implanted.Uncorrected distance visual acuity(UCDVA),best-corrected distance visual acuity(BCDVA),best-corrected near visual acuity(BCNVA),optical parameters and wavefront aberrations were compared 3 months postop-eratively.Results Preoperatively,there were no statistically significant differences in any optical parameters or visual acuity among the four groups(all P>0.05).At three months postoperatively,there were no significant differences in UCD-VA,BCDVA,BCNVA,corneal aberration,or intraocular spherical aberration among the four groups(all P>0.05).How-ever,significant differences were observed in the predicted visual acuity at 100%,20%,and 9%contrast(100%VA,20%VA,9%VA),streller ratio(SR),modulation transfer function cutoff frequency(MTF cutoff),intraocular coma,intraocu-lar trefoil,total higher-order aberrations,and the average modulation transfer function height values(MTF AH)of the en-tire eye across various spatial frequencies showed significant differences(all P<0.05).Pairwise comparisons showed that the ZMB00 and Zeiss809 groups had significantly better 100%VA,20%VA,9%VA,SR,MTF cutoff,and MTF AH,and sig-nificantly lower intraocular coma,intraocular trefoil,and total higher-order aberrations than the SBL-3 group(all P<0.05).The MF15 group only had significantly lower intraocular trefoil than the SBL-3 group(P<0.05).Correlation analy-sis results at 3 months postoperatively showed that in the SBL-3 and MF15 groups,UCDVA(logMAR)was positively corre-lated with the objective scattering index and negatively correlated with 100%VA,20%VA,9%VA,SR,and MTF cutoff(all P<0.05).MTF AH was negatively correlated with intraocular coma and total higher-order aberrations,and positively cor-related with intraocular spherical aberration(all P<0.05).In the ZMB00 and Zeiss809 groups,MTF AH was negatively cor-related with intraocular coma,intraocular trefoil,and total higher-order aberrations(all P<0.05),but showed no correla-tion with intraocular spherical aberration(all P>0.05).Conclusion There are no differences in UCDVA,BCDVA,or BCNVA among patients implanted with the four types of MIOLs,but differences existed in objective visual quality.The ob-jective visual quality of ZMB00 and Zeiss809 is significantly better than that of SBL-3,making them the preferred choices for patients with high-quality visual demands;SBL-3 is suitable for basic demand scenarios;MF15,which is only superior to SBL-3 in terms of intraocular trefoil,can be a compromise option for those sensitive to trefoil aberration.
3.Effects of transcutaneous electrical acupoint stimulation assisting sodium nitroprusside controlled hypotension on Glu,ATⅡ and SOD
Zhenwei LI ; Chengzhang ZHANG ; Furong LUO ; Xiaojian CAI ; Shuqi ZHONG ; Biao HUANG
Chongqing Medicine 2015;(10):1337-1339
Objective To observe the effects of transdermal acupoint electric stimulation(TEAS)assisting sodium nitroprus-side induced controlled hypotension on serum glucose (Glu),angiotensin Ⅱ (ATⅡ)and superoxide dismutase (SOD),and to inves-tigate the protective effect of TEAS under controlled hypotension anesthesia.Methods 60 cases undergoing elective endoscopy si-nus surgery by adopting sodium nitroprusside induced controlled hypotension under general anaesthesia maintained the mean arterial pressure(MAP)in 50-60 mm Hg and were randomly and equally divided into two groups.The group Ⅰ conducted TEAS,while the group Ⅱ did not conduct TEAS.The controlled hypotension time and surgery time were recorded in the two groups;Glu and ATⅡ values were detected before anesthesia (T0 ),30 min after hypotension (T1 ),hypotension stopping(T2 );SOD was detected at T0 ,T2 ,30 min after hypotension(T3 ).Results The operation time and controlled hypotension continuous time had no statistically significant difference between the two groups(P >0.05).The Glu value in the group Ⅰ had no statistically significant difference a-mong the 3 time points,while which at T1 ,T2 was higher than that at T0 in the group Ⅱ(P <0.05),and which at T1 ,T2 in the group Ⅱ was higher than that in the group Ⅰ (P <0.05);the ATⅡ value at T1 was higher than that at T0 in the group Ⅰ (P <0.05),while which at T1 ,T2 was higher than that at T0 in the group Ⅱ(P >0.05),which at T1 ,T2 in the group Ⅱwas higher than that in the group Ⅰ (P <0.05);the SOD value at T2 was lower than that at T0 in the group Ⅰ,which at T2 ,T3 in the group Ⅱwas lower than that in the group Ⅰ(P <0.05).Conclusion TEAS assisting sodium nitroprusside controlled hypotension can better in-hibit the stress response.

Result Analysis
Print
Save
E-mail