1.Construction of core outcome set for clinical research on traditional Chinese medicine treatment of simple obesity.
Tong-Tong WU ; Yan YU ; Qian HUANG ; Xue-Yin CHEN ; Fu-Ming-Xiang LIU ; Li-Hong YANG ; Chang-Cai XIE ; Shao-Nan LIU ; Yu CHEN ; Xin-Feng GUO
China Journal of Chinese Materia Medica 2025;50(12):3423-3430
Following the core outcome set standards for development(COS-STAD), this study aims to construct core outcome set(COS) for clinical research on traditional Chinese medicine(TCM) treatment of simple obesity. Firstly, a comprehensive review was conducted on the randomized controlled trial(RCT) and systematic review(SR) about TCM treatment of simple obesity that were published in Chinese and English databases to collect reported outcomes. Additional outcomes were obtained through semi-structured interviews with patients and open-ended questionnaire surveys for clinicians. All the collected outcomes were then merged and organized as an initial outcome pool, and then a preliminary list of outcomes was formed after discussion by the working group. Subsequently, two rounds of Delphi surveys were conducted with clinicians, methodology experts, and patients to score the importance of outcomes in the list. Finally, a consensus meeting was held to establish the COS for clinical research on TCM treatment of simple obesity. A total of 221 RCTs and 12 SRs were included, and after integration of supplementary outcomes, an initial outcome pool of 141 outcomes were formed. Following discussions in the steering advisory group meeting, a preliminary list of 33 outcomes was finalized, encompassing 9 domains. Through two rounds of Delphi surveys and a consensus meeting, the final COS for clinical research on TCM treatment of simple obesity was determined to include 8 outcomes: TCM symptom scores, body mass index(BMI), waist-hip ratio, waist circumference, visceral fat index, body fat rate, quality of life, and safety, which were classified into 4 domains: TCM-related outcomes, anthropometric measurements, quality of life, and safety. This study has preliminarily established a COS for clinical research on TCM treatment of simple obesity. It helps reduce the heterogeneity in the selection and reporting of outcomes in similar clinical studies, thereby improving the comparability of research results and the feasibility of meta-analysis and providing higher-level evidence support for clinical practice.
Humans
;
Obesity/therapy*
;
Medicine, Chinese Traditional
;
Randomized Controlled Trials as Topic
;
Treatment Outcome
;
Drugs, Chinese Herbal/therapeutic use*
2.Clinical trial of Morinda officinalis oligosaccharides in the continuation treatment of adults with mild and moderate depression
Shu-Zhe ZHOU ; Zu-Cheng HAN ; Xiu-Zhen WANG ; Yan-Qing CHEN ; Ya-Ling HU ; Xue-Qin YU ; Bin-Hong WANG ; Guo-Zhen FAN ; Hong SANG ; Ying HAI ; Zhi-Jie JIA ; Zhan-Min WANG ; Yan WEI ; Jian-Guo ZHU ; Xue-Qin SONG ; Zhi-Dong LIU ; Li KUANG ; Hong-Ming WANG ; Feng TIAN ; Yu-Xin LI ; Ling ZHANG ; Hai LIN ; Bin WU ; Chao-Ying WANG ; Chang LIU ; Jia-Fan SUN ; Shao-Xiao YAN ; Jun LIU ; Shou-Fu XIE ; Mao-Sheng FANG ; Wei-Feng MI ; Hong-Yan ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(6):815-819
Objective To observe the efficacy and safety of Morinda officinalis oligosaccharides in the continuation treatment of mild and moderate depression.Methods An open,single-arm,multi-center design was adopted in our study.Adult patients with mild and moderate depression who had received acute treatment of Morinda officinalis oligosaccharides were enrolled and continue to receive Morinda officinalis oligosaccharides capsules for 24 weeks,the dose remained unchanged during continuation treatment.The remission rate,recurrence rate,recurrence time,and the change from baseline to endpoint of Hamilton Depression Scale(HAMD),Hamilton Anxiety Scale(HAMA),Clinical Global Impression-Severity(CGI-S)and Arizona Sexual Experience Scale(ASEX)were evaluated.The incidence of treatment-related adverse events was reported.Results The scores of HAMD-17 at baseline and after treatment were 6.60±1.87 and 5.85±4.18,scores of HAMA were 6.36±3.02 and 4.93±3.09,scores of CGI-S were 1.49±0.56 and 1.29±0.81,scores of ASEX were 15.92±4.72 and 15.57±5.26,with significant difference(P<0.05).After continuation treatment,the remission rate was 54.59%(202 cases/370 cases),and the recurrence rate was 6.49%(24 cases/370 cases),the recurrence time was(64.67±42.47)days.The incidence of treatment-related adverse events was 15.35%(64 cases/417 cases).Conclusion Morinda officinalis oligosaccharides capsules can be effectively used for the continuation treatment of mild and moderate depression,and are well tolerated and safe.
3.Whole genome analysis of a Coxsackievirus A4 strain from Yunnan
Jun-Wei CHEN ; Chang-Zeng FENG ; Zhao-Yang CHU ; Yu-Han LIU ; Ming ZHANG ; Li LI ; Shao-Hui MA
Chinese Journal of Infection Control 2024;23(9):1061-1069
Objective To understand the whole genome sequence characteristics of a Coxsackievirus A4(CVA4)isolated from Yunnan,China in 2022,and explore the phylogenetic characteristics of CVA4.Methods The whole genome sequence of CVA4 isolate 194R3/YN/CHN/2022 was amplified and sequenced,and the phylogenetic tree of CVA4 isolate was constructed by using Mega 7.0,Geneious 9.1.4 and Simplot 3.5.1 softwares.The whole ge-nome sequence characteristics were analyzed.Results The 194R3/YN/CHN/2022 isolate was identified as CVA4,belonging to the C2 gene subtype,which was consistent with the dominant gene subtype in recent years in China.Recombination analysis showed that recombination of CVA4 virus isolate with EVA114 prototype(V13-0285),CVA16 prototype(G-10),and CVA14 prototype(G-14)at the non-structural coding regions of P2 and P3 may have occurred.Conclusion The 194R3/YN/CHN/2022 isolated from Yunnan belongs to the C2 gene subtype,which is the prevalent CVA4 in China,but with certain mutations.
4.Research on Electrochemical Chemical Oxygen Demand Sensor
Shan YUN ; Lei WANG ; Li-Guo WAN ; Zhen-Yu PENG ; Hong-Chang WANG ; Jun-Feng ZHAI ; Shao-Jun DONG
Chinese Journal of Analytical Chemistry 2024;52(9):1298-1306
An electrochemical chemical oxygen demand(COD)sensor was proposed based on a FTO/TiO2/PbO2 electrode and a thin-layer electrochemical cell.The FTO/TiO2/PbO2 electrode was characterized by X-ray photoelectronic spectroscopy(XPS),X-ray diffraction(XRD)spectroscopy and electrochemical technique,and the results indicated that the rapid decrease in the output signals of the electrochemical COD sensor could be attributed to oxidation of PbSO4 occurring on the surface of FTO/TiO2/PbO2 electrode.The PbO2 deposition time and concentration of Na2SO4 were further optimized and then the electrochemical COD sensor was challenged by real samples including laker water sample,river water sample and wastewater sample.The evolution trend of signals of the electrochemical COD sensor in response to lake and river water samples was identical with that obtained with the standard method(HJ/T399-2007,Water quality-determination of the chemical oxygen demand-fast digestion-spectrophotometric method).The electrochemical COD sensor exhibited significant increase in the signal intensity after the samples were switched from lake water to wastewater sample,and a mean value of 32.5 mg/L with relative standard deviation(RSD)of 6.8%were obtained after measuring 45 times the wastewater with COD value of 30 mg/L under a sampling interval of 400 s.The as-prepared electrochemical COD sensor possessed good promise in regular monitoring of COD,discharge of wastewater and industrial process control,with advantages such as a small sampling interval,mild reaction conditions and no requirement of toxic and harmful chemical reagents.
5.Coronary artery perforation after using shockwave balloon during percutaneous coronary intervention treatment:a case report
Chen-Ji XU ; Fei LI ; Fa ZHENG ; Bin ZHANG ; Feng-Xia QU ; Jian-Meng WANG ; Ya-Qun ZHOU ; Xian-Liang LI ; Song-Tao WANG ; Yan SHAO ; Chang-Hong LU
Chinese Journal of Interventional Cardiology 2024;32(7):405-408
Coronary perforation is when a contrast agent or blood flows outside a blood vessel through a tear in a coronary artery.In this case,we reported a case of percutaneous coronary intervention for coronary calcified lesions,which led to iatrogenic coronary perforation and cardiac tamponade after the use of Shockwave balloon to treat intracoronary calcified nodules,and the management of PCI-related CAP was systematically reviewed through the literature.
6.Simulation design and experimental study of magnetic stimulation coil for robot pigeon.
Menghua XU ; Xin PU ; Ming CHANG ; Yang SONG ; Fuzhe MA ; Ruituo HUAI ; Junqing YANG ; Hui CHANG ; Feng SHAO ; Hui WANG
Journal of Biomedical Engineering 2023;40(1):141-148
To explore the feasibility of applying magnetic stimulation technology to the movement control of animal robots, the influence of coil radius, number of turns and other factors on the intensity, depth and focus of magnetic stimulation was simulated and analyzed for robot pigeons. The coil design scheme was proposed. The coil was placed on the head and one of the legs of the pigeon, and the leg electromyography (EMG) was recorded when magnetic stimulation was performed. Results showed that the EMG was significantly strengthened during magnetic stimulation. With the reduction of the output frequency of the magnetic stimulation system, the output current was increased and the EMG was enhanced accordingly. Compared with the brain magnetic stimulation, sciatic nerve stimulation produced a more significant EMG enhancement response. This indicated that the magnetic stimulation system could effectively modulate the functions of brain and peripheral nerves by driving the coil. This study provides theoretical and experimental guidance for the subsequent optimization and improvement of practical coils, and lays a preliminary theoretical and experimental foundation for the implementation of magnetic stimulation motion control of animal robots.
Animals
;
Columbidae
;
Robotics
;
Motion
;
Brain
;
Magnetic Phenomena
7.Study on emergency management mechanism of drug volume-based procurement
Jing SHAO ; Yun LU ; Feng CHANG
China Pharmacy 2023;34(8):902-906
OBJECTIVE To provide reference for the normalization of drug volume-based procurement (hereinafter referred to as “VBP”) and the establishment of local emergency management mechanism. METHODS Based on the equilibrium theory of the whole process of emergency management with Chinese conditions, referring to the “6+1” stage model, the emergency management mechanism of VBP was constructed; 21 provincial-level procurement projects in China from 2019 to 2022 were evaluated accordingly. RESULTS The emergency management mechanism of VBP including 14 measures in 7 stages of preparation, prevention, mitigation, response, recovery, learning and monitoring was successfully constructed. The total score of the 21 provincial-level procurement projects was 3 to 11 points, and the average score of each project in the past 4 years fluctuated slightly within 6 to 7 points. Among the 5 evaluated stages, the scores of the prevention and response stage were relatively high, followed by the mitigation and preparation stage, and the lowest in the recovery stage. Among the 11 rated emergency management measures, more than half had an average score greater than 0.5, but the average score of “determining alternative enterprise selection methods” was only 0.19. CONCLUSIONS Some emergency management measures of drug VBP are lacking, and the emergency management mechanism still needs to be perfected, which is not conducive to the development of emergency management work. The procurement organizer should focus on building a complete emergency management mechanism covering all stages, and clarify the specific measures at each stage, so as to ensure procurement effective and good in operation.
8.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
9.Antimicrobial resistance and genomic characterization of Campylobacter isolates recovered from retailed poultry meat samples in 20 provinces of China in 2020.
Chang Wei WANG ; Yao BAI ; Shao Ting LI ; Zi Xin PENG ; Da Jin YANG ; Yin Ping DONG ; Jing XIAO ; Wei WANG ; Feng Qin LI
Chinese Journal of Preventive Medicine 2023;57(12):2086-2094
Objective: To understand the antimicrobial resistance and genome characteristics of Campylobacter isolates recovered from retailed poultry meat samples in 20 provinces in China in 2020. Methods: In 2020, 265 Campylobacter strains including 244 Campylobacter jejuni and 21 Campylobacter coli collected from retailed poultry meat samples in China were tested for antimicrobial resistance to 9 antimicrobial compounds by using the agar dilution method. Forty-two selected isolates were sent for whole genome sequencing and 38 high-quality genomes were analyzed for their antimicrobial resistance genes, virulence genes, sequence types and genetic diversity. Results: The resistance rates of Campylobacter isolates from poultry meats to tetracycline, nalidixic acid and ciprofloxacin were the highest (84%-100%), with 53.2% of the isolates showing multidrug resistance in this study. The resistance rates of C. coli to erythromycin, azithromycin, telithromycin, gentamicin and clindamycin were significantly higher than those of C. jejuni (P<0.05). The resistance genes conferring resistance to β-lactams (100%, 38/38), quinolones (94.7%, 36/38), tetracycline (81.6%, 31/38) and aminoglycosides (50%, 19/38) were the most frequently detected among 38 Campylobacter genomes. C. jejuni carried more virulence genes than C. coli. In total, 19 and 17 sequence types (ST) were obtained from 20 sequenced C. jejuni and 18 C. coli isolates, respectively, including 5 novel STs. The isolates showed a high genetic diversity based on their sequence types. Conclusion: The phenomenon of antimicrobial resistance in Campylobacter from poultry meat sources in China is relatively serious, and resistance and virulence genes are widely distributed in Campylobacter. There is genetic diversity in Campylobacter.
Humans
;
Animals
;
Anti-Bacterial Agents/pharmacology*
;
Campylobacter/genetics*
;
Poultry
;
Drug Resistance, Bacterial/genetics*
;
Genomics
;
China
;
Tetracycline
10.Antimicrobial resistance and genomic characterization of Campylobacter isolates recovered from retailed poultry meat samples in 20 provinces of China in 2020.
Chang Wei WANG ; Yao BAI ; Shao Ting LI ; Zi Xin PENG ; Da Jin YANG ; Yin Ping DONG ; Jing XIAO ; Wei WANG ; Feng Qin LI
Chinese Journal of Preventive Medicine 2023;57(12):2086-2094
Objective: To understand the antimicrobial resistance and genome characteristics of Campylobacter isolates recovered from retailed poultry meat samples in 20 provinces in China in 2020. Methods: In 2020, 265 Campylobacter strains including 244 Campylobacter jejuni and 21 Campylobacter coli collected from retailed poultry meat samples in China were tested for antimicrobial resistance to 9 antimicrobial compounds by using the agar dilution method. Forty-two selected isolates were sent for whole genome sequencing and 38 high-quality genomes were analyzed for their antimicrobial resistance genes, virulence genes, sequence types and genetic diversity. Results: The resistance rates of Campylobacter isolates from poultry meats to tetracycline, nalidixic acid and ciprofloxacin were the highest (84%-100%), with 53.2% of the isolates showing multidrug resistance in this study. The resistance rates of C. coli to erythromycin, azithromycin, telithromycin, gentamicin and clindamycin were significantly higher than those of C. jejuni (P<0.05). The resistance genes conferring resistance to β-lactams (100%, 38/38), quinolones (94.7%, 36/38), tetracycline (81.6%, 31/38) and aminoglycosides (50%, 19/38) were the most frequently detected among 38 Campylobacter genomes. C. jejuni carried more virulence genes than C. coli. In total, 19 and 17 sequence types (ST) were obtained from 20 sequenced C. jejuni and 18 C. coli isolates, respectively, including 5 novel STs. The isolates showed a high genetic diversity based on their sequence types. Conclusion: The phenomenon of antimicrobial resistance in Campylobacter from poultry meat sources in China is relatively serious, and resistance and virulence genes are widely distributed in Campylobacter. There is genetic diversity in Campylobacter.
Humans
;
Animals
;
Anti-Bacterial Agents/pharmacology*
;
Campylobacter/genetics*
;
Poultry
;
Drug Resistance, Bacterial/genetics*
;
Genomics
;
China
;
Tetracycline

Result Analysis
Print
Save
E-mail