1.Equivalence of SYN008 versus omalizumab in patients with refractory chronic spontaneous urticaria: A multicenter, randomized, double-blind, parallel-group, active-controlled phase III study.
Jingyi LI ; Yunsheng LIANG ; Wenli FENG ; Liehua DENG ; Hong FANG ; Chao JI ; Youkun LIN ; Furen ZHANG ; Rushan XIA ; Chunlei ZHANG ; Shuping GUO ; Mao LIN ; Yanling LI ; Shoumin ZHANG ; Xiaojing KANG ; Liuqing CHEN ; Zhiqiang SONG ; Xu YAO ; Chengxin LI ; Xiuping HAN ; Guoxiang GUO ; Qing GUO ; Xinsuo DUAN ; Jie LI ; Juan SU ; Shanshan LI ; Qing SUN ; Juan TAO ; Yangfeng DING ; Danqi DENG ; Fuqiu LI ; Haiyun SUO ; Shunquan WU ; Jingbo QIU ; Hongmei LUO ; Linfeng LI ; Ruoyu LI
Chinese Medical Journal 2025;138(16):2040-2042
2.Parameter optimization for ultra-low dose computed tomography of the chest using spectral purification technology
Chengxin KANG ; Wangjia LI ; Binjie FU ; Zhigang CHU ; Fajin LYU
Chinese Journal of Radiological Medicine and Protection 2025;45(4):356-361
Objective:To optimize the scan parameters for ultra-low dose computed tomography (ULDCT) of the chest using spectral purification technology, and assess the feasibility of maintaining image quality while reducing radiation dosage.Methods:An anthropomorphic chest phantom embedded with simulated pulmonary nodules was utilized for low-dose computed tomography(LDCT) and ULDCT scans. LDCT was conducted using a reference tube current of 25 mAs and a pitch of 1.0. ULDCT incorporating spectral purification technology was conducted using four reference tube currents, i. e., 50, 100, 150, and 200 mAs (labeled ULDCT1-4), and a pitch of 1.5. Other parameters were consistent. The volume CT dose index and the dose-length product were extracted from the dose reports, and then the effective doses were calculated. The objective image quality was assessed using metrics including image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). The subjective image quality of ULDCT images was assessed on a four-point scale with LDCT images as reference.Results:The ULDCT4 at a reference tube current of 200 mAs showed a lower effective dose compared to LDCT ( t = -17.30, P < 0.001). The objective image quality assessments indicated that noise levels in four ULDCT groups were higher than those in LDCT ( t = 21.96, 10.56, 3.15, 3.14, P < 0.05). Notably, the SNR and CNR for the aortic arch were higher in ULDCT4 compared to LDCT ( t = 3.55, 71.96, P < 0.05). The SNR of pulmonary nodules in ULDCT4 was comparable to that in LDCT ( P > 0.05), but the CNR was higher ( t = 0.79, P < 0.001). Subjective image quality assessments reveal that the image quality of ULDCT4 was higher than that of LDCT, with scores of 3.80±0.46 for noise, 3.70±0.46 for contrast and sharpness, and 3.37±0.66 for pulmonary nodules. Conclusions:ULDCT (200 mAs) using spectral purification technology can yield higher image quality than LDCT while substantially reducing the radiation dose, thus demonstrating substantial clinical potential and the promise of replacing LDCT in early lung cancer screening.
3.A review of intelligent psychological assessment based on interactive environment
Kaiqi HUANG ; Yaxuan KANG ; Chengxin YAN ; Shiyu HU ; Wenbin GAO ; Ligang WANG ; Ting TAO ; Yangruiyu ZENG
Chinese Mental Health Journal 2025;39(4):337-343
Game-based psychological assessment utilizes game mechanisms and elements to enhance partic-ipants'motivation and improve measurement accuracy,but similar to traditional methods,it mainly focuses on static results.By integrating game-based psychological assessment with artificial intelligence technology,this paper propo-ses the paradigm of intelligent psychological assessment based on interactive environment.With analyzing dynamic process data within the game,this paradigm can accurately depict the participants'actions and results in the interac-tive context,more effectively representing individual psychological states and behavioral characteristics.This new paradigm demonstrates advancements and significant potential for development in terms of demand,data collection,and analysis techniques.
4.Parameter optimization for ultra-low dose computed tomography of the chest using spectral purification technology
Chengxin KANG ; Wangjia LI ; Binjie FU ; Zhigang CHU ; Fajin LYU
Chinese Journal of Radiological Medicine and Protection 2025;45(4):356-361
Objective:To optimize the scan parameters for ultra-low dose computed tomography (ULDCT) of the chest using spectral purification technology, and assess the feasibility of maintaining image quality while reducing radiation dosage.Methods:An anthropomorphic chest phantom embedded with simulated pulmonary nodules was utilized for low-dose computed tomography(LDCT) and ULDCT scans. LDCT was conducted using a reference tube current of 25 mAs and a pitch of 1.0. ULDCT incorporating spectral purification technology was conducted using four reference tube currents, i. e., 50, 100, 150, and 200 mAs (labeled ULDCT1-4), and a pitch of 1.5. Other parameters were consistent. The volume CT dose index and the dose-length product were extracted from the dose reports, and then the effective doses were calculated. The objective image quality was assessed using metrics including image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). The subjective image quality of ULDCT images was assessed on a four-point scale with LDCT images as reference.Results:The ULDCT4 at a reference tube current of 200 mAs showed a lower effective dose compared to LDCT ( t = -17.30, P < 0.001). The objective image quality assessments indicated that noise levels in four ULDCT groups were higher than those in LDCT ( t = 21.96, 10.56, 3.15, 3.14, P < 0.05). Notably, the SNR and CNR for the aortic arch were higher in ULDCT4 compared to LDCT ( t = 3.55, 71.96, P < 0.05). The SNR of pulmonary nodules in ULDCT4 was comparable to that in LDCT ( P > 0.05), but the CNR was higher ( t = 0.79, P < 0.001). Subjective image quality assessments reveal that the image quality of ULDCT4 was higher than that of LDCT, with scores of 3.80±0.46 for noise, 3.70±0.46 for contrast and sharpness, and 3.37±0.66 for pulmonary nodules. Conclusions:ULDCT (200 mAs) using spectral purification technology can yield higher image quality than LDCT while substantially reducing the radiation dose, thus demonstrating substantial clinical potential and the promise of replacing LDCT in early lung cancer screening.
5.A review of intelligent psychological assessment based on interactive environment
Kaiqi HUANG ; Yaxuan KANG ; Chengxin YAN ; Shiyu HU ; Wenbin GAO ; Ligang WANG ; Ting TAO ; Yangruiyu ZENG
Chinese Mental Health Journal 2025;39(4):337-343
Game-based psychological assessment utilizes game mechanisms and elements to enhance partic-ipants'motivation and improve measurement accuracy,but similar to traditional methods,it mainly focuses on static results.By integrating game-based psychological assessment with artificial intelligence technology,this paper propo-ses the paradigm of intelligent psychological assessment based on interactive environment.With analyzing dynamic process data within the game,this paradigm can accurately depict the participants'actions and results in the interac-tive context,more effectively representing individual psychological states and behavioral characteristics.This new paradigm demonstrates advancements and significant potential for development in terms of demand,data collection,and analysis techniques.

Result Analysis
Print
Save
E-mail