1.Comparison of short-term clinical efficacy between CO external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures.
Min-Rui FU ; Chang-Long SHI ; Yong-Zhong CHENG ; Ming-Ming MA ; Zheng-Lin NIU ; Hai-Xiang SUN ; Jing-Hua GAO ; Zhong-Kai WU ; Yi-Ming XU
China Journal of Orthopaedics and Traumatology 2025;38(1):10-17
OBJECTIVE:
To evaluate the short-term clinical efficacy of external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures (AO-23C type), based on the principles of Chinese osteosynthesis (CO).
METHODS:
Forty-eight patients with unstable distal radius fractures between January 2022 and February 2023 were retrospectively analyzed and divided into the CO external fixation group and internal fixation group. CO external fixation group consisted of 25 patients, including 7 males and 18 females, aged from 37 to 56 years old with an average of ( 52.6±11.3) years old. Among them, there were 7 patients of traffic accidents and 18 patients of falls, resulting in a total of 25 patients of closed fractures and no open fractures, the treatment was conducted using closed reduction and CO external fixation. The internal fixation group consisted of 23 patients, comprising 8 males and 15 females, age ranged from 41 to 59 years old, with an average age of(53.3±13.7) years old. Among them, 8 patients resulted from car accidents while the remaining 15 patients were caused by falls. All 23 patients were closed fractures without any open fractures observed. The technique of open reduction and internal fixation with steel plate was employed. The perioperative data, including injury-operation time, operation duration, blood loss, and length of hospital stay, were assessed in both groups. Additionally, the QuickDASH score and visual analogue scale (VAS) were evaluated. Range of motion and grip strength assessment, imaging findings such as palmar inclination angle, ulnar declination angle, radius length, articular surface step, intra-articular space measurements were also examined along with any complications.
RESULTS:
The follow-up duration ranged from 0 to 24 months, with an average duration of (16.0±3.8) months. The CO external fixation exhibited significantly shorter time from injury to operation (2.4±3.3) d vs (7.4±3.7) d, shorter operation duration (56.27±15.23) min vs (74.10±5.26) min, lower blood loss (14.52±6.54) ml vs (32.32±10.03) ml, and reduced hospitalization days (14.04±3.24 )d vs (16.45±3.05) d compared to the internal fixation group (P<0.05). The QuickDASH score at 12 months post-operation was (8.21±1.64) in the CO external fixation group, while no significant difference was observed in the internal fixation group (7.04±3.64), P>0.05. There were no statistically significant differences in VAS between two groups at 6 weeks, as well as 1 and 3 months post-surgery (P>0.05). Additionally, there were no significant disparities observed in terms of range of motion and grip strength between two groups at the 2-year follow-up after the operation (P>0.05). After 12 months of surgery, the CO external fixation group exhibited a significantly smaller palmar inclination angle (17.90±2.18) ° vs (19.87±3.21) °, reduced articular surface step (0.11±0.03) mm vs (0.17±0.02) mm, and shorter radius length (8.16±1.11) mm compared to the internal fixation group (9.59±1.02) mm, P<0.05. The ulnar deviation angle and intra-articular space did not show any significant difference between two groups (P>0.05). The reduced fell within the allowable range between the CO external fixation group (23 out of 25 cases) and the internal fixation group (21 out of 23 cases) was not statistically significant (P=0.29). There was no significant difference in complications between the two groups(P>0.05).
CONCLUSION
Both the CO external fixation and open reduction with plate internal fixation demonstrate clinical efficacy in managing unstable distal radius fractures. The CO external fixation offers advantages in shorter injury-to-operation times, reduced intraoperative blood loss, and decreased surgical durations, while radial shortening is more effectively controlled by internal fixation.
Humans
;
Male
;
Female
;
Middle Aged
;
Radius Fractures/physiopathology*
;
Adult
;
Bone Plates
;
Fracture Fixation, Internal/methods*
;
External Fixators
;
Retrospective Studies
;
Fracture Fixation/methods*
;
Wrist Fractures
3.A quality improvement study on improving the follow-up rate of preterm infants after discharge.
He-Sheng CHANG ; Xue YANG ; Jun JU ; Wen-Ya XU ; Di WU ; Xiao-Man WAN ; Zheng-Hong LI
Chinese Journal of Contemporary Pediatrics 2025;27(2):148-154
OBJECTIVES:
To explore the measures to improve the follow-up rate of preterm infants after discharge, and to evaluate the effectiveness of these measures using quality improvement methodology.
METHODS:
The follow-up status of preterm infants discharged from March to May 2017 was used as the baseline before quality improvement, and a specific quality improvement goal for the follow-up rate was proposed. The Pareto chart was used to analyze the causes of follow-up failure, and a key driver diagram was constructed based on the links involved in improving follow-up rate. The causes of failure were analyzed to determine the key links and intervention measures for quality improvement, and the follow-up rate was monitored weekly using a control chart until the quality improvement goal was achieved.
RESULTS:
The follow-up rate of preterm infants after discharge was 57.92% (117/202) at baseline before quality improvement, and the quality improvement goal was set to increase the follow-up rate of preterm infants from baseline to more than 80% within 12 months. The Pareto chart analysis showed that the main causes of follow-up failure were deficiencies in follow-up file management and irregular follow-up times (33.70%, 31/92), insufficient follow-up education and poor communication (25.00%, 23/92), and the inability to meet the diverse needs of parents (18.48%, 17/92). Based on the key links for quality improvement and the main causes of follow-up failure, the following intervention measures were adopted: (1) strengthen follow-up publicity and education; (2) build a follow-up team; and (3) establish a follow-up platform and system. The control chart indicated that with the implementation of the above intervention measures, the weekly follow-up rate increased to 74.09% (306/413) in July 2017 and 83.09% (511/615) in December 2017, finally achieving the quality improvement goal. During the COVID-19 pandemic, the follow-up rate of preterm infants fluctuated between 23.54% (460/1 954) and 70.97% (1 931/2 721), and subsequently, it returned to pre-pandemic levels starting in February 2023.
CONCLUSIONS
The application of quality improvement methodology can help to formulate intervention measures based on the main causes of follow-up failure, thereby improving the follow-up rate of preterm infants after discharge. This quality improvement method is feasible and practical and thus holds promise for clinical application.
Humans
;
Quality Improvement
;
Infant, Premature
;
Infant, Newborn
;
Patient Discharge
;
Follow-Up Studies
;
Female
;
Male
4.A new phenolic acid isolated from Salvia miltiorrhiza ameliorates OVA-induced allergic asthma by regulation of Th17/Treg cells and inflammation through the TLR4 pathway.
Zeng MENGNAN ; Wu YUANYUAN ; Ren YINGJIE ; Jiao XIANMIAN ; Chang FANGZHUO ; Wang YUANYUAN ; Feng WEISHENG ; Zheng XIAOKE
Chinese Journal of Natural Medicines (English Ed.) 2025;23(12):100007-100007
Salvia miltiorrhiza (S. miltiorrhiza) represents a crucial component of traditional Chinese medicine, demonstrating effects on blood circulation activation and stasis removal, and has been widely utilized in asthma treatment. This study isolated a novel phenolic acid (S1) from S. miltiorrhiza and investigated its anti-asthmatic activity and underlying mechanisms for the first time. An allergic asthma (AA) model was established using ovalbumin (OVA). The mechanism of S1's effects on AA was investigated using multi-factor joint analysis, flow cytometry, and co-culture systems to facilitate clinical asthma treatment. S1 (10 or 20 mg·kg-1) was administered daily to mice with OVA-induced AA (OVA-AA) during days 21-25. The study examined airway responsiveness, lung damage, inflammation, and levels of immunoglobulin E (IgE), PGD2, interleukins (IL-4, 5, 10, 13, 17A), tumor necrosis factor α (TNF-α), GM-CSF, CXCL1, CCL11, and mMCP-1. Additionally, mast cell (MC) activation and degranulation were explored, along with T helper type 17 (Th17)/Treg immune cells and TLR4 pathway biomarkers. The antagonistic activity of that specific antagonist of TLR4 (TAK-242) (1 µmol·L-1), a specific TLR4 blocker, against S1 (10 µmol·L-1) was examined in co-cultured 16HBE cells and bone marrow-derived cells (BMDCs) or splenic lymphocytes (SLs) induced with LPS (1 µg·mL-1) to elucidate the TLR4 pathway's mediating role. S1 demonstrated reduced airway responsiveness, lung damage, and inflammation, with downregulation of IgE, PGD2, interleukins, TNF-α, GM-CSF, CXCL1, CCL11, and mMCP-1. It also impeded MC activation and degranulation, upregulated IL-10, and influenced Th17/Treg immune cell transformation following OVA challenge. Furthermore, S1 inhibited the TLR4 pathway in OVA-AA mice, and TLR4 antagonism enhanced S1's positive effects. Analysis using an OVA-AA mouse model demonstrated that S1 alleviates AA clinical symptoms, restores lung function, and inhibits airway response. S1's therapeutic effects occur through regulation of Th17/Treg immune cells and inflammation, attributable at least partially to the TLR4 pathway. This study provides molecular justification for S1 in AA treatment.
5.Water extract of Rehmannia glutinosa improves bleomycin-induced pulmonary fibrosis in mice and its metabolic mechanism
Zi-yu ZHANG ; Meng-nan ZENG ; Peng-li GUO ; Yu-han ZHANG ; Xiang-da LI ; Yan-xing WU ; Shuang-ying FU ; Zi-chang LIAN ; Wei-sheng FENG ; Xiao-ke ZHENG
Chinese Pharmacological Bulletin 2025;41(12):2315-2325
Aim To investigate the intervention effect of Rehmannia radix water extract on bleomycin(BLM)-induced pulmonary fibrosis in mice combined with metabolomics and to reveal the potential mechanism,in order to provide new ideas for clinical treatment of pul-monary fibrosis.Methods Male C57BL/6N mice were randomly divided into the control group,model group,pirfenidone group(positive control,PFD,270 mg·kg-1),and low dose(DH-L,4.55 g·kg-1)group,medium dose(DH-M,9.1 g·kg-1)group and high dose(DH-H,18.2 g·kg-1)group of Rehman-nia.Except for the control group,BLM(5 mg·kg-1)was instilled into the trachea to establish the model of pulmonary fibrosis in the other groups.The survival rate,lung index and blood oxygen saturation of mice in each group were evaluated.HE and Masson staining were used to observe the pathological changes of lung tissue.WBP was used to detect lung function.Flow cytometry was used to detect the apoptosis of primary lung cells,ROS and immune cells.ELISA was used to detect the levels of fibrosis markers and inflammatory factors(α-SMA,collagen Ⅰ,collagen Ⅲ,TGF-β1,TNF-α,IL-1 β,and IL-6).Biochemical method was employed to detect the contents of GSH-Px,T-SOD and MDA.Liquid chromatograph mass spectrometer(LC-MS)metabolomics was used to analyze the changes of serum metabolic profile.Results Water extract of Re-hmannia significantly increased the survival rate,oxy-gen saturation and lung function of mice with pulmona-ry fibrosis,reduced the lung coefficient,ameliorated pathological damage and collagen deposition in lung tissue,reduced the levels of apoptosis and oxidative stress,and down-regulated the levels of inflammatory factors in lung tissue.It regulated the levels of metabo-lites such as bile acid metabolism,sphingolipid metabo-lism,and unsaturated fatty acid metabolism.Conclu-sions Water extract of Rehmannia inhibits lung injury and collagen deposition in mice with pulmonary fibrosis by inhibiting inflammatory response,which may be a-chieved by regulating the levels of inflammatory factors through the metabolic pathways of bile acid and sphin-golipid.
6.Analysis of the current status of domestic medical drainage tube patents based on patent information mining
Feng MA ; Chuxin CHANG ; Yan LI ; Lengjianghai ZHENG ; Ruimin GONG ; Juntao DUAN ; Rongqian WU ; Yi LV ; Xiaoyun KANG
Journal of Xi'an Jiaotong University(Medical Sciences) 2025;46(6):1013-1019
Objective To analyze the current status and emerging technology trends in domestic medical drainage tube patents,so as to explore possible factors for low patent conversion rates.Methods Patents associated with"drainage tube","medical drainage tube","surgical drainage tube"and related terms were retrieved from the National Intellectual Property Administration Database and the Innojoy Patent Search Engine,covering the period from 2010 to 2020.Screening and visual analysis were conducted using Excel and SPSS 27.0.Results A total of 2 895 relevant patents were identified,comprising 2 489 utility model patents,367 invention patents and 39 design patents.The number of patent applications demonstrated a year-on-year growth trend,with a higher concentration in eastern coastal regions and provinces housing numerous top-tier hospitals and medical institutions.Approximately 49.26%of the patents filed by individuals were affiliated with hospitals,universities,or enterprises.Innovation hotspots included the design,functionality,performance,and safety aspects of drainage tubes and probes.Of the patents,72.61%were invalid,and 61.73%had a survival period of three years or less.Only 5.15%were commercially utilized through transfers,pledges,or licensing.Conclusion Domestic patent applications for medical drainage tubes have seen rapid growth,with a focus on enhancing tube structures such as sleeves,balloons,drainage holes,and threaded designs.However,the unsatisfactory situation of patent conversion and operation have been mainly limited by factors such as weak core technology of patents,insufficient awareness of achievements conversion,poor operation of patent conversion mechanism,insufficient market promotion,and insufficient integration of industry,academia,and research.To address this issue,enhancing intellectual property protection,revitalizing valid patents,and expanding transformation channels would benefit patients and facilitate hospitals'high-quality development,injecting new vitality into the health industry.
7.Proton beam range verification algorithm for pixelated prompt gamma-ray imaging detector
Liwang YANG ; Haifeng OU ; Jinlong WANG ; Xiaoguang WU ; Ziyang HE ; Jian'an ZOU ; Yun ZHENG ; Congbo LI ; Shaoxiong GUAN ; Jing SHI ; Jinze LI ; Yunqiu LI ; Rui HONG ; Hao'en CHANG ; Mengting WANG ; Kaijie WEI
Chinese Journal of Medical Physics 2025;42(3):281-287
In proton therapy,prompt gamma-ray imaging is considered as one of the most promising methods for assessing proton beam range.Prompt gamma-ray imaging detector evaluates the proton beam range based on the prompt gamma-ray distribution obtained by the prompt gamma-ray imaging system,which enables high-precision measurement of the proton beam range.Herein a proton beam range verification algorithm is designed for the newly developed prototype of the range verification detector(pixelated prompt gamma-ray imaging detector),which verifies the range estimation accuracy of the prototype for different phantoms and different energies of homogeneous media through Monte Carlo simulation.The results show that the accuracy of the proton beam range verification algorithm is within 0.5 mm of the safety margin error of the Bragg peak,and the measurement accuracy is significantly improved with the increase of the number of protons,indicating that the prototype algorithm is feasible for proton beam range verification.
8.Analysis of the current status of domestic medical drainage tube patents based on patent information mining
Feng MA ; Chuxin CHANG ; Yan LI ; Lengjianghai ZHENG ; Ruimin GONG ; Juntao DUAN ; Rongqian WU ; Yi LV ; Xiaoyun KANG
Journal of Xi'an Jiaotong University(Medical Sciences) 2025;46(6):1013-1019
Objective To analyze the current status and emerging technology trends in domestic medical drainage tube patents,so as to explore possible factors for low patent conversion rates.Methods Patents associated with"drainage tube","medical drainage tube","surgical drainage tube"and related terms were retrieved from the National Intellectual Property Administration Database and the Innojoy Patent Search Engine,covering the period from 2010 to 2020.Screening and visual analysis were conducted using Excel and SPSS 27.0.Results A total of 2 895 relevant patents were identified,comprising 2 489 utility model patents,367 invention patents and 39 design patents.The number of patent applications demonstrated a year-on-year growth trend,with a higher concentration in eastern coastal regions and provinces housing numerous top-tier hospitals and medical institutions.Approximately 49.26%of the patents filed by individuals were affiliated with hospitals,universities,or enterprises.Innovation hotspots included the design,functionality,performance,and safety aspects of drainage tubes and probes.Of the patents,72.61%were invalid,and 61.73%had a survival period of three years or less.Only 5.15%were commercially utilized through transfers,pledges,or licensing.Conclusion Domestic patent applications for medical drainage tubes have seen rapid growth,with a focus on enhancing tube structures such as sleeves,balloons,drainage holes,and threaded designs.However,the unsatisfactory situation of patent conversion and operation have been mainly limited by factors such as weak core technology of patents,insufficient awareness of achievements conversion,poor operation of patent conversion mechanism,insufficient market promotion,and insufficient integration of industry,academia,and research.To address this issue,enhancing intellectual property protection,revitalizing valid patents,and expanding transformation channels would benefit patients and facilitate hospitals'high-quality development,injecting new vitality into the health industry.
9.Proton beam range verification algorithm for pixelated prompt gamma-ray imaging detector
Liwang YANG ; Haifeng OU ; Jinlong WANG ; Xiaoguang WU ; Ziyang HE ; Jian'an ZOU ; Yun ZHENG ; Congbo LI ; Shaoxiong GUAN ; Jing SHI ; Jinze LI ; Yunqiu LI ; Rui HONG ; Hao'en CHANG ; Mengting WANG ; Kaijie WEI
Chinese Journal of Medical Physics 2025;42(3):281-287
In proton therapy,prompt gamma-ray imaging is considered as one of the most promising methods for assessing proton beam range.Prompt gamma-ray imaging detector evaluates the proton beam range based on the prompt gamma-ray distribution obtained by the prompt gamma-ray imaging system,which enables high-precision measurement of the proton beam range.Herein a proton beam range verification algorithm is designed for the newly developed prototype of the range verification detector(pixelated prompt gamma-ray imaging detector),which verifies the range estimation accuracy of the prototype for different phantoms and different energies of homogeneous media through Monte Carlo simulation.The results show that the accuracy of the proton beam range verification algorithm is within 0.5 mm of the safety margin error of the Bragg peak,and the measurement accuracy is significantly improved with the increase of the number of protons,indicating that the prototype algorithm is feasible for proton beam range verification.
10.Ultrasound radiomics combined with machine learning for early diagnosis of seronegative hashimoto’s thyroiditis
Wenjun WU ; Chang LIU ; Shengsheng YAO ; Daming LIU ; Yuan LUO ; Yihan SUN ; Ting RUAN ; Mengyou LIU ; Li SHI ; Mingming XIAO ; Qi ZHANG ; Zhengshuai LIU ; Xingai JU ; Jiahao WANG ; Xiang FEI ; Li LU ; Yang GAO ; Ying ZHANG ; Liying GONG ; Xuanyu CHEN ; Wanli ZHENG ; Xiali NIU ; Xiao YANG ; Huimei CAO ; Shijie CHANG ; Zuoxin MA ; Jianchun CUI
Chinese Journal of Endocrine Surgery 2025;19(3):313-319
Objective:To evaluate the value of ultrasound radiomics combined with machine learning for early diagnosis of seronegative Hashimoto’s thyroiditis (SN-HT) .Methods:This retrospective study included 164 patients from Liaoning Provincial People’s Hospital , Lixin County People’s Hospital, Linghai Dalinghe Hospital, Fengcheng Phoenix Hospital, who underwent thyroidectomy for solitary nodules with normal thyroid function between Nov. 2016 and Jan. 2024. Postoperative pathology confirmed Hashimoto’s thyroiditis (HT) in some cases, who were further categorized into antibody-positive and antibody-negative groups based on serum antibody status. Patients without Hashimoto’s thyroiditis served as the control group. A total of 298 ultrasound images were analyzed. Radiomics features were extracted from hypoechoic non-nodular areas within 0.5 cm surrounding the tumor. Two senior pathologists and two senior ultrasound physicians independently assessed lymphocytic infiltration, eosinophilic changes of follicular epithelium, and the proportion of hypoechoic areas in pathology and ultrasound images, respectively. A machine learning model, CCH-NET, was developed using linear regression and t-distributed stochastic neighbor embedding (t-SNE) techniques. The dataset was divided into a training set (80%) and a validation set (20%) to compare the diagnostic accuracy of CCH-NET with that of senior ultrasound physicians. Results:In internal validation, CCH-NET achieved a diagnostic accuracy of 88.89% for both antibody-positive and antibody-negative groups, significantly higher than the 66.67% accuracy of senior ultrasound physicians ( P<0.01). In external validation, CCH-NET achieved 75.00% and 66.67% accuracy for the two groups, compared to 50.00% by senior ultrasound physicians. For the control group, both methods achieved 93.33% accuracy. The AUC of CCH-NET was 0.848, outperforming senior ultrasound physicians (0.681) ,demonstrating superior diagnostic performance. Conclusion:The radiomics-based CCH-NET model, using non-nodular hypoechoic areas as a specific indicator, can accurately identify early SN-HT in euthyroid patients. It significantly outperforms senior ultrasound physicians, improving diagnostic accuracy and reducing missed diagnoses.

Result Analysis
Print
Save
E-mail