1.Quercetin Confers Protection against Sepsis-Related Acute Respiratory Distress Syndrome by Suppressing ROS/p38 MAPK Pathway.
Wei-Chao DING ; Juan CHEN ; Quan LI ; Yi REN ; Meng-Meng WANG ; Wei ZHANG ; Xiao-Hang JI ; Xin-Yao WU ; Shi-Nan NIE ; Chang-Bao HUANG ; Zhao-Rui SUN
Chinese journal of integrative medicine 2025;31(11):1011-1020
OBJECTIVE:
To identify the underlying mechanism by which quercetin (Que) alleviates sepsis-related acute respiratory distress syndrome (ARDS).
METHODS:
In vivo, C57BL/6 mice were assigned to sham, cecal ligation and puncture (CLP), and CLP+Que (50 mg/kg) groups (n=15 per group) by using a random number table. The sepsisrelated ARDS mouse model was established using the CLP method. In vitro, the murine alveolar macrophages (MH-S) cells were classified into control, lipopolysaccharide (LPS), LPS+Que (10 μmol/L), and LPS+Que+acetylcysteine (NAC, 5 mmol/L) groups. The effect of Que on oxidative stress, inflammation, and apoptosis in mice lungs and MH-S cells was determined, and the mechanism with reactive oxygen species (ROS)/p38 mitogen-activated protein kinase (MAPK) pathway was also explored both in vivo and in vitro.
RESULTS:
Que alleviated lung injury in mice, as reflected by a reversal of pulmonary histopathologic changes as well as a reduction in lung wet/dry weight ratio and neutrophil infiltration (P<0.05 or P<0.01). Additionally, Que improved the survival rate and relieved gas exchange impairment in mice (P<0.01). Que treatment also remarkedly reduced malondialdehyde formation, superoxide dismutase and catalase depletion, and cell apoptosis both in vivo and in vitro (P<0.05 or P<0.01). Moreover, Que treatment diminished the release of inflammatory factors interleukin (IL)-1β, tumor necrosis factor-α, and IL-6 both in vivo and in vitro (P<0.05 or P<0.01). Mechanistic investigation clarifified that Que administration led to a decline in the phosphorylation of p38 MAPK in addition to the suppression of ROS expression (P<0.01). Furthermore, in LPS-induced MH-S cells, ROS inhibitor NAC further inhibited ROS/p38 MAPK pathway, as well as oxidative stress, inflammation, and cell apoptosis on the basis of Que treatment (P<0.05 or P<0.01).
CONCLUSION
Que was found to exert anti-oxidative, anti-inflammatory, and anti-apoptotic effects by suppressing the ROS/p38 MAPK pathway, thereby conferring protection for mice against sepsis-related ARDS.
Animals
;
Sepsis/drug therapy*
;
Quercetin/therapeutic use*
;
Respiratory Distress Syndrome/enzymology*
;
p38 Mitogen-Activated Protein Kinases/metabolism*
;
Mice, Inbred C57BL
;
Reactive Oxygen Species/metabolism*
;
Apoptosis/drug effects*
;
Male
;
Oxidative Stress/drug effects*
;
MAP Kinase Signaling System/drug effects*
;
Lung/drug effects*
;
Mice
;
Lipopolysaccharides
;
Macrophages, Alveolar/pathology*
;
Inflammation/pathology*
;
Protective Agents/therapeutic use*
2.Glucocorticoid Discontinuation in Patients with Rheumatoid Arthritis under Background of Chinese Medicine: Challenges and Potentials Coexist.
Chuan-Hui YAO ; Chi ZHANG ; Meng-Ge SONG ; Cong-Min XIA ; Tian CHANG ; Xie-Li MA ; Wei-Xiang LIU ; Zi-Xia LIU ; Jia-Meng LIU ; Xiao-Po TANG ; Ying LIU ; Jian LIU ; Jiang-Yun PENG ; Dong-Yi HE ; Qing-Chun HUANG ; Ming-Li GAO ; Jian-Ping YU ; Wei LIU ; Jian-Yong ZHANG ; Yue-Lan ZHU ; Xiu-Juan HOU ; Hai-Dong WANG ; Yong-Fei FANG ; Yue WANG ; Yin SU ; Xin-Ping TIAN ; Ai-Ping LYU ; Xun GONG ; Quan JIANG
Chinese journal of integrative medicine 2025;31(7):581-589
OBJECTIVE:
To evaluate the dynamic changes of glucocorticoid (GC) dose and the feasibility of GC discontinuation in rheumatoid arthritis (RA) patients under the background of Chinese medicine (CM).
METHODS:
This multicenter retrospective cohort study included 1,196 RA patients enrolled in the China Rheumatoid Arthritis Registry of Patients with Chinese Medicine (CERTAIN) from September 1, 2019 to December 4, 2023, who initiated GC therapy. Participants were divided into the Western medicine (WM) and integrative medicine (IM, combination of CM and WM) groups based on medication regimen. Follow-up was performed at least every 3 months to assess dynamic changes in GC dose. Changes in GC dose were analyzed by generalized estimator equation, the probability of GC discontinuation was assessed using Kaplan-Meier curve, and predictors of GC discontinuation were analyzed by Cox regression. Patients with <12 months of follow-up were excluded for the sensitivity analysis.
RESULTS:
Among 1,196 patients (85.4% female; median age 56.4 years), 880 (73.6%) received IM. Over a median 12-month follow-up, 34.3% (410 cases) discontinued GC, with significantly higher rates in the IM group (40.8% vs. 16.1% in WM; P<0.05). GC dose declined progressively, with IM patients demonstrating faster reductions (median 3.75 mg vs. 5.00 mg in WM at 12 months; P<0.05). Multivariate Cox analysis identified age <60 years [P<0.001, hazard ratios (HR)=2.142, 95% confidence interval (CI): 1.523-3.012], IM therapy (P=0.001, HR=2.175, 95% CI: 1.369-3.456), baseline GC dose ⩽7.5 mg (P=0.003, HR=1.637, 95% CI: 1.177-2.275), and absence of non-steroidal anti-inflammatory drugs use (P=0.001, HR=2.546, 95% CI: 1.432-4.527) as significant predictors of GC discontinuation. Sensitivity analysis (545 cases) confirmed these findings.
CONCLUSIONS
RA patients receiving CM face difficulties in following guideline-recommended GC discontinuation protocols. IM can promote GC discontinuation and is a promising strategy to reduce GC dependency in RA management. (Trial registration: ClinicalTrials.gov, No. NCT05219214).
Adult
;
Aged
;
Female
;
Humans
;
Male
;
Middle Aged
;
Arthritis, Rheumatoid/drug therapy*
;
Glucocorticoids/therapeutic use*
;
Medicine, Chinese Traditional
;
Retrospective Studies
3.Autonomous drug delivery and scar microenvironment remodeling using micromotor-driven microneedles for hypertrophic scars therapy.
Ting WEN ; Yanping FU ; Xiangting YI ; Ying SUN ; Wanchen ZHAO ; Chaonan SHI ; Ziyao CHANG ; Beibei YANG ; Shuling LI ; Chao LU ; Tingting PENG ; Chuanbin WU ; Xin PAN ; Guilan QUAN
Acta Pharmaceutica Sinica B 2025;15(7):3738-3755
Hypertrophic scar is a fibrous hyperplastic disorder that arises from skin injuries. The current therapeutic modalities are constrained by the dense and rigid scar tissue which impedes effective drug delivery. Additionally, insufficient autophagic activity in fibroblasts hinders their apoptosis, leading to excessive matrix deposition. Here, we developed an active microneedle (MN) system to overcome these challenges by integrating micromotor-driven drug delivery with autophagy regulation to remodel the scar microenvironment. Specifically, sodium bicarbonate and citric acid were introduced into the MNs as a built-in engine to generate CO2 bubbles, thereby enabling enhanced lateral and vertical drug diffusion into dense scar tissue. The system concurrently encapsulated curcumin (Cur), an autophagy activator, and triamcinolone acetonide (TA), synergistically inducing fibroblast apoptosis by upregulating autophagic activity. In vitro studies demonstrated that active MNs achieved efficient drug penetration within isolated scar tissue. The rabbit hypertrophic scar model revealed that TA-Cur MNs significantly reduced the scar elevation index, suppressed collagen I and transforming growth factor-β1 (TGF-β1) expression, and elevated LC3 protein levels. These findings highlight the potential of the active MN system as an efficacious platform for autonomous augmented drug delivery and autophagy-targeted therapy in fibrotic disorder treatments.
4.An RNA-cleaving DNAzyme and G-Quadruplex DNAzyme-Cascade System for Sensing of Small Molecules in Organic Cosolvent
Su-Hui LI ; Shuai-Qi ZHANG ; Yi-Bo ZHANG ; Quan ZHENG ; Tian-Jun CHANG
Chinese Journal of Analytical Chemistry 2025;53(6):914-923
Detection of poor-water-soluble substances typically requires an organic solvent containing solution,and therefore,the biosensors that can operate in such conditions are highly promising for practical applications.However,most existing biosensors have been developed in aqueous solution and it is hard to work effectively in organic solvent systems.In this work,we uncovered that the G-quadruplex(G4)/hemin DNAzyme(G4HD)could be strongly reactivated by NH4 in organic solvents at concentration up to 30%,and the activity was significantly higher than that in aqueous solutions containing K+.Based on this discovery,a biosensing system was developed for small molecule in 40%methanol by coupling G4HD with our previously identified RNA-cleaving DNAzyme(E3).This system comprised an ATP-activated aptazyme that was made of E3 and a G4HD that was activated by the cleavage product of the aptazyme.By using a manmade pipette tip filter to separate the reaction products,the subsequent colorimetric reaction of the G4HD could be triggered.This biosensing system enabled the visualization of target molecules in organic cosolvents without any other instruments.The activable DNAzyme-cascade sensing system had potential in point-of-care detection of poor-water-soluble pollutants,thereby enhancing the practical values of functional nucleic acid-based biosensors in real-world detection conditions.
5.Extraction process optimization and content determination of eight nucleosides from Pheretima guillelmi
Quan-Lin YU ; Xue-Chun WU ; Yi QIU ; Jia-Jia SONG ; Qiao-Ping JIANG ; Chang-Sheng SUN ; Jing-Nan WU ; Cheng-Ke CAI ; Hong-Fei WANG
Chinese Traditional Patent Medicine 2024;46(8):2526-2530
AIM To optimize the extraction process for uracil,hypoxanthine,xanthine,uridine,thymine,inosine,guanosine and 2'-deoxyguanosine from Pheretima guillelmi(Michaelsen),and to determine their contents.METHODS With solid-liquid ratio,ultrasonic time and ultrasonic temperature as influencing factors,contents of hypoxanthine and total nucleosides as evaluation indices,the extraction process was optimized by orthogonal test.HPLC was adopted in the content determination of varioud nucleosides,the analysis was performed on a 30℃thermostatic Agilent C18 column(4.6 mm×250 mm,5 μm),with the mobile phase comprising of methanol-water flowing at 1 mL/min in a gradient elution manner,and the detection wavelength was set at 260 nm.RESULTS The optimal conditions were determined to be 1∶250 for solid-liquid ratio,60 min for ultrasonic time,and 60℃for ultrasonic temperature.Eight nucleosides showed good linear relationships within their own ranges(R2>0.999 0),whose average recoveries were 99.11%-103.27%with the RSDs of 0.85%-2.89%.CONCLUSION This stable and reliable method can be used for the extraction and content determination of nucleosides from P.guillelmi.
6.Discovery of highly potent phosphodiesterase-1 inhibitors by a combined-structure free energy perturbation approach.
Zhe LI ; Mei-Yan JIANG ; Runduo LIU ; Quan WANG ; Qian ZHOU ; Yi-You HUANG ; Yinuo WU ; Chang-Guo ZHAN ; Hai-Bin LUO
Acta Pharmaceutica Sinica B 2024;14(12):5357-5369
Accurate receptor/ligand binding free energy calculations can greatly accelerate drug discovery by identifying highly potent ligands. By simulating the change from one compound structure to another, the relative binding free energy (RBFE) change can be calculated based on the theoretically rigorous free energy perturbation (FEP) method. However, existing FEP-RBFE approaches may face convergence challenges due to difficulties in simulating non-physical intermediate states, which can lead to increased computational costs to obtain the converged results. To fundamentally overcome these issues and accelerate drug discovery, a new combined-structure RBFE (CS-FEP) calculation strategy was proposed, which solved the existing issues by constructing a new alchemical pathway, smoothed the alchemical transformation, increased the phase-space overlap between adjacent states, and thus significantly increased the convergence and accelerated the relative binding free energy calculations. This method was extensively tested in a practical drug discovery effort by targeting phosphodiesterase-1 (PDE1). Starting from a PDE1 inhibitor (compound 9, IC50 = 16.8 μmol/L), the CS-FEP guided hit-to-lead optimizations resulted in a promising lead (11b and its mesylate salt formulation 11b-Mesylate, IC50 = 7.0 nmol/L), with ∼2400-fold improved inhibitory activity. Further experimental studies revealed that the lead showed reasonable metabolic stability and significant anti-fibrotic effects in vivo.
7.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
8.Metabolomic Profiling of Mice Exposed to α-amanitin Using Ultra-performance Liquid Chromatography Quadrupole Time-of-flight Tandem Mass Spectrometry.
Lei LI ; Chong ZHENG ; Jian Fang YE ; Kai ZHU ; Yi Bing ZHOU ; Jia LIU ; Ming GAO ; Yu Tian WU ; Yong Ting LIU ; Li Ya LIU ; Ye LIN ; Hai Chang LI ; Quan ZHANG ; Hua GUO
Biomedical and Environmental Sciences 2023;36(3):289-294
9.Anythink for CT-based aorta root measurements before transcatheter aortic valve replacement: measurement consistency with 3mensio and impact on short-term prognosis.
Chang Fu LIU ; Ze Yu SUN ; Jing WANG ; Min Quan WANG ; Ran XIN ; Yi Pu DING ; Xi WANG ; Yang MU ; Tao CHEN ; Bo JIANG ; Lin WANG ; Ming ZHANG ; Dong Kai SHAN ; Yun Dai CHEN
Journal of Southern Medical University 2022;42(11):1646-1654
OBJECTIVE:
To evaluate the consistency and reproducibility of aortic root measurements by Anythink, a semi-automated preoperative CT analysis software, with those of 3mensio.
METHODS:
Sixty-seven patients undergoing transcatheter aortic valve replacement (TAVR) in the First Medical Center of Chinese PLA General Hospital from December, 2016 to February, 2022 were retrospectively enrolled in this study. A cardiology resident who completed his professional training used both the software Anythink and 3mensio (as the gold standard) to reconstruct the aortic root model and analyze the parameters of the aortic annulus and the surrounding structures. The correlation and consistency of the measurement results of two software were analyzed. Two independent residents also used Anythink software to repeat the measurements for the same patient for assessment of the reproducibility of Anythink measurements. The valve models were selected based on the measurements by Anythink and 3mensio, and similarities and differences of the two software in clinical valve selection were assessed.
RESULTS:
The measurements of the distances from the anulus plane to the left and right coronary ostium, average diameter of the anulus, anulus area, anulus perimeter, and the angle between the annulus and horizontal plane did not differ significantly between the two software (P > 0.05), and their measurements showed positive correlations (r= 0.884-0.981, P < 0.01). The intra-group and inter-group correlation coefficients of the anulus parameters measured by Anythink ranged from 0.894 to 0.992 and from 0.651 to 0.954, respectively. The Kappa-test values of valve models selected by Anythink and 3mensio based on the average diameter, area diameter and perimeter diameter were 0.886, 0.796 and 0.775, respectively. The intra-group Kappa values for the valve models selected based on Anythink measurements were 0.819, 0.841, and 0.795, and the inter-group Kappa values were 0.812, 0.812, and 0.768, respectively. Compared with the measurements by 3mensio, the recommended area diameter measured by Anythink was slightly greater in patients with postoperative paravalvular leakage, but slightly smaller in patients with postoperative new-onset conduction block.
CONCLUSION
Anythink has excellent measurement consistency and high reproducibility for aortic root measurements, and trained cardiologists can use Anythink to obtain accurate aortic root parameters before TAVR.
Humans
;
Transcatheter Aortic Valve Replacement
;
Reproducibility of Results
;
Retrospective Studies
;
Aorta
;
Tomography, X-Ray Computed
10.Knowledge about, attitude and acceptance towards, and predictors of intention to receive the COVID-19 vaccine among cancer patients in Eastern China: A cross-sectional survey.
Jing HONG ; Xiao-Wan XU ; Jing YANG ; Jing ZHENG ; Shu-Mei DAI ; Ju ZHOU ; Qing-Mei ZHANG ; Yi RUAN ; Chang-Quan LING
Journal of Integrative Medicine 2022;20(1):34-44
OBJECTIVE:
The coronavirus disease 2019 (COVID-19) pandemic has had a serious impact on health all over the world. Cancer patient, whose immunity is often compromised, faces a huge challenge. Currently, some COVID-19 vaccines are being developed and applied on general population; however, whether cancer patients should take COVID-19 vaccine remains unknown. Our study aimed to explore the knowledge, attitude, acceptance, and predictors of intention to receive the COVID-19 vaccine among cancer patients in Eastern China.
METHODS:
A cross-sectional study was conducted in Eastern China from June 17th to September 3rd, 2021. Patients were selected using a convenience sampling method. A self-report questionnaire was developed to assess knowledge about the COVID-19 vaccine, attitude towards the vaccine and acceptance of the vaccine; following a review of similar studies previously published in the scientific literature, multivariate logistic regression analysis was used to determine the predictors associated with COVID-19 vaccine acceptance.
RESULTS:
A total of 2158 cancer patients were enrolled in this study. The rate of vaccine hesitancy was 24.05% (519/2158); further, among the participants of vaccine acceptance, 767 had taken COVID-19 vaccine (35.54%), and 872 were willing to get vaccinated (40.01%). A total of 24 variables including demographic characteristics, clinical status of cancer, impact of COVID-19 pandemic on study participants, patients' knowledge about the COVID-19 vaccine, and attitude towards the vaccine, had significant differences between the "vaccine hesitancy" population and "vaccine acceptance" population. Multivariate logistic regression analysis indicated that parameters including alcohol consumption (odds ratio [OR] = 1.849; 95% confidence interval [CI]: 1.375-2.488; P-reference [P-Ref] < 0.001 vs non-drinkers), income impacted by COVID-19 pandemic (OR = 1.930, 2.037 and 2.688 for mild, moderate, and severe impact, respectively; all P-Ref < 0.01 vs no impact), knowledge of how the vaccine was developed (OR = 1.616; 95% CI: 1.126-2.318; P-Ref = 0.009 vs unknown), believing in the safety of the vaccine (OR = 1.502; 95% CI: 1.024-2.203; P-Ref = 0.038 vs denying the safety of vaccine), willingness to pay for the vaccine (OR = 3.042; 95% CI: 2.376-3.894; P-Ref < 0.001 vs unwilling), and willingness to recommend families and friends to get vaccinated (OR = 2.744; 95% CI: 1.759-4.280; P-Ref < 0.001 vs do not recommend) were contributors to vaccine acceptance. While such as being retired (OR = 0.586; 95% CI: 0.438-0.784; P-Ref < 0.001 vs unemployed), undergoing multiple therapies of cancer (OR = 0.408; 95% CI: 0.221-0.753; P-Ref = 0.004 vs no ongoing treatment), and worrying that the vaccine might deteriorate the prognosis of cancer (OR = 0.393; 95% CI: 0.307-0.504; P-Ref < 0.001 vs might not) were contributors to vaccine hesitancy.
CONCLUSION
This study provided preliminary estimates of the rates of vaccine acceptance and vaccine hesitancy among cancer patients in Eastern China. The intention to receive the COVID-19 vaccine was impacted by factors such as patient occupation, alcohol consumption, and some parts of knowledge about and attitude towards COVID-19 vaccine. It is recommended to develop individualized vaccination plans that meet the healthcare needs of cancer patients.
COVID-19
;
COVID-19 Vaccines
;
China
;
Cross-Sectional Studies
;
Humans
;
Intention
;
Neoplasms
;
Pandemics
;
SARS-CoV-2
;
Vaccination Hesitancy

Result Analysis
Print
Save
E-mail