1.Advances in polymorphisms of genes associated with oxaliplatin-induced peripheral neurotoxicity
China Pharmacy 2026;37(1):130-136
Peripheral neurotoxicity represents one of the most severe dose-limiting adverse reactions associated with oxaliplatin, with genetic polymorphisms playing a significant role in oxaliplatin-induced peripheral neuropathy (OIPN). OIPN can be categorized as acute or chronic based on onset timing. The former presents clinically as sensory abnormalities or even motor disorders, while the latter presents clinically as limb sensory disorders that persist, numbness or pain in the hands and feet. The transporter genes OCT2, OCTN2, and NHE1 may be implicated in OIPN; drug-metabolizing enzyme gene GSTP1 Ile105Val, DPYD rs1801265, voltage-gated sodium channel (NaV) gene SCN4A rs2302237, SCN9A rs6746030, SCN10A rs12632942, and other associated genes such as HLA-G rs1610696, rs371194629 and CCNH rs2230641, rs3093816 are associated with severe OIPN. Conversely, DNA repair-related gene XRCC1 rs23885, NaV gene SCN9A rs3750904, rs12478318 and rs6754031 are associated with reduced OIPN risk. In the future, the genetic research findings on OIPN can be translated into clinical applications, ultimately achieving individualized precision medicine for patients.
2.Clinical Efficacy and Radiographic Outcomes of Manipulative Reduction Combined with Small Splint Fixation for Distal Radius Fractures:A Retrospective Multicenter Study with Propensity Score Matching
Mao WU ; Guoda DAI ; Yang SHAO ; Shaoshuo LI ; Zhen HUA ; Hengyan CUI ; Tingchen ZHU ; Dipeng LI ; Jintao LIU ; Ming ZHOU ; Peimin WANG ; Liyong ZHANG ; Jianwei WANG
Journal of Traditional Chinese Medicine 2026;67(10):1086-1092
ObjectiveTo observe the clinical efficacy and radiographic outcomes of manipulative reduction combined with small splint fixation in the treatment of distal radius fractures. MethodsThe clinical data of 1051 patients with distal radius fractures were retrospectively collected from five hospitals included in the Jiangsu Diagnosis and Treatment Data Platform for Traditional Chinese Medicine(TCM) Dominant Diseases. Propensity score matching at a 1∶4 ratio was applied, resulting in 580 cases selected for final analysis, which comprised 448 patients in the TCM group(manipulative reduction plus small splint fixation) and 132 in the surgical treatment group(open reduction and internal fixation). Each group was further stratified into type A, B, and C subgroups based on AO fracture classification. Radiographic indicators including palmar tilt, radial inclination, and radial height were compared between groups before treatment and 1 day, 1 week, and 4-6 weeks after treatment, and pain visual analog scale(VAS) scores before treatment and 1 week and 4-6 weeks after treatment were also compared. Wrist joint function was assessed 12 weeks after treatment, using the Dienst wrist function score and the Gartland and Werley(G-W) wrist function score. Additionally, the radiographic indicators at different timepoints and the 12-week wrist function levels were compared between groups across different fracture types. ResultsNo statistically significant difference was observed in radiographic indicators and VAS scores at all timepoints before and after treatment, as well as wrist joint function grades assessed by the Dienst score and the G-W score at 12 weeks after treatment (P>0.05). Compared to those before treatment, both groups showed increased palmar tilt, radial inclination, and radial height 1 week and 4-6 weeks after treatment, and decreased VAS scores (P<0.05). Compared to those 1 week after treatment, both groups showed a decrease in palmar tilt, an increase in radial inclination and radial height, and a reduction in VAS score 4-6 weeks after treatment(P<0.05). In type A and B subgroups, the surgical treatment group had a higher radial inclination than the TCM group 4-6 weeks after treatment, while in the type C subgroup, a higher radial height was shown in the surgical treatment group than in the TCM group 4-6 weeks after treatment(P<0.05). In type C subgroup, there was significant difference between groups in the wrist joint function by G-W scores 12 weeks after treatment(P<0.05). ConclusionManipulative reduction combined with small splint fixation can maintain fracture alignment and alleviate pain in treating distal radius fractures, which achieves therapeutic outcomes comparable to surgical treatment. It is particularly suitable for type A and B fractures and can be considered an effective treatment option for distal radius fractures.
3.Construction and Clinical Validation of a Deep Learning-Based Automatic Measurement Model for Palmar Tilt and Radial Inclination in Distal Radius Fractures
Guoda DAI ; Jianwei WANG ; Mao WU ; Bin KANG ; Yang SHAO ; Hengyan CUI ; Shaoshuo LI ; Tingchen ZHU ; Zhen HUA ; Zhongming SHEN ; Jintao LIU ; Ming ZHOU
Journal of Traditional Chinese Medicine 2026;67(10):1093-1100
ObjectiveTo construct an automatic measurement model for palmar tilt and radial inclination suitable for traditional Chinese medicine (TCM) clinical scenarios, and to validate its accuracy and efficiency in TCM manipulative reduction settings. MethodsData on anteroposterior (AP) and lateral X-rays of distal radius fractures were collected from patients admitted to 18 TCM/ integrated TCM and western medicine hospitals in Jiangsu province between September 1st, 2023, and September 1st, 2024, via the Jiangsu Diagnosis and Treatment Big Data Platform for TCM Dominant Diseases. A medical image segmentation framework based on multi-scale feature fusion and edge-awareness was employed, combined with anatomical knowledge specific to TCM orthopedics, to optimize the feature extraction strategy of an artificial intelligence (AI) model. This framework enabled automatic segmentation of fracture regions and measurement of distal radius palmar tilt and radial inclination. The accuracy of the AI model in measuring radial inclination and volar tilt was validated, and the measurement time and average time gain rate of the AI model were compared to those of manual measurement. ResultsA total of 15,444 AP and lateral X-ray images of distal radius fractures were collected, and were divided into a training set (11,144 images, 5066 AP and 6078 lateral), a validation set (3700 images, 1840 AP and 1860 lateral), and an independent test set (600 images, 300 AP and 300 lateral) after preprocessing. In the measurement of 300 AP X-rays in the independent test set for radial inclination, when the degree error between AI measurement and manual measurement was <3° and <5°, AI measurement accuracy was 83% and 93%, respectively. In 300 lateral X-rays in the test set for palmar tilt, when AI measurements had an error of <3° and <5° compared to manual measurements, corresponding accuracy rate was 78% and 90%, respectively. For 50 X-ray images, AI measurement time was (1.37±0.05) min for radial inclination while manual measurement time was (22.57±2.52) min (P<0.001); in terms of palmar tilt, the AI measurement time was (1.33±0.14) min, shorter than (23.70±2.80) min for manual measurement time (P<0.001). Average time gain rates for manual and AI measurements were 93.93% and 94.39% respectively. ConclusionAn automatic measurement model for palmar tilt and radial inclination in distal radius fractures has been established, enabling more accurate and efficient assessment as well as providing a tool to support the quantitative evaluation of the efficacy of TCM manipulative reduction and large-sample clinical research.
4.Comprehensive analysis of the antibacterial activity of 5,8-dihydroxy-1,4-naphthoquinone derivatives against methicillin-resistant Staphylococcus aureus.
Qingqing CHEN ; Yuhang DING ; Zhongyi LI ; Xingyu CHEN ; Aliya FAZAL ; Yahan ZHANG ; Yudi MA ; Changyi WANG ; Liu YANG ; Tongming YIN ; Guihua LU ; Hongyan LIN ; Zhongling WEN ; Jinliang QI ; Hongwei HAN ; Yonghua YANG
Chinese Journal of Natural Medicines (English Ed.) 2025;23(5):604-613
Given the increasing concern regarding antibacterial resistance, the antimicrobial properties of naphthoquinones have recently attracted significant attention. While 1,4-naphthoquinone and its derivatives have been extensively studied, the antibacterial properties of 5,8-dihydroxy-1,4-naphthoquinone derivatives remain relatively unexplored. This study presents a comprehensive in vitro and in vivo analysis of the antibacterial activity of 35 naturally sourced and chemically synthesized derivatives of 5,8-dihydroxy-1,4-naphthoquinone. Kirby-Bauer antibiotic testing identified three compounds with activity against methicillin-resistant Staphylococcus aureus (MRSA), with one compound (PNP-02) demonstrating activity comparable to vancomycin in minimum inhibitory concentration, minimum bactericidal concentration (MBC), and time-kill assays. Microscopic and biochemical analyses revealed that PNP-02 adversely affects the cell wall and cell membrane of MRSA. Mechanistic investigations, including proteomic sequencing analyses, Western blotting, and RT-qPCR assays, indicated that PNP-02 compromises cell membrane integrity by inhibiting arginine biosynthesis and pyrimidine metabolism pathways, thereby increasing membrane permeability and inducing bacterial death. In an in vivo mouse model of skin wound healing, PNP-02 exhibited antibacterial efficacy similar to vancomycin. The compound demonstrated low toxicity to cultured human cells and in hemolysis assays and remained stable during serum incubation. These findings suggest that PNP-02 possesses promising bioactivity against MRSA and represents a potential novel antibacterial agent.
Methicillin-Resistant Staphylococcus aureus/genetics*
;
Anti-Bacterial Agents/chemistry*
;
Naphthoquinones/administration & dosage*
;
Animals
;
Microbial Sensitivity Tests
;
Mice
;
Humans
;
Staphylococcal Infections/microbiology*
;
Molecular Structure
5.Nano drug delivery system based on natural cells and derivatives for ischemic stroke treatment.
Wei LV ; Yijiao LIU ; Shengnan LI ; Kewei REN ; Hufeng FANG ; Hua CHEN ; Hongliang XIN
Chinese Medical Journal 2025;138(16):1945-1960
Ischemic stroke (IS) ranks as a leading cause of death and disability globally. The blood-brain barrier (BBB) poses significant challenges for effective drug delivery to brain tissues. Recent decades have seen the development of targeted nanomedicine and biomimetic technologies, sparking substantial interest in biomimetic drug delivery systems for treating IS. These systems are devised by utilizing or replicating natural cells and their derivatives, offering promising new pathways for detection and transport across the BBB. Their multifunctionality and high biocompatibility make them effective treatment options for IS. In addition, the incorporation of engineering techniques has provided these biomimetic drug delivery systems with active targeting capabilities, enhancing the accumulation of therapeutic agents in ischemic tissues and specific cell types. This improvement boosts drug transport and therapeutic efficacy. However, it is crucial to thoroughly understand the advantages and limitations of various engineering strategies employed in constructing biomimetic delivery systems. Selecting appropriate construction methods based on the characteristics of the disease is vital to achieving optimal treatment outcomes. This review summarizes recent advancements in three types of engineered biomimetic drug delivery systems, developed from natural cells and their derivatives, for treating IS. It also discusses their effectiveness in application and potential challenges in future clinical translation.
Humans
;
Drug Delivery Systems/methods*
;
Ischemic Stroke/drug therapy*
;
Animals
;
Blood-Brain Barrier/metabolism*
;
Stroke/drug therapy*
6.Lower vs. standard starting dose oral roxadustat for treating anemia in Chinese patients with chronic kidney disease on dialysis: A prospective, randomized clinical trial.
Yan TU ; Yan XU ; Li YAO ; Beiru ZHANG ; Tiekun YAN ; Aiping YIN ; Xinzhou ZHANG ; Min YANG ; Jun LIU ; Caili WANG ; Xiaomei PENG ; Jianqin WANG ; Wei NIU ; Wenqing JIANG ; Bi-Cheng LIU
Chinese Medical Journal 2025;138(19):2520-2522
7.Research on a portable electrical impedance tomography system for evaluating blood compatibility of biomaterials.
Piao PENG ; Huaihao CHEN ; Bo CHE ; Xuan LI ; Chunjian FAN ; Lei LIU ; Teng LUO ; Linhong DENG
Journal of Biomedical Engineering 2025;42(2):219-227
The evaluation of blood compatibility of biomaterials is crucial for ensuring the clinical safety of implantable medical devices. To address the limitations of traditional testing methods in real-time monitoring and electrical property analysis, this study developed a portable electrical impedance tomography (EIT) system. The system uses a 16-electrode design, operates within a frequency range of 1 to 500 kHz, achieves a signal to noise ratio (SNR) of 69.54 dB at 50 kHz, and has a data collection speed of 20 frames per second. Experimental results show that the EIT system developed in this study is highly consistent with a microplate reader ( R 2=0.97) in detecting the hemolytic behavior of industrial-grade titanium (TA3) and titanium alloy-titanium 6 aluminum 4 vanadium (TC4) in anticoagulated bovine blood. Additionally, with the support of a multimodal image fusion Gauss-Newton one-step iterative algorithm, the system can accurately locate and monitor in real-time the dynamic changes in blood permeation and coagulation caused by TC4 in vivo. In conclusion, the EIT system developed in this study provides a new and effective method for evaluating the blood compatibility of biomaterials.
Electric Impedance
;
Animals
;
Tomography/instrumentation*
;
Biocompatible Materials
;
Materials Testing/instrumentation*
;
Cattle
;
Titanium
;
Alloys
;
Prostheses and Implants
8.Neuroprotective effects of idebenone combined with borneol via the dopamine signaling pathway in a transgenic zebrafish model of Parkinson's disease.
Qifei WANG ; Yayun ZHONG ; Yanan YANG ; Kechun LIU ; Li LIU ; Yun ZHANG
Journal of Biomedical Engineering 2025;42(5):1046-1053
The aim of this study is to investigate the protective effect of idebenone (IDE) combined with borneol (BO) against Parkinson's disease (PD). In this study, wild-type AB zebrafish and transgenic Tg ( vmat2: GFP) zebrafish with green fluorescence labeled dopamine neurons were used to establish the PD model with 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine hydrochloride (MPTP). Following drug treatment, the behavioral performance and dopamine neuron morphology of zebrafish were evaluated, and regulation of dopamine signaling pathway-related genes was determined using RT-qPCR. The results showed that IDE combined with BO improved the behavioral disorders of zebrafish such as bradykinesia and shortening movement distance, also effectively reversed the damage of MPTP-induced dopaminergic neurons. At the same time, the expression of dopamine synthesis and transportation-related genes was up-regulated, and the normal function of the signal transduction pathway was restored. The combination showed a better therapeutic effect compared to the IDE monotherapy group. This study reveals the protective mechanism of IDE combined with BO on the central nervous system for the first time, which provides an important experimental basis and theoretical reference for clinical combination strategy in PD treatment.
Animals
;
Zebrafish
;
Signal Transduction/drug effects*
;
Animals, Genetically Modified
;
Dopamine/metabolism*
;
Neuroprotective Agents/pharmacology*
;
Disease Models, Animal
;
Camphanes/pharmacology*
;
Ubiquinone/pharmacology*
;
Parkinson Disease/drug therapy*
;
Dopaminergic Neurons/metabolism*
9.Comparative study of posterior axillary edge approach and arthroscopic assisted reduction in treatment of Ideberg type Ⅰ and Ⅱglenoid fracture of the scapula.
Bing LI ; Yanhong YUAN ; Peng XU ; Yabing YUAN ; Yuchen WANG ; Xingzhou ZHANG ; Zhangning HE
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):556-562
OBJECTIVE:
To compare the effectiveness of posterior axillary edge approach and arthroscopic assisted reduction in the treatment of Ideberg type Ⅰ and Ⅱ glenoid fracture of the scapula.
METHODS:
The clinical data of 26 patients with fresh Ideberg type Ⅰ and Ⅱ scapular fractures admitted between June 2021 and September 2024 who met the selection criteria were analyzed retrospectively. The patients were divided into two groups according to different treatment methods. Ten cases in the posterior axillary edge group were fixed by open reduction plate through the posterior axillary edge approach, and 16 cases in the arthroscopy group were treated with suture anchor fixation under arthroscopy. There was no significant difference in baseline data between the two groups ( P>0.05), such as gender, age, surgical side, Ideberg type, cause of injury, time from injury to operation, rotator cuff injury, and superior labrum anterior posterior (SLAP) injury, etc. The operation time and fracture healing time were recorded and compared between the two groups, and the shoulder pain was evaluated by visual analogue scale (VAS) score at 1 week, 1 month, and 3 months after operation. At 3 and 6 months after operation, the range of motion of shoulder joint in anteflexion, abduction, external rotation, internal rotation, and backward extension was evaluated, the upper limb dysfunction was evaluated by the Disability Assessment Scale of Arm, Shoulder, and Hand (DASH), and the shoulder joint function was evaluated by the Constant-Murley score. The differences between 6 months and 3 months after operation (changes) were statistically analyzed.
RESULTS:
Patients in both groups were followed up 11-13 months, with an average of 12.5 months. The operation time and fracture healing time in the posterior axillary edge group were significantly shorter than those in the arthroscopy group ( P<0.05). There was no complication such as wound infection, vascular and nerve injury, loss of reduction, bone nonunion, or glenohumeral instability in both groups. At 1 week after operation, the VAS score in the posterior axillary edge group was significantly higher than that in the arthroscopy group ( P<0.05); there was no significant difference in the VAS score between the two groups at 1 and 3 months after operation ( P>0.05). At 6 months after operation, the changes of shoulder joint in anteflexion, internal rotation range of motion and DASH scores in the posterior axillary edge group were significantly lower than those in the arthroscopy group ( P<0.05), while the changes of abduction, external rotation, backward extension range of motion and Constant-Murley scores were not significantly different between the two groups ( P>0.05).
CONCLUSION
For Ideberg type Ⅰ and Ⅱ glenoid fracture of the scapula, the posterior axillary edge approach for internal fixation has a short operation time, fast fracture healing, and is beneficial for early functional recovery; arthroscopic assisted reduction has minimal trauma and can handle joint injuries simultaneously. Both surgical procedures are safe and effective, and individualized selection should be made based on soft tissue conditions and combined injuries.
Humans
;
Arthroscopy/methods*
;
Scapula/surgery*
;
Male
;
Female
;
Retrospective Studies
;
Adult
;
Fracture Fixation, Internal/instrumentation*
;
Fractures, Bone/surgery*
;
Middle Aged
;
Treatment Outcome
;
Bone Plates
;
Suture Anchors
;
Fracture Healing
;
Range of Motion, Articular
;
Young Adult
;
Shoulder Joint/surgery*
;
Operative Time
10.Comparative study on implantation safety and stability of S 1 and S 2 sacral alar-iliac screws for sacroiliac joint fixation.
Qun CHEN ; Feng JI ; Qudong YIN ; Dong LI ; Xiaofei HAN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):723-728
OBJECTIVE:
To explore the differences in the implantation safety and stability of a S 1 alar-iliac screw (S1AIS) or S2AIS for sacroiliac joint fixation, providing reference for selecting appropriate internal fixation in clinical practice.
METHODS:
Patients who underwent pelvic CT examination between January 2024 and December 2024 were selected. CT data from 80 patients with normal pelvic structure who met the selection criteria were included in a 1∶1 male to female ratio. CT digital reconstruction technology was used to measure the transverse and longitudinal diameters of the S1AIS and S2AIS insertable ranges, as well as the length, width, and sacral side length of the screw trajectory. The pelvic CT data from 30 patients were randomly selected based on a 1∶1 male to female ratio for three-dimensional (3D) printing of pelvic samples. The S1AIS/S2AIS with a diameter of 6.5 mm and 8.0 mm were implanted at the optimal entry/exit points on the left and right sides, respectively, to observe the perforation of the screw trajectory. The pelvic CT data from 1 patient was randomly selected for 3D printing of 10 pelvic samples to simulate Tile C2 fracture. They were divided into S1AIS group ( n=5) and S2AIS group ( n=5), with one S1AIS and one S2AIS fixation used for posterior sacroiliac joint separation, and the specimen stiffness and maximum load were measured by using an electric tension torsion dual axis universal mechanical tester.
RESULTS:
The anatomical parameter measurement showed that there was no significant difference in the length and width of the screw trajectory between S1AIS and S2AIS ( P>0.05), but the transverse and longitudinal diameters of the insertable ranges, as well as the sacral side length of the screw trajectory, were all greater than those of S2AIS, with significant differences ( P<0.05). After simulating the implantation of S1AIS and S2AIS with a diameter of 6.5 mm in pelvic specimens, no screw penetration was observed. Both S1AIS and S2AIS with a diameter of 8.0 mm showed screw penetration, with S2AIS having a higher incidence of posterior lateral sacral cortical penetration (46.7%) than S1AIS (3.3%) ( P<0.05). The biomechanical test showed that the stiffness and maximum load of S2AIS were significantly lower than those of S1AIS ( P<0.05).
CONCLUSION
As a method to fix the sacroiliac joint, the S1AIS has a larger insertable range, a longer sacral side length of the screw trajectory, a lower incidence of posterior lateral cortical rupture of the sacrum, and a greater fixation strength than S2AIS. Therefore, the implantation safety and fixation stability of the S1AIS are superior to S2AIS, and a diameter less than 8.0 mm screws should be selected as S2AIS for Chinese people.
Humans
;
Bone Screws
;
Sacroiliac Joint/diagnostic imaging*
;
Male
;
Female
;
Sacrum/diagnostic imaging*
;
Fracture Fixation, Internal/instrumentation*
;
Ilium/diagnostic imaging*
;
Tomography, X-Ray Computed
;
Middle Aged
;
Adult
;
Printing, Three-Dimensional
;
Aged

Result Analysis
Print
Save
E-mail