1.Best essential surgical technique training course to improve surgical residents′ laparoscopic peritoneal suturing skills: a cohort study
Zhenghao CAI ; Haiqin SONG ; Jing SUN ; Pei XUE ; Luyang ZHANG ; Chao WU ; Hiju HONG ; Xi CHENG ; Sen ZHANG ; Minhua ZHENG ; Lu ZANG ; Ruijun PAN ; Jianwen LI ; Bo FENG
Journal of Surgery Concepts & Practice 2025;30(2):132-137
Objective To explore the effectiveness of an integrated laparoscopic simulation training course (best essential surgical technique training, BEST) in enhancing laparoscopic peritoneal suturing techniques in surgical residents.Methods As an integrated two-stage program, the BEST course applied basic laparoscopic training system with simple molds in phase Ⅰ training, and then adopted advanced laparoscopic training system, 3D Laparoscope and ex-vivo animal models in phase Ⅱ training. The laparoscopic suturing techniques were practiced in phase Ⅱ training. From August 2021 to July 2024, surgical residents in the second year of the national standardized training program were divided into pilot and control groups based on whether they had undergone the BEST course. Two cases of laparoscopic peritoneal suture were performed by the surgical residents under supervision in the department of gastrointestinal surgery. The operative time, quality of suture, and independent completion rate were compared between the two groups.Results A total of 33 surgical residents (19 in pilot group and 14 in control group) were included in this study, and a total of 66 cases of laparoscopic peritoneal suture were performed (38 in pilot group and 28 in control group). The operative time was significantly shorter in pilot group than that in control group (15.7 min vs. 17.5 min, P=0.025). The quality of suture was significantly better in pilot group compared to control group (P=0.023). In pilot group, all peritoneal sutures were performed by residents independently, whereas in control group, 3 cases (10.7%) were assisted by the supervisor, and the independent completion rate was different significantly (P=0.039).Conclusions The BEST course can help improve surgical residents′ laparoscopic peritoneal suturing techniques and could be promoted in the national standardized training program for surgical residents.
2.Creatine regulating neuronal ferroptosis by reducing STAT1-SOCS1 signaling activation in Alzheimer's disease model mice
Xiang-Qi SHAO ; Xue WANG ; Tao WANG ; Bo YUAN ; Wen-Ying QIU ; Fan LIU ; Chao MA
Acta Anatomica Sinica 2025;56(3):253-259
Objective To explore whether creatine therapy regulates neuronal ferroptosis by inhibiting the activation of STAT1 signaling pathway associated with suppressor of cytokine signaling 1(SOCS1)in Alzheimer's disease.Methods Immunohistochemical staining and counting of positive results using paraffin sections of human brain frontal lobes were employed to determine the trend of changes in the target proteins.Further validation was performed by immunofluorescence and Western blotting.STAT1 phosphorylation was inhibited by creatine injection using eleven FAD4T mice and by cerebellar medullary pool puncture,and the expression of target proteins was examined by immunohistochemistry and immunofluorescence after postmortem sampling.Results Compared with the age controls,interferon-γ(IFN-γ),an activating cytokine of the STAT1 signaling pathway,and SOCS1,a negative regulator of STAT1 activation,were both significantly up-regulated,STAT1 phosphorylation was enhanced,and the ferroptosis markers ferritin light chain(FTL)and cystine/glutamate transporter(xCT)increased markedly in the cortex of AD human brains;Creatine treatment of FAD4T mice resulted in a reduction of both IFN-γ and SOCS1,and a significant decrease in the ferroptosis markers FTL and xCT(SLC7A11).Conclusion Creatine ameliorates neuronal ferroptosis in AD model mice by reducing neuronal STAT1-SOCS1 signalling activation.
3.Impact of inhaled corticosteroid use on elderly chronic pulmonary disease patients with community acquired pneumonia.
Xiudi HAN ; Hong WANG ; Liang CHEN ; Yimin WANG ; Hui LI ; Fei ZHOU ; Xiqian XING ; Chunxiao ZHANG ; Lijun SUO ; Jinxiang WANG ; Guohua YU ; Guangqiang WANG ; Xuexin YAO ; Hongxia YU ; Lei WANG ; Meng LIU ; Chunxue XUE ; Bo LIU ; Xiaoli ZHU ; Yanli LI ; Ying XIAO ; Xiaojing CUI ; Lijuan LI ; Xuedong LIU ; Bin CAO
Chinese Medical Journal 2024;137(2):241-243
4.Quality evaluation for Beidougen Formula Granules
Gui-Yun CAO ; Xue-Song ZHUANG ; Bo NING ; Yong-Qiang LIN ; Dai-Jie WANG ; Wei-Liang CUI ; Hong-Chao LIU ; Xiao-Di DONG ; Meng-Meng HUANG ; Zhao-Qing MENG
Chinese Traditional Patent Medicine 2024;46(3):717-723
AIM To evaluate the quality of Beidougen Formula Granules.METHODS Fifteen batches of standard decoctions and three batches of formula granules were prepared,after which paste rate and contents,transfer rates of magnoflorine,daurisoline,dauricine were determined.HPLC specific chromatograms were established,and cluster analysis was adopted in chemical pattern recognition.RESULTS For three batches of formula granules,the paste rates were 15.1%-16.6%,the contents of magnoflorine,daurisoline,dauricine were 18.93-19.39,9.42-9.60,6.79-6.85 mg/g with the transfer rates of 34.42%-35.25%,43.81%-44.65%,27.27%-27.51%from decoction pieces to formula granules,respectively,and there were seven characteristic peaks in the specific chromatograms with the similarities of more than 0.95,which demonstrated good consistence with those of standard decoctions and accorded with related limit requirements.Fifteen batches of standard decoctions were clustered into two types,and the medicinal materials produced from Jilin,Hebei,Shangdong could be used for the preparation of formula granules.CONCLUSION This reasonable and reliable method can provide references for the quality control and clinical application of Beidougen Formula Granules.
5.Percutaneous balloon mitral valvuloplasty guided by intracardiac echocardiography:a report of two cases
De-Jian LI ; Song CHEN ; Chao XU ; Xue JIANG ; Bo WANG ; Jian-Fei FENG ; Dong-Bang SONG ; Guo-Hui ZHANG ; Ming-Quan WANG ; Wei-Min WANG ; Da-Dong ZHANG
Chinese Journal of Interventional Cardiology 2024;32(5):295-297
For the past 30 years,percutaneous balloon mitral valve dilatation has been performed under the guidance of X-rays and bedside ultrasound.However,there are still some cases of mitral valve stenosis in the large atrium where balloon dilation failed.Intraperitoneal ultrasound-guided percutaneous balloon mitral valve plasty is accurate and feasible,which can reduce the occurrence of complications and improve the success rate of such elderly complex cases.Two patients with severe mitral stenosis underwent percutaneous balloon mitral valve plasty guided by intracardiac ultrasound.The operations were successful without any complications,which can provide reference for clinical treatment of mitral stenosis.
6.Identification and Expression Analysis of AP2/ERF Family in Stress Responses of Pinellia ternata Based on Transcriptome Data
Jinrong YANG ; Wanning CUI ; Yu ZHANG ; Chen BO ; Qiujie CHAO ; Yanfang ZHU ; Yongbo DUAN ; Tao XUE ; Aimin ZHANG
Chinese Journal of Experimental Traditional Medical Formulae 2023;29(5):176-184
ObjectiveTo identify the functions of the AP2/ERF family members in Pinellia ternata and promote the genetic improvement of P. ternata varieties. MethodWe identified and conducted a systematic bioinformatics analysis of the AP2/ERF family member genes in P. ternata based on the three generations of transcriptome data. Real-time polymerase Chain reaction (Real-time) PCR was employed to determine the expression pattern of AP2/ERF genes in different tissues and under different stress conditions. ResultA total of eight full-length AP2/ERF family members were identified from the transcriptome data, which were classified into three sub-gene families: AP2, ERF, and DREB. The deduced AP2/ERF proteins in P. ternata had the length of 251-512 aa, the theoretical pI of 5.29-11.72, the instability index of 45.90-82.41, subcellular localization in the nucleus, and conserved domains and motifs. AP2/ERF genes were expressed in different tissues of P. ternata, with high expression levels in the leaf. The stress response experiments showed that PtERF1 mainly responded to NaCl stress. The expression of PtERF2 and PtERF4 was significantly up-regulated under low temperature and polyethylene glycol (PEG)-simulated stress. PtERF3 responded to both low temperature and NaCl stress. The expression of PtERF5 was induced by high temperature, low temperature, NaCl and PEG stress. The expression of PtERF7 was up-regulated under high temperature, while that of PtERF8 under low temperature. ConclusionThe AP2/ERF genes in P. ternata can respond to stress and have the potential functions of regulating photosynthesis and improving root stress resistance.
7.Value of direct immunohistochemical staining in assisting intraoperative frozen diagnosis of bronchiolar adenoma.
Bo ZHENG ; Shuan Mei ZOU ; Lin YANG ; Xue Min XUE ; Chang Yuan GUO ; Long WANG ; Wen Chao LIU ; Zhao Zhao ZHOU ; Xin LIU ; Li Yan XUE
Chinese Journal of Pathology 2023;52(2):142-146
Objective: To explore the feasibility and application value of intraoperative direct immunohistochemical (IHC) staining in improving the diagnosis accuracy in difficult cases of bronchiolar adenoma (BA). Methods: Nineteen cases with single or multiple pulmonary ground-glass nodules or solid nodules indicated by imaging in Cancer Hospital of Chinese Academy of Medical Sciences from January to July 2021 and with difficulty in differential diagnosis at frozen HE sections were selected. In the experimental group, direct IHC staining of cytokeratin 5/6 (CK5/6) and p63 was performed on frozen sections to assist the differentiation of BA from in situ/micro-invasive adenocarcinoma/adenocarcinoma/invasive mucinous adenocarcinoma. In the control group, two pathologists performed routine frozen HE section diagnosis on these 19 cases. The diagnostic results of paraffin sections were used as the gold standard. The sensitivity and specificity of BA diagnosis, consistency with paraffin diagnosis and time used for frozen diagnosis were compared between the experimental group and the control group. Results: The basal cells of BA were highlighted by CK5/6 and p63 staining. There were no basal cells in the in situ/microinvasive adenocarcinoma/adenocarcinoma/invasive mucinous adenocarcinoma. In the experimental group, the sensitivity and specificity with aid of direct IHC staining for BA were 100% and 86.7%, respectively, and the Kappa value of frozen and paraffin diagnosis was 0.732, and these were significantly higher than those in the control group (P<0.05). The average time consumption in the experimental group (32.4 min) was only 7 min longer than that in the control group (25.4 min). Conclusions: Direct IHC staining can improve the accuracy of BA diagnosis intraoperatively and reduce the risk of misdiagnosis, but require significantly longer time. Thus frozen direct IHC staining should be restricted to cases with difficulty in differentiating benign from malignant diseases, especially when the surgical modalities differ based on the frozen diagnosis.
Humans
;
Paraffin
;
Sensitivity and Specificity
;
Adenocarcinoma in Situ
;
Adenoma/diagnosis*
;
Adenocarcinoma, Mucinous/surgery*
;
Frozen Sections/methods*
8.Association between semen collection time and semen parameters: an observational study.
Shun BAI ; Xian-Chao DOU ; Hao-Lin QI ; Yan-Song ZHU ; Yin-Tao ZHANG ; Yi-Xun LIU ; Xue-Chun HU ; Cheng CAO ; Xian-Hong TONG ; Bo XU ; Li-Min WU ; Xiao-Hua JIANG
Asian Journal of Andrology 2023;25(3):339-344
The process of semen collection plays a key role in the quality of semen specimens. However, the association between semen collection time and semen quality is still unclear. In this study, ejaculates by masturbation from 746 subfertile men or healthy men who underwent semen analysis were examined. The median (interquartile range) semen collection time for all participants was 7.0 (5.0-11.0) min, and the median time taken for semen collection was lower in healthy men than that in subfertile men (6.0 min vs 7.0 min). An increase in the time required to produce semen samples was associated with poorer semen quality. Among those undergoing assisted reproductive technology (ART), the miscarriage rate was positively correlated with the semen collection time. After adjusting for confounders, the highest quartile (Q4) of collection time was negatively associated with semen volume and sperm concentration. A longer time to produce semen samples (Q3 and Q4) was negatively correlated with progressive and total sperm motility. In addition, there was a significant negative linear association between the semen collection time and the sperm morphology. Higher risks of asthenozoospermia (adjusted odds ratio [OR] = 2.06, 95% confidence interval [CI]: 1.31-3.25, P = 0.002) and teratozoospermia (adjusted OR = 1.98, 95% CI: 1.10-3.55, P = 0.02) were observed in Q3 than those in Q1. Our results indicate that a higher risk of abnormal semen parameter values was associated with an increase in time for semen collection, which may be related to male fertility through its association with semen quality.
Male
;
Humans
;
Semen Analysis
;
Semen
;
Sperm Motility
;
Sperm Count
;
Asthenozoospermia
;
Spermatozoa
9.Catheter ablation versus medical therapy for atrial fibrillation with prior stroke history: a prospective propensity score-matched cohort study.
Wen-Li DAI ; Zi-Xu ZHAO ; Chao JIANG ; Liu HE ; Ke-Xin YAO ; Yu-Feng WANG ; Ming-Yang GAO ; Yi-Wei LAI ; Jing-Rui ZHANG ; Ming-Xiao LI ; Song ZUO ; Xue-Yuan GUO ; Ri-Bo TANG ; Song-Nan LI ; Chen-Xi JIANG ; Nian LIU ; De-Yong LONG ; Xin DU ; Cai-Hua SANG ; Jian-Zeng DONG ; Chang-Sheng MA
Journal of Geriatric Cardiology 2023;20(10):707-715
BACKGROUND:
Patients with atrial fibrillation (AF) and prior stroke history have a high risk of cardiovascular events despite anticoagulation therapy. It is unclear whether catheter ablation (CA) has further benefits in these patients.
METHODS:
AF patients with a previous history of stroke or systemic embolism (SE) from the prospective Chinese Atrial Fibrillation Registry study between August 2011 and December 2020 were included in the analysis. Patients were matched in a 1:1 ratio to CA or medical treatment (MT) based on propensity score. The primary outcome was a composite of all-cause death or ischemic stroke (IS)/SE.
RESULTS:
During a total of 4.1 ± 2.3 years of follow-up, the primary outcome occurred in 111 patients in the CA group (3.3 per 100 person-years) and in 229 patients in the MT group (5.7 per 100 person-years). The CA group had a lower risk of the primary outcome compared to the MT group [hazard ratio (HR) = 0.59, 95% CI: 0.47-0.74, P < 0.001]. There was a significant decreasing risk of all-cause mortality (HR = 0.43, 95% CI: 0.31-0.61, P < 0.001), IS/SE (HR = 0.73, 95% CI: 0.54-0.97, P = 0.033), cardiovascular mortality (HR = 0.32, 95% CI: 0.19-0.54, P < 0.001) and AF recurrence (HR = 0.33, 95% CI: 0.30-0.37, P < 0.001) in the CA group compared to that in the MT group. Sensitivity analysis generated consistent results when adjusting for time-dependent usage of anticoagulants.
CONCLUSIONS
In AF patients with a prior stroke history, CA was associated with a lower combined risk of all-cause death or IS/SE. Further clinical trials are warranted to confirm the benefits of CA in these patients.
10.Design of intelligent positioning system for mobile medical equipment in operating room based on Bluetooth technology
Zhi-Meng LIU ; Ya-Dong LYU ; Long-Xue QIAO ; Lin-Huai TIAN ; Kun YANG ; Kai-Yuan LI ; Ning-Bo ZHAN ; Ying-Kang WEI ; Yong CHAO
Chinese Medical Equipment Journal 2023;44(9):29-32
Objective To develop an intelligent positioning system for mobile medical equipment in the operating room based on Bluetooth technology to enhance medical equipment management efficiency.Methods The intelligent positioning system for mobile medical equipment used received signal strength indication(RSSI)algorithm and multi-gateway trajectory filtering algorithm to realize Bluetooth positioning,which was composed of Bluetooth gateways,Bluetooth beacons,Bluetooth labels and a background data processing platform.The Bluetooth gateway consisted of an active power over ethernet(POE)module,a DC power module,a CPU,a Wi-Fi module and a Bluetooth module;the Bluetooth beacon included a beacon control unit,a Bluetooth transmitter module and a Bluetooth receiver module;the Bluetooth label was made up of a microcontroller unit(MCU),a Bluetooth module,an anti-temper switch and a accelerometer;the data processing platform had the front end developed with Vue architecture and the back end with Java language.Results The system developed could accurately locate the medical equipment in the operating room without electromagnetic interference to other medical devices.Conclusion The system developed gains advantages in high positioning accuracy,low electromagnetic interference,high stability and reliability and low cost,which improves the positioning and management efficiency of medical equipment under the premise of ensuring safety.[Chinese Medical Equipment Journal,2023,44(9):29-32]

Result Analysis
Print
Save
E-mail