1.Effect of different intensity neuromuscular training on muscle strength and knee joint function of patients after anterior cruciate ligament reconstruction
Juan WANG ; Qing ZHANG ; Changlin ZHOU ; Changyun CHEN ; Feng DAI ; Xianghong SUN ; Ting ZOU ; Jian WANG ; Junkai GAO ; Weidong XU
Chinese Journal of Rehabilitation Theory and Practice 2025;31(9):1083-1091
Objective To compare the effect of different intensity of neuromuscular training(NMT)on muscle strength and knee joint function of patients after anterior cruciate ligament reconstruction(ACLR).Methods From January,2023 to January,2024,60 ACLR patients in Changhai Hospital were selected,and they received the same intensity of NMT from one to eight weeks after surgery.Eight weeks after surgery,they were randomly divided into low intensity group(n=30)and high intensity group(n=30),and then they received different inten-sities of NMT from nine to 16 weeks after surgery,each training session lasted one hour,with three sessions per week,totaly 48 sessions.The Lysholm score,knee flexor and extensor muscle strength and muscle endurance-were compared at eight weeks and 16 weeks after surgery.Results After group training,the Lysholm score significantly increased in both groups(|t|>13.739,P<0.001),and was higher in the high intensity group than in the low intensity group(t=-2.574,P<0.05);in the high intensity group,the relative peak torque and endurance of the extensor and flexor muscles improved at angular velocities of 60°/s,120°/s and 180 °/s(|t|>2.320,P<0.05);in the low intensity group,the flexor peak torque improved at all the three angular velocities(t>2.177,P<0.05),the extensor peak torque improved at angular velocities of 60°/s and 180°/s(|t|>1.715,P<0.05),and the extensor endurance improved at angular velocity of 60°/s(t=-2.293,P<0.05).However,there was no significant difference in the relative peak torque and endurance of the extensor and flexor muscles at all the three angular velocities(P>0.05).Conclusion Both high and low intensity NMT could improve the muscle strength,muscle endurance and knee joint func-tion.Maybe,high intensity is superior to low intensity.Further verification is still needed.
2.Forensic performance and genetic background analyses of Guizhou Chuanqing population using a self-constructed microhaplotype panel.
Hongling ZHANG ; Changyun GU ; Qiyan WANG ; Xiaolan HUANG ; Qianchong RAN ; Zheng REN ; Yubo LIU ; Yansha LUO ; Shuaiji PAN ; Meiqing YANG ; Jingyan JI ; Xiaoye JIN
Journal of Southern Medical University 2025;45(7):1442-1450
OBJECTIVES:
To investigate the ethnic origin of Chuanqing people, one of the largest unidentified ethnic groups in Guizhou, China, and analyze its genetic relationships with surrounding populations.
METHODS:
Based on a self-developed microhaplotype system, we conducted genotyping and analyzed the genetic distribution of microhaplotype loci and their forensic applicability in Chuanqing population in Guizhou Province. Using the microhaplotype data from different intercontinental populations and previously reported data from Han population living in Guizhou Province, we systematically investigated the genetic background of Chuanqing people through population genetic approaches, including genetic distance estimation, principal component analysis, and phylogenetic tree construction.
RESULTS:
Among the studied population, the number of haplotype per microhaplotype ranged from 6 to 25. The average expected heterozygosity (He), observed heterozygosity (Ho), power of discrimination (PD), and probability of exclusion (PE) were 0.8291, 0.8301, 0.9387, and 0.6593, respectively. The cumulative power of discrimination (CPD) and cumulative probability of exclusion (CPE) for these 33 loci were 1-2.62×10-41 and 1-7.64×10-17, respectively. Population genetic analyses revealed that the Chuanqing population had close genetic relationships with the East Asian populations, especially the local Guizhou Han population, Beijing Han population and the Han populations living in southern China.
CONCLUSIONS
The 33 microhaplotypes exhibit high levels of genetic diversity in the Guizhou Chuanqing population, highlighting their potentials for both forensic identification and parentage testing. The Han populations might have contributed a significant amount of genetic material to the Chuanqing population during the formation and development of the latter.
Humans
;
China/ethnology*
;
Ethnicity/genetics*
;
Forensic Genetics/methods*
;
Genetics, Population
;
Genotype
;
Haplotypes
;
Phylogeny
;
East Asian People/genetics*
3.Effect of different intensity neuromuscular training on muscle strength and knee joint function of patients after anterior cruciate ligament reconstruction
Juan WANG ; Qing ZHANG ; Changlin ZHOU ; Changyun CHEN ; Feng DAI ; Xianghong SUN ; Ting ZOU ; Jian WANG ; Junkai GAO ; Weidong XU
Chinese Journal of Rehabilitation Theory and Practice 2025;31(9):1083-1091
Objective To compare the effect of different intensity of neuromuscular training(NMT)on muscle strength and knee joint function of patients after anterior cruciate ligament reconstruction(ACLR).Methods From January,2023 to January,2024,60 ACLR patients in Changhai Hospital were selected,and they received the same intensity of NMT from one to eight weeks after surgery.Eight weeks after surgery,they were randomly divided into low intensity group(n=30)and high intensity group(n=30),and then they received different inten-sities of NMT from nine to 16 weeks after surgery,each training session lasted one hour,with three sessions per week,totaly 48 sessions.The Lysholm score,knee flexor and extensor muscle strength and muscle endurance-were compared at eight weeks and 16 weeks after surgery.Results After group training,the Lysholm score significantly increased in both groups(|t|>13.739,P<0.001),and was higher in the high intensity group than in the low intensity group(t=-2.574,P<0.05);in the high intensity group,the relative peak torque and endurance of the extensor and flexor muscles improved at angular velocities of 60°/s,120°/s and 180 °/s(|t|>2.320,P<0.05);in the low intensity group,the flexor peak torque improved at all the three angular velocities(t>2.177,P<0.05),the extensor peak torque improved at angular velocities of 60°/s and 180°/s(|t|>1.715,P<0.05),and the extensor endurance improved at angular velocity of 60°/s(t=-2.293,P<0.05).However,there was no significant difference in the relative peak torque and endurance of the extensor and flexor muscles at all the three angular velocities(P>0.05).Conclusion Both high and low intensity NMT could improve the muscle strength,muscle endurance and knee joint func-tion.Maybe,high intensity is superior to low intensity.Further verification is still needed.
4.Positive effects of Xuebijing injection on intestinal microbiota and metabolite spectrum in septic rats.
Xianfei DING ; Yangyang YUAN ; Ran TONG ; Kun WANG ; Shaohua LIU ; Xueyan QI ; Xiaojuan ZHANG ; Jiebin CAO ; Tongwen SUN
Chinese Critical Care Medicine 2023;35(7):690-695
OBJECTIVE:
To explore the effect of Xuebijing injection on inflammation in sepsis by regulating intestinal microbiota and its metabolites.
METHODS:
A total of 45 male Sprague-Dawley (SD) rats were randomly divided into Sham operation group (Sham group), cecal ligation and perforation (CLP) induced sepsis group (CLP group), and Xuebijing intervention group (XBJ group, 4 mL/kg Xuebijing injection was injected intraperitoneally at 1 hour after CLP), with 15 rats in each group. The survival of rats was observed at 24 hours after operation and sacrificed. Feces were collected for 16S rRNA gene sequencing and liquid chromatography-mass spectrometry (LC-MS) analysis.
RESULTS:
At 24 hours after operation, all rats in the Sham group survived, the mortality of rats in the XBJ group was lower than that in the CLP group [47% (7/15) vs. 60% (9/15), P > 0.05]. Compared with the Sham group, the diversity of gut microbiota in the CLP group decreased, the dominant flora changed, and the abundance of inflammation-related flora increased. Xuebijing improved the changes in gut microbiota caused by sepsis, and α diversity showed an increasing trend (Ace index: 406.0±22.5 vs. 363.2±38.2, Chao1 index: 409.7±21.8 vs. 362.4±42.5, both P > 0.05). Restrictive constrained principal coordinate analysis (cPCoA) showed a high similarity in gut microbiota among the same group of rats. The CLP group was dominated by Bacteroidetes, while the Sham and XBJ groups were dominated by Firmicutes. In addition, compared with the CLP group, Xuebijing treatment increased the abundance of beneficial bacteria in septic rats, such as Verrucomicrobia, Akkermansia and Lactobacillus. LC-MS and orthogonal partial least squares discriminant analysis (OPLS-DA) showed that there were 12 main differential metabolites among the three groups, and there were certain correlations between these metabolites, which were related to amino acid and lipid metabolism. Correlation analysis showed a significant correlation between changes in metabolites and microbial communities.
CONCLUSIONS
Xuebijing can improve the survival rate of septic rats, regulate the composition of intestinal flora and related metabolites, which provides a new pathophysiological mechanism for Xuebijing in the treatment of sepsis.
Rats
;
Male
;
Animals
;
Rats, Sprague-Dawley
;
Gastrointestinal Microbiome
;
RNA, Ribosomal, 16S
;
Sepsis/metabolism*
;
Inflammation
5.Technical Difficulties in the Implementation of the Continuous Glucose Monitoring System.
Yacheng FU ; Changyun QUAN ; Lixia LIU ; Wei ZHANG
Chinese Journal of Medical Instrumentation 2022;46(4):422-427
The continuous glucose monitoring system (CGMS) has been clinically applied to monitor the dynamic change of the subcutaneous interstitial glucose concentration which is a function of the blood glucose level by glucose sensors. It can track blood glucose levels all day along, and thus provide comprehensive and reliable information about blood glucose dynamics. The clinical application of CGMS enables monitoring of blood glucose fluctuations and the discovery of hidden hyperglycemia and hypoglycemia that are difficult to be detected by traditional methods. As a CGMS needs to work subcutaneously for a long time, a series of factors such as biocompatibility, enzyme inactivation, oxygen deficiency, foreign body reaction, implant size, electrode flexibility, error correction, comfort, device toxicity, electrical safety, et al. should be considered beforehand. The study focused on the difficulties in the technology, and compared the products of Abbott, Medtronic and DexCom, then summarized their cutting-edge. Finally, this study expounded some key technologies in dynamic blood glucose monitoring and therefore can be utilized as a reference for the development of CGMS.
Blood Glucose
;
Blood Glucose Self-Monitoring/methods*
;
Humans
;
Hyperglycemia
;
Hypoglycemia
;
Monitoring, Ambulatory/methods*
;
Monitoring, Physiologic
6.Effects of different concentrations of sodium hypochlorite on dentine adhesion and the recovery application of sodium erythorbate.
Bihan ZHANG ; Donghui YANG ; Xilei ZHU ; Yaqin ZHOU ; Qinyi ZHU ; Changyun FANG
Journal of Central South University(Medical Sciences) 2022;47(2):226-237
OBJECTIVES:
Root canal therapy is the most effective and common method for pulpitis and periapical periodontitis. During the root canal preparation, chemical irrigation plays a key role. However, sodium hypochlorite (NaOCl), the widely used irrigation fluid, may impact the bonding strength between dentin and restorative material meanwhile sterilization and dissolving. Therefore, it's important to explore the influence of NaOCl on the adhesion between dentin and restoration materials to ensure clinical efficacy. This study aims to explore the effect of NaOCl on dentine adhesion and evaluate the effect of dentine adhesion induced by sodium erythorbate (ERY), and to provide clinical guidance on dentin bonding after root canal therapy.
METHODS:
Seventy freshly complete extracted human third molars aged 18-33 years old, without caries and restorations were selected. A diamond saw was used under running water to achieve dentine fragments which were divided into 10 groups with 14 fragments in each group: 2 control [deionized water (DW)±10% ERY] and 8 experimental groups (0.5%, 1%, 2.5%, and 5.25% NaOCl±10% ERY). The dentine specimens in the control group (treated with DW) and the experimental groups (treated with 0.5% NaOCl, 1% NaOCl, 2.5% NaOCl, and 5.25% NaOCl) were immersed for 20 min using corresponding solutions which were renewed every 5 min. The other 5 groups were immersed in 10% ERY for 5 min after an initial washing with DW for 1 min. Then, we selected 4 dentine fragments from all 14 fragments in each group and the numbers and diameters of opening dentinal tubules were observed under scanning electron microscope (SEM). The other 10 dentine fragments from each group were used to make adhesive samples by using self-etch adhesive wand composite resin. All the above adhesive samples were sectioned perpendicular to the bonded interface into 20 slabs with a cross-sectional area of 1 mm×1 mm using a diamond saw under the cooling water, and then the morphology of 10 slabs in each group's bonding interface was observed from aspects of formation of resin tags, depth of tags in dentin, and formation of hybrid layer under SEM. The other 10 slabs of each group's microtensile bond strength and failure modes were also analyzed.
RESULTS:
Among the 0.5% NaOCl, 1% NaOCl, 2.5% NaOCl, and 5.25% NaOCl groups, the number and diameter of patent dentinal tubules gradually increased with the rise of concentration of NaOCl solution (all P<0.05). Among the DW, 0.5% NaOCl, 1% NaOCl, 2.5% NaOCl, and 5.25% NaOCl groups, the number and diameter of patent dentinal tubules increased after using ERY, but without significant difference (all P>0.05). Among the DW, 0.5% NaOCl, 1% NaOCl, and 2.5% NaOCl groups, the scores of formation of resin tags under SEM gradually increased with the increase of concentration of NaOCl solution, while the score in the 5.25% NaOCl group decreased significantly compared with the score of the 2.5% NaOCl group (P<0.05). There was no significant difference between using 10% ERY groups and without using 10% ERY groups (all P>0.05). The scores of length of the tags under SEM in the 5.25% NaOCl group was significantly higher than the scores of DW, 0.5% NaOCl, and 1% NaOCl groups (all P<0.05), and it was also higher than the score of the 2.5% NaOCl group, but without significant difference (P>0.05). There was no significant difference between using 10% ERY groups and without using 10% ERY groups (P>0.05). The scores of formation of hybrid layer under SEM in the 2.5% NaOCl and 5.25% NaOCl groups significantly decreased compared with the score of the DW group (all P<0.05). There were significant differences between the 2.5% NaOCl±10% ERY groups and between the 5.25% NaOCl±10% ERY groups (all P<0.05). Microtensile bond strength was greater in the 0.5% NaOCl, 1% NaOCl, and 2.5% NaOCl groups, but lower in the 5.25% NaOCl group than that in the DW group (all P<0.05). There were significant differences between the 2.5% NaOCl±10% ERY groups and between the 5.25% NaOCl±10% ERY groups (all P<0.05). The incidence of type "Adhesive" of failure modes in the 5.25% NaOCl group was significantly higher than that in other groups (all P<0.05), while the incidence of type "Adhesive" in the 5.25% NaOCl+10% ERY group was lower than that in the 5.25% NaOCl group (P<0.05).
CONCLUSIONS
The bonding strength to dentine increases with the increase of NaOCl concentration when the concentration lower than 2.5%; whereas it is decreased at a higher concentration (such as 5.25%). 10% ERY has a definite recovery effect on attenuated bonding strength to 5.25% NaOCl-treated dentine.
Adolescent
;
Adult
;
Ascorbic Acid
;
Dental Bonding
;
Dentin
;
Dentin-Bonding Agents/pharmacology*
;
Diamond/pharmacology*
;
Humans
;
Materials Testing
;
Microscopy, Electron, Scanning
;
Resin Cements/pharmacology*
;
Sodium Hypochlorite/pharmacology*
;
Tensile Strength
;
Water/pharmacology*
;
Young Adult
7.2019-nCoV and herpes simplex virus type I were simultaneously isolated from a case of COVID-19
Wei ZHANG ; Xiaofang PENG ; Huan ZHANG ; Zhe LIU ; Baisheng LI ; Tianpeng HUANG ; Changyun SUN ; Lirong ZOU ; Lijun LIANG ; Qianfang GUO ; Jie WU ; Hui LI ; Huanying ZHENG
Chinese Journal of Experimental and Clinical Virology 2021;35(6):714-718
Objective:To understand the etiology of a confirmed case of Coronavirus Disease 2019 (COVID-19).Methods:The pharyngeal swabs, serum and nasal swabs of a case of COVID-19 were inoculated into Vero-E6 cell tubes for virus isolation. The cytopathic effect (CPE) were observed daily. Collecting cell’s isolation when CPE was over 75%, after repeated freezing and thawing for 3 times, the supernatant was centrifugally taken, and the images of the virus were obtained by transmission electron microscopic observation, and the nucleic acid of the virus was extracted, second generation sequencing and sequence evolution analysis were used to identify and type the virus strains.Results:One strain of 2019 novel coronavirus (2019-nCoV) was successfully isolated from the nasal swab of this case of COVID-19, and one strain of herpes simplex virus type 1 (HSV-1) was also successfully isolated from the throat swab of the same case.Conclusions:COVID-19 cases have the possibility of co-infection with 2019-nCoV and HSV-1.
8.Study on flow field characteristics of dust airflow in vibrating screen and optimization of dust removal system
Shanshan WU ; Jinning YU ; Jingyun LI ; Chunhong HE ; Changyun ZHANG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2021;39(9):696-699
In order to solve the problem of dust hazard of vibrating screen machine and difficult treatment in catalyst production process, computational fluid dynamics software Fluent was used to carry out numerical simulation calculation of the local exhaust dust removal system for the main dust dispersing points of the vibrating screen machine, including fine/coarse particles outlet and product outlet blowing and cleaning the dust points. The optimal design scheme and key technical parameters of local ventilation and dust removal system of vibrating screen machine were proposed. The results showed that the dust diffusion could be prevented by setting up an upper suction hood without air blowing, but the exhaust air volume needed to be calculated accurately. On the premise of purge, it is necessary to control the air volume to form a wind speed band of 8 m/s with a height of 15 cm at the feed port, so as to effectively remove the dust on the surface of solid particles of catalyst products and ensure that the catalyst products will not be blown away when falling into the feed barrel. The simulated design was applied to the vibrating sieve powder machine of a catalyst company, and the maximum dust concentration in the workplace was reduced from 45.80 mg/m 3 to 5.46mg/m 3, which effectively improved the working environment in the workplace.
9.Study on flow field characteristics of dust airflow in vibrating screen and optimization of dust removal system
Shanshan WU ; Jinning YU ; Jingyun LI ; Chunhong HE ; Changyun ZHANG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2021;39(9):696-699
In order to solve the problem of dust hazard of vibrating screen machine and difficult treatment in catalyst production process, computational fluid dynamics software Fluent was used to carry out numerical simulation calculation of the local exhaust dust removal system for the main dust dispersing points of the vibrating screen machine, including fine/coarse particles outlet and product outlet blowing and cleaning the dust points. The optimal design scheme and key technical parameters of local ventilation and dust removal system of vibrating screen machine were proposed. The results showed that the dust diffusion could be prevented by setting up an upper suction hood without air blowing, but the exhaust air volume needed to be calculated accurately. On the premise of purge, it is necessary to control the air volume to form a wind speed band of 8 m/s with a height of 15 cm at the feed port, so as to effectively remove the dust on the surface of solid particles of catalyst products and ensure that the catalyst products will not be blown away when falling into the feed barrel. The simulated design was applied to the vibrating sieve powder machine of a catalyst company, and the maximum dust concentration in the workplace was reduced from 45.80 mg/m 3 to 5.46mg/m 3, which effectively improved the working environment in the workplace.
10.Association between PON2 gene polymorphisms and susceptibility to noise-induced hearing loss
Shanshan WU ; Jinning YU ; Jie JIAO ; Guoshun CHEN ; Changyun ZHANG ; Shanfa YU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2020;38(2):128-132
Objective:To investigate the relationship between SNP and noise-induced hearing loss (NIHL) susceptibility in occupational noise exposure population in China.Methods:From 6297 for a certain steel works in contact with noise, contact length of 3 years or more and workplace noise exposure intensity of 80 dB (A) , ears or high frequency (3 000, 4 000, 6 000 Hz) average of hearing acuity 40 dB (HL) , or high frequency loss in both ears, on the basis of single whisper frequency (500, 1, 000, 2 000 Hz) average threshold of 26 dB (HL) or object as case group. A case-control study was designed with 1:1 matching. Subjects with the same gender, the same type of work, age ±5 years old, and working age ±2 years after noise exposure were selected as the control group. Subjects with any whisper frequency (500, 1, 000, 2, 000 Hz) whose hearing threshold in any frequency band was ≤25 dB (A) and whose average high-frequency hearing threshold in pure tone hearing test was <35 dB (A) were selected as the control group. Four sites of PON2 gene were genotyped by medium-and high-throughput SNP genotyping. Univariate logistic regression was used to analyze the relationship between single SNP polymorphism and NIHL.Results:A total of 286 case-control pairs were included. Smoking was statistically significant difference between cases and controls ( P<0.001) . Conclusion:No statistical difference has been found between single SNP polymorphism and NIHL. At the level of greater than 92 dB of high noise exposure, rs7785846 (CT+TT) genotype is a risk factor for occupational noise deafness, and its OR is 2.74 (95% CI: 1.09-6.89) compared with wild homozygous type (CC) . Conclusion. The rs7785846 (CT+TT) genotype carriers of PON2 gene are more susceptible to hearing impairment when exposed to high noise intensity.

Result Analysis
Print
Save
E-mail