1.Study on the effect of different administration regimens of iprrazole enteric-coated tablets on inhibiting gastric acid secretion
Ting-Yuan PANG ; Zhi WANG ; Zi-Shu HU ; Zi-Han SHEN ; Yue-Qi WANG ; Ya-Qian CHEN ; Xue-Bing QIAN ; Jin-Ying LIANG ; Liang-Ying YI ; Jun-Long LI ; Zhi-Hui HAN ; Guo-Ping ZHONG ; Guo-Hua CHENG ; Hai-Tang HU
The Chinese Journal of Clinical Pharmacology 2024;40(1):92-96
Objective To compare the effects of 20 mg qd and 10 mg bidadministration of iprrazole enteric-coated tablets on the control of gastric acid in healthy subjects.Methods A randomized,single-center,parallel controlled trial was designed to include 8 healthy subjects.Randomly divided into 2 groups,20 mg qd administration group:20 mg enteric-coated tablets of iprrazole in the morning;10 mg bid administration group:10 mg enteric-coated tablets of iprrazole in the morning and 10 mg in the evening.The pH values in the stomach of the subjects before and 24 h after administration were monitored by pH meter.The plasma concentration of iprazole after administration was determined by HPLC-MS/MS.The main pharmacokinetic parameters were calculated by Phoenix WinNonlin(V8.0)software.Results The PK parameters of iprrazole enteric-coated tablets and reference preparations in fasting group were as follows:The Cmax of 20 mg qd group and 10 mg bid group were(595.75±131.15)and(283.50±96.98)ng·mL-1;AUC0-t were(5 531.94±784.35)and(4 686.67±898.23)h·ng·mL-1;AUC0-∞ were(6 003.19±538.59)and(7 361.48±1 816.77)h·ng·mL-1,respectively.The mean time percentage of gastric pH>3 after 20 mg qd and 10 mg bid were 82.64%and 61.92%,and the median gastric pH within 24 h were 6.25±1.49 and 3.53±2.05,respectively.The mean gastric pH values within 24 h were 5.71±1.36 and 4.23±1.45,respectively.The correlation analysis of pharmacokinetic/pharmacodynamics showed that there was no significant correlation between the peak concentration of drug in plasma and the inhibitory effect of acid.Conclusion Compared with the 20 mg qd group and the 10 mg bid group,the acid inhibition effect is better,the administration times are less,and the safety of the two administration regimes is good.
2.Finite element simulation and experimental test of normal coracoclavicular ligament and flexible reconstruction
Guizhu JI ; Qiu ZHENG ; Wuxiang WANG ; Guan WANG ; Wen LI ; Xiaobo LU ; Ke DUAN ; Zhong LI ; Hongbin YANG ; Cheng LIANG
Chinese Journal of Tissue Engineering Research 2024;28(5):706-711
BACKGROUND:For dislocation of acromioclavicular joint induced by coracoclavicular ligament fracture,single EndoButton Plate reconstruction and double EndoButton Plates reconstruction are common repair methods.Further study on the stress distribution and fracture risk of the two repair methods is of great significance. OBJECTIVE:To study the biomechanical properties of the coracoclavicular ligament,and compare the fixation effect,stress distribution and failure mode of single and double EndoButton Plates reconstruction. METHODS:(1)Finite element simulation analysis:Mimics,Wrap and SolidWorks were used to establish normal coracoclavicular ligament,single EndoButton Plate reconstruction and double EndoButton Plates reconstruction.Ansys software was used to analyze the stress and deformation of the scapula and clavicle of each model under vertical load.(2)Sample experiment:Fifteen intact scapular-clavicle specimens were randomly grouped into five groups,with three specimens in each group.In group A,the acromioclavicular ligament was severed and the coracoclavicular ligament remained intact.In group B,acromioclavicular ligaments and trapeoid ligaments were severed,leaving intact conical ligaments.In group C,acromioclavicular ligaments and conical ligaments were cut off,and the intact traprex ligaments were retained.In group D,acromioclavicular and coracoclavicular ligaments were severed,and coracoclavicular ligaments were repaired by single EndoButton Plate reconstruction.In group E,acromioclavicular and coracoclavicular ligaments were severed,and the coracoclavicular ligaments were repaired by double EndoButton Plates reconstruction.The mechanical experiment was carried out by a mechanical testing machine to analyze the biomechanical status,stress distribution and failure patterns of the scapular-clavicle and clavicle. RESULTS AND CONCLUSION:(1)Finite element simulation analysis:The average stress of coracoclavicular ligament attached specimens was the lowest,and the risk of coracoclavicular fracture was less than that of single and double EndoButton Plates reconstruction.The mean stress of the coracoid process was similar in single and double EndoButton Plates reconstruction,and the fracture risk was similar.(2)Sample experiment:In groups A,B,C,D and E,the stiffness of specimens was(26.4±3.5),(19.8±2.8),(21.3±3.2),(57.7±4.1),and(46.2±2.8)N/mm,respectively;the ultimate loads were(545.5±53.7),(360.1±42.1),(250.9±44.4),(643.5±39.1),and(511.9±31.7)N,respectively;global stiffness in groups D and E was higher than that in group A(P=0.000 06,0.000 3);ultimate load in group D was higher than that in group A(P<0.05);the ultimate load was not significantly different between the group E and group A(P>0.05).Ligament fracture was observed in groups A,B and C and coracoid process fracture was found in groups D and E.(3)These results suggest that from the biomechanical analysis,Single EndoButton Plate reconstruction and double EndoButton Plates reconstruction are effective treatment techniques for coracoclavicular ligament fracture in acromioclavicular joint dislocation,but increase the risk of fracture.The double EndoButton Plates reconstruction dispersed the stress of the steel plate and reduced the contact force between the steel plate and bone,but slightly reduced the ultimate bearing capacity.Single and double EndoButton Plates reconstruction should be selected according to the actual clinical situation.
3.Finite element and biomechanical analysis of different implants in repair for unilateral unstable pelvic posterior ring injury
Cheng LIANG ; Linqi ZHANG ; Guan WANG ; Wen LI ; Ke DUAN ; Zhong LI ; Xiaobo LU ; Naiqiang ZHUO
Chinese Journal of Tissue Engineering Research 2024;28(9):1336-1341
BACKGROUND:The stability of the pelvis is mainly determined by the posterior pelvic ring and the sacroiliac joint.The posterior pelvic ring injury and the dislocation of the sacroiliac joint caused by high energy impacts such as car accidents increase year by year.Surgical treatment is the best method,and there are many kinds of endophytorepair methods in clinical practice,but which treatment method has the best biomechanical properties is still controversial. OBJECTIVE:To compare the biomechanical properties of three kinds of internal implants:anterior double plates,posterior bridging plate and tension nail in the repair of unilateral unstable pelvic posterior ring injury,to provide a reference for the clinical treatment and development of a new pelvic tension screw. METHODS:(1)Finite element simulation:Mimics,Wrap and SolidWorks were used to establish normal pelvic model,unilateral injured pelvis model,and three kinds of internal implant repaired models(anterior double plates,posterior bridging plate and tension nail).Ansys was used to analyze the stress and deformation of the models.(2)Biomechanical test:A total of 15 intact pelvic specimens were randomly grouped into five groups,normal pelvic model,unilateral injured pelvis model,anterior double plates,posterior bridging plate and tension nail groups.The mechanical test was performed using an Instron E10000 testing machine. RESULTS AND CONCLUSION:(1)Simulation:In the normal pelvic model,the average displacement of the sacrum was 0.174 mm,and the maximum stress of the sacral iliac bone was 10.51 MPa,and the stress distribution was uniform.The mean sacral displacement of the unilateral injured pelvis model was 0.267 mm,and the stress concentration of the model was obvious.The mean displacement of the sacrum in the three repaired models was close to that in the normal pelvic model,and the stress distribution of the sacral iliac bone in the tension nail repaired model was uniform.(2)Mechanical test:The stiffness of the normal pelvic model was(226.38±4.18)N/mm,and that of the unilateral unstable pelvic model was the smallest(130.02±2.19)N/mm.The deviation of the normal pelvic model stiffness and the three repaired models'stiffness were all within(±10%),and the repair effect was obvious.(3)The simulation results were in agreement with the experimental results.(4)The biomechanics of the tension nail repaired model was the most similar to that of the normal pelvis,and this method was the best.The repairing stiffness of the anterior double plate was too large,and the stress shielding effect was more significant.The posterior bridging plate repair could not solve the compensatory effect of the normal side soft tissue and had defects.This study provides an optimal basis for clinical surgery.(5)The new type of pelvic tension nail should be improved from the point of view of the tension nail to retain the good biomechanical properties of the tension nail,while adding other advantages,such as being used for the osteoporotic pelvis.
4.Results of Lung Cancer Screening with Low-dose Computed Tomography and Exploration of Risk Factors in Guangzhou
LU XUANZHUANG ; QIU QIUXIA ; YANG CHUNYU ; LI CAICHEN ; LI JIANFU ; XIONG SHAN ; CHENG BO ; ZHOU CHUJING ; DU XIAOQIN ; ZHANG YI ; HE JIANXING ; LIANG WENHUA ; ZHONG NANSHAN
Chinese Journal of Lung Cancer 2024;27(5):345-358
Background and objective Both of lung cancer incidence and mortality rank first among all cancers in China.Previous lung cancer screening trials were mostly selective screening for high-risk groups such as smokers.Non-smoking women accounted for a considerable proportion of lung cancer cases in Asia.This study aimed to evaluate the outcome of community-based mass screening in Guangzhou and identify the high-risk factors for lung cancer.Methods Residents aged 40-74 years in Guangzhou were screened with low-dose computed tomography(LDCT)for lung cancer and the pulmonary nodules were classified and managed according to China National Lung Cancer Screening Guideline with Low-dose Computed Tomography(2018 version).The detection rate of positive nodules was calculated.Before the LDCT examination,residents were required to complete a"lung cancer risk factors questionnaire".The risk factors of the questionnaire were analyzed by least absolute shrinkage and selection operator(LASSO)penalized Logistic regression analysis.Results A total of 6256 residents were included in this study.1228 positive nodules(19.63%)and 117 lung cancers were confirmed,including 6 cases of Tis,103 cases of stage Ⅰ(accounting for 88.03%of lung cancer).The results of LASSO penalized Logistic regression analysis indicated that age ≥50 yr(OR=1.07,95%CI:1.06-1.07),history of cancer(OR=3.29,95%CI:3.22-3.37),textile industry(OR=1.10,95%CI:1.08-1.13),use coal for cooking in childhood(OR=1.14,95%CI:1.13-1.16)and food al-lergy(OR=1.10,95%CI:1.07-1.13)were risk factors of lung cancer for female in this district.Conclusion This study highlighted that numerous early stages of lung cancer cases were detected by LDCT,which could be applied to screen-ing of lung cancer in women.Besides,age ≥50 yr,personal history of cancer,textile industry and use coal for cooking in childhood are risk factors for women in this district,which suggested that it's high time to raise the awareness of early lung cancer screening in this group.
5.Evaluation of Mechanical Properties of a Novel Sacroiliac Lag Screw
Cheng LIANG ; Chuanchuan ZHUO ; Guan WANG ; Wen LI ; Ke DUAN ; Zhong LI ; Xiaobo LU ; Naiqiang ZHUO
Journal of Medical Biomechanics 2024;39(2):265-271
Objective To investigate the biomechanical properties of a novel sacroiliac lag screw with a spiral blade.Methods Percutaneous sacroiliac lag screws were used as the controls.Polyurethane material was used to simulate the trabecular bone,and the pullout resistance performance was tested on an Instron mechanical testing machine.Subsequently,pelvic specimens were utilized to analyze the static stiffness and dynamic stability of the novel sacroiliac lag screw in repairing sacroiliac joint injuries under normal standing conditions,with normal pelvis,single-sided sacroiliac joint injury pelvis,percutaneous sacroiliac lag screw-single screw repair,and percutaneous sacroiliac lag screw-double screw repair as controls.Results The damage to the polyurethane material after screw extraction was smaller in the novel sacroiliac lag screw group.The average effective holding displacement of the novel sacroiliac lag screw was significantly greater than that of the percutaneous sacroiliac lag screw(P<0.05).However,the maximum resistance to the pullout force for the percutaneous sacroiliac lag screw was significantly higher than that for the novel sacroiliac lag screw(P<0.05).The stiffness after repair of sacroiliac joint injuries was significantly higher when using a single sacroiliac lag screw than when using two percutaneous sacroiliac lag screws(P<0.05).The displacement amplitude was the highest in the sacroiliac joint injury group,followed by that in the normal group.The displacement amplitudes in the other groups were similar;however,the differences were statistically significant(P<0.05).The dynamic stability of the sacroiliac lag screw repair group was the best,slightly better than that of the percutaneous sacroiliac lag screw-double screw repair group,and the dynamic stability of the sacroiliac joint injury group was the worst.The novel sacroiliac lag screw effectively repaired the sacroiliac joint injuries.Conclusions The novel sacroiliac lag screw can effectively hold the trabecular bone and has practical clinical utility.
6.Efficacy and safety of LY01005 versus goserelin implant in Chinese patients with prostate cancer: A multicenter, randomized, open-label, phase III, non-inferiority trial.
Chengyuan GU ; Zengjun WANG ; Tianxin LIN ; Zhiyu LIU ; Weiqing HAN ; Xuhui ZHANG ; Chao LIANG ; Hao LIU ; Yang YU ; Zhenzhou XU ; Shuang LIU ; Jingen WANG ; Linghua JIA ; Xin YAO ; Wenfeng LIAO ; Cheng FU ; Zhaohui TAN ; Guohua HE ; Guoxi ZHU ; Rui FAN ; Wenzeng YANG ; Xin CHEN ; Zhizhong LIU ; Liqiang ZHONG ; Benkang SHI ; Degang DING ; Shubo CHEN ; Junli WEI ; Xudong YAO ; Ming CHEN ; Zhanpeng LU ; Qun XIE ; Zhiquan HU ; Yinhuai WANG ; Hongqian GUO ; Tiwu FAN ; Zhaozhao LIANG ; Peng CHEN ; Wei WANG ; Tao XU ; Chunsheng LI ; Jinchun XING ; Hong LIAO ; Dalin HE ; Zhibin WU ; Jiandi YU ; Zhongwen FENG ; Mengxiang YANG ; Qifeng DOU ; Quan ZENG ; Yuanwei LI ; Xin GOU ; Guangchen ZHOU ; Xiaofeng WANG ; Rujian ZHU ; Zhonghua ZHANG ; Bo ZHANG ; Wanlong TAN ; Xueling QU ; Hongliang SUN ; Tianyi GAN ; Dingwei YE
Chinese Medical Journal 2023;136(10):1207-1215
BACKGROUND:
LY01005 (Goserelin acetate sustained-release microsphere injection) is a modified gonadotropin-releasing hormone (GnRH) agonist injected monthly. This phase III trial study aimed to evaluated the efficacy and safety of LY01005 in Chinese patients with prostate cancer.
METHODS:
We conducted a randomized controlled, open-label, non-inferiority trial across 49 sites in China. This study included 290 patients with prostate cancer who received either LY01005 or goserelin implants every 28 days for three injections. The primary efficacy endpoints were the percentage of patients with testosterone suppression ≤50 ng/dL at day 29 and the cumulative probability of testosterone ≤50 ng/dL from day 29 to 85. Non-inferiority was prespecified at a margin of -10%. Secondary endpoints included significant castration (≤20 ng/dL), testosterone surge within 72 h following repeated dosing, and changes in luteinizing hormone, follicle-stimulating hormone, and prostate specific antigen levels.
RESULTS:
On day 29, in the LY01005 and goserelin implant groups, testosterone concentrations fell below medical-castration levels in 99.3% (142/143) and 100% (140/140) of patients, respectively, with a difference of -0.7% (95% confidence interval [CI], -3.9% to 2.0%) between the two groups. The cumulative probabilities of maintaining castration from days 29 to 85 were 99.3% and 97.8%, respectively, with a between-group difference of 1.5% (95% CI, -1.3% to 4.4%). Both results met the criterion for non-inferiority. Secondary endpoints were similar between groups. Both treatments were well-tolerated. LY01005 was associated with fewer injection-site reactions than the goserelin implant (0% vs . 1.4% [2/145]).
CONCLUSION:
LY01005 is as effective as goserelin implants in reducing testosterone to castration levels, with a similar safety profile.
TRIAL REGISTRATION
ClinicalTrials.gov, NCT04563936.
Humans
;
Male
;
Antineoplastic Agents, Hormonal/therapeutic use*
;
East Asian People
;
Gonadotropin-Releasing Hormone/agonists*
;
Goserelin/therapeutic use*
;
Prostate-Specific Antigen
;
Prostatic Neoplasms/drug therapy*
;
Testosterone
7.Predilection site and risk factor of second primary cancer: A pan-cancer analysis based on the SEER database.
Shan XIONG ; Hengrui LIANG ; Peng LIANG ; Xiuyu CAI ; Caichen LI ; Ran ZHONG ; Jianfu LI ; Bo CHENG ; Feng ZHU ; Limin OU ; Zisheng CHEN ; Yi ZHAO ; Hongsheng DENG ; Zhuxing CHEN ; Zhichao LIU ; Zhanhong XIE ; Feng LI ; Jianxing HE ; Wenhua LIANG
Chinese Medical Journal 2023;136(12):1500-1502
8.Safety and efficacy of the early administration of levosimendan in patients with acute non-ST-segment elevation myocardial infarction and elevated NT-proBNP levels: An Early Management Strategy of Acute Heart Failure (EMS-AHF).
Feng XU ; Yuan BIAN ; Guo Qiang ZHANG ; Lu Yao GAO ; Yu Fa LIU ; Tong Xiang LIU ; Gang LI ; Rui Xue SONG ; Li Jun SU ; Yan Ju ZHOU ; Jia Yu CUI ; Xian Liang YAN ; Fang Ming GUO ; Huan Yi ZHANG ; Qing Hui LI ; Min ZHAO ; Li Kun MA ; Bei An YOU ; Ge WANG ; Li KONG ; Jian Liang MA ; Xin Fu ZHOU ; Ze Long CHANG ; Zhen Yu TANG ; Dan Yu YU ; Kai CHENG ; Li XUE ; Xiao LI ; Jiao Jiao PANG ; Jia Li WANG ; Hai Tao ZHANG ; Xue Zhong YU ; Yu Guo CHEN
Chinese Journal of Internal Medicine 2023;62(4):374-383
Objectives: To investigated the safety and efficacy of treating patients with acute non-ST-segment elevation myocardial infarction (NSTEMI) and elevated levels of N-terminal pro-hormone B-type natriuretic peptide (NT-proBNP) with levosimendan within 24 hours of first medical contact (FMC). Methods: This multicenter, open-label, block-randomized controlled trial (NCT03189901) investigated the safety and efficacy of levosimendan as an early management strategy of acute heart failure (EMS-AHF) for patients with NSTEMI and high NT-proBNP levels. This study included 255 patients with NSTEMI and elevated NT-proBNP levels, including 142 males and 113 females with a median age of 65 (58-70) years, and were admitted in the emergency or outpatient departments at 14 medical centers in China between October 2017 and October 2021. The patients were randomly divided into a levosimendan group (n=129) and a control group (n=126). The primary outcome measure was NT-proBNP levels on day 3 of treatment and changes in the NT-proBNP levels from baseline on day 5 after randomization. The secondary outcome measures included the proportion of patients with more than 30% reduction in NT-proBNP levels from baseline, major adverse cardiovascular events (MACE) during hospitalization and at 6 months after hospitalization, safety during the treatment, and health economics indices. The measurement data parameters between groups were compared using the t-test or the non-parametric test. The count data parameters were compared between groups using the χ² test. Results: On day 3, the NT-proBNP levels in the levosimendan group were lower than the control group but were statistically insignificant [866 (455, 1 960) vs. 1 118 (459, 2 417) ng/L, Z=-1.25,P=0.21]. However, on day 5, changes in the NT-proBNP levels from baseline in the levosimendan group were significantly higher than the control group [67.6% (33.8%,82.5%)vs.54.8% (7.3%,77.9%), Z=-2.14, P=0.03]. There were no significant differences in the proportion of patients with more than 30% reduction in the NT-proBNP levels on day 5 between the levosimendan and the control groups [77.5% (100/129) vs. 69.0% (87/126), χ²=2.34, P=0.13]. Furthermore, incidences of MACE did not show any significant differences between the two groups during hospitalization [4.7% (6/129) vs. 7.1% (9/126), χ²=0.72, P=0.40] and at 6 months [14.7% (19/129) vs. 12.7% (16/126), χ²=0.22, P=0.64]. Four cardiac deaths were reported in the control group during hospitalization [0 (0/129) vs. 3.2% (4/126), P=0.06]. However, 6-month survival rates were comparable between the two groups (log-rank test, P=0.18). Moreover, adverse events or serious adverse events such as shock, ventricular fibrillation, and ventricular tachycardia were not reported in both the groups during levosimendan treatment (days 0-1). The total cost of hospitalization [34 591.00(15 527.46,59 324.80) vs. 37 144.65(16 066.90,63 919.00)yuan, Z=-0.26, P=0.80] and the total length of hospitalization [9 (8, 12) vs. 10 (7, 13) days, Z=0.72, P=0.72] were lower for patients in the levosimendan group compared to those in the control group, but did not show statistically significant differences. Conclusions: Early administration of levosimendan reduced NT-proBNP levels in NSTEMI patients with elevated NT-proBNP and did not increase the total cost and length of hospitalization, but did not significantly improve MACE during hospitalization or at 6 months.
Male
;
Female
;
Humans
;
Aged
;
Natriuretic Peptide, Brain
;
Simendan/therapeutic use*
;
Non-ST Elevated Myocardial Infarction
;
Heart Failure/drug therapy*
;
Peptide Fragments
;
Arrhythmias, Cardiac
;
Biomarkers
;
Prognosis
9.Anterolateral or Posteromedial Plate-Assisted Intramedullary Nailing for Fixation of Proximal Third Tibia Fractures: A Biomechanical Study
Yibo XU ; Yao LU ; Teng MA ; Cheng REN ; Ming LI ; Liang SUN ; Qiang HUANG ; Qian WANG ; Hanzhong XUE ; Zhong LI ; Kun ZHANG
Journal of Medical Biomechanics 2023;38(1):E104-E109
Objective To study the stability of plate-assisted intramedullary nailing for fixing proximal third tibiafractures, compare and observe biomechanical characteristics of anterolateral or posteromedial plate-assisted intramedullary nailing after fixation of proximal third tibia fractures. Methods Eight artificial tibia of 4th-generation sawbones were divided into two groups based on location of the assisted plate, namely, anterolateral plate group and posteromedial plate group, with 4 specimens in each group. Each two locking bolts were fixed to theintramedullary nail proximally and distally, and each three bicortical screws were fixed to the plate proximally and distally. The specimens were osteotomized with a 10-mm defect which located 0. 5 cm to the proximal locking bolt of intramedullary nail or 5-6 cm distally to the knee joint line, in order to simulate an AO/ OTA 41-A2 type proximal third tibia fracture after fixation of intramedullary nail. After osteotomy was finished, axial compression test, three point bending test, cyclic loading and overstress test were conducted by mechanical testing machine. The results of axial stiffness and three-point stiffness between two groups were compared and analyzed. Results Axial compression test showed that the average axial stiffness in posteromedial plate group was lower than that in anterolateral plate group, but no significantly statistical differences were found between the two groups. Three point bending test showed that the average bending stiffness in posteromedial plate group was significantly higher than that in anterolateral plate group when stimulating either varus stress (plate located at pressure side of the fracture, t = 3. 679, P<0. 05) or valgus stress (plate located at tension side of the fracture, t = 8. 975, P<0. 05). Conclusions Plate-assisted intramedullary nailing for fixation of proximal third tibia fractures can minimize the angulation malalignment, improve the stability of nailed proximal tibial fragment and allow the early weight bearing. Both anterolateral and posteromedial plate-assisted intramedullary nail can provide satisfactory axial stability for proximal third tibia fractures, while posteromedial plate-assisted intramedullary nail shows better bending stability than anterolateral plate in countering varus or valgus stress deformity. This study provides an essential basis for clinical decision making about plate-assisted intramedullary nailing for fixing proximal third tibia fractures.
10.Reinforced radiculoplasty for the treatment of symptomatic sacral Tarlov cysts: A clinical analysis of 71 cases.
Chao WU ; Bin LIU ; Jing Cheng XIE ; Zhen Yu WANG ; Chang Cheng MA ; Jun YANG ; Jian Jun SUN ; Xiao Dong CHEN ; Tao YU ; Guo Zhong LIN ; Yu SI ; Yun Feng HAN ; Su Hua CHEN ; Xiao Liang YIN ; Qian Quan MA ; Mu Tian ZHENG ; Lin ZENG
Journal of Peking University(Health Sciences) 2023;55(1):133-138
OBJECTIVE:
To investigate the safety and efficacy of reinforced radiculoplasty in the treatment of symptomatic sacral Tarlov cysts (TCs).
METHODS:
A retrospective analysis was performed on the clinical data and follow-up data of 71 patients with symptomatic sacral TCs who underwent reinforced radiculoplasty in the Neurosurgery Department of Peking University Third Hospital from June 2018 to March 2021. All the operations were performed under neuroelectrophysiological monitoring. Intraoperative cyst exploration, partial resection of the cyst wall, narrowing of the leak, nerve root sleeve radiculoplasty and artificial dural reinforcement were performed. The incidence of postoperative complications and new neurological dysfunction was analyzed. Visual analogue scale (VAS) was used to assess the changes of pain before and after surgery. The Japanese Orthopedics Association (JOA) low back pain score was used to evaluate the changes in nerve function before and after surgery.
RESULTS:
In the study, 71 patients had 101 TCs, 19 (18.8%) TCs originated from the left S1 nerve, 26 (25.7%) originated from the left S2 nerve, 3 (3.0%) originated from the left S3 nerve, 14 (13.9%) originated from the right S1 nerve, 33 (32.7%) originated from the right S2 nerve, 6 (5.9%) originated from the right S3 nerve, all the TCs underwent reinforced radiculoplasty. Deep infection (1 case), subcutaneous effusion (1 case), fat li-quefaction (1 case) and urinary tract infection (4 cases) were recorded postoperatively. The patients were followed up for 12-43 months (median, 26 months). Two cases had new urinary retention after operation, and the catheter was removed at the end of the first and second months respectively. One case had new fecal weakness, which improved after 3 months. Compared with preoperation, VAS decreased significantly at the last follow-up [median, 6 (4-9) vs. 1 (0-5), Z=-7.272, P < 0.001], JOA score increased significantly [median, 20 (16-25) vs. 27 (18-29), Z=-7.265, P < 0.001]. There were 18 cured cases (25.4%), 41 excellent cases (57.7%), 8 effective cases (11.3%), and 4 invalid cases (5.6%). The total efficiency was 94.4% (67/71). Two (1.98%) cysts recurred.
CONCLUSION
For patients with symptomatic sacral TCs, reinforced radiculoplasty can significantly improve the pain and nerve function, which is safe and reliable.
Humans
;
Tarlov Cysts/epidemiology*
;
Retrospective Studies
;
Neoplasm Recurrence, Local/complications*
;
Cysts/surgery*
;
Pain

Result Analysis
Print
Save
E-mail