1.Treatment of multi-finger degloved defects with 7 free flaps from a leg: a case report
Chengwei GE ; You LI ; Guodong JIANG ; Linfeng TANG ; Junnan CHENG ; Song YUAN ; Jihui JU
Chinese Journal of Microsurgery 2025;48(4):469-472
In January 2023, a patient with soft tissue degloving defect of right index, middle, ring and little fingers was treated in the Department of Hand Surgery, Suzhou Ruihua Orthopaedic Hospital. Seven free flaps from a leg were harvested to reconstruct the defected wound of fingers in primary surgery. Flap thinning and plastic surgery were performed in stage-II surgery. Over the 22 months of postoperative follow-up, the flaps in right index, middle, ring and little fingers survived well with the colour and texture close to proximal skin. There was no obvious swelling of the flaps and sensation of the flaps recovered to S 3. The donor sites healed well and the donor leg walked normally.
2.Treatment of multi-finger degloved defects with 7 free flaps from a leg: a case report
Chengwei GE ; You LI ; Guodong JIANG ; Linfeng TANG ; Junnan CHENG ; Song YUAN ; Jihui JU
Chinese Journal of Microsurgery 2025;48(4):469-472
In January 2023, a patient with soft tissue degloving defect of right index, middle, ring and little fingers was treated in the Department of Hand Surgery, Suzhou Ruihua Orthopaedic Hospital. Seven free flaps from a leg were harvested to reconstruct the defected wound of fingers in primary surgery. Flap thinning and plastic surgery were performed in stage-II surgery. Over the 22 months of postoperative follow-up, the flaps in right index, middle, ring and little fingers survived well with the colour and texture close to proximal skin. There was no obvious swelling of the flaps and sensation of the flaps recovered to S 3. The donor sites healed well and the donor leg walked normally.
3.Clinical effects of free bilateral turbocharged anterolateral thigh flaps in tandem in repairing extensive wounds in the foot and ankle
Liang YANG ; Rong ZHOU ; Jihui JU ; Zefeng NIU ; Zhongzheng LIU ; Liping GUO ; Zhijin LIU ; Qianheng JIN ; Chengwei GE ; Guiyang WANG ; Lin YANG ; Junnan CHENG
Chinese Journal of Burns 2025;41(1):61-69
Objective:To explore the clinical effects of free bilateral turbocharged anterolateral thigh flaps in tandem in repairing extensive wounds in the foot and ankle.Methods:The study was a retrospective observational study. From April 2020 to June 2023, 12 patients with extensive wounds in the foot and ankle who met the inclusion criteria were admitted to the Department of Wound Repair Surgery of Suzhou Ruihua Orthopedic Hospital, including 8 males and 4 females, aged 21 to 65 years. The wound area after debridement ranged from 27 cm×14 cm to 37 cm×20 cm. The bilateral perforator flaps pedicled with either oblique or descending branches of the lateral circumflex femoral artery were designed and harvested based on the size and shape of the wounds. The individual flap incision area ranged from 16 cm×9 cm to 34 cm×12 cm. The non-homologous perforator of the flap on the one side was turbocharged by anastomosing it with the gross muscular branch or main vessel of the oblique or descending branch of the lateral circumflex femoral artery from the flap. Subsequently, the proximal end of the oblique or descending branch of the lateral circumflex femoral artery and its accompanying vein from the flap on the one side were connected end-to-end with either the anterior tibial artery and vein, posterior tibial artery and vein, or dorsal foot artery and vein in the recipient area, the distal end of the oblique or descending branch of the lateral circumflex femoral artery and its accompanying vein from the flap on the one side were anastomosed end-to-end with a source vessel originating from flap on the other side. The wounds in the flap donor areas were sutured directly. The number and source of perforators carried by the flaps and the duration of the flap repair surgery were recorded. The survival of the flap, the occurrence of vascular crisis, and the wound healing at both donor and recipient areas were observed after surgery. The flap condition, appearance and function of the affected limb were observed during follow-up. At the last follow-up, the sensory function of the flap was assessed using the British Medical Research Council's sensory rating standard, the foot and ankle function of the affected limb was evaluated according to the American Orthopedic Foot and Ankle Society scoring standard.Results:A total 24 flaps were successfully harvested, carrying 60 perforators, including 34 perforators from the oblique branch of the lateral circumflex femoral artery, 24 perforators from the descending branch of the lateral circumflex femoral artery, one perforator from the transverse branch of the lateral circumflex femoral artery, and one perforator from the direct branch of the femoral artery. The duration of the flap repair surgery ranged from 4.2 to 9.0 hours. The flaps of 12 patients exhibited complete survival after surgery. A total of two flaps of two patients experienced venous crisis after surgery but survived through emergency exploration. One patient encountered undesirable wound healing at the donor area of flap on the one side after surgery, which healed after dressing change, debridement, and suturing. The remaining patients' donor area wounds healed. Two patients displayed impaired wound healing in the recipient area, which improved after dressing change and resection of residual sequestrum, and the wounds in the recipient area of other patients healed successfully. During the follow-up of 4-26 months, the flaps demonstrated favorable color and texture, slight edematous appearance, and partial sensory recovery, as well as good aesthetic and functional restoration of the affected limbs. At the last follow-up, the sensory function of the flap was assessed as grade S2 in 9 cases and grade S3 in 3 cases; the foot and ankle function of the affected limb was evaluated as excellent in two cases, good in 9 cases, and fair in one case.Conclusions:The bilateral turbocharged anterolateral thigh flaps have numerous sources of perforators. By implementing supercharging of non-homologous perforators within the flap, the vascular supply to the flap is turbocharged, thereby mitigating the risk of extensive flap necrosis. The flap is an effective approach for repairing extensive wounds in the foot and ankle, resulting in improved function of the affected limb after repair.
4.Reconstruction of Gustilo ⅢC foot and ankle injury in emergency surgery with Flow-through anterolateral thigh myocutaneous flap combined with grafting of contralateral great saphenous vein
Liang YANG ; Rong ZHOU ; Jihui JU ; Zefeng NIU ; Zhongzheng LIU ; Liping GUO ; Zhijing LIU ; Qianheng JIN ; Chengwei GE
Chinese Journal of Microsurgery 2025;48(2):149-155
Objective:To investigate the clinical efficacy of combination of a Flow-through anterolateral thigh myocutaneous flap with a contralateral great saphenous vein grafting in reconstruction of Gustilo ⅢC foot and ankle injury in emergency surgery.Methods:This retrospective study analysed the clinical data of 9 patients who were admitted in the Department of Wound Repair Surgery, Suzhou Ruihua Orthopaedic Hospital between September 2021 and October 2023. All patients were diagnosed with Gustilo ⅢC foot and ankle injury and met the predefined inclusion criteria. The average age of the patients was 45 (26-64) years. The mean of Mangled Extremity Severity Score (MESS) was 8.2 points, with a range from 5 to 10 points. The wound area after debridement ranged from 15.5 cm×6.0 cm to 24.5 cm×12.5 cm, with the vascular occlusion or defect at 4.0-20.0 (mean, 6.3) cm in length. The size of the flap was 16.5 cm×7.0 cm-25.5 cm×13.5 cm. During surgery, segments of the great saphenous vein were excised in the length of 5.0-21.0 cm, at an approximately 6.5 cm in length. The Flow-through anterolateral thigh myocutaneous flap was employed to reconstruct the soft tissue defect and to establish vascular connections between the anterior or posterior tibial arteries and veins, with the vessels carried by the flap. Additionally, the contralateral great saphenous vein was taken to bridge the posterior or anterior tibial arteries and veins. Follow-ups were carried out by outpatient visits, telephone calls and WeChat interviews. The flap viability, limb blood circulation, wound healing at both donor and recipient sites, as well as functional recovery of the affected limbs was observed. Sensation recovery of the flap was assessed according to the rating standard established by the British Medical Research Council (BMRC) , while the function recovery of foot and ankle was evaluated using the American Orthopaedic Foot and Ankle Society (AOFAS) scale.Results:All flaps successfully survived without vascular complication. Eight affected limbs were effectively cured, while a calf that had an infection and necrosis of a long segment of tibia and fibula was amputated below-the-knee in the stage-II surgery. One of the donor sites of flap was covered with a medium-thickness skin graft from lower abdomen due to the large size of the flap, while the other donor sites were directly sutured and healed at first intention. One patient developed postoperative bone infection, which was successfully treated through re-debridement and antibiotic bone cement filling. Another patient experienced partial necrosis at the distal hallux due to a prolonged limb ischemia, and a stump repair surgery was performed. All patients were entered into the postoperative follow-up for 15.3 (6-24) months. At the final follow-up visit, satisfactory colour and texture were observed on all flaps, although minor oedema was present. Donor sites healed well and the donor limb function was not affected. Sensory evaluation rated S 2 in 5 flaps and S 3 in 3 flaps according to BMRC. Functional assessment of foot and ankle of the affected limb yielded excellent in 2 patients, good in 5 patients and fair in 1 patient according to AOFAS. Conclusion:Flow-through anterolateral thigh myocutaneous flap combined with a contralateral great saphenous vein grafting enables one-stage reconstruction for soft tissue defect and blood circulation of the affected limb. It is a good method in the treatment of Gustilo ⅢC foot and ankle injury in emergency surgery.
5.Reconstruction of distal thumb avulsion injury by a tiled flap combined with a hallux nail flap and a lateral flap of the second toe: a case report
Shuai DONG ; Jihui JU ; Kai WANG ; Shi WANG ; Chengwei GE ; Linfeng TANG ; Ruixing HOU
Chinese Journal of Microsurgery 2025;48(5):577-579
In January 2021, a young male patient was admitted to the Department of Hand Surgery, Suzhou Ruihua Orthopeadic Hospital for a soft tissue degloving defect of distal segment of right thumb caused by machine compression. The thumb defect was reconstructed using a tiled flap with a right hallux nail flap and a lateral flap of left second toe. Donor site of the hallux nail flap was reconstructed by a lateral flap of right second toe, while the donor site of lateral flap of left second toe was covered by a skin graft of abdomen. At 1-year follow-up, the reconstructed nail was found excellent according to the established criteria. Two-point discrimination (TPD) was measured at 5 mm, and the affected thumb exhibited satisfactory flexion and extension and functions of thumb-to-palm and thumb-to-fingers oppositions. Donor sites in both feet achieved favorable appearance and function, with a Maryland foot score of 96. Only a linear scar was in abdominal donor site.
6.Reconstruction of Gustilo ⅢC foot and ankle injury in emergency surgery with Flow-through anterolateral thigh myocutaneous flap combined with grafting of contralateral great saphenous vein
Liang YANG ; Rong ZHOU ; Jihui JU ; Zefeng NIU ; Zhongzheng LIU ; Liping GUO ; Zhijing LIU ; Qianheng JIN ; Chengwei GE
Chinese Journal of Microsurgery 2025;48(2):149-155
Objective:To investigate the clinical efficacy of combination of a Flow-through anterolateral thigh myocutaneous flap with a contralateral great saphenous vein grafting in reconstruction of Gustilo ⅢC foot and ankle injury in emergency surgery.Methods:This retrospective study analysed the clinical data of 9 patients who were admitted in the Department of Wound Repair Surgery, Suzhou Ruihua Orthopaedic Hospital between September 2021 and October 2023. All patients were diagnosed with Gustilo ⅢC foot and ankle injury and met the predefined inclusion criteria. The average age of the patients was 45 (26-64) years. The mean of Mangled Extremity Severity Score (MESS) was 8.2 points, with a range from 5 to 10 points. The wound area after debridement ranged from 15.5 cm×6.0 cm to 24.5 cm×12.5 cm, with the vascular occlusion or defect at 4.0-20.0 (mean, 6.3) cm in length. The size of the flap was 16.5 cm×7.0 cm-25.5 cm×13.5 cm. During surgery, segments of the great saphenous vein were excised in the length of 5.0-21.0 cm, at an approximately 6.5 cm in length. The Flow-through anterolateral thigh myocutaneous flap was employed to reconstruct the soft tissue defect and to establish vascular connections between the anterior or posterior tibial arteries and veins, with the vessels carried by the flap. Additionally, the contralateral great saphenous vein was taken to bridge the posterior or anterior tibial arteries and veins. Follow-ups were carried out by outpatient visits, telephone calls and WeChat interviews. The flap viability, limb blood circulation, wound healing at both donor and recipient sites, as well as functional recovery of the affected limbs was observed. Sensation recovery of the flap was assessed according to the rating standard established by the British Medical Research Council (BMRC) , while the function recovery of foot and ankle was evaluated using the American Orthopaedic Foot and Ankle Society (AOFAS) scale.Results:All flaps successfully survived without vascular complication. Eight affected limbs were effectively cured, while a calf that had an infection and necrosis of a long segment of tibia and fibula was amputated below-the-knee in the stage-II surgery. One of the donor sites of flap was covered with a medium-thickness skin graft from lower abdomen due to the large size of the flap, while the other donor sites were directly sutured and healed at first intention. One patient developed postoperative bone infection, which was successfully treated through re-debridement and antibiotic bone cement filling. Another patient experienced partial necrosis at the distal hallux due to a prolonged limb ischemia, and a stump repair surgery was performed. All patients were entered into the postoperative follow-up for 15.3 (6-24) months. At the final follow-up visit, satisfactory colour and texture were observed on all flaps, although minor oedema was present. Donor sites healed well and the donor limb function was not affected. Sensory evaluation rated S 2 in 5 flaps and S 3 in 3 flaps according to BMRC. Functional assessment of foot and ankle of the affected limb yielded excellent in 2 patients, good in 5 patients and fair in 1 patient according to AOFAS. Conclusion:Flow-through anterolateral thigh myocutaneous flap combined with a contralateral great saphenous vein grafting enables one-stage reconstruction for soft tissue defect and blood circulation of the affected limb. It is a good method in the treatment of Gustilo ⅢC foot and ankle injury in emergency surgery.
7.Reconstruction of distal thumb avulsion injury by a tiled flap combined with a hallux nail flap and a lateral flap of the second toe: a case report
Shuai DONG ; Jihui JU ; Kai WANG ; Shi WANG ; Chengwei GE ; Linfeng TANG ; Ruixing HOU
Chinese Journal of Microsurgery 2025;48(5):577-579
In January 2021, a young male patient was admitted to the Department of Hand Surgery, Suzhou Ruihua Orthopeadic Hospital for a soft tissue degloving defect of distal segment of right thumb caused by machine compression. The thumb defect was reconstructed using a tiled flap with a right hallux nail flap and a lateral flap of left second toe. Donor site of the hallux nail flap was reconstructed by a lateral flap of right second toe, while the donor site of lateral flap of left second toe was covered by a skin graft of abdomen. At 1-year follow-up, the reconstructed nail was found excellent according to the established criteria. Two-point discrimination (TPD) was measured at 5 mm, and the affected thumb exhibited satisfactory flexion and extension and functions of thumb-to-palm and thumb-to-fingers oppositions. Donor sites in both feet achieved favorable appearance and function, with a Maryland foot score of 96. Only a linear scar was in abdominal donor site.
8.Clinical effects of free bilateral turbocharged anterolateral thigh flaps in tandem in repairing extensive wounds in the foot and ankle
Liang YANG ; Rong ZHOU ; Jihui JU ; Zefeng NIU ; Zhongzheng LIU ; Liping GUO ; Zhijin LIU ; Qianheng JIN ; Chengwei GE ; Guiyang WANG ; Lin YANG ; Junnan CHENG
Chinese Journal of Burns 2025;41(1):61-69
Objective:To explore the clinical effects of free bilateral turbocharged anterolateral thigh flaps in tandem in repairing extensive wounds in the foot and ankle.Methods:The study was a retrospective observational study. From April 2020 to June 2023, 12 patients with extensive wounds in the foot and ankle who met the inclusion criteria were admitted to the Department of Wound Repair Surgery of Suzhou Ruihua Orthopedic Hospital, including 8 males and 4 females, aged 21 to 65 years. The wound area after debridement ranged from 27 cm×14 cm to 37 cm×20 cm. The bilateral perforator flaps pedicled with either oblique or descending branches of the lateral circumflex femoral artery were designed and harvested based on the size and shape of the wounds. The individual flap incision area ranged from 16 cm×9 cm to 34 cm×12 cm. The non-homologous perforator of the flap on the one side was turbocharged by anastomosing it with the gross muscular branch or main vessel of the oblique or descending branch of the lateral circumflex femoral artery from the flap. Subsequently, the proximal end of the oblique or descending branch of the lateral circumflex femoral artery and its accompanying vein from the flap on the one side were connected end-to-end with either the anterior tibial artery and vein, posterior tibial artery and vein, or dorsal foot artery and vein in the recipient area, the distal end of the oblique or descending branch of the lateral circumflex femoral artery and its accompanying vein from the flap on the one side were anastomosed end-to-end with a source vessel originating from flap on the other side. The wounds in the flap donor areas were sutured directly. The number and source of perforators carried by the flaps and the duration of the flap repair surgery were recorded. The survival of the flap, the occurrence of vascular crisis, and the wound healing at both donor and recipient areas were observed after surgery. The flap condition, appearance and function of the affected limb were observed during follow-up. At the last follow-up, the sensory function of the flap was assessed using the British Medical Research Council's sensory rating standard, the foot and ankle function of the affected limb was evaluated according to the American Orthopedic Foot and Ankle Society scoring standard.Results:A total 24 flaps were successfully harvested, carrying 60 perforators, including 34 perforators from the oblique branch of the lateral circumflex femoral artery, 24 perforators from the descending branch of the lateral circumflex femoral artery, one perforator from the transverse branch of the lateral circumflex femoral artery, and one perforator from the direct branch of the femoral artery. The duration of the flap repair surgery ranged from 4.2 to 9.0 hours. The flaps of 12 patients exhibited complete survival after surgery. A total of two flaps of two patients experienced venous crisis after surgery but survived through emergency exploration. One patient encountered undesirable wound healing at the donor area of flap on the one side after surgery, which healed after dressing change, debridement, and suturing. The remaining patients' donor area wounds healed. Two patients displayed impaired wound healing in the recipient area, which improved after dressing change and resection of residual sequestrum, and the wounds in the recipient area of other patients healed successfully. During the follow-up of 4-26 months, the flaps demonstrated favorable color and texture, slight edematous appearance, and partial sensory recovery, as well as good aesthetic and functional restoration of the affected limbs. At the last follow-up, the sensory function of the flap was assessed as grade S2 in 9 cases and grade S3 in 3 cases; the foot and ankle function of the affected limb was evaluated as excellent in two cases, good in 9 cases, and fair in one case.Conclusions:The bilateral turbocharged anterolateral thigh flaps have numerous sources of perforators. By implementing supercharging of non-homologous perforators within the flap, the vascular supply to the flap is turbocharged, thereby mitigating the risk of extensive flap necrosis. The flap is an effective approach for repairing extensive wounds in the foot and ankle, resulting in improved function of the affected limb after repair.
9.Design of anterolateral thigh perforator flap aided by three-dimensional printing technique for repairing irregular extremity wounds
Chengwei GE ; Guodong JIANG ; Kai WANG ; Zhigang CHE ; Junnan CHENG ; Zhicheng TENG ; Song YUAN ; Jihui JU
Chinese Journal of Plastic Surgery 2024;40(9):946-953
Objective:To investigate the clinical effect of three-dimensional(3D) flap model accurately designed before the operation in repairing irregular wounds of limbs with anterolateral thigh(ALT) perforator flap.Methods:The data of patients with ALT flaps designed with 3D printing technology to repair irregular soft tissue defects of limbs in Suzhou Ruihua Orthopedic Hospital from January to October 2022 were retrospectively analyzed. After the wound was scanned by 3D scanner before surgery, the wound model was printed. The ALT flap was precisely designed and harvested for covering the wound according to the body surface projection of the perforator vessel in the anterolateral femoral region located by color Doppler ultrasound before surgery. The survival of the flap, the healing of the donor and recipient sites and the occurrence of complications were observed and followed up after the operation. The effect of wound repair was evaluated by the comprehensive efficacy evaluation scale of the skin flap. The total score was 100 points, which was divided into excellent (90-100 points), good (75-89 points), fair (60-74 points) and poor (< 60 points).Results:A total of 34 patients were enrolled, including 26 males and 8 females, aged 18-75 years, with an average age of 45.5 years. Injury sites: wrist in 17 cases, foot in 10 cases, ankle in 7 cases. The operation time was 2.0-4.5 h (mean 3.3 h), and all donor sites were sutured directly. Vascular crisis occurred in 2 cases after skin flap transplantation. After surgical exploration, the transplanted skin flap survived, and the other skin flaps survived successfully. All 34 patients were followed up for 6 to 10 months, with an average of 8 months. All the donor sites of the skin flap healed primarily, and the wound healing time of the recipient site was 10-44 days, with an average of 20 days. At the last follow-up, the skin flap was good in color and texture, and the sensation returned to S1 and S2 grades. There were scars left in the donor site, no cicatricial contracture, pain and other discomfort, and no other serious complications. The results of flap evaluation were 80-91 points, with an average of 86 points. Among them, 25 cases were excellent, 6 cases were good, 3 cases were fair, and the excellent and good rate was 91%(31/34).Conclusion:The application of 3D printing technology assisted the design of ALT perforator flap to repair irregular wounds of limbs can significantly reduce the intraoperative design time of the flap, which is in line with the concept of precise design and incision of the flap, and has good clinical effect, and can effectively reduce the trauma and complications of the donor site.
10.Design of anterolateral thigh perforator flap aided by three-dimensional printing technique for repairing irregular extremity wounds
Chengwei GE ; Guodong JIANG ; Kai WANG ; Zhigang CHE ; Junnan CHENG ; Zhicheng TENG ; Song YUAN ; Jihui JU
Chinese Journal of Plastic Surgery 2024;40(9):946-953
Objective:To investigate the clinical effect of three-dimensional(3D) flap model accurately designed before the operation in repairing irregular wounds of limbs with anterolateral thigh(ALT) perforator flap.Methods:The data of patients with ALT flaps designed with 3D printing technology to repair irregular soft tissue defects of limbs in Suzhou Ruihua Orthopedic Hospital from January to October 2022 were retrospectively analyzed. After the wound was scanned by 3D scanner before surgery, the wound model was printed. The ALT flap was precisely designed and harvested for covering the wound according to the body surface projection of the perforator vessel in the anterolateral femoral region located by color Doppler ultrasound before surgery. The survival of the flap, the healing of the donor and recipient sites and the occurrence of complications were observed and followed up after the operation. The effect of wound repair was evaluated by the comprehensive efficacy evaluation scale of the skin flap. The total score was 100 points, which was divided into excellent (90-100 points), good (75-89 points), fair (60-74 points) and poor (< 60 points).Results:A total of 34 patients were enrolled, including 26 males and 8 females, aged 18-75 years, with an average age of 45.5 years. Injury sites: wrist in 17 cases, foot in 10 cases, ankle in 7 cases. The operation time was 2.0-4.5 h (mean 3.3 h), and all donor sites were sutured directly. Vascular crisis occurred in 2 cases after skin flap transplantation. After surgical exploration, the transplanted skin flap survived, and the other skin flaps survived successfully. All 34 patients were followed up for 6 to 10 months, with an average of 8 months. All the donor sites of the skin flap healed primarily, and the wound healing time of the recipient site was 10-44 days, with an average of 20 days. At the last follow-up, the skin flap was good in color and texture, and the sensation returned to S1 and S2 grades. There were scars left in the donor site, no cicatricial contracture, pain and other discomfort, and no other serious complications. The results of flap evaluation were 80-91 points, with an average of 86 points. Among them, 25 cases were excellent, 6 cases were good, 3 cases were fair, and the excellent and good rate was 91%(31/34).Conclusion:The application of 3D printing technology assisted the design of ALT perforator flap to repair irregular wounds of limbs can significantly reduce the intraoperative design time of the flap, which is in line with the concept of precise design and incision of the flap, and has good clinical effect, and can effectively reduce the trauma and complications of the donor site.

Result Analysis
Print
Save
E-mail