1.Historical Perspectives of the Korean Society for Thoracic and Cardiovascular Surgery: Sung Nok Hong (1927–2017) Who Performed the First Coronary Artery Bypass Graft in Korea
Doo Yun LEE ; Hyo Chae PAIK ; Byung Chul CHANG ; Meyun-Shick KANG ; Kook-Yang PARK
Journal of Chest Surgery 2025;58(2):73-76
2.Historical Perspectives of the Korean Society for Thoracic and Cardiovascular Surgery: Sung Nok Hong (1927–2017) Who Performed the First Coronary Artery Bypass Graft in Korea
Doo Yun LEE ; Hyo Chae PAIK ; Byung Chul CHANG ; Meyun-Shick KANG ; Kook-Yang PARK
Journal of Chest Surgery 2025;58(2):73-76
3.Historical Perspectives of the Korean Society for Thoracic and Cardiovascular Surgery: Sung Nok Hong (1927–2017) Who Performed the First Coronary Artery Bypass Graft in Korea
Doo Yun LEE ; Hyo Chae PAIK ; Byung Chul CHANG ; Meyun-Shick KANG ; Kook-Yang PARK
Journal of Chest Surgery 2025;58(2):73-76
4.Usefulness of Direct Peroral Cholangioscopy Using a Multibending Ultraslim Endoscope for the Management of Intrahepatic Bile Duct Lesions (with Videos)
Won Myung LEE ; Jong Ho MOON ; Yun Nah LEE ; Chang Wook MIN ; Il Sang SHIN ; Jun Ho MYEONG ; Hee Kyung KIM ; Jae Kook YANG ; Tae Hoon LEE
Gut and Liver 2024;18(2):358-364
Background/Aims:
Peroral cholangioscopy (POC) has been used to assess intrahepatic duct (IHD) lesions but with a limited role. A new multibending (MB) ultraslim endoscope has been designed to improve POC performance. We evaluated the usefulness of POC using the MB ultraslim endoscope for the management of IHD lesions.
Methods:
Between March 2017 and March 2020, 22 patients underwent direct POC using the MB ultraslim endoscope for IHD lesions documented by previous imaging or cholangiopancreatography. The primary outcome was technical success of POC, and secondary outcomes were technical success of POC-guided interventions, median procedure time, and POC-related adverse events.
Results:
The technical success rate for POC using the MB ultraslim endoscope for IHD lesions was 95.5% (21/22). Free-hand insertion was successful in 95.2% (20/21). The overall technical success rate for POC-guided intervention was 100% (21/21), including nine diagnostic and 12 therapeutic procedures (eight direct stone removal and four intraductal lithotripsies). The median procedure time was 29 minutes (range, 9 to 79 minutes). There were no procedure-related adverse events.
Conclusions
Direct POC using the MB ultraslim endoscope allows direct visualization of IHD lesions and may be useful for diagnosis and therapeutic management in selected patients.
5.Telemedicine Protocols for the Management of Patients with Acute Spontaneous Intracerebral Hemorrhage in Rural and Medically Underserved Areas in Gangwon State : Recommendations for Doctors with Less Expertise at Local Emergency Rooms
Hyo Sub JUN ; Kuhyun YANG ; Jongyeon KIM ; Jin Pyeong JEON ; Sun Jeong KIM ; Jun Hyong AHN ; Seung Jin LEE ; Hyuk Jai CHOI ; In Bok CHANG ; Jeong Jin PARK ; Jong-Kook RHIM ; Sung-Chul JIN ; Sung Min CHO ; Sung-Pil JOO ; Seung Hun SHEEN ; Sang Hyung LEE ;
Journal of Korean Neurosurgical Society 2024;67(4):385-396
Previously, we reported the concept of a cloud-based telemedicine platform for patients with intracerebral hemorrhage (ICH) at local emergency rooms in rural and medically underserved areas in Gangwon state by combining artificial intelligence and remote consultation with a neurosurgeon. Developing a telemedicine ICH treatment protocol exclusively for doctors with less ICH expertise working in emergency rooms should be part of establishing this system. Difficulties arise in providing appropriate early treatment for ICH in rural and underserved areas before the patient is transferred to a nearby hub hospital with stroke specialists. This has been an unmet medical need for decade. The available reporting ICH guidelines are realistically possible in university hospitals with a well-equipped infrastructure. However, it is very difficult for doctors inexperienced with ICH treatment to appropriately select and deliver ICH treatment based on the guidelines. To address these issues, we developed an ICH telemedicine protocol. Neurosurgeons from four university hospitals in Gangwon state first wrote the guidelines, and professors with extensive ICH expertise across the country revised them. Guidelines and recommendations for ICH management were described as simply as possible to allow more doctors to use them easily. We hope that our effort in developing the telemedicine protocols will ultimately improve the quality of ICH treatment in local emergency rooms in rural and underserved areas in Gangwon state.
6.Results of a Survey on Current Status and Demand for the Improvement of the Korean Journal of Pancreas and Biliary Tract
Tae Young PARK ; Jimin HAN ; Tae Hoon LEE ; Jae Kook YANG ; Hyeong Seok NAM ; Jun Hyuk SON ; Hoonsub SO ; Eaum Seok LEE ; Chi Hyuk OH ; Jun Hyung LEE ; Jong-Chan LEE ; Min Jae YANG ; Hee Seun LEE ; Seung Bae YOON ; Jae Hyuck CHANG
Korean Journal of Pancreas and Biliary Tract 2024;29(2):64-67
7.Development of Efficient Brain Age Estimation Method Based on Regional Brain Volume From Structural Magnetic Resonance Imaging
Sunghwan KIM ; Sheng-Min WANG ; Dong Woo KANG ; Yoo Hyun UM ; Hyeonsik YANG ; Hyunji LEE ; Regina EY KIM ; Donghyeon KIM ; Chang Uk LEE ; Hyun Kook LIM
Psychiatry Investigation 2024;21(1):37-43
Objective:
We aimed to create an efficient and valid predicting model which can estimate individuals’ brain age by quantifying their regional brain volumes.
Methods:
A total of 2,560 structural brain magnetic resonance imaging (MRI) scans, along with demographic and clinical data, were obtained. Pretrained deep-learning models were employed to automatically segment the MRI data, which enabled fast calculation of regional brain volumes. Brain age gaps for each subject were estimated using volumetric values from predefined 12 regions of interest (ROIs): bilateral frontal, parietal, occipital, and temporal lobes, as well as bilateral hippocampus and lateral ventricles. A larger weight was given to the ROIs having a larger mean volumetric difference between the cognitively unimpaired (CU) and cognitively impaired group including mild cognitive impairment (MCI), and dementia groups. The brain age was predicted by adding or subtracting the brain age gap to the chronological age according to the presence or absence of the atrophy region.
Results:
The study showed significant differences in brain age gaps among CU, MCI, and dementia groups. Furthermore, the brain age gaps exhibited significant correlations with education level and measures of cognitive function, including the clinical dementia rating sum-of-boxes and the Korean version of the Mini-Mental State Examination.
Conclusion
The brain age that we developed enabled fast and efficient brain age calculations, and it also reflected individual’s cognitive function and cognitive reserve. Thus, our study suggested that the brain age might be an important marker of brain health that can be used effectively in real clinical settings.
8.Efficacy and safety of 1 L polyethylene glycol plus ascorbic acid for bowel preparation in elderly: comparison with oral sulfate solution
Ki Young LIM ; Kyeong Ok KIM ; Eun Young KIM ; Yoo Jin LEE ; Byung Ik JANG ; Sung Kook KIM ; Chang Heon YANG ;
The Korean Journal of Internal Medicine 2023;38(5):651-660
Background/Aims:
Recently, 1 L of polyethylene glycol (PEG) plus ascorbic acid (Asc) has been introduced in Korea as a colonoscopy preparation agent. Data on its efficacy and safety in older adults have been limited. We aimed to evaluate the safety and efficacy of 1 L PEG/Asc in older adults by comparing it with oral sulfate solution (OSS).
Methods:
A prospective multicenter randomized study was conducted with subjects aged ≥ 65 years who underwent colonoscopy. The participants were randomized to receive 1 L PEG/Asc or OSS. The primary endpoint was successful bowel preparation, defined as total Boston Bowel Preparation Scale ≥ 6, and ≥ 2 at each segment. Patient satisfaction, adverse events, and renal function changes were compared between the groups.
Results:
Among the 106 patients, 104 were finally included in the analysis. Overall, successful bowel preparation was achieved in 96.2% of both 1 L PEG/Asc and OSS groups. The satisfaction scores for taste, total amount ingested, overall feeling, and willingness to repeat the same regimen were not significantly different between the groups. Adverse events of moderate or higher severity occurred in 16 and 10 cases in the 1 L PEG/Asc and OSS group, respectively. There were no significant changes in electrolyte levels or renal function from baseline.
Conclusions
The successful bowel preparation rate was > 90% in both groups without severe adverse effects and significant changes in renal function. As a new low-dose preparation regimen for colonoscopy in older adults, 1 L PEG/Asc, is as effective and safe as OSS.
9.Efficacy Analysis of Suprapapillary versus Transpapillary Self-Expandable Metal Stents According to the Level of Obstruction in Malignant Extrahepatic Biliary Obstruction
Sung Yong HAN ; Tae Hoon LEE ; Sung Ill JANG ; Dong Uk KIM ; Jae Kook YANG ; Jae Hee CHO ; Min Je SUNG ; Chang-Il KWON ; Jin-Seok PARK ; Seok JEONG ; Don Haeng LEE ; Sang-Heum PARK ; Dong Ki LEE
Gut and Liver 2023;17(5):806-813
Background/Aims:
The use of a self-expandable metal stent (SEMS) is recommended for unresectable malignant biliary obstruction (MBO). Stent-related adverse events might differ according to the position of the stent through the ampulla of Vater (AOV). We retrospectively evaluated SEMS patency and adverse events according to the position of the SEMS.
Methods:
In total, 280 patients who underwent endoscopic SEMS placement due to malignant distal biliary obstruction were analyzed retrospectively. Suprapapillary and transpapillary SEMS insertions were performed on 51 patients and 229 patients, respectively.
Results:
Between the suprapapillary group (SPG) and transpapillary group (TPG), the stent patency period was not significantly different (median [95% confidence interval]: 107 days [82.3 to 131.7] vs 120 days [99.3 to 140.7], p=0.559). There was also no significant difference in the rate of adverse events. In subgroup analysis, the stent patency for an MBO located within 2 cm from the AOV was found to be significantly shorter than that for an MBO located more than 2 cm from the AOV in the SPG (64 days [0 to 160.4] vs 127 days [82.0 to 171.9], p<0.001) and TPG (87 days [52.5 to 121.5] vs 130 [97.0 to 162.9], p<0.001). Patients with an MBO located within 2 cm from the AOV in both groups had a higher percentage of duodenal invasion (SPG: 40.0% vs 4.9%, p=0.002; TPG: 28.6% vs 2.9%, p<0.001) than patients with an MBO located more than 2 cm from the AOV.
Conclusions
The SPG and TPG showed similar results in terms of stent patency and rate of adverse events. However, patients with an MBO located within 2 cm from the AOV had a higher percentage of duodenal invasion with shorter stent patency than those with an MBO located more than 2 cm from the AOV, regardless of stent position.
10.Comparing the Procedural and Clinical Outcomes of Sapien XT and Sapien 3Valves in Transcatheter Aortic Valve Replacement in Korean Patients
Hyungdon KOOK ; Duck Hyun JANG ; Kyung-Sook YANG ; Hyung Joon JOO ; Jae Hyoung PARK ; Soon Jun HONG ; Do-Sun LIM ; Seung-Hyuk CHOI ; Young Jin CHOI ; Kiyuk CHANG ; Cheol Woong YU
Korean Circulation Journal 2020;50(10):907-922
Background and Objectives:
The Sapien 3 (S3) valve has not been compared to the Sapien XT (SXT) valve in Korea. We compared procedural and clinical outcomes between the 2 devices.
Methods:
A total of 189 patients who underwent transcatheter aortic valve replacement (TAVR) with S3 (n=95) or SXT (n=94) valve was analyzed. The primary endpoint was cardiovascular mortality at 1 year. The median follow-up duration was 438 days.
Results:
The Society of Thoracic Surgeons score was similar between the 2 groups. The device success rate (90.4% vs. 97.9%; p=0.028) was higher in the S3 than in the SXT. The S3 showed significantly fewer cases of moderate or severe paravalvular leakage (PVL) (16.7% vs.0.0%; p=0.001) than the SXT. However, effective orifice area (EOA) (2.07±0.61 vs. 1.70±0.49 cm2 ; p<0.001) was smaller in the S3. Multivariable Cox regression analysis showed the S3 was associated with significantly fewer cardiovascular mortality at 1 year compared to the SXT (5.4% vs. 1.1%; hazard ratio, 0.031; 95% confidence interval, 0.001–0.951; p=0.047). Periprocedural complication rates, composite of disabling stroke or all-cause mortality, allcause mortality, and disabling stroke at 1 year were similar between the 2 groups.
Conclusions
Cardiovascular mortality was lower in the S3 group than in the SXT group over 1 year of follow-up. The reduction in PVL was attributed to the higher device success rate of TAVR with the S3 valve. However, the benefit of S3 obtained at the expense of reduced EOA should be meticulously re-evaluated in larger studies during long-term follow-up.

Result Analysis
Print
Save
E-mail