1.Preliminary study on the implementation of HT for segmented TMLI in adults
Haiyang WANG ; Gaoxiang CHEN ; Xiang HUANG ; Ruigang GE ; Shilei ZHANG ; Changxin YAN ; Chuanbin XIE
China Medical Equipment 2025;22(9):21-26
Objective:To investigate the feasibility of segmented total marrow and lymphoid irradiation(TMLI)using Helical TomoTherapy(HT)in adults,and to analyze the impact of positional errors in the treatment on the actually received dose.Methods:Imaging data from four adult patients with acute myeloid leukemia were treated at the First Medical Center of the Chinese PLA General Hospital between November 2022 and December 2024 were retrospectively selected.The prescribed dose was 12 Gy in 3 fractions,and the heights range of patient was from 162 to 178 cm.The planning target volume(PTV)included the entire bone marrow and lymphatic drainage regions.The mid-femur was used as the dividing landmark,and the segmented location of head-in first(upper segmentation)and foot-in first(lower segmentation)were adopted to design plan for each segmentation.The upper segmentation used helical tomotherapy,and the lower segmentation used tomo direct therapy.The dosimetric parameters of planning target volume,and organ at risk(OAR)included eye lens,testicles and lungs were analyzed.The located computed tomography(CT)images of patients were used to simulate the changes of dosimetric parameters of each planning target region and OAR when the positions of patients moved 3,5,10 and 15 mm to outside of rack aperture.The changes of dose distribution of connection region of upper and lower segmentation were further analyzed.Results:The segmented irradiation technique can better achieve the cover(95%)of whole target region of TMLI under the condition of protecting normal organs.Under the condition with different position errors,the cover rate of the most of target region significant decreased.The largest dose of right lens increased 9.272%than primary under the 5 mm position error,and that of left and right lens increased respectively 40.199%and 67.898%under the 10 mm position error,and the max dose and mean dose of testicles increased respectively 5.847%and 5.240%under the 3mm position error.The mean dose of whole lung increased all under the error at different grades,which increased 3.021%under the 10mm position error.The non-uniformity of dose distribution of connection region increased after the position error was introduced,and the largest variation range reached to 4 Gy.Conclusion:The technique of segmented radiotherapy of Helical Tomotherapy has feasibility for TMLI of adult.But the error of the position of patients can reduce the cover of target region,and decrease the control rate for target region,and can lead to the occurrences of excessive doses on eye lens,testicles,lung and other OAR at the same time,which can increase the probability of occurring OAR injury.It should be high pay attention in treatment and implementation.
2.Segmented Time Study and Optimization Strategy for Clinical Application of Ethos Online Adaptive Radiotherapy.
Dandan ZHANG ; Yuhan KOU ; Shilong ZHU ; Xiaoyu LIU ; Meng NING ; Peichao BAN ; Jinyuan WANG ; Changxin YAN ; Zhongjian JU
Chinese Journal of Medical Instrumentation 2025;49(2):134-140
OBJECTIVE:
To analyze the time characteristics of the Ethos online adaptive radiotherapy (OART) process in clinical practice and provide guidance for the comprehensive optimization of each stage of adaptive radiotherapy.
METHODS:
The study involved 61 patients with cervical, rectal, gastric, lung, esophageal, and breast cancers who underwent Ethos OART. The mean ± standard deviation of segmental time, total time, and target volume for these patients were tracked. The time characteristics for different cancer types were evaluated, and the average time for target and organ at risk (OAR) modifications was compared with the average target volume for each cancer type.
RESULTS:
Cervical cancer born the longest total treatment time, while breast cancer had the shortest. For all cancer types except breast cancer, the modification time for target and OAR was the most time-consuming segment. The average time for target and OAR modifications aligned with the trend of the average target volume.
CONCLUSION
The total treatment time for various cancers ranges from 15 to 35 minutes, indicating room for improvement.
Humans
;
Radiotherapy Planning, Computer-Assisted/methods*
;
Neoplasms/radiotherapy*
;
Female
3.Preliminary study on the implementation of HT for segmented TMLI in adults
Haiyang WANG ; Gaoxiang CHEN ; Xiang HUANG ; Ruigang GE ; Shilei ZHANG ; Changxin YAN ; Chuanbin XIE
China Medical Equipment 2025;22(9):21-26
Objective:To investigate the feasibility of segmented total marrow and lymphoid irradiation(TMLI)using Helical TomoTherapy(HT)in adults,and to analyze the impact of positional errors in the treatment on the actually received dose.Methods:Imaging data from four adult patients with acute myeloid leukemia were treated at the First Medical Center of the Chinese PLA General Hospital between November 2022 and December 2024 were retrospectively selected.The prescribed dose was 12 Gy in 3 fractions,and the heights range of patient was from 162 to 178 cm.The planning target volume(PTV)included the entire bone marrow and lymphatic drainage regions.The mid-femur was used as the dividing landmark,and the segmented location of head-in first(upper segmentation)and foot-in first(lower segmentation)were adopted to design plan for each segmentation.The upper segmentation used helical tomotherapy,and the lower segmentation used tomo direct therapy.The dosimetric parameters of planning target volume,and organ at risk(OAR)included eye lens,testicles and lungs were analyzed.The located computed tomography(CT)images of patients were used to simulate the changes of dosimetric parameters of each planning target region and OAR when the positions of patients moved 3,5,10 and 15 mm to outside of rack aperture.The changes of dose distribution of connection region of upper and lower segmentation were further analyzed.Results:The segmented irradiation technique can better achieve the cover(95%)of whole target region of TMLI under the condition of protecting normal organs.Under the condition with different position errors,the cover rate of the most of target region significant decreased.The largest dose of right lens increased 9.272%than primary under the 5 mm position error,and that of left and right lens increased respectively 40.199%and 67.898%under the 10 mm position error,and the max dose and mean dose of testicles increased respectively 5.847%and 5.240%under the 3mm position error.The mean dose of whole lung increased all under the error at different grades,which increased 3.021%under the 10mm position error.The non-uniformity of dose distribution of connection region increased after the position error was introduced,and the largest variation range reached to 4 Gy.Conclusion:The technique of segmented radiotherapy of Helical Tomotherapy has feasibility for TMLI of adult.But the error of the position of patients can reduce the cover of target region,and decrease the control rate for target region,and can lead to the occurrences of excessive doses on eye lens,testicles,lung and other OAR at the same time,which can increase the probability of occurring OAR injury.It should be high pay attention in treatment and implementation.
4.Association between Metal(loid)Exposure and Risk of Polycystic Ovary Syndrome Mediated by Anti-Müllerian Hormone among Women Undergoing In Vitro Fertilization and Embryo Transfer
Su SHU ; Ren MENGYUAN ; Feng YANQIU ; Lan CHANGXIN ; Yan LAILAI ; Lu QUN ; Xu JIA ; Han BIN ; Zhuang LILI ; Fang MINGLIANG ; Wang BIN ; Bao HONGCHU ; Pan BO
Biomedical and Environmental Sciences 2024;37(10):1107-1116
Objective To investigate the relationship and potential pathways between metal(loid)exposure and the risk of polycystic ovary syndrome(PCOS)in women of childbearing age. Methods This case-control study included 200 patients with PCOS(cases)and 896 non-PCOS controls with the age of 25-37 years.The concentrations of 29 metal(loid)s in the follicular fluid(FF)and clinical indicators in the serum were measured in all participants.Logistic regression analysis and mediation analysis were conducted to evaluate the associations between metal(loid)exposure and PCOS risk and investigate the possible roles of clinical indicators,respectively. Results Logistic regression analysis revealed an association between high copper levels in FF and increased PCOS risk(highest vs.lowest quartile:adjusted odds ratio=2.94,95%confidence interval:1.83-4.72).A high luteinizing hormone/follicle-stimulating hormone ratio and elevated levels of testosterone and anti-Müllerian hormone(AMH)were strongly associated with increased PCOS risk induced by high copper exposure.The mediation analysis indicated a mediating effect of AMH in the association between copper exposure and PCOS risk. Conclusion Copper may affect PCOS risk through the hypothalamic-pituitary-ovarian axis,mediated by AMH.Copper exposure and internal AMH levels are important indicators for early warning of PCOS development.
5.Advance on research of Flash-RT technology
Xiangkun DAI ; Shaojuan WU ; Jinyuan WANG ; Wei YU ; Lehui DU ; Changxin YAN ; Shilei ZHANG ; Na MA ; Xiao LEI ; Baolin QU
China Medical Equipment 2024;21(1):2-8
At present,precise radiotherapy has been widely used through the development with many years,but the existing technique still is limited by the limitation of tolerance dose of normal tissues,which cannot achieve the optimal goal of treating tumor.Flash radiotherapy(Flash-RT)is one kind of radiotherapy technique that uses the beam with ultra-high dose rate(UHDR)to conduct irradiation,which can furthest treat tumors while significantly reduce radiation injury of normal tissues.But until now,the biological mechanism,key physical parameters and triggering mechanism of Flash-RT are still unclear,and its principle and clinical translational application are still in the stage of research.This review clarified the technological advance and clinical translational application of Flash-RT research through summarized the relevant research of Flash-RT.
6.Study on the influence of reconstruction algorithms of image on the image quality and precision of automatic registration of imaging system with megavolt grade
Xiaoyu LIU ; Gaoxiang CHEN ; Changxin YAN ; Peichao BAN ; Hongtao YU ; Shilong ZHU ; Kaiwen CHEN ; Chuanbin XIE
China Medical Equipment 2024;21(6):6-11
Objective:To compare and study the improvement of different iterative reconstruction(IR)algorithms of the tomotherapy(TOMO)Radixact system on the image quality of megavoltage computed tomography(MVCT)imaging system,and the influence of that on the precision of automatic registration,and to explore the reconstruction algorithm that is suitable for clinical application.Methods:Using the MVCT imaging system to respectively scan the Tomo-Phantom HE phantom and the Catphan 604 phantom,and to analyze three groups of images were generated by three kinds of reconstruction algorithms,which included the Standard(STD)algorithm,IR General(IR-G)algorithm and IR Soft Tissue(IR-ST)algorithm,in MVCT image.The noise index(NI),uniformity index(UI)of image,modulation transfer function(MTF),low contrast visibility(LCV)index and contrast-to-noise ratio(CNR)of three groups of images were calculated respectively.The Lucy phantom was used to test the accuracy of automatic registration algorithm.The registration data of four dimensions,included left-right(X-axis),head-foot(Y-axis),vertical(Z-axis)and free rotation(Roll)around the Y-axis,were used to conduct verification analysis for the influences of them on the precision of automatic registration.Results:The NI values of IR-G and IR-ST reconstruction algorithms were respectively 39.58±0.10 and 14.62±0.26,which were better than 39.58±0.10 of STD algorithm,and the UI values of them were respectively 19.87±0.83 and 15.84±2.51,which were better than 24.51±1.81 of STD algorithm,and LCV values of them were respectively 2.50±0.03 and 1.74±0.11,which were better than 3.67±0.04 of STD algorithm.All of them appeared significant increase,but the resolution with high contrast of MTF were respectively 0.23 and 0.21,which were lower than 0.32 of STD.The overall image quality of the IR algorithms was superior to that of the STD algorithm.In the accuracy test of the automatic registration algorithm,the registration precisions of IR-G and IR-ST algorithms on Y-axis were respectively(0.360±0.142)mm and(0.245±0.050)mm,which were significantly higher than 0.145±0.136 of STD algorithm,and the differences of them were significant(Z=6.0,15.0,P<0.05).The differences of registration precisions of other directions were not significant(P>0.05).Conclusion:The IR algorithm has advantages in terms of noise,uniformity and resolution with low-contrast,however,it shows reduction on resolution with high-contrast.This reduction of resolution with high-contrast do not lead to the decrease of the precision of automatic registration.
7.Analysis of image quality based on different imaging algorithms of the Ethos adaption radiotherapy system
Xiaoyu LIU ; Yuhan KOU ; Changxin YAN ; Jinyuan WANG ; Peichao BAN ; Dandan ZHANG ; Kaiwen CHEN ; Chuanbin XIE
China Medical Equipment 2024;21(11):1-6
Objective:To quantitatively analyze the differences in image quality and generated synthetic-computed tomography(sCT)between cone beam CT(CBCT)and iteration CBCT(iCBCT),which based on filtered back projection(FBP)and iterative reconstruction(IR)techniques of Varian Ethos adaption system.Methods:Using the special Catphan604 phantom of the test of CT image quality,five times of scanning series of CBCT and iCBCT were respectively performed based on thoracic and abdominal scanning protocols,so as to obtain four sets of images,and each set of image included the CBCT image,the composited sCT and iCBCT images based on CBCT,the composited sCT bases on iCBCT.The noise power spectrum(NPS),image uniformity(UI),modulation transfer function(MTF),low-contrast visibility(LCV)and contrast-to-noise ratio(CNR)of them were analyzed.Additionally,a retrospective analysis was conducted on images of six patients who underwent clinical radiotherapy,and the images of them were obtained by using thoracic and abdominal scanning protocols.The sCT images,which were generated by deformable registrations on the basis of CBCT and iCBCT,were analyzed,and they were compared with located CT images,and their mean absolute error(MAE)and root mean square error(RMSE)were further quantitatively analyzed.Results:Compared to CBCT,iCBCT significantly reduced NPS(thoracic images reduced by 0.08,abdominal images reduced by 0.06).The UI values of thoracic images and abdominal images of iCBCT were respectively 0.37 and 0.28,and those of CBCT were respectively 0.65 and 0.39.The LCV values of thoracic images and abdominal images of iCBCT were respectively 0.67 and 0.56,and those of CBCT were respectively 0.93 and 0.90.The MTF50%were 0.28 lp/mm except abdominal image of iCBCT was 0.29 lp/mm.The resolution rate of high contrast between iCBCT and CBCT was basic consistency.The differences of similarity analysis of the generated sCT and located CT bases on CBCT and iCBCT was no significant(P>0.05).Conclusion:The image quality of iCBCT is superior to conventional CBCT.The accuracy of CT value of generated sCT bases on CBCT and iCBCT can meet requirement,and both of them can be used in the dose calculation of adaptive radiotherapy.
8.Effect of high dose irradiation on thermoluminescence detector
Shuzhou RUAN ; Zhixin ZHAO ; Wenyi ZHANG ; Kaijun SU ; Xinxin PANG ; Fang WANG ; Yulian LIU ; Menghui HUO ; Changxin YAN ; Ling JIAO
International Journal of Biomedical Engineering 2019;42(4):342-345
Objective To investigate effect of high dose irradiation on the performances of thermolumines-cence detectors (LiF:Mg, Cu, P). Methods The high-dose irradiated thermoluminescence detector was annealed by a thermoluminescence annealing furnace until the annealing was completed, and then the annealed thermoluminescent detector was irradiated 0.5Gy by 137Cs irradiator to verify the accuracy of the thermoluminescentdetector. Results The thermoluminescence detector after high-dose irradiation could not be completely annealed under the temperature condition of 240 ℃, and it could be completely annealed at a high temperature as 400℃. After 0.5 Gy irradiation by 137Cs irradiator, the measurement results of the annealed thermoluminescence detector were significantly smaller, and the dose response and dispersion of the detector were also changed significantly. Conclusions After a more than 5 Gy irradiation, the crystal structure of the thermoluminescence detector has changed, and a high temperature peak above 240 ℃ has appeared, which leads to the failure to completely anneal at normal temperature. Therefore, the thermoluminescence detector can no longer be used for dosimetry after high-dose irradiation.
9.Cerebral autosomal recessive arteriopathy with subcortical infarcts and leukoencephalopathy
Yan LIU ; Changxin LI ; Xiaowei WU ; Zuopeng LI ; Ling LI ; Sha HONG
International Journal of Cerebrovascular Diseases 2017;25(9):834-838
Cerebral small vessel disease is a group of heterogeneous diseases with stroke and cognitive impairment as the main clinical features.It can be divided into sporadic type and hereditary type.Cerebral autosomal recessive arteriopathy with subcortical infarcts and leukoencephalopathy (CARASIL) belongs to hereditary cerebral small vessel disease.It has been reported in China,Japan,Spain,Greece,and other countries.The diagnosis mainly depends on characteristic clinical symptoms,imaging features,and genetic testing.CARASIL manifests as diffuse white matter abnormal signal and subcortical multiple infarcts on MRI,and it caused by HTRA1 gene mutation.
10.A Study on the Effective Measure Exploration for Higher Learning Institutes to Promote the International Communication of Traditional Chinese Medical Culture
Changxin YANG ; Kun QIAN ; Hua XU ; Yan TU ; Fei LE
World Science and Technology-Modernization of Traditional Chinese Medicine 2016;18(12):2194-2197
Traditional Chinese Medicine (TCM) is the gem of Chinese culture,while TCM culture the root and driving force for its development.Higher learning institutes,one of whose main missions is innovating and inheriting culture,are playing the unique roles in promoting world-wide recognition of TCM culture through international cooperation due to the abundant resources in TCM academy,talent,clinical study and international education.Taking Jiangxi University of Traditional Chinese Medicine as an example,this paper has made constructive exploration and study on how to promote the international communication of TCM culture to allow the international community for better understanding and the application of TCM based on the analysis of current situation and experience summarization with literature investigation and case study.Effective measures that have been put forward include establishing TCM experiencing center,promoting the construction of Confucius Institute,proactively building TCM library,improving the standardization of TCM translation,optimizing approaches of TCM international communication,and speeding up the cultivation of TCM international communication talents.