ObjectiveTo investigate the correlation between iron metabolism parameters and various syndrome types of unstable angina pectoris (UAP). MethodsA cross-sectional study was conducted from October 2021 to October 2023, encompassing 213 patients diagnosed with UAP at Xiyuan Hospital of Chinese Academy of Chinese Medical Sciences. Additionally, 30 healthy individuals were selected as control cases. Single-factor analysis was used to investigate the differences in clinical data among different Traditional Chinese Medicine (TCM) syndrome types of UAP and their correlation with iron metabolism indices. The study conducted a comparative analysis of the aforementioned clinical data among patients with and without heat-toxic and blood-stasis syndrome. Logistic regression was used to analyze the correlation between TCM syndrome types and related factors. The receiver operator characteristic (ROC) curve was employed to assess the predictive value of iron metabolism indices, along with their sensitivity and specificity. ResultsCompared to those in the control group, serum iron (SI) and serum ferritin (SF) levels were significantly increased in the UAP group (P<0.01), while transferrin (TRF) and total iron binding capacity (TIBC) levels were decreased (P<0.01). However, there was no significant difference in unsaturated iron binding capacity (UIBC). Multivariate binary Logistic regression analysis identified apolipoprotein A1 (ApoA1), homocysteine (HCY), high-sensitivity C-reactive protein (hs-CRP), and SF as independent influencing factors for the UAP patients (P<0.05, P<0.01). Additionally, statistically significant differences were observed in SI, SF, TRF, and TIBC among 213 patients with different TCM types (P<0.01). Patients with heat-toxic and blood-stasis syndrome had higher SI and SF values than those without the syndrome (P<0.01), while their TIBC and TRF values were lower (P<0.01). Multivariate binary logistic regression analysis showed that SI and LDL-C levels were closely associated with the differentiation of heat-toxic and blood-stasis syndrome. ConclusionUAP patients often experience iron metabolism disorders, and the heat-toxic and blood-stasis syndrome are significantly correlated with iron metabolism parameters. The SI and LDL-C levels have high specificity and sensitivity in diagnosing heat-toxic and blood-stasis syndrome.
2.Segmented Time Study and Optimization Strategy for Clinical Application of Ethos Online Adaptive Radiotherapy.
Dandan ZHANG ; Yuhan KOU ; Shilong ZHU ; Xiaoyu LIU ; Meng NING ; Peichao BAN ; Jinyuan WANG ; Changxin YAN ; Zhongjian JU
Chinese Journal of Medical Instrumentation 2025;49(2):134-140
OBJECTIVE:
To analyze the time characteristics of the Ethos online adaptive radiotherapy (OART) process in clinical practice and provide guidance for the comprehensive optimization of each stage of adaptive radiotherapy.
METHODS:
The study involved 61 patients with cervical, rectal, gastric, lung, esophageal, and breast cancers who underwent Ethos OART. The mean ± standard deviation of segmental time, total time, and target volume for these patients were tracked. The time characteristics for different cancer types were evaluated, and the average time for target and organ at risk (OAR) modifications was compared with the average target volume for each cancer type.
RESULTS:
Cervical cancer born the longest total treatment time, while breast cancer had the shortest. For all cancer types except breast cancer, the modification time for target and OAR was the most time-consuming segment. The average time for target and OAR modifications aligned with the trend of the average target volume.
CONCLUSION
The total treatment time for various cancers ranges from 15 to 35 minutes, indicating room for improvement.
Humans
;
Radiotherapy Planning, Computer-Assisted/methods*
;
Neoplasms/radiotherapy*
;
Female
3.Exploration on the influence of continuous infusion with long time on infusion precision of infusion pump
Changxin ZHANG ; Yu WANG ; Wenbo ZHOU ; Huiqing LIU ; Jing ZHAO
China Medical Equipment 2025;22(7):177-179,187
Objective:To investigate the influence of continuous infusion with long time on infusion precision of infusion pump,and establish a predictive model for flow velocity to predict the change of flow velocity of infusion pump after infusion with long time,so as to provide reference for the use of infusion pump in clinical treatment.Methods:Six infusion sets of different models,numbered A to F,were selected.A 24-hour continuous infusion experiment was conducted using an infusion pump with the above six infusion sets.The flow rate of the infusion pump was set to 100 mL/h,and real-time data of the infusion speed was recorded to evaluate the performance changes of the infusion pump under long-term continuous infusion.A flow rate prediction model for the infusion pump was established based on the research data,and the accuracy of the model was verified.Results:After 24 hours of continuous infusion,the infusion accuracy of infusion sets A to F showed varying degrees of decline over time.The final infusion accuracies were 96.47%,97.95%,92.56%,88.41%,89.26%,93.93%,respectively,with corresponding flow rate errors of 3.53%,2.05%,7.44%,11.59%,10.74%,6.07%.The prediction model established in this study was used to predict the flow rate of the infusion pump during 24-36 hours of continuous infusion.Compared with the actual flow rate under the same conditions,the difference was not statistically significant(P>0.05).Conclusion:Long-term continuous infusion affects the infusion accuracy of the infusion pump,resulting in a decrease in infusion speed.The established flow rate prediction model can accurately predict the flow rate of the infusion pump after long-term continuous infusion,providing a useful reference for the clinical application of infusion pumps.
4.Detection method for the performance of ultrasound probes based on pulse echo
Yu WANG ; Changxin ZHANG ; Jing ZHAO ; Guanghan LI ; Wenbo ZHOU ; Xinyuan DONG
China Medical Equipment 2025;22(3):157-159
The ultrasound probe is the most important accessory in ultrasound equipment,which adopted the piezoelectric vibrator as its core component,and it can complete ultrasonic emission and receiving echoes.A deep understanding for the operational characteristics of the probe's array elements is important premise that user can accurately judge the running situation of the probe.This study employed pulse-echo technique to detect sensitivity and capacitance of the array elements of ultrasonic probe.The detected data of 60 probes at China-Japan Friendship Hospital were collected,and 75%of the 60 probes existed residual couplant,and 80%of them existed indentation or damage to the outer skin.The tested results of leakage current indicated that 1 probe(1.7%)existed excessively high leakage current.In test for array elements,2 probes(3.4%)displayed partial damage at array elements,and 6 probes(10.2%)were irreparably damaged.The preventive test for the diagnostic equipment with ultrasound is helpful to establish a quality control system for ultrasound,and to provide analysis materials with reliability in using diagnostic equipment with ultrasound,and to also provide decision-making basis for equipment departments and clinical department of using equipment in hospital.
5.Preliminary study on the implementation of HT for segmented TMLI in adults
Haiyang WANG ; Gaoxiang CHEN ; Xiang HUANG ; Ruigang GE ; Shilei ZHANG ; Changxin YAN ; Chuanbin XIE
China Medical Equipment 2025;22(9):21-26
Objective:To investigate the feasibility of segmented total marrow and lymphoid irradiation(TMLI)using Helical TomoTherapy(HT)in adults,and to analyze the impact of positional errors in the treatment on the actually received dose.Methods:Imaging data from four adult patients with acute myeloid leukemia were treated at the First Medical Center of the Chinese PLA General Hospital between November 2022 and December 2024 were retrospectively selected.The prescribed dose was 12 Gy in 3 fractions,and the heights range of patient was from 162 to 178 cm.The planning target volume(PTV)included the entire bone marrow and lymphatic drainage regions.The mid-femur was used as the dividing landmark,and the segmented location of head-in first(upper segmentation)and foot-in first(lower segmentation)were adopted to design plan for each segmentation.The upper segmentation used helical tomotherapy,and the lower segmentation used tomo direct therapy.The dosimetric parameters of planning target volume,and organ at risk(OAR)included eye lens,testicles and lungs were analyzed.The located computed tomography(CT)images of patients were used to simulate the changes of dosimetric parameters of each planning target region and OAR when the positions of patients moved 3,5,10 and 15 mm to outside of rack aperture.The changes of dose distribution of connection region of upper and lower segmentation were further analyzed.Results:The segmented irradiation technique can better achieve the cover(95%)of whole target region of TMLI under the condition of protecting normal organs.Under the condition with different position errors,the cover rate of the most of target region significant decreased.The largest dose of right lens increased 9.272%than primary under the 5 mm position error,and that of left and right lens increased respectively 40.199%and 67.898%under the 10 mm position error,and the max dose and mean dose of testicles increased respectively 5.847%and 5.240%under the 3mm position error.The mean dose of whole lung increased all under the error at different grades,which increased 3.021%under the 10mm position error.The non-uniformity of dose distribution of connection region increased after the position error was introduced,and the largest variation range reached to 4 Gy.Conclusion:The technique of segmented radiotherapy of Helical Tomotherapy has feasibility for TMLI of adult.But the error of the position of patients can reduce the cover of target region,and decrease the control rate for target region,and can lead to the occurrences of excessive doses on eye lens,testicles,lung and other OAR at the same time,which can increase the probability of occurring OAR injury.It should be high pay attention in treatment and implementation.
6.Exploration on the influence of continuous infusion with long time on infusion precision of infusion pump
Changxin ZHANG ; Yu WANG ; Wenbo ZHOU ; Huiqing LIU ; Jing ZHAO
China Medical Equipment 2025;22(7):177-179,187
Objective:To investigate the influence of continuous infusion with long time on infusion precision of infusion pump,and establish a predictive model for flow velocity to predict the change of flow velocity of infusion pump after infusion with long time,so as to provide reference for the use of infusion pump in clinical treatment.Methods:Six infusion sets of different models,numbered A to F,were selected.A 24-hour continuous infusion experiment was conducted using an infusion pump with the above six infusion sets.The flow rate of the infusion pump was set to 100 mL/h,and real-time data of the infusion speed was recorded to evaluate the performance changes of the infusion pump under long-term continuous infusion.A flow rate prediction model for the infusion pump was established based on the research data,and the accuracy of the model was verified.Results:After 24 hours of continuous infusion,the infusion accuracy of infusion sets A to F showed varying degrees of decline over time.The final infusion accuracies were 96.47%,97.95%,92.56%,88.41%,89.26%,93.93%,respectively,with corresponding flow rate errors of 3.53%,2.05%,7.44%,11.59%,10.74%,6.07%.The prediction model established in this study was used to predict the flow rate of the infusion pump during 24-36 hours of continuous infusion.Compared with the actual flow rate under the same conditions,the difference was not statistically significant(P>0.05).Conclusion:Long-term continuous infusion affects the infusion accuracy of the infusion pump,resulting in a decrease in infusion speed.The established flow rate prediction model can accurately predict the flow rate of the infusion pump after long-term continuous infusion,providing a useful reference for the clinical application of infusion pumps.
7.Detection method for the performance of ultrasound probes based on pulse echo
Yu WANG ; Changxin ZHANG ; Jing ZHAO ; Guanghan LI ; Wenbo ZHOU ; Xinyuan DONG
China Medical Equipment 2025;22(3):157-159
The ultrasound probe is the most important accessory in ultrasound equipment,which adopted the piezoelectric vibrator as its core component,and it can complete ultrasonic emission and receiving echoes.A deep understanding for the operational characteristics of the probe's array elements is important premise that user can accurately judge the running situation of the probe.This study employed pulse-echo technique to detect sensitivity and capacitance of the array elements of ultrasonic probe.The detected data of 60 probes at China-Japan Friendship Hospital were collected,and 75%of the 60 probes existed residual couplant,and 80%of them existed indentation or damage to the outer skin.The tested results of leakage current indicated that 1 probe(1.7%)existed excessively high leakage current.In test for array elements,2 probes(3.4%)displayed partial damage at array elements,and 6 probes(10.2%)were irreparably damaged.The preventive test for the diagnostic equipment with ultrasound is helpful to establish a quality control system for ultrasound,and to provide analysis materials with reliability in using diagnostic equipment with ultrasound,and to also provide decision-making basis for equipment departments and clinical department of using equipment in hospital.
8.Preliminary study on the implementation of HT for segmented TMLI in adults
Haiyang WANG ; Gaoxiang CHEN ; Xiang HUANG ; Ruigang GE ; Shilei ZHANG ; Changxin YAN ; Chuanbin XIE
China Medical Equipment 2025;22(9):21-26
Objective:To investigate the feasibility of segmented total marrow and lymphoid irradiation(TMLI)using Helical TomoTherapy(HT)in adults,and to analyze the impact of positional errors in the treatment on the actually received dose.Methods:Imaging data from four adult patients with acute myeloid leukemia were treated at the First Medical Center of the Chinese PLA General Hospital between November 2022 and December 2024 were retrospectively selected.The prescribed dose was 12 Gy in 3 fractions,and the heights range of patient was from 162 to 178 cm.The planning target volume(PTV)included the entire bone marrow and lymphatic drainage regions.The mid-femur was used as the dividing landmark,and the segmented location of head-in first(upper segmentation)and foot-in first(lower segmentation)were adopted to design plan for each segmentation.The upper segmentation used helical tomotherapy,and the lower segmentation used tomo direct therapy.The dosimetric parameters of planning target volume,and organ at risk(OAR)included eye lens,testicles and lungs were analyzed.The located computed tomography(CT)images of patients were used to simulate the changes of dosimetric parameters of each planning target region and OAR when the positions of patients moved 3,5,10 and 15 mm to outside of rack aperture.The changes of dose distribution of connection region of upper and lower segmentation were further analyzed.Results:The segmented irradiation technique can better achieve the cover(95%)of whole target region of TMLI under the condition of protecting normal organs.Under the condition with different position errors,the cover rate of the most of target region significant decreased.The largest dose of right lens increased 9.272%than primary under the 5 mm position error,and that of left and right lens increased respectively 40.199%and 67.898%under the 10 mm position error,and the max dose and mean dose of testicles increased respectively 5.847%and 5.240%under the 3mm position error.The mean dose of whole lung increased all under the error at different grades,which increased 3.021%under the 10mm position error.The non-uniformity of dose distribution of connection region increased after the position error was introduced,and the largest variation range reached to 4 Gy.Conclusion:The technique of segmented radiotherapy of Helical Tomotherapy has feasibility for TMLI of adult.But the error of the position of patients can reduce the cover of target region,and decrease the control rate for target region,and can lead to the occurrences of excessive doses on eye lens,testicles,lung and other OAR at the same time,which can increase the probability of occurring OAR injury.It should be high pay attention in treatment and implementation.
9.Analysis of image quality based on different imaging algorithms of the Ethos adaption radiotherapy system
Xiaoyu LIU ; Yuhan KOU ; Changxin YAN ; Jinyuan WANG ; Peichao BAN ; Dandan ZHANG ; Kaiwen CHEN ; Chuanbin XIE
China Medical Equipment 2024;21(11):1-6
Objective:To quantitatively analyze the differences in image quality and generated synthetic-computed tomography(sCT)between cone beam CT(CBCT)and iteration CBCT(iCBCT),which based on filtered back projection(FBP)and iterative reconstruction(IR)techniques of Varian Ethos adaption system.Methods:Using the special Catphan604 phantom of the test of CT image quality,five times of scanning series of CBCT and iCBCT were respectively performed based on thoracic and abdominal scanning protocols,so as to obtain four sets of images,and each set of image included the CBCT image,the composited sCT and iCBCT images based on CBCT,the composited sCT bases on iCBCT.The noise power spectrum(NPS),image uniformity(UI),modulation transfer function(MTF),low-contrast visibility(LCV)and contrast-to-noise ratio(CNR)of them were analyzed.Additionally,a retrospective analysis was conducted on images of six patients who underwent clinical radiotherapy,and the images of them were obtained by using thoracic and abdominal scanning protocols.The sCT images,which were generated by deformable registrations on the basis of CBCT and iCBCT,were analyzed,and they were compared with located CT images,and their mean absolute error(MAE)and root mean square error(RMSE)were further quantitatively analyzed.Results:Compared to CBCT,iCBCT significantly reduced NPS(thoracic images reduced by 0.08,abdominal images reduced by 0.06).The UI values of thoracic images and abdominal images of iCBCT were respectively 0.37 and 0.28,and those of CBCT were respectively 0.65 and 0.39.The LCV values of thoracic images and abdominal images of iCBCT were respectively 0.67 and 0.56,and those of CBCT were respectively 0.93 and 0.90.The MTF50%were 0.28 lp/mm except abdominal image of iCBCT was 0.29 lp/mm.The resolution rate of high contrast between iCBCT and CBCT was basic consistency.The differences of similarity analysis of the generated sCT and located CT bases on CBCT and iCBCT was no significant(P>0.05).Conclusion:The image quality of iCBCT is superior to conventional CBCT.The accuracy of CT value of generated sCT bases on CBCT and iCBCT can meet requirement,and both of them can be used in the dose calculation of adaptive radiotherapy.
10.Impact of short-term exposure to atmospheric pollutants on the number of daily admissions for acute stroke: a time series study in Taiyuan, China
Xiaofeng LI ; Zexing LI ; Fangyi TIAN ; Shina SONG ; Shaoshuai WANG ; Changxin LI ; Jingxin LI
International Journal of Cerebrovascular Diseases 2024;32(3):180-185
Objective:To investigate the impact of short-term exposure to atmospheric pollutants on the number of acute stroke daily admissions in Taiyuan, China.Methods:The case data of patients with stroke from three large hospitals in different regions of Taiyuan, Shanxi Province from January 1, 2018 to December 31, 2019 were collected. The daily average concentrations of atmospheric pollutants and meteorological data in Taiyuan during the same period were collected. Spearman rank correlation was used to analyze the correlation between meteorological factors and atmospheric pollutants, and a generalized additive model (GAM) based on time series research and analysis was used to investigate the impact and lag effect of air pollutants on the number of stroke daily admissions. Stratified analysis was performed based on different genders and ages (≤64 years, 65-74 years, and ≥75 years).Results:Between 2018 and 2019, a total of 4 921 patients with acute stroke were collected from three large hospitals, with a daily average of 6.74 stroke admissions. Among them, 4 310 patients (87.6%) had ischemic stroke, 521 (10.6%) had cerebral hemorrhage, and 90 (1.8%) had subarachnoid hemorrhage. GAM analysis showed that there was a significant correlation between short-term exposure to PM 2.5, PM 10, and SO 2 and the number of stroke daily admissions. All three had a significant impact on the number of stroke daily admissions on the day of onset and 3 days later. The maximum effect value was reached on the day of onset, and when the average concentrations of PM 2.5, PM 10, and SO 2 increase by 10 μg/m 3, the number of stroke daily admissions increased by 1.48% (95% confidence interval [ CI] 0.46%-2.53%), 0.80% (95% CI 0.25%-1.36%), and 2.80% (95% CI 0.76%-4.88%), respectively. Stratified analysis showed that exposure to PM 2.5, PM 10, SO 2, and CO had a more significant impact on the number of stroke daily admissions in male patients, while only PM 10 showed positive results in females. Age stratified analysis showed that PM 2.5 significantly increased the number of stroke daily admissions in individuals aged ≥75 years. Conclusion:Short-term exposure to atmospheric pollutants (PM 2.5, PM 10, SO 2, and CO) will to some extent increase the number of stroke daily admissions among residents of Taiyuan, especially among males and those aged ≥75 years.