1.Preliminary efficacy observation of 3D printed functional spinal external fixation brace combined with McKenzie therapy in the treatment of lumbar disc herniation.
Ning-Xia WANG ; Ping CHEN ; Hai-Dong WANG ; Jing JI ; Fang-Hong NIAN ; Xin LIU ; Chong-Fei JIN ; Duo-Ming ZHAO ; Hao-Lin LI ; Wei-Gang CHENG ; Gui-Lin LAI ; Guo-Biao WU
China Journal of Orthopaedics and Traumatology 2025;38(10):1047-1054
OBJECTIVE:
To observe the clinical efficacy of 3D printing spinal external fixator combined with McKenzie therapy for patients with lumbar dics herniation (LDH).
METHODS:
Sixty patients with LDH between January 2022 and January 2023 were enrolled. Among them, 30 patients were given McKinsey training. According to different treatment methods, all patients were divided into McKenzie group and McKenzie + 3D printing group, 30 patients in each group. The McKenzie group provided McKenzie therapy. The McKenzie + 3D printing group were treated with 3D printing spinal external fixation brace on the basis of McKenzie therapy. Patients in both groups were between 25 and 60 years of age and had their first illness. In the McKenzie group, there were 19 males and 11 females, with an average age of (48.57±5.86) years old, and the disease duration was (7.03 ±2.39) months. The McKenzie + 3D printing group, there were 21 males and 9 females, with an average age of (48.80±5.92) years old, and the disease duration was(7.30±2.56) months. Pain was evaluated using the visual analogue scale (VAS), and lumbar spine function was assessed using the Oswestry disability index (ODI) and the Japanese Orthopaedic Association (JOA) score. VAS, ODI and JOA scores were compared between two groups before treatment and at 1, 3, 6, 9 and 12 months after treatment.
RESULTS:
All patients were followed up for 12 months. The VAS for the McKenzie combined with 3D printing group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were(6.533±0.860), (5.133±1.008), (3.933±0.868), (2.900±0.759), (2.067±0.640), (1.433±0.504), respectively. In the McKenzie group, the corresponding scores were (6.467±0.860), (5.067±1.048), (4.600±0.968), (3.533±1.008), (2.567±0.728), (1.967±0.809), respectively. The ODI of the McKenzie group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were (41.033±6.810)%, (37.933±6.209)%, (35.467±6.962)%, (27.567±10.081)%, (20.800±7.531)%, (13.533±5.158)%, respectively. For the McKenzie combined with 3D printing group, the corresponding ODI were(38.033±5.605)%, (33.000±6.192)%, (28.767±7.045)%, (22.200±5.517)%, (17.700±4.836)%, (11.900±2.771)%, respectively. The JOA scores of the McKenzie combined with 3D printing group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were(8.900±2.074), (13.133±2.330), (15.700±3.583), (20.400±3.480), (22.267±3.084), (24.833±2.640), respectively. In the McKenzie group, the corresponding scores were(9.200±2.091), (12.267±2.406), (15.333±3.198), (18.467±2.240), (20.133±2.751), (22.467±2.849), respectively. Before the initiation of treatment, no statistically significant differences were observed in the VAS, ODI, and JOA scores between two groups (P>0.05). At 3, 6, 9, and 12 months post-treatment, the VAS in the McKenzie combined with 3D printing group was significantly lower than that in the McKenzie group, and the difference was statistically significant (P<0.05). The comparison of ODI between two groups at 1, 3, 6, 9, and 12 months post-treatment revealed statistically significant differences (P<0.05). At 6, 9, and 12 months post-treatment, the JOA score in the McKenzie combined with 3D printing group was significantly higher than that in the McKenzie-only group, and the difference was statistically significant (P<0.05).
CONCLUSION
The combination of 3D printed functional spinal external fixation brace with McKenzie therapy can significantly improve and maintain lumbar function in patients with LDH.
Humans
;
Male
;
Female
;
Middle Aged
;
Printing, Three-Dimensional
;
Intervertebral Disc Displacement/surgery*
;
External Fixators
;
Lumbar Vertebrae/surgery*
;
Adult
;
Braces
;
Treatment Outcome
2.Prognostic value of quantitative flow ratio measured immediately after percutaneous coronary intervention for chronic total occlusion.
Zheng QIAO ; Zhang-Yu LIN ; Qian-Qian LIU ; Rui ZHANG ; Chang-Dong GUAN ; Sheng YUAN ; Tong-Qiang ZOU ; Xiao-Hui BIAN ; Li-Hua XIE ; Cheng-Gang ZHU ; Hao-Yu WANG ; Guo-Feng GAO ; Ke-Fei DOU
Journal of Geriatric Cardiology 2025;22(4):433-442
BACKGROUND:
The clinical impact of post-percutaneous coronary intervention (PCI) quantitative flow ratio (QFR) in patients treated with PCI for chronic total occlusion (CTO) was still undetermined.
METHODS:
All CTO vessels treated with successful anatomical PCI in patients from PANDA III trial were retrospectively measured for post-PCI QFR. The primary outcome was 2-year vessel-oriented composite endpoints (VOCEs, composite of target vessel-related cardiac death, target vessel-related myocardial infarction, and ischemia-driven target vessel revascularization). Receiver operator characteristic curve analysis was conducted to identify optimal cutoff value of post-PCI QFR for predicting the 2-year VOCEs, and all vessels were stratified by this optimal cutoff value. Cox proportional hazards models were employed to calculate the hazard ratio (HR) with 95% CI.
RESULTS:
Among 428 CTO vessels treated with PCI, 353 vessels (82.5%) were analyzable for post-PCI QFR. 31 VOCEs (8.7%) occurred at 2 years. Mean value of post-PCI QFR was 0.92 ± 0.13. Receiver operator characteristic curve analysis shown the optimal cutoff value of post-PCI QFR for predicting 2-year VOCEs was 0.91. The incidence of 2-year VOCEs in the vessel with post-PCI QFR < 0.91 (n = 91) was significantly higher compared with the vessels with post-PCI QFR ≥ 0.91 (n = 262) (22.0% vs. 4.2%, HR = 4.98, 95% CI: 2.32-10.70).
CONCLUSIONS
Higher post-PCI QFR values were associated with improved prognosis in the PCI practice for coronary CTO. Achieving functionally optimal PCI results (post-PCI QFR value ≥ 0.91) tends to get better prognosis for patients with CTO lesions.
3.A reporter gene assays for bioactivity determination of human chorinonic gonadotropin
Ying HUANG ; Xiao-ming ZHANG ; He-yang LI ; Lü-yin WANG ; Hui ZHANG ; Ping LÜ ; Jing LI ; Xiang-dong GAO ; Cheng-gang LIANG
Acta Pharmaceutica Sinica 2024;59(2):432-438
This study constructed a LHCGR-CRE-luc-HEK293 transgenic cell line according to the activation of the cAMP signaling pathway after recombinant human chorionic gonadotropin binding to the receptor. The biological activity of recombinant human chorionic gonadotropin was assayed using a luciferase assay system. The relative potency of the samples was calculated using four-parameter model. And the method conditions were optimized to validate the specificity, relative accuracy, precision and linearity of the method. The results showed that there was a quantitative potency relationship of human chorinonic gonadotropin (hCG) in the method and it was in accordance with the four-parameter curve. After optimization, the conditions were determined as hCG dilution concentration of 2.5 μg·mL-1, dilution ratio of 1∶4, cell number of 10 000-15 000 cells/well, and induction time of 6 h. The method had good specificity, relative accuracy with relative bias ranging from -8.9% to 3.4%, linear regression equation correlation coefficient of 0.996, intermediate precision geometric coefficient of variation ranging from 3.3% to 15.0%, and linearity range of 50% to 200%. This study successfully established and validated a reporter gene method to detect hCG biological activity, which can be used for hCG biological activity assay and quality control.
4.Predictive Value of Albumin-Bilirubin Score Combined with Liver Function Index and CEA for Liver Metastasis of Colorectal Cancer
Wanli FAN ; Dong HE ; Shuze ZHANG ; Gang CHEN ; Bin ZHAO ; Zhibin CHENG
Medical Journal of Peking Union Medical College Hospital 2024;15(1):99-108
5.Association of Triglyceride Glucose-Derived Indices with Recurrent Events Following Atherosclerotic Cardiovascular Disease
Sha LI ; Hui-Hui LIU ; Yan ZHANG ; Meng ZHANG ; Hui-Wen ZHANG ; Cheng-Gang ZHU ; Yuan-Lin GUO ; Na-Qiong WU ; Rui-Xia XU ; Qian DONG ; Ke-Fei DOU ; Jie QIAN ; Jian-Jun LI
Journal of Obesity & Metabolic Syndrome 2024;33(2):133-142
Background:
Triglyceride glucose (TyG) and TyG-body mass index (TyG-BMI) are reliable surrogate indices of insulin resistance and used for risk stratification and outcome prediction in patients with atherosclerotic cardiovascular disease (ASCVD). Here, we inserted estimated average glucose (eAG) into the TyG (TyAG) and TyG-BMI (TyAG-BMI) as derived parameters and explored their clinical significance in cardiovascular risk prediction.
Methods:
This was a population-based cohort study of 9,944 Chinese patients with ASCVD. The baseline admission fasting glucose and A1C-derived eAG values were recorded. Cardiovascular events (CVEs) that occurred during an average of 38.5 months of follow-up were recorded. We stratified the patients into four groups by quartiles of the parameters. Baseline data and outcomes were analyzed.
Results:
Distribution of the TyAG and TyAG-BMI indices shifted slightly toward higher values (the right side) compared with TyG and TyG-BMI, respectively. The baseline levels of cardiovascular risk factors and coronary severity increased with quartile of TyG, TyAG, TyG-BMI, and TyAG-BMI (all P<0.001). The multivariate-adjusted hazard ratios for CVEs when the highest and lowest quartiles were compared from low to high were 1.02 (95% confidence interval [CI], 0.77 to 1.36; TyG), 1.29 (95% CI, 0.97 to 1.73; TyAG), 1.59 (95% CI, 1.01 to 2.58; TyG-BMI), and 1.91 (95% CI, 1.16 to 3.15; TyAG-BMI). The latter two showed statistical significance.
Conclusion
This study suggests that TyAG and TyAG-BMI exhibit more information than TyG and TyG-BMI in disease progression among patients with ASCVD. The TyAG-BMI index provided better predictive performance for CVEs than other parameters.
6.Diagnostic value of serum homocysteine,soluble stromelysin 2 and cystatin C for chronic heart failure
Gong-Min CHENG ; Yan YUAN ; Xu-Qing DONG ; Zhi-Gang LUO
Chinese Journal of cardiovascular Rehabilitation Medicine 2024;33(1):45-49
Objective:To investigate the diagnostic value of serum homocysteine(Hcy),soluble stromelysin 2(sST2)and cystatin C(CysC)for chronic heart failure(CHF).Methods:A total of 86 CHF patients admitted in our hospital were se-lected as CHF group,and 86 healthy individuals who underwent physical examination simultaneously were selected as healthy control group.Serum levels of Hcy,sST2 and CysC,plasma level of N terminal pro brain natriuretic peptide(NT-proBNP)and cardiac function indexes[left atrial diameter(LAD),left ventricular end diastolic diameter(LVEDd),left ventricular ejection fraction(LVEF)]were measured between two groups.Pearson correlation analysis was used to analyze the correlation among serum Hcy,sST2,CysC,plasma NT-proBNP and cardiac function indexes.Receiver operating characteristic curve(ROC)was drawn to evaluate the diagnostic value of serum Hcy,sST2 and CysC and their combined detection for CHF.Results:Compared with healthy control group,there were significant rise in scrum levels of Hcy,sST2 and CysC,plasma NT-proBNP level,LAD and LVEDd,and significant reduction in LVEF in CHF group,P=0.001 all.Pearson correlation analysis indicated that serum Hcy,sST2 and CysC levels were significant positively correlated with plas-ma NT-proBNP level,LAD and LVEDd(r=0.385~0.511,P<0.05 or<0.01),and significant inversely correlated with LVEF(r=-0.424~-0.402,P<0.05 all).AUC of single detection of serum Hcy,sST2 and CysC diagnosing CHF was 0.624,0.720 and 0.870 respectively,and AUC of their combination was 0.865,which was significantly higher than any single detection,P<0.05 or<0.01.Conclusion:Serum levels of Hcy,sST2 and CysC abnormally increase in CHF patients,which can be used as auxiliary diagnostic indexes for CHF.The triple combined detection is of great signifi-cance for the diagnosis of CHF.
7.Variation rules of main secondary metabolites in Hedysari Radix before and after rubbing strip
Xu-Dong LUO ; Xin-Rong LI ; Cheng-Yi LI ; Peng QI ; Ting-Ting LIANG ; Shu-Bin LIU ; Zheng-Ze QIANG ; Jun-Gang HE ; Xu LI ; Xiao-Cheng WEI ; Xiao-Li FENG ; Ming-Wei WANG
Chinese Traditional Patent Medicine 2024;46(3):747-754
AIM To investigate the variation rules of main secondary metabolites in Hedysari Radix before and after rubbing strip.METHODS UPLC-MS/MS was adopted in the content determination of formononetin,ononin,calycosin,calycosin-7-glucoside,medicarpin,genistein,luteolin,liquiritigenin,isoliquiritigenin,vanillic acid,ferulic acid,γ-aminobutyric acid,adenosine and betaine,after which cluster analysis,principal component analysis and orthogonal partial least squares discriminant analysis were used for chemical pattern recognition to explore differential components.RESULTS After rubbing strip,formononetin,calycosin,liquiritigenin and γ-aminobutynic acid demonstrated increased contents,along with decreased contents of ononin,calycosin-7-glucoside and vanillic acid.The samples with and without rubbing strip were clustered into two types,calycosin-7-glucoside,formononetin,γ-aminobutynic acid,vanillic acid,calycosin-7-glucoside and formononetin were differential components.CONCLUSION This experiment clarifies the differences of chemical constituents in Hedysari Radix before and after rubbing strip,which can provide a reference for the research on rubbing strip mechanism of other medicinal materials.
8.Association of Triglyceride Glucose-Derived Indices with Recurrent Events Following Atherosclerotic Cardiovascular Disease
Sha LI ; Hui-Hui LIU ; Yan ZHANG ; Meng ZHANG ; Hui-Wen ZHANG ; Cheng-Gang ZHU ; Yuan-Lin GUO ; Na-Qiong WU ; Rui-Xia XU ; Qian DONG ; Ke-Fei DOU ; Jie QIAN ; Jian-Jun LI
Journal of Obesity & Metabolic Syndrome 2024;33(2):133-142
Background:
Triglyceride glucose (TyG) and TyG-body mass index (TyG-BMI) are reliable surrogate indices of insulin resistance and used for risk stratification and outcome prediction in patients with atherosclerotic cardiovascular disease (ASCVD). Here, we inserted estimated average glucose (eAG) into the TyG (TyAG) and TyG-BMI (TyAG-BMI) as derived parameters and explored their clinical significance in cardiovascular risk prediction.
Methods:
This was a population-based cohort study of 9,944 Chinese patients with ASCVD. The baseline admission fasting glucose and A1C-derived eAG values were recorded. Cardiovascular events (CVEs) that occurred during an average of 38.5 months of follow-up were recorded. We stratified the patients into four groups by quartiles of the parameters. Baseline data and outcomes were analyzed.
Results:
Distribution of the TyAG and TyAG-BMI indices shifted slightly toward higher values (the right side) compared with TyG and TyG-BMI, respectively. The baseline levels of cardiovascular risk factors and coronary severity increased with quartile of TyG, TyAG, TyG-BMI, and TyAG-BMI (all P<0.001). The multivariate-adjusted hazard ratios for CVEs when the highest and lowest quartiles were compared from low to high were 1.02 (95% confidence interval [CI], 0.77 to 1.36; TyG), 1.29 (95% CI, 0.97 to 1.73; TyAG), 1.59 (95% CI, 1.01 to 2.58; TyG-BMI), and 1.91 (95% CI, 1.16 to 3.15; TyAG-BMI). The latter two showed statistical significance.
Conclusion
This study suggests that TyAG and TyAG-BMI exhibit more information than TyG and TyG-BMI in disease progression among patients with ASCVD. The TyAG-BMI index provided better predictive performance for CVEs than other parameters.
9.Robotic visualization system-assisted microsurgical reconstruction of the reproductive tract in male rats
Zheng LI ; Jian-Jun DONG ; Ming LIU ; Xun-Zhu WU ; Ren-Feng JIA ; San-Wei GUO ; Kai MENG ; Chen-Cheng YAO ; Er-Lei ZHI ; Gang LIU ; Da-Xian TAN ; Zheng LI ; Peng LI
National Journal of Andrology 2024;30(8):675-680
Objective:To evaluate the safety and efficiency of robotic visualization system(RVS)-assisted microsurgical re-construction of the reproductive tract in male rats and the satisfaction of the surgeons.Methods:We randomly divided 8 adult male SD rats into an experimental and a control group,the former treated by RVS-assisted microsurgical vasoepididymostomy(VE)or vaso-vasostomy(VV),and the latter by VE or VV under the standard operating microscope(SOM).We compared the operation time,me-chanical patency and anastomosis leakage immediately after surgery,and the surgeons'satisfaction between the two groups.Results:No statistically significant difference was observed the operation time between the experimental and the control groups,and no anasto-mosis leakage occurred after VV in either group.The rate of mechanical patency immediately after surgery was 100%in both groups,and that of anastomosis leakage after VE was 16.7%in the experimental group and 14.3%in the control.Compared with the control group,the experimental group achieved dramatically higher scores on visual comfort(3.00±0.76 vs 4.00±0.53,P<0.05),neck/back comfort(2.75±1.16 vs 4.38±1.06,P<0.01)and man-machine interaction(3.88±1.55 va 4.88±0.35,P<0.05).There were no statistically significant differences in the scores on image definition and operating room suitability between the two groups.Conclusion:RVS can be used in microsurgical reconstruction of the reproductive tract in male rats and,with its advantages over SOM in ergonomic design and image definition,has a potential application value in male reproductive system micosurgery.
10.Detection of biological activity of insulin degludec by homogeneous time-resolved fluorescence
Jing GAO ; Lü-yin WANG ; Jing LI ; Ping LÜ ; Xiang-dong GAO ; Cheng-gang LIANG
Acta Pharmaceutica Sinica 2024;59(12):3347-3353
In this study, the CHO_INSR_1284 transgenic cell line was employed as the target cell, utilizing homogeneous time-resolved fluorescence technology to establish a method for detecting the biological activity of insulin degludec. Key parameters were optimized, and validation was conducted in accordance with general principles 9401 and 1431 of the fourth section of the 2020 edition of the Chinese Pharmacopoeia. Results indicated a good dose-response relationship for insulin degludec in this method, aligning with a four-parameter curve. Following optimization, the cell seeding density was set at 3.5×105 cell·mL-1, the initial concentration of insulin degludec at 57.18 μg·mL-1, with a four-fold dilution, a stimulation period of 45 minutes, and an incubation duration of 4 hours. This method demonstrated strong specificity, with the geometric variation coefficient (GCV%) for the five potency levels ranging from 4.1% to 10.6%. The linear regression equation from the linear fitting was

Result Analysis
Print
Save
E-mail