1.Application value of auto-prescription technique combined with iterative reconstruction algorithm in low-dose CT pulmonary angiography
Changyu DU ; Yijun LIU ; Wei WEI ; Mengting HU ; Jingyi ZHANG ; Qiye CHENG ; Jian HE ; Anliang CHEN
Chinese Journal of Radiological Medicine and Protection 2025;45(7):685-691
Objective:To explore the application value of the double-low technique of auto-prescription technique combined with iterative reconstruction algorithm in CT pulmonary angiography (CTPA).Methods:A total of 86 patients who were clinically suspected of having pulmonary embolism and underwent CTPA examination in the First Affiliated Hospital of Dalian Medical University were prospectively collected and randomly assigned to a control group ( n = 45) and an observation group ( n = 41) according to the random number table method. In the control group, a tube voltage of 120 kVp was used with a standard iodine contrast agent dose of 60 ml, and images were reconstructed using the 40% adaptive statistical iterative reconstruction algorithm (ASIR-V). In the observation group, the tube voltage was set by auto-prescription technique, and 0.4 ml/kg of personalized low iodine contrast agent was used. Images were reconstructed with 40%, 60%, and 80% ASIR-V, respectively, and designated as observation 1, observation 2, and observation 3 respectively. The volume CT dose index (CTDI vol), dose-length product (DLP), and effective dose ( E) were recorded and compared among the four groups. The CT values and standard deviation (SD) of the main pulmonary artery, left and right pulmonary arteries, as well as the left and right pulmonary lobe arteries were measured, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of these arteries were calculated. Additionally, the SD value at the contrast medium concentration in the superior vena cava was measured, and the artifact index (AI) was subsequently calculated. Two observers independently assessed the visibility of the pulmonary arteries, image noise, and sclerosis artifacts in the superior vena cava using a blinded method. Results:The E in the observation group was 3.28 (2.08, 3.93) mSv, which was significantly lower than that in the control group [5.03 (4.86, 5.20)] mSv, and the difference was statistically significant ( Z = 174.00, P < 0.05). The contrast agent dosage in the observation group was 28 (25, 30) ml, which was lower than that in the control group (60 ml), and the difference was statistically significant ( Z = 0, P < 0.05). The CT values for the main pulmonary artery and the left and right pulmonary lobe arteries in the observation group were higher than those in the control group, and the differences were all statistically significant ( t = -3.65 to -3.89, P < 0.05). The SNR and CNR of the observation groups 2 and 3 were greater than those of the control group ( t = -9.20 to -2.98, P < 0.05). The consistency of subjective evaluations between the two observers was good ( Kappa = 0.729 - 0.879, P < 0.05). There was no statistically significant difference in the subjective score of pulmonary artery visibility between the control and observation group ( P > 0.05). The subjective scores for image noise in observation group 2 and group 3 were higher than those in the control group ( U =598.50, 654.00, P < 0.05). The presence of artifacts due to sclerosis in the superior vena cava was significantly lower in the observation group compared to the control group ( χ2 = 46.09, P < 0.001). Conclusions:The combination of auto-prescription technique with ASIR-V reconstruction algorithm and low contrast agent imaging protocol can reduce the radiation dose and contrast agent dose without compromising image quality, and enable personalized double low CTPA imaging.
2.Guideline for Adult Weight Management in China
Weiqing WANG ; Qin WAN ; Jianhua MA ; Guang WANG ; Yufan WANG ; Guixia WANG ; Yongquan SHI ; Tingjun YE ; Xiaoguang SHI ; Jian KUANG ; Bo FENG ; Xiuyan FENG ; Guang NING ; Yiming MU ; Hongyu KUANG ; Xiaoping XING ; Chunli PIAO ; Xingbo CHENG ; Zhifeng CHENG ; Yufang BI ; Yan BI ; Wenshan LYU ; Dalong ZHU ; Cuiyan ZHU ; Wei ZHU ; Fei HUA ; Fei XIANG ; Shuang YAN ; Zilin SUN ; Yadong SUN ; Liqin SUN ; Luying SUN ; Li YAN ; Yanbing LI ; Hong LI ; Shu LI ; Ling LI ; Yiming LI ; Chenzhong LI ; Hua YANG ; Jinkui YANG ; Ling YANG ; Ying YANG ; Tao YANG ; Xiao YANG ; Xinhua XIAO ; Dan WU ; Jinsong KUANG ; Lanjie HE ; Wei GU ; Jie SHEN ; Yongfeng SONG ; Qiao ZHANG ; Hong ZHANG ; Yuwei ZHANG ; Junqing ZHANG ; Xianfeng ZHANG ; Miao ZHANG ; Yifei ZHANG ; Yingli LU ; Hong CHEN ; Li CHEN ; Bing CHEN ; Shihong CHEN ; Guiyan CHEN ; Haibing CHEN ; Lei CHEN ; Yanyan CHEN ; Genben CHEN ; Yikun ZHOU ; Xianghai ZHOU ; Qiang ZHOU ; Jiaqiang ZHOU ; Hongting ZHENG ; Zhongyan SHAN ; Jiajun ZHAO ; Dong ZHAO ; Ji HU ; Jiang HU ; Xinguo HOU ; Bimin SHI ; Tianpei HONG ; Mingxia YUAN ; Weibo XIA ; Xuejiang GU ; Yong XU ; Shuguang PANG ; Tianshu GAO ; Zuhua GAO ; Xiaohui GUO ; Hongyi CAO ; Mingfeng CAO ; Xiaopei CAO ; Jing MA ; Bin LU ; Zhen LIANG ; Jun LIANG ; Min LONG ; Yongde PENG ; Jin LU ; Hongyun LU ; Yan LU ; Chunping ZENG ; Binhong WEN ; Xueyong LOU ; Qingbo GUAN ; Lin LIAO ; Xin LIAO ; Ping XIONG ; Yaoming XUE
Chinese Journal of Endocrinology and Metabolism 2025;41(11):891-907
Body weight abnormalities, including overweight, obesity, and underweight, have become a dual public health challenge in Chinese adults: overweight and obesity lead to a variety of chronic complications, while underweight increases the risks of malnutrition, sarcopenia, and organ dysfunction. To systematically address these issues, multidisciplinary experts in endocrinology, sports science, nutrition, and psychiatry from various regions have held multiple weight management seminars. Based on the latest epidemiological data and clinical evidence, they expanded the guideline to include assessment and intervention strategies for underweight, in addition to the core content of obesity management. This guideline outlines the etiological mechanisms, evaluation methods, and multidimensional management strategies for overweight and obesity, covering key areas such as diagnosis and assessment, medical nutrition therapy, exercise prescription, pharmacological intervention, and psychological support. It is intended to provide a scientific and standardized approach to weight management across the adult population, aiming to curb the rising prevalence of obesity, mitigate complications associated with abnormal body weight, and improve nutritional status and overall quality of life.
3.Deep learning image reconstruction algorithm combined with a large reconstruction matrix for low-dose CT screening of lung nodules
Changyu DU ; Wei WEI ; Mengting HU ; Jingyi ZHANG ; Qiye CHENG ; Jian HE ; Anliang CHEN ; Yijun LIU
Journal of Practical Radiology 2025;41(11):1886-1890
Objective To explore the application value of deep learning image reconstruction(DLIR)algorithm combined with a large reconstruction matrix in lung nodules screening using low-dose computed tomography(LDCT)of the chest.Methods Patients who underwent LDCT scans were prospectively enrolled.The control group(group A)used the iterative reconstruction(IR)algorithm(Karl)with a reconstruction level of Karl 5,reconstructed images of 512×512(group A1)matrix,and 1 024 × 1 024(group A2)matrix.The experimental group employed DLIR combined with 512×512(group B)matrix and 1 024 × 1 024(group C)matrix for image reconstruction at levels 1-5,which were recorded as groups B1-5 and groups C1-5.The CT values and standard deviation(SD)values of the lung parenchyma and tracheal air were measured,and the signal-to-noise ratio(SNR)was calculated.The overall lung image quality was scored on a Likert 5-point scale,and the subgroup with the best lung image quality was selected.The lung nodule detec-tion rate and clarity were compared with group A1.Results Under the same reconstruction matrix,the CT values of the tracheal air and lung parenchyma in the experimental group showed no significant difference compared to the control group,while the SD values were lower and SNR were higher(P<0.05).Within groups B and C,as the DLIR level increased,the SD values of the tracheal air and lung paren-chyma gradually decreased,and SNR gradually improved(P<0.05).Subjective scores for the image quality in groups B and C initially increased and then decreased,with group B3 and group C4 showed the best image quality.No difference was observed in objective eval-uation between the two groups,but the subjective image quality score of group C4 was superior to group B3(P<0.05).Subjective eval-uation of lung nodule display in group C4 was better than in group A1(P<0.05).Conclusion DLIR algorithm combined with a large reconstruction matrix is feasible for lung nodules screening in chest LDCT,reducing image noise while improving lung nodules clarity,demonstrating significant clinical value.
4.Study on the efficacy and safety of Metformin hydrochloride enteric-coated capsules in patients with type 2 diabetes mellitus
Yiming WU ; Jian ZHANG ; Nan GU ; Qijuan DONG ; Ruiyun LIU ; Hong ZHANG ; Haixia LIU ; Yongcai ZHAO ; Lin CHENG ; Lianshan PU ; Fang BIAN ; Gang HE ; Quanmin LI ; Wei DU ; Zhaoling WANG ; Wei XU ; Liyong ZHONG ; Xiaohui GUO
Chinese Journal of Diabetes 2025;33(3):210-214
Objective To evaluate the efficacy and safety of enteric-coated metformin hydrochloride capsules(Junlida?)in patients with T2DM and poor glycemic control under lifestyle interventions.Methods In this study,419 patients with T2DM were recruited from 15 research centers from July 2020 to March 2022,and randomly divided into observation(Obs)group(n=209)and control group(Con,n=210)using a multicenter,randomized,double-blind,non-inferiority trial design.Patients in the Obs group were treated with enteric-coated Metformin hydrochloride capsules(Junlida?),and patients in the Con group were treated with Metformin hydrochloride tablets(Glucophage?).The optimal effective dose of 2 g/d was achieved within 4 weeks,and the reasonable dose was maintained until the end of treatment.The treatment period was 24 weeks.HbA1c and its compliance rate,FPG,and body weight were compared between the two groups in full analysis set(FAS)and protocol set(PPS).Safety and adverse events(AE)were evaluated in safety set(SS).Results A total of 414 participants were randomized(207 cases in Obs group and 207 cases in Con group).414 cases in FAS population(207 cases in Obs group and 207 cases in Con group),and 328 cases in PPS population(164 cases in Obs group and 164 cases in Con group),and 414 cases in SS population(207 cases in Obs group and 207 cases in Con group).After treatment,HbA1c,FPG and body weight were lower in both groups(P<0.05)in FAS and PPS.HbA1c compliance rate was not significantly different between the two groups in FAS and PPS(P>0.05).The results of non-inferiority test showed that the lower limit was>-0.4%in both FAS(-0.154,95%CI-0.384~0.069)and PPS(-0.139,95%CI-0.390~0.112),and the Obs group reached non-inferiority end point.The achievement rate,compliance rate,safety index and incidence of AE were not significantly different between the two groups(P>0.05).Conclusions Junlida? demonstrated non-inferiority to Glucophage? in glycemic control and can be safely and effectively used in patients with diabetes.
5.Application of Auto-prescription combined with low-dose contrast and iterative reconstruction algorithm in the CT angiography of thoracodorsal artery
Jian HE ; Yijun LIU ; Wei WEI ; Mengting HU ; Jingyi ZHANG ; Qiye CHENG ; Deshuo DONG ; Zhiming MA ; Changyu DU
Journal of Practical Radiology 2025;41(5):861-865
Objective To explore the application value of Auto-prescription combined with low-dose contrast and adaptive statisti-cal iterative reconstruction-Veo(ASIR-V)algorithm in the computed tomography angiography(CTA)of thoracodorsal artery(TDA).Methods A total of 100 patients who underwent TDA CTA examination were prospectively selected.A tube voltage of 120 kVp and contrast agent of 1.5 mL/kg were used for group A(50 cases),and images were reconstructed with 40% post-set ASIR-V.The Auto-prescription for tube voltage and contrast agent of 1.2 mL/kg were used for group B(50 cases),while images were reconstruc-ted with 40%,60%,and 80% post-set ASIR-V,labeled as subgroups B1 to B3.The objective and subjective evaluation results of the images were compared between and within groups.Results Group A had an effective dose(ED)of 2.98(2.65,4.03)mSv,while group B had an ED of 1.92(1.44,3.33)mSv.The iodine intake in group B was lower than that in group A,and the CT value of the axillary artery in group B was significantly higher than that in group A(P<0.001).With the increased of ASIR-V level in group B,the signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR)of the images gradually increased(P<0.05).In terms of subjec-tive scores on axial images,both subgroups B2 and B3 were superior to group A(P<0.001);with the increased of ASIR-V level in group B,subjective scores of axial images increased first and then decreased,among which subjective score of subgroup B2 was the highest and the differences were statistically significant(P<0.001).In terms of subjective scores on three-dimensional image quality,subgroups B1 to B3 were superior to group A(P<0.001).Conclusion The use of Auto-prescription combined with low-dose con-trast and 60% ASIR-V can significantly optimize the display of TDA,and reduce the radiation dose and contrast agent dose to a certain extent.
6.Guideline for Adult Weight Management in China
Weiqing WANG ; Qin WAN ; Jianhua MA ; Guang WANG ; Yufan WANG ; Guixia WANG ; Yongquan SHI ; Tingjun YE ; Xiaoguang SHI ; Jian KUANG ; Bo FENG ; Xiuyan FENG ; Guang NING ; Yiming MU ; Hongyu KUANG ; Xiaoping XING ; Chunli PIAO ; Xingbo CHENG ; Zhifeng CHENG ; Yufang BI ; Yan BI ; Wenshan LYU ; Dalong ZHU ; Cuiyan ZHU ; Wei ZHU ; Fei HUA ; Fei XIANG ; Shuang YAN ; Zilin SUN ; Yadong SUN ; Liqin SUN ; Luying SUN ; Li YAN ; Yanbing LI ; Hong LI ; Shu LI ; Ling LI ; Yiming LI ; Chenzhong LI ; Hua YANG ; Jinkui YANG ; Ling YANG ; Ying YANG ; Tao YANG ; Xiao YANG ; Xinhua XIAO ; Dan WU ; Jinsong KUANG ; Lanjie HE ; Wei GU ; Jie SHEN ; Yongfeng SONG ; Qiao ZHANG ; Hong ZHANG ; Yuwei ZHANG ; Junqing ZHANG ; Xianfeng ZHANG ; Miao ZHANG ; Yifei ZHANG ; Yingli LU ; Hong CHEN ; Li CHEN ; Bing CHEN ; Shihong CHEN ; Guiyan CHEN ; Haibing CHEN ; Lei CHEN ; Yanyan CHEN ; Genben CHEN ; Yikun ZHOU ; Xianghai ZHOU ; Qiang ZHOU ; Jiaqiang ZHOU ; Hongting ZHENG ; Zhongyan SHAN ; Jiajun ZHAO ; Dong ZHAO ; Ji HU ; Jiang HU ; Xinguo HOU ; Bimin SHI ; Tianpei HONG ; Mingxia YUAN ; Weibo XIA ; Xuejiang GU ; Yong XU ; Shuguang PANG ; Tianshu GAO ; Zuhua GAO ; Xiaohui GUO ; Hongyi CAO ; Mingfeng CAO ; Xiaopei CAO ; Jing MA ; Bin LU ; Zhen LIANG ; Jun LIANG ; Min LONG ; Yongde PENG ; Jin LU ; Hongyun LU ; Yan LU ; Chunping ZENG ; Binhong WEN ; Xueyong LOU ; Qingbo GUAN ; Lin LIAO ; Xin LIAO ; Ping XIONG ; Yaoming XUE
Chinese Journal of Endocrinology and Metabolism 2025;41(11):891-907
Body weight abnormalities, including overweight, obesity, and underweight, have become a dual public health challenge in Chinese adults: overweight and obesity lead to a variety of chronic complications, while underweight increases the risks of malnutrition, sarcopenia, and organ dysfunction. To systematically address these issues, multidisciplinary experts in endocrinology, sports science, nutrition, and psychiatry from various regions have held multiple weight management seminars. Based on the latest epidemiological data and clinical evidence, they expanded the guideline to include assessment and intervention strategies for underweight, in addition to the core content of obesity management. This guideline outlines the etiological mechanisms, evaluation methods, and multidimensional management strategies for overweight and obesity, covering key areas such as diagnosis and assessment, medical nutrition therapy, exercise prescription, pharmacological intervention, and psychological support. It is intended to provide a scientific and standardized approach to weight management across the adult population, aiming to curb the rising prevalence of obesity, mitigate complications associated with abnormal body weight, and improve nutritional status and overall quality of life.
7.Application value of auto-prescription technique combined with iterative reconstruction algorithm in low-dose CT pulmonary angiography
Changyu DU ; Yijun LIU ; Wei WEI ; Mengting HU ; Jingyi ZHANG ; Qiye CHENG ; Jian HE ; Anliang CHEN
Chinese Journal of Radiological Medicine and Protection 2025;45(7):685-691
Objective:To explore the application value of the double-low technique of auto-prescription technique combined with iterative reconstruction algorithm in CT pulmonary angiography (CTPA).Methods:A total of 86 patients who were clinically suspected of having pulmonary embolism and underwent CTPA examination in the First Affiliated Hospital of Dalian Medical University were prospectively collected and randomly assigned to a control group ( n = 45) and an observation group ( n = 41) according to the random number table method. In the control group, a tube voltage of 120 kVp was used with a standard iodine contrast agent dose of 60 ml, and images were reconstructed using the 40% adaptive statistical iterative reconstruction algorithm (ASIR-V). In the observation group, the tube voltage was set by auto-prescription technique, and 0.4 ml/kg of personalized low iodine contrast agent was used. Images were reconstructed with 40%, 60%, and 80% ASIR-V, respectively, and designated as observation 1, observation 2, and observation 3 respectively. The volume CT dose index (CTDI vol), dose-length product (DLP), and effective dose ( E) were recorded and compared among the four groups. The CT values and standard deviation (SD) of the main pulmonary artery, left and right pulmonary arteries, as well as the left and right pulmonary lobe arteries were measured, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of these arteries were calculated. Additionally, the SD value at the contrast medium concentration in the superior vena cava was measured, and the artifact index (AI) was subsequently calculated. Two observers independently assessed the visibility of the pulmonary arteries, image noise, and sclerosis artifacts in the superior vena cava using a blinded method. Results:The E in the observation group was 3.28 (2.08, 3.93) mSv, which was significantly lower than that in the control group [5.03 (4.86, 5.20)] mSv, and the difference was statistically significant ( Z = 174.00, P < 0.05). The contrast agent dosage in the observation group was 28 (25, 30) ml, which was lower than that in the control group (60 ml), and the difference was statistically significant ( Z = 0, P < 0.05). The CT values for the main pulmonary artery and the left and right pulmonary lobe arteries in the observation group were higher than those in the control group, and the differences were all statistically significant ( t = -3.65 to -3.89, P < 0.05). The SNR and CNR of the observation groups 2 and 3 were greater than those of the control group ( t = -9.20 to -2.98, P < 0.05). The consistency of subjective evaluations between the two observers was good ( Kappa = 0.729 - 0.879, P < 0.05). There was no statistically significant difference in the subjective score of pulmonary artery visibility between the control and observation group ( P > 0.05). The subjective scores for image noise in observation group 2 and group 3 were higher than those in the control group ( U =598.50, 654.00, P < 0.05). The presence of artifacts due to sclerosis in the superior vena cava was significantly lower in the observation group compared to the control group ( χ2 = 46.09, P < 0.001). Conclusions:The combination of auto-prescription technique with ASIR-V reconstruction algorithm and low contrast agent imaging protocol can reduce the radiation dose and contrast agent dose without compromising image quality, and enable personalized double low CTPA imaging.
8.Prospective study on the association between lifestyles and the risk of type 2 diabetes in adult residents
Meng-ru HE ; Xiao-li XU ; Gen-ming ZHAO ; Xing LIU ; Hui-lin XU ; Dan-dan HE ; Yu-ping CHENG ; Yong-gen JIANG ; Qian PENG ; Jian-hua SHI ; Xiao-hua LIU
Fudan University Journal of Medical Sciences 2025;52(5):647-656,685
Objective To analyze the association between lifestyle and the risk of type 2 diabetes(T2D)among adult residents.Methods The data was sourced from the Shanghai Suburban Adult Cohort and Biobank.A total of 42 096 adult residents who had not developed T2D were recruited from four districts of Shanghai(Songjiang,Jiading,Minhang,and Xuhui)between 2016 and 2019.The follow-up ended on Feb 28,2023.A structured questionnaire was used to collect information on six lifestyle-related items,including smoking,alcohol consumption,BMI,waist circumference(WC),physical activity,and diet.The unhealthy lifestyle scores(UHLS)were calculated by counting the number of all the unhealthy lifestyle items,with a range of 0-6.New-onset T2D events diagnosed by physicians were obtained through the medical information system.Cox proportional hazards regression model and restricted cubic spline model were utilized to evaluate the association between unhealthy lifestyles and the risk of T2D incidence.Results About 28.1%of the participants led 4-6 unhealthy lifestyles.A total of 1 752 new T2D cases were identified during 218 513.4 person-years of follow-up.Analysis of single unhealthy lifestyle showed that abnormal WC(HR=1.5,95%CI:1.4-1.7)and abnormal BMI(HR=1.3,95%CI:1.2-1.5)were associated with an increased risk of T2D.Compared with individuals with a UHLS of 0-1,those with a UHLS of 3 and 4-6 had 30%(95%CI:1.1-1.6)and 50%(95%CI:1.2-1.8)higher risks of T2D,respectively.Each additional unhealthy lifestyle was associated with a 10%increase in T2D incidence risk(HR=1.1,95%CI:1.1-1.2).Conclusion The risk of T2D in adult residents increases with the cumulative number of unhealthy lifestyles.Adult residents with abnormal WC or BMI,or have three or more unhealthy lifestyles accumulated,will increase the risk of new-onset T2D.
9.Long-term follow-up of percutaneous pulmonary valve implantation using domestic self-expanding valve-prospective single-center experience
Qian-bei HE ; Qiao LI ; Yi-jian LI ; Rui-tao LI ; Bo-feng CHAI ; Zhi-cheng CHEN ; Zhi-xiang YU ; Zhen-gang ZHAO ; Yuan FENG
Chinese Journal of Interventional Cardiology 2025;33(5):241-248
Objective To explore the long-term efficacy of percutaneous pulmonary valve implantation(PPVI)and the durability of the domestic self-expanding Venus P valve.Methods A total of 8 patients with post-surgical right ventricular outflow tract(RVOT)dysfunction,who were admitted to hospital from October 2014 to July 2016 and deemed anatomically suitable for PPVI with self-expanding valve,were included prospectively.Clinical,imaging,procedural and follow-up data were analyzed.The survival rates,perioperative and long-term complication rates,long-term efficacy of PPVI,and long-term function of Venus P in 8 patients were evaluated.The immediate procedural results were evaluated by clinical implant success rate,which is defined as successful valve implantation with echocardiography-assessed pulmonary regurgitation<moderate and peak trans-pulmonary pressure gradient<40 mmHg.Results A total of 8 patients were included,with 7 females,aged 14 to 36 years.The initial diagnosis included post-surgical Tetralogy of Fallot(5 cases),post-surgical Trilogy of Fallot(1 case),post-surgical Quadricuspid pulmonary valve stenosis(1 case)and post-surgical Double-Outlet Right Ventricle(1 case).The indications of PPVI included RVOT-pulmonary obstruction and regurgitation(1 case)and isolated regurgitation(7 cases).Clinical implant success was achieved in all of the 8 patients with firmly fixed valve,and there were no such complications as valve detachment,displacement or stent fracture.All patients experienced significant symptom relief after the procedure.The right ventricular end-diastolic volume index(RVEDVi)measured by CMR 6 months after PPVI showed a significant decrease compared to preprocedural values[(89.99±13.85)ml/m2 vs.(144.93±11.28)ml/m2,P=0.001].Postoperative pulmonary regurgitation were significantly improved or disappeared in all patients,and there was no statistically significant difference in the average peak pressure gradient measured by echocardiogram between preoperative and the latest follow-up[(23.25±8.39)mmHg vs.(18.75±6.28)mmHg,P=0.210].Over an average follow-up period of(9.25±0.71)years,1 case of infective endocarditis occurred 5 years after PPVI.During the follow-up,no death,deterioration of heart failure,malignant arrhythmia or other serious complications were observed.All patients completed 8-year follow-up,and 3 completed 10-year follow-up.All patients were graded as NYHA functional class one at the latest follow-up.Conclusions PPVI using the domestically produced self-expanding Venus P is safe and feasible for the treatment of patients with post-surgical RVOT dysfunction and suitable anatomy.Our study confirms the long-term efficacy and durability of Venus P from multiple perspectives,and no severe stent fracture occurred without pre-stent implantation in the native RVOT.
10.Application of Auto-prescription combined with low-dose contrast and iterative reconstruction algorithm in the CT angiography of thoracodorsal artery
Jian HE ; Yijun LIU ; Wei WEI ; Mengting HU ; Jingyi ZHANG ; Qiye CHENG ; Deshuo DONG ; Zhiming MA ; Changyu DU
Journal of Practical Radiology 2025;41(5):861-865
Objective To explore the application value of Auto-prescription combined with low-dose contrast and adaptive statisti-cal iterative reconstruction-Veo(ASIR-V)algorithm in the computed tomography angiography(CTA)of thoracodorsal artery(TDA).Methods A total of 100 patients who underwent TDA CTA examination were prospectively selected.A tube voltage of 120 kVp and contrast agent of 1.5 mL/kg were used for group A(50 cases),and images were reconstructed with 40% post-set ASIR-V.The Auto-prescription for tube voltage and contrast agent of 1.2 mL/kg were used for group B(50 cases),while images were reconstruc-ted with 40%,60%,and 80% post-set ASIR-V,labeled as subgroups B1 to B3.The objective and subjective evaluation results of the images were compared between and within groups.Results Group A had an effective dose(ED)of 2.98(2.65,4.03)mSv,while group B had an ED of 1.92(1.44,3.33)mSv.The iodine intake in group B was lower than that in group A,and the CT value of the axillary artery in group B was significantly higher than that in group A(P<0.001).With the increased of ASIR-V level in group B,the signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR)of the images gradually increased(P<0.05).In terms of subjec-tive scores on axial images,both subgroups B2 and B3 were superior to group A(P<0.001);with the increased of ASIR-V level in group B,subjective scores of axial images increased first and then decreased,among which subjective score of subgroup B2 was the highest and the differences were statistically significant(P<0.001).In terms of subjective scores on three-dimensional image quality,subgroups B1 to B3 were superior to group A(P<0.001).Conclusion The use of Auto-prescription combined with low-dose con-trast and 60% ASIR-V can significantly optimize the display of TDA,and reduce the radiation dose and contrast agent dose to a certain extent.

Result Analysis
Print
Save
E-mail