1.Constructing core outcome set for clinical research on traditional Chinese medicine treatment of post-stroke aphasia.
Ya-Nan MA ; Min-Jie XU ; Yu-Ai YANG ; Jian CHEN ; Qiao-Sheng REN ; Ying LI ; Jing-Ling CHANG
China Journal of Chinese Materia Medica 2025;50(1):238-253
According to the principle and current domestic and international construction processes of core outcome set(COS) and the characteristics of post-stroke aphasia, this study built COS with evidence-based support for traditional Chinese medicine(TCM) treatment of post-stroke aphasia. Firstly, a comprehensive review was conducted on the articles about the TCM treatment of post-stroke aphasia that were published in the four major Chinese databases, three major English databases, and three clinical registration centers over the past five years. The articles were analyzed and summarized, on the basis of which the main part of the COS for clinical research on the TCM treatment of post-stroke aphasia was formed. Secondly, clinical doctors and related nursing personnel were interviewed, and important outcome indicators in the clinical diagnosis and treatment process were supplemented to form a pool of core outcome indicators. Two rounds of Delphi surveys were carried out to score the importance of the core outcome indicators in the pool. Finally, a consensus meeting of experts was held to establish the COS for clinical research on the TCM treatment of post-stroke aphasia. The final COS included a total of 268 studies [236 randomized controlled trials(RCTs), 21 Meta-analysis, and 11 clinical registration protocols] and 20 open questionnaire survey results. After two rounds of Delphi surveys, a total of 14 outcome indicators and their corresponding measurement tools were included in the expert consensus meeting. The final expert consensus meeting determined the COS for post-stroke aphasia, which included 9 indicator domains and 12 outcome indicators.
Humans
;
Aphasia/therapy*
;
Stroke/complications*
;
Medicine, Chinese Traditional
;
Drugs, Chinese Herbal/therapeutic use*
;
Treatment Outcome
2.Quality control in manufacturing process of traditional Chinese medicine (TCM) preparations and its application in evaluation and decision-making of changes in marketed TCM preparations.
Hao CHEN ; Chang-Ming YANG ; Wei HAN ; Jian-Bo QU ; Ping YANG ; Xia CHEN ; Ruo-Jin WANG
China Journal of Chinese Materia Medica 2025;50(9):2589-2595
The manufacturing process is crucial for ensuring the safety and efficacy of traditional Chinese medicine(TCM) preparations. Using advanced technologies, innovative methods, and new equipment tailored for TCM to enhance the quality control of TCM preparations in the manufacturing process helps to ensure the product quality and foster high-quality development of the TCM industry. Upon current technical requirements, such as Guideline for Studies on Pharmaceutical Changes in Marketed Traditional Chinese Medicine Preparations(Trial) and Guideline for Study on Quality Control in Manufacturing Process of Oral Traditional Chinese Medicine Preparations(Trial), this paper analyzes the characteristics and current development of quality control in the manufacturing process of TCM preparations. It also discusses the significant roles that quality control in manufacturing process plays in ensuring the quality consistency and in the evaluation and decision-making of changes in marketed TCM preparations. Furthermore, to benefit the high-quality development of the TCM industry, this paper offers recommendations for improving quality control of TCM preparations in the manufacturing process and implementing new technologies and methods.
Quality Control
;
Drugs, Chinese Herbal/chemistry*
;
Medicine, Chinese Traditional/standards*
;
Decision Making
;
Humans
3.Application of 3D-printed auxiliary guides in adolescent scoliosis surgery.
Dong HOU ; Jian-Tao WEN ; Chen ZHANG ; Jin HUANG ; Chang-Quan DAI ; Kai LI ; Han LENG ; Jing ZHANG ; Shao-Bo YANG ; Xiao-Juan CUI ; Juan WANG ; Xiao-Yun YUAN
China Journal of Orthopaedics and Traumatology 2025;38(11):1119-1125
OBJECTIVE:
To investigate the accuracy and safety of pedicle screw placement using 3D-printed auxiliary guides in scoliosis correction surgery for adolescents.
METHODS:
A retrospective analysis was conducted on the clinical data of 51 patients who underwent posterior scoliosis correction surgery from January 2020 to March 2023. Among them, there were 35 cases of adolescent idiopathic scoliosis and 16 cases of congenital scoliosis. The patients were divided into two groups based on the auxiliary tool used:the 3D-printed auxiliary guide screw placement group (3D printing group) and the free-hand screw placement group (free-hand group, without auxiliary tools). The 3D printing group included 32 patients (12 males and 20 females) with an average age of (12.59±2.60) years;the free-hand group included 19 patients (7 males and 12 females) with an average age of (14.58±3.53) years. The two groups were compared in terms of screw placement accuracy and safety, spinal correction rate, intraoperative blood loss, number of intraoperative fluoroscopies, operation time, hospital stay, and preoperative and last follow-up scores of the Scoliosis Research Society-22 (SRS-22) questionnaire.
RESULTS:
A total of 707 pedicle screws were placed in the two groups, with 441 screws in the 3D printing group and 266 screws in the free-hand group. All patients in both groups successfully completed the surgery. There was a statistically significant difference in operation time between the two groups (P<0.05). The screw placement accuracy rate of the 3D printing group was 95.46% (421/441), among which the Grade A placement rate was 89.34% (394/441);the screw placement accuracy rate of the free-hand group was 86.47% (230/266), with a Grade A placement rate of 73.31% (195/266). There were statistically significant differences in the accuracy of Grade A, B, and C screw placements between the two groups (P<0.05), while no statistically significant differences were observed in intraoperative blood loss, number of fluoroscopies, correction rate, or hospital stay (P>0.05). In the SRS-22 questionnaire scores, the scores of functional status and activity ability, self-image, mental status, and pain of patients in each group at the last follow-up were significantly improved compared with those before surgery (P<0.05), but there were no statistically significant differences in all scores between the two groups (P>0.05).
CONCLUSION
In scoliosis correction surgery, compared with traditional free-hand screw placement, the use of 3D-printed auxiliary guides for screw placement significantly improves the accuracy and safety of screw placement and shortens the operation time.
Humans
;
Male
;
Scoliosis/surgery*
;
Female
;
Adolescent
;
Printing, Three-Dimensional
;
Retrospective Studies
;
Pedicle Screws
;
Child
4.Sensitive Detection of Nitrofurazone by Electrochemical Sensor Based on Platinum Nanoparticles Functionalized Zeolitic Imidazolate Frameworks-derived Porous Carbon and Carbon Nanotubes
Tong CHANG ; Feng-Lin ZHANG ; Mei-Jie GUO ; Yi-Yan BAI ; Jian-Fang QIN ; Hai-Ying YANG
Chinese Journal of Analytical Chemistry 2025;53(11):1908-1920,中插49-中插52
Nitrofurazone(NFZ)is an antibiotic that is used as a veterinary drug in aquaculture.NFZ abuse can lead to a series of environmental and health issues,making it crucial to establish a rapid and highly sensitive method for NFZ detection.In this study,platinum nanoparticle(PtNPs)-loaded zeolitic imidazolate framework(ZIF-8)was used as a precursor,and PtNPs functionalized nitrogen doped porous carbon(NC)was obtained through pyrolysis.Pt@NC was combined with multi-walled carbon nanotubes(MWCNTs)and cast onto a glassy carbon electrode(GCE)surface to construct an electroch-emical sensor.Electrochemical tests revealed that Pt@NC/WCNT/GCE exhibited an electrochemical active area of 0.066 cm2 and a heterogeneous electron transfer rate constant(k0)of 2.03×10-3 cm/s,which were higher than other materials.Compared with the electrodes modified by other materials,the NFZ generated the highest peak current of irreversible reduction peak on the Pt@NC/WCNT/GCE electrode.In comparison with Pt@ZIF-8/WCNT/GCE,after pyrolysis and carbonization treatment,the reduction current of NFZ increased by 2.19 times,and the reduction peak potential shifted positively by 19 mV simultaneously.When compared with NC/WCNT/GCE,the PtNPs in the composite material enhanced the NFZ current by 4.25 times.Additionally,the experimental conditions for detecting NFZ using the sensor were optimized,including the carbonization temperature of Pt@ZIF-8,ratio of Pt@NC to CNT,loading amount of the modified material,and electrolyte pH.Under the optimized conditions,the sensor demonstrated a linear detection range for NFZ of 0.20-240 μmol/L,a sensitivity of 9.995 μA/((μmol/L)?cm2)and a limit of detection(LOD)of 0.06 μmol/L.The sensor exhibited excellent anti-interference capability,good reproducibility,and stability,with spiked recoveries for NFZ in water samples ranging from 94.6%to 105.6%.This study provided a novel electrochemical sensing approach for NFZ detection.
5.Analysis of risk factors for MRI invisible prostate cancer
Yushi HOU ; Mingyu CHANG ; Ruiyu YUE ; Jian SONG ; Xuanhao LI ; Jingcheng LYU ; Yichen ZHU ; Boyu YANG
International Journal of Surgery 2025;52(2):98-108
Objective:To investigate the risk factors for detecting clinically significant prostate cancer (CSPCa) in patients with Prostate Imaging Reporting and Data System (PI-RADS) score≤3 on multi-parameter magnetic resonance imaging (mpMRI).Methods:Retrospective analysis was performed on the case data of 335 patients with suspected prostate cancer and PI-RADS score ≤3 who were admitted to Beijing Friendship Hospital, Capital Medical University from January 2013 to October 2022. All patients underwent 24-needle prostate biopsy. Clinical data such as age, body mass index, past medical history, serological laboratory indicators, and mpMRI imaging data were collected. The patients were grouped according to whether the puncture pathology was CSPCa or not, and the differences in clinical data between the two groups were analyzed by t-test, rank sum test and Chi-test. Multivariate Logistic regression analysis was further used to determine independent risk factors for MRI invisible prostate cancer, and receiver operating characteristics (ROC) curves were drawn. At the same time, further subgroup analysis was conducted based on whether prostate-specific antigen (PSA) was positive before puncture and PI-RADS score, respectively, and the same statistical method was used to further determine the influence of different serological indicators and PI-RADS score on the analysis results of risk factors. Results:Among all patients, 81 were CSPCa patients and 254 were non-CSPCa patients. Multivariate Logistic regression analysis showed that prostate-specific antigen density (PSAD) and PI-RADS score of 3 were independent risk factors for MRI invisible prostate cancer. At the same time, compared with suspected lesions located only in the transitional zone, the incidence of CSPCa in patients with suspected lesions located in the peripheral zone would increase, and the incidence of CSPCa would further increase when suspected lesions were found in both the transitional zone and the peripheral zone. In PSA-negative patients, only suspected lesion location was an independent risk factor for MRI invisible prostate cancer, while in PSA-positive patients, prostate volume, PSAD, and PI-RADS scores were independent risk factors. In subgroup analysis with different PI-RADS scores, suspicious lesions in both the transitional zone and peripheral zone indicate a higher likelihood of CSPCa. For patients with PI-RADS scores of 1 to 2, suspicious lesions in the peripheral zone alone may also indicated CSPCa, while for patients with PI-RADS scores of 3, the lower free prostate-specific antigen/total prostate-specific anti-principle was more accurate in predicting CSPCa.Conclusions:For patients who are clinically suspected of prostate cancer but whose PI-RADS score is less than or equal to 3 points indicated by mpMRI, it is necessary to further focus on the results of different serological indicators according to whether their PSA is positive and PI-RADS score respectively to judge whether patients should receive systemic prostate puncture, instead of using PSA level as a single indication for puncture. At the same time, clinicians should also pay full attention to the location of suspected lesions, when they are located in the peripheral zone, or there are suspected lesions in both the peripheral zone and the transitional zone, the possibility of CSPCa should be fully considered.
6.Research on the establishment of a template of broad informed consent form in Beijing based on the Delphi method
Wenjing XU ; Xueqin WANG ; Jian YANG ; Suhua CHANG ; Siwei SUN ; Hongqiang SUN
Chinese Medical Ethics 2025;38(8):1003-1008
Objective:To establish an element framework and template of broad informed consent applicable to clinical research,and to standardize the collection,storage,and reuse of medical data and biological samples,making them comply with ethical and legal requirements.Methods:A literature review and group discussion were employed to construct the draft of the element framework and template of broad informed consent form.The Delphi expert consultation method was used to conduct two rounds of correspondence with 13 experts in relevant fields to determine the two-level element framework and template of broad informed consent form.Results:The response rates for the two rounds of expert consultation questionnaires were above 90%,the experts'positive coefficients were good,and the coefficients of authority(Cr)were higher than 0.85.In the second round of consultation,the average importance value was≥4.4,the coefficient of variation(CV)was<0.17,and Kendall's W was 0.184(P<0.001),indicating that the expert opinions tended to be consistent.Ultimately,an element framework and template of broad informed consent form was established,consisting of 4 first-level items and 21 second-level items.Conclusion:The constructed element framework and template of broad informed consent form is highly scientific and applicable,providing references for clinical research.
7.Qingda Granule Attenuates Hypertension-Induced Cardiac Damage via Regulating Renin-Angiotensin System Pathway.
Lin-Zi LONG ; Ling TAN ; Feng-Qin XU ; Wen-Wen YANG ; Hong-Zheng LI ; Jian-Gang LIU ; Ke WANG ; Zhi-Ru ZHAO ; Yue-Qi WANG ; Chao-Ju WANG ; Yi-Chao WEN ; Ming-Yan HUANG ; Hua QU ; Chang-Geng FU ; Ke-Ji CHEN
Chinese journal of integrative medicine 2025;31(5):402-411
OBJECTIVE:
To assess the efficacy of Qingda Granule (QDG) in ameliorating hypertension-induced cardiac damage and investigate the underlying mechanisms involved.
METHODS:
Twenty spontaneously hypertensive rats (SHRs) were used to develope a hypertension-induced cardiac damage model. Another 10 Wistar Kyoto (WKY) rats were used as normotension group. Rats were administrated intragastrically QDG [0.9 g/(kg•d)] or an equivalent volume of pure water for 8 weeks. Blood pressure, histopathological changes, cardiac function, levels of oxidative stress and inflammatory response markers were measured. Furthermore, to gain insights into the potential mechanisms underlying the protective effects of QDG against hypertension-induced cardiac injury, a network pharmacology study was conducted. Predicted results were validated by Western blot, radioimmunoassay immunohistochemistry and quantitative polymerase chain reaction, respectively.
RESULTS:
The administration of QDG resulted in a significant decrease in blood pressure levels in SHRs (P<0.01). Histological examinations, including hematoxylin-eosin staining and Masson trichrome staining revealed that QDG effectively attenuated hypertension-induced cardiac damage. Furthermore, echocardiography demonstrated that QDG improved hypertension-associated cardiac dysfunction. Enzyme-linked immunosorbent assay and colorimetric method indicated that QDG significantly reduced oxidative stress and inflammatory response levels in both myocardial tissue and serum (P<0.01).
CONCLUSIONS
Both network pharmacology and experimental investigations confirmed that QDG exerted its beneficial effects in decreasing hypertension-induced cardiac damage by regulating the angiotensin converting enzyme (ACE)/angiotensin II (Ang II)/Ang II receptor type 1 axis and ACE/Ang II/Ang II receptor type 2 axis.
Animals
;
Drugs, Chinese Herbal/therapeutic use*
;
Hypertension/pathology*
;
Renin-Angiotensin System/drug effects*
;
Rats, Inbred SHR
;
Oxidative Stress/drug effects*
;
Male
;
Rats, Inbred WKY
;
Blood Pressure/drug effects*
;
Myocardium/pathology*
;
Rats
;
Inflammation/pathology*
8.The value of total volume response and total mass response in the therapeutic evaluation of lung metastasis of hepatocarcinoma
Jun-cheng WAN ; Cai-hong YU ; Chang-yu LI ; Yong-jie ZHOU ; Wei ZHANG ; Jian-hua WANG ; Zhi-ping YAN ; Guo-wei YANG ; Zhuo-yang FAN ; Xu-dong QU
Fudan University Journal of Medical Sciences 2025;52(2):201-208,231
Objective To analyze the correlation between lesion volume,lesion mass,and maximum lesion diameter in the assessment of advanced hepatocarcinoma with lung metastasis,and to evaluate the application value of total volume response and total mass response of lung metastatic lesions in efficacy assessment.Methods A retrospective analysis was conducted on the CT imaging data of 20 patients clinically confirmed with hepatocarcinoma and lung metastases,followed by subsequent follow-up to monitor their survival outcomes.Volume measurement software was used to measure the volume of lesions before and after treatment.We recored lesion diameter,volume measurements and CT values,calculated the mass of the lesions.The correlation between lesion volume,mass and diameter was analyzed,as well as the correlation between the change rates of volume,mass and lesion diameter.Additionally,the total volume and total mass of all lesions were calculated.The correlation between the change rates of total volume/total mass and the change rate of pulmonary lesion diameter under the RECIST 1.1 criteria,as well as the correlation with changes in patients'tumor markers,were analyzed.Furthermore,the overall volume response and overall mass response of lesions were evaluated based on changes in total volume and total mass,and their consistencies with the RECIST 1.1 criteria for efficacy evaluation were analyzed.Finally,univariate Cox regression analysis was performed to explore the association between these variables and patient survival outcomes.Results There was strong correlation between lesion volume,mass and tumor diameter(r=0.771,0.775),between the rate of change in mass and the rate of change in lesion diameter(r=0.846),and between the rates of change in total volume/total mass and the rate of change in pulmonary lesion diameter under the RECIST 1.1 criteria(r=0.800,0.896).The correlation between the rates of change in total volume/total mass and patients'tumor markers was not statistically significant.There was moderate correlation between the rate of change in volume and the rate of change in lesion diameter(r=0.692).The evaluation results of total volume response and total mass response for pulmonary lesions in advanced hepatocarcinoma with lung metastasis were generally consistent with the RECIST 1.1 criteria(Kappa=0.486,0.426).Univariate Cox regression analysis revealed that total lesion volume(P=0.047)and total lesion mass(P=0.049)were independent prognostic factors for survival outcomes.Conclusion Lesion volume,mass,and diameter,as well as their respective change rates,were found to be interrelated.Furthermore,total lesion volume and total lesion mass were identified as independent prognostic factors for survival outcomes.The total volume response and total mass response are promising evaluation methods in evaluating the efficacy of lung metastasis of hepatocarcinoma,which are different from the RECIST 1.1 evaluation criteria.
9.Risk analysis for coil adverse events based on FDA MAUDE database
Jian-wei YANG ; Lin HUANG ; Yu-juan ZHAO ; Yi XUAN ; Jian-jun CAO ; Chang-qing LIU ; Hui-fang NIU ; Xia LI
Chinese Medical Equipment Journal 2025;46(6):83-87
The coil adverse events in the U.S.Food and Drug Administration Manufacturer and User Facility Device Experience(MAUDE)database from January 2021 to June 2024 were analyzed retrospectively.The risks of coils during the clinical application and their causes were explored with hospital survey and expert demonstration in Shandong Province.Some improving measures were put forward for the safe use of coils,including implementing the main responsibility of the registrant,enhancing the professional skills of the using institutions and strengthening the supervision of the supervisory authorities.[Chinese Medical Equipment Journal,2025,46(6):83-87]
10.Estimation of Tangential Ground Reaction Force by Data-Driven Modeling
Yang LÜ ; Chang LU ; Xiaoxu ZHANG ; Wenming CHEN ; Jian XU
Journal of Medical Biomechanics 2025;40(1):148-155
Objective To develop a data-driven model for estimating tangential ground reaction force(GRFt)from lower limb kinematic data and select the most suitable input based on a balance between input quantity and estimation accuracy,with the aim of measuring GRFt in outdoor gait experiments.Methods Gait data from ten subjects walking at five different inclines(-10°,-5°,0°,5°,10°)were used to train two data-driven models,namely a backpropagation neural network(BPNN)-based model and a polynomial sparse identification(PSI)-based model.The performance of these models was evaluated using eight kinematic data combinations and the normal ground reaction force(GRFn)as inputs to determine the optimal model and input combination.Results Under the same input dimensionality,the combination of hip-knee joint angles proved more accurate in estimating GRF,than the knee-ankle joint angle combination.Specifically,the BPNN and PSI models based on the former combination predicted GRF,with errors of 1.61%BW(body weight)and 1.84%BW,respectively,while the latter combination resulted in errors of 2.82%BW and 3.15%BW.When GRFn and all joint angles were used as inputs,the model's prediction error was only 1.46%BW.Conclusions The combination of GRFn and hip-knee joint angles achieves an optimal balance between computational complexity and estimation accuracy.This study supports the accurate estimation of GRF,in outdoor gait testing.

Result Analysis
Print
Save
E-mail