1.Safety and Efficacy of Radiofrequency Ablation for Superficial Parotid Pleomorphic Adenoma
Chih-Ying LEE ; Wei-Che LIN ; Sheng-Dean LUO ; Pi-Ling CHIANG ; An-Ni LIN ; Cheng-Kang WANG ; Chun-Yuan CHAO
Korean Journal of Radiology 2025;26(5):460-470
Objective:
To retrospectively compare the safety and efficacy of ultrasound-guided radiofrequency ablation (RFA) with parotidectomy for superficial pleomorphic adenoma (PA).
Materials and Methods:
From March 2022 to October 2023, 88 patients diagnosed with superficial parotid PA underwent either RFA (n = 12; mean age, 47.1 years) or parotidectomy (n = 76; mean age, 47.8 years). Patients in the RFA group were matched to those in the surgery group in a 1:1 ratio using propensity scores based on age, sex, tumor volume, diameter, location, and comorbidities. Ultrasound characteristics, cosmetic scores (0–4), numerical rating scale scores (0–10), and complications were assessed before the procedures and at 1-, 3-, and 6-month follow-ups. Outcomes were compared between baseline and follow-up in the RFA group and between the RFA and surgery groups.
Results:
In the RFA group, significant reductions in tumor volume were observed between baseline (median, 2.02 cm 3 ) and the 1-month follow-up (median, 1.21 cm 3 ; P = 0.015), between the 1-month and 3-month follow-ups (median, 0.53 cm 3 ; P= 0.002), and between the 3- and 6-month follow-ups (median, 0.23 cm 3 ; P = 0.003). The volume reduction ratios at 1, 3, and 6 months were 39.7%, 79.9%, and 88.0%, respectively. The cosmetic score was significantly lower at 3- and 6-month followup compared to baseline (median 1 and 1 vs. 4, P = 0.04). The numerical rating scale scores did not differ significantly from baseline throughout follow-up. In the propensity score-matched analysis (12 patients per group), RFA was associated with a shorter median procedure time (61.5 vs. 253.3 minutes; P < 0.001), shorter hospital stay (0 vs. 4 days; P < 0.001), and lower cost (1859.9 vs. 3512.4 USD; P < 0.001) than parotidectomy, with no significant difference in overall complication rates (33.3% [4/12] vs. 41.7% [5/12]; P = 1.000).
Conclusion
RFA may be a safe and effective alternative to surgery for superficial parotid PA, offering a shorter median procedure time, shorter hospital stay, and lower costs.
2.Effect of Serum Containing Zhenwutang on Apoptosis of Myocardial Mast Cells and Mitochondrial Autophagy
Wei TANG ; Meiqun ZHENG ; Xiaolin WANG ; Zhiyong CHEN ; Chi CHE ; Zongqiong LU ; Jiashuai GUO ; Xiaomei ZOU ; Lili XU ; Lin LI
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(3):11-21
ObjectiveTo explore the effect of serum containing Zhenwutang on myocardial mast cell apoptosis induced by angiotensin Ⅱ (AngⅡ) and the mechanism of the correlation between apoptosis and mitochondrial autophagy. MethodsIn this experiment, AngⅡ and serum containing Zhenwutang with different concentrations were used to interfere with H9C2 cardiomyocytes for 24 h, and the survival rate of H9C2 cardiomyocytes was detected by cell counting kit-8 (CCK-8) to screen the optimal concentration for the experiment. Enzyme-linked immunosorbent assay (ELISA) was used to detect the content of B-type natriuretic peptide (BNP) in cell culture supernatant, and immunofluorescence was used to detect the cell surface area to verify the construction of the myocardial mast cell model. Subsequently, the experiment was divided into a blank group (20% blank serum), a model group (20% blank serum + 5×10-5 mol·L-1 AngⅡ), low-, medium-, and high-dose (5%, 10% and 20%) serum containing Zhenwutang groups, an autophagy inhibitor group (1×10-4 mol·L-1 3-MA), and autophagy inducer group (1×10-7 mol·L-1 rapamycin). The apoptosis level of H9C2 cells and the changes of mitochondrial membrane potential were detected by flow cytometry. The lysosomal probe (Lyso Tracker) and mitochondrial probe (Mito Tracker) co-localization was employed to detect autophagy. Real-time fluorescence quantitative polymerase chain reaction (Real-time PCR) was used to detect Caspase-3, Caspase-9, B-cell lymphoma 2 (Bcl-2), Bcl-2-related X protein (Bax), and cytochrome C (Cyt C) in apoptosis-related pathways and the relative mRNA expression of ubiquitin ligase (Parkin), phosphatase and tensin homolog (PTEN)-induced kinase 1 (PINK1), and p62 protein in mitochondrial autophagy-related pathways. Western blot was used to detect cleaved Caspase-3, cleaved Caspase-9, Bax, Bcl-2, and Cyt C in apoptosis-related pathways, phosphorylated ubiquitin ligase (p-Parkin), phosphorylated PTEN-induced kinase 1 (p-PINK1), p62, and Bcl-2 homology domain protein Beclin1 in mitochondrial autophagy-related pathways, and the change of microtubule-associated protein 1 light chain 3 (LC3) Ⅱ/Ⅰ ratio. ResultsCCK-8 showed that when the concentration of AngⅡ was 5×10-5 mol·L-1, the cell activity was the lowest, and there was no cytotoxicity. At this concentration, the surface area of cardiomyocytes was significantly increased (P<0.01), and the content of BNP in the supernatant of culture medium was significantly increased (P<0.05). Therefore, AngⅡ with a concentration of 5×10-5 mol·L-1 was selected for the subsequent modeling of myocardial mast cells. Compared with the blank group, the model group and the autophagy inhibitor 3-MA group had a significantly increased apoptosis rate (P<0.01) and significantly decreased mitochondrial membrane potential (P<0.01). The results of immunofluorescence co-localization showed that compared with the blank group, the model group had a significantly decreased number of red and green fluorescence spots. The results of Real-time PCR showed that compared with that in the blank group, the relative mRNA expression of Bax, Caspase-3, Caspase-9, Cyt C, and p62 in the model group was significantly up-regulated (P<0.01), while the relative mRNA expression of Bcl-2, Parkin, and PINK1 was significantly down-regulated (P<0.01). In addition, the relative protein expression of Bax, cleaved Caspase-3, cleaved Caspase-9, Cyt C, and p62 was significantly up-regulated (P<0.01). The LC3Ⅱ/Ⅰ was significantly decreased, and the relative protein expression of Bcl-2, p-Parkin, p-PINK1, and Beclin1 was significantly down-regulated (P<0.01). Compared with the model group, the serum containing Zhenwutang groups and the autophagy inducer group had significantly decreased apoptosis rate (P<0.01), and the decrease ratio of mitochondrial membrane potential is significantly lowered (P<0.01) in a dose-dependent manner. Additionally, both red and green fluorescence spots became more in these groups. In the 3-MA group, the number of red and green fluorescence spots decreased significantly. The relative mRNA expression of Bax, Caspase-3, Caspase-9, Cyt C, and p62 was significantly down-regulated (P<0.05, P<0.01), while that of Bcl-2, Parkin, and PINK1 was significantly up-regulated (P<0.01). In the serum containing Zhenwutang groups, the relative protein expression levels of Bax, cleaved Caspase-3, cleaved Caspase-9, Cyt C, and p62 were significantly down-regulated (P<0.05,P<0.01). The LC3Ⅱ/Ⅰ was significantly increased, and the relative protein expression levels of Bcl-2, p-Parkin, p-PINK1, and Beclin1 were significantly up-regulated (P<0.01). ConclusionThe serum containing Zhenwutang can reduce the apoptosis of myocardial mast cells and increase mitochondrial autophagy. This is related to the inhibition of intracellular Bax/Bcl-2/Caspase-3 apoptosis pathway and regulation of Parkin/PINK1 mitochondrial autophagy pathway.
3.Evaluation of efficacy of two medical cleaner on the pre-cleaning dental zinc phosphate cement filler
Yingjia LIN ; Yi QIAO ; Fenglian CHE
Chongqing Medicine 2025;54(8):1883-1887,1893
Objective To compare the efficacy of alkaline enzyme-containing versus multi-enzyme cleaner for pre-cleaning dental zinc phosphate cement fillers.Methods One hundred new dental cement fillers were selected and contaminated to moderate-to-heavy levels by simulating clinical contamination,and divided into the alkaline enzyme-containing group and the multi-enzyme group,with 50 cases in each group.The two groups underwent manual brushing followed by automated spray-type washer-disinfector cleaning.The effica-cy of the two groups of pre-cleaning were evaluated by naked-eye visual detection,10×illuminated magnifica-tion and residual protein quantification.Results The alkaline enzyme-containing group demonstrated signifi-cantly higher pass rates than the multi-enzyme group by naked-eye visual detection and 10×illuminated mag-nification(P<0.05),while there was no statistically significant difference in the residual protein quantifica-tion between the two groups(P>0.05).The qualified cleaning rates of the three parts of the instruments in the alkaline enzyme-containing group were all higher than those in the multi-enzyme group,but only the quali-fied cleaning rate of the handle threaded surface was statistically significant(P<0.05).There was no statisti-cally significant difference in the cleaning qualification rates of the instruments three parts of the alkaline en-zyme-containing group(P>0.05),while there was statistically significant difference in the cleaning qualifica-tion rates of the instruments three parts of the multi-enzyme group(P<0.05).Conclusion Compared with the multi-enzyme cleaner,alkaline enzyme-containing cleaner has better effects in the pre-cleaning of zinc phosphate cement fillers.
4.Safety and Efficacy of Radiofrequency Ablation for Superficial Parotid Pleomorphic Adenoma
Chih-Ying LEE ; Wei-Che LIN ; Sheng-Dean LUO ; Pi-Ling CHIANG ; An-Ni LIN ; Cheng-Kang WANG ; Chun-Yuan CHAO
Korean Journal of Radiology 2025;26(5):460-470
Objective:
To retrospectively compare the safety and efficacy of ultrasound-guided radiofrequency ablation (RFA) with parotidectomy for superficial pleomorphic adenoma (PA).
Materials and Methods:
From March 2022 to October 2023, 88 patients diagnosed with superficial parotid PA underwent either RFA (n = 12; mean age, 47.1 years) or parotidectomy (n = 76; mean age, 47.8 years). Patients in the RFA group were matched to those in the surgery group in a 1:1 ratio using propensity scores based on age, sex, tumor volume, diameter, location, and comorbidities. Ultrasound characteristics, cosmetic scores (0–4), numerical rating scale scores (0–10), and complications were assessed before the procedures and at 1-, 3-, and 6-month follow-ups. Outcomes were compared between baseline and follow-up in the RFA group and between the RFA and surgery groups.
Results:
In the RFA group, significant reductions in tumor volume were observed between baseline (median, 2.02 cm 3 ) and the 1-month follow-up (median, 1.21 cm 3 ; P = 0.015), between the 1-month and 3-month follow-ups (median, 0.53 cm 3 ; P= 0.002), and between the 3- and 6-month follow-ups (median, 0.23 cm 3 ; P = 0.003). The volume reduction ratios at 1, 3, and 6 months were 39.7%, 79.9%, and 88.0%, respectively. The cosmetic score was significantly lower at 3- and 6-month followup compared to baseline (median 1 and 1 vs. 4, P = 0.04). The numerical rating scale scores did not differ significantly from baseline throughout follow-up. In the propensity score-matched analysis (12 patients per group), RFA was associated with a shorter median procedure time (61.5 vs. 253.3 minutes; P < 0.001), shorter hospital stay (0 vs. 4 days; P < 0.001), and lower cost (1859.9 vs. 3512.4 USD; P < 0.001) than parotidectomy, with no significant difference in overall complication rates (33.3% [4/12] vs. 41.7% [5/12]; P = 1.000).
Conclusion
RFA may be a safe and effective alternative to surgery for superficial parotid PA, offering a shorter median procedure time, shorter hospital stay, and lower costs.
5.Therapeutic strategies targeting CD47-SIRPα signaling pathway in gastrointestinal cancers treatment.
Zhengping CHE ; Wei WANG ; Lin ZHANG ; Zhenghong LIN
Journal of Pharmaceutical Analysis 2025;15(1):101099-101099
Gastrointestinal (GI) cancers are prevalent globally, with leading incidence and mortality rates among malignant tumors. Despite notable advancements in surgical resection, radiotherapy, and chemotherapy, the overall survival rates remain low. Hence, it is imperative to explore alternative approaches that enhance patient outcomes. Cluster of differentiation 47 (CD47), serving as an early diagnostic marker, is predominantly overexpressed in GI cancers and associated with poor prognosis. Targeting the CD47-signal regulatory protein alpha (SIRPα) signaling pathway may provide a novel strategy for GI cancers treatment. This study summarizes current knowledge of the structure and function of CD47 and SIRPα, their roles in signaling pathways, the prognostic significance of CD47, therapeutic strategies targeting the CD47-SIRPα signaling pathway in GI cancer, and highlights key issues for future investigations.
6.Safety and Efficacy of Radiofrequency Ablation for Superficial Parotid Pleomorphic Adenoma
Chih-Ying LEE ; Wei-Che LIN ; Sheng-Dean LUO ; Pi-Ling CHIANG ; An-Ni LIN ; Cheng-Kang WANG ; Chun-Yuan CHAO
Korean Journal of Radiology 2025;26(5):460-470
Objective:
To retrospectively compare the safety and efficacy of ultrasound-guided radiofrequency ablation (RFA) with parotidectomy for superficial pleomorphic adenoma (PA).
Materials and Methods:
From March 2022 to October 2023, 88 patients diagnosed with superficial parotid PA underwent either RFA (n = 12; mean age, 47.1 years) or parotidectomy (n = 76; mean age, 47.8 years). Patients in the RFA group were matched to those in the surgery group in a 1:1 ratio using propensity scores based on age, sex, tumor volume, diameter, location, and comorbidities. Ultrasound characteristics, cosmetic scores (0–4), numerical rating scale scores (0–10), and complications were assessed before the procedures and at 1-, 3-, and 6-month follow-ups. Outcomes were compared between baseline and follow-up in the RFA group and between the RFA and surgery groups.
Results:
In the RFA group, significant reductions in tumor volume were observed between baseline (median, 2.02 cm 3 ) and the 1-month follow-up (median, 1.21 cm 3 ; P = 0.015), between the 1-month and 3-month follow-ups (median, 0.53 cm 3 ; P= 0.002), and between the 3- and 6-month follow-ups (median, 0.23 cm 3 ; P = 0.003). The volume reduction ratios at 1, 3, and 6 months were 39.7%, 79.9%, and 88.0%, respectively. The cosmetic score was significantly lower at 3- and 6-month followup compared to baseline (median 1 and 1 vs. 4, P = 0.04). The numerical rating scale scores did not differ significantly from baseline throughout follow-up. In the propensity score-matched analysis (12 patients per group), RFA was associated with a shorter median procedure time (61.5 vs. 253.3 minutes; P < 0.001), shorter hospital stay (0 vs. 4 days; P < 0.001), and lower cost (1859.9 vs. 3512.4 USD; P < 0.001) than parotidectomy, with no significant difference in overall complication rates (33.3% [4/12] vs. 41.7% [5/12]; P = 1.000).
Conclusion
RFA may be a safe and effective alternative to surgery for superficial parotid PA, offering a shorter median procedure time, shorter hospital stay, and lower costs.
7.Safety and Efficacy of Radiofrequency Ablation for Superficial Parotid Pleomorphic Adenoma
Chih-Ying LEE ; Wei-Che LIN ; Sheng-Dean LUO ; Pi-Ling CHIANG ; An-Ni LIN ; Cheng-Kang WANG ; Chun-Yuan CHAO
Korean Journal of Radiology 2025;26(5):460-470
Objective:
To retrospectively compare the safety and efficacy of ultrasound-guided radiofrequency ablation (RFA) with parotidectomy for superficial pleomorphic adenoma (PA).
Materials and Methods:
From March 2022 to October 2023, 88 patients diagnosed with superficial parotid PA underwent either RFA (n = 12; mean age, 47.1 years) or parotidectomy (n = 76; mean age, 47.8 years). Patients in the RFA group were matched to those in the surgery group in a 1:1 ratio using propensity scores based on age, sex, tumor volume, diameter, location, and comorbidities. Ultrasound characteristics, cosmetic scores (0–4), numerical rating scale scores (0–10), and complications were assessed before the procedures and at 1-, 3-, and 6-month follow-ups. Outcomes were compared between baseline and follow-up in the RFA group and between the RFA and surgery groups.
Results:
In the RFA group, significant reductions in tumor volume were observed between baseline (median, 2.02 cm 3 ) and the 1-month follow-up (median, 1.21 cm 3 ; P = 0.015), between the 1-month and 3-month follow-ups (median, 0.53 cm 3 ; P= 0.002), and between the 3- and 6-month follow-ups (median, 0.23 cm 3 ; P = 0.003). The volume reduction ratios at 1, 3, and 6 months were 39.7%, 79.9%, and 88.0%, respectively. The cosmetic score was significantly lower at 3- and 6-month followup compared to baseline (median 1 and 1 vs. 4, P = 0.04). The numerical rating scale scores did not differ significantly from baseline throughout follow-up. In the propensity score-matched analysis (12 patients per group), RFA was associated with a shorter median procedure time (61.5 vs. 253.3 minutes; P < 0.001), shorter hospital stay (0 vs. 4 days; P < 0.001), and lower cost (1859.9 vs. 3512.4 USD; P < 0.001) than parotidectomy, with no significant difference in overall complication rates (33.3% [4/12] vs. 41.7% [5/12]; P = 1.000).
Conclusion
RFA may be a safe and effective alternative to surgery for superficial parotid PA, offering a shorter median procedure time, shorter hospital stay, and lower costs.
8.Association of Rapidly Elevated Plasma Tau Protein With Cognitive Decline in Patients With Amnestic Mild Cognitive Impairment and Alzheimer’s Disease
Che-Sheng CHU ; Yu-Kai LIN ; Chia-Lin TSAI ; Yueh-Feng SUNG ; Chia-Kuang TSAI ; Guan-Yu LIN ; Chien-An KO ; Yi LIU ; Chih-Sung LIANG ; Fu-Chi YANG
Psychiatry Investigation 2025;22(2):130-139
Objective:
Whether elevation in plasma levels of amyloid and tau protein biomarkers are better indicators of cognitive decline than higher baseline levels in patients with amnestic mild cognitive impairment (aMCI) and Alzheimer’s disease (AD) remains understudied.
Methods:
We included 67 participants with twice testing for AD-related plasma biomarkers via immunomagnetic reduction (IMR) assays (amyloid beta [Aβ]1-40, Aβ1-42, total tau [t-Tau], phosphorylated tau [p-Tau] 181, and alpha-synuclein [α-Syn]) and the Mini-Mental State Examination (MMSE) over a 1-year interval. We examined the correlation between biomarker levels (baseline vs. longitudinal change) and annual changes in the MMSE scores. Receiver operating characteristic curve analysis was conducted to compare the biomarkers.
Results:
After adjustment, faster cognitive decline was correlated with lower baseline levels of t-Tau (β=0.332, p=0.030) and p-Tau 181 (β=0.369, p=0.015) and rapid elevation of t-Tau (β=-0.330, p=0.030) and p-Tau 181 levels (β=-0.431, p=0.004). However, the levels (baseline and longitudinal changes) of Aβ1-40, Aβ1-42, and α-Syn were not correlated with cognitive decline. aMCI converters had lower baseline levels of p-Tau 181 (p=0.002) but larger annual changes (p=0.001) than aMCI non-converters. The change in p-Tau 181 levels showed better discriminatory capacity than the change in t-Tau levels in terms of identifying AD conversion in patients with aMCI, with an area under curve of 86.7% versus 72.2%.
Conclusion
We found changes in p-Tau 181 levels may be a suitable biomarker for identifying AD conversion.
10.Association of Rapidly Elevated Plasma Tau Protein With Cognitive Decline in Patients With Amnestic Mild Cognitive Impairment and Alzheimer’s Disease
Che-Sheng CHU ; Yu-Kai LIN ; Chia-Lin TSAI ; Yueh-Feng SUNG ; Chia-Kuang TSAI ; Guan-Yu LIN ; Chien-An KO ; Yi LIU ; Chih-Sung LIANG ; Fu-Chi YANG
Psychiatry Investigation 2025;22(2):130-139
Objective:
Whether elevation in plasma levels of amyloid and tau protein biomarkers are better indicators of cognitive decline than higher baseline levels in patients with amnestic mild cognitive impairment (aMCI) and Alzheimer’s disease (AD) remains understudied.
Methods:
We included 67 participants with twice testing for AD-related plasma biomarkers via immunomagnetic reduction (IMR) assays (amyloid beta [Aβ]1-40, Aβ1-42, total tau [t-Tau], phosphorylated tau [p-Tau] 181, and alpha-synuclein [α-Syn]) and the Mini-Mental State Examination (MMSE) over a 1-year interval. We examined the correlation between biomarker levels (baseline vs. longitudinal change) and annual changes in the MMSE scores. Receiver operating characteristic curve analysis was conducted to compare the biomarkers.
Results:
After adjustment, faster cognitive decline was correlated with lower baseline levels of t-Tau (β=0.332, p=0.030) and p-Tau 181 (β=0.369, p=0.015) and rapid elevation of t-Tau (β=-0.330, p=0.030) and p-Tau 181 levels (β=-0.431, p=0.004). However, the levels (baseline and longitudinal changes) of Aβ1-40, Aβ1-42, and α-Syn were not correlated with cognitive decline. aMCI converters had lower baseline levels of p-Tau 181 (p=0.002) but larger annual changes (p=0.001) than aMCI non-converters. The change in p-Tau 181 levels showed better discriminatory capacity than the change in t-Tau levels in terms of identifying AD conversion in patients with aMCI, with an area under curve of 86.7% versus 72.2%.
Conclusion
We found changes in p-Tau 181 levels may be a suitable biomarker for identifying AD conversion.

Result Analysis
Print
Save
E-mail