1.Proarrhythmic Risk Assessment of Sildenafil under High-Dose Misuse Conditions Using the Comprehensive In Vitro Proarrhythmia Assay (CiPA)
Hanbi KIM ; Tae Woong NA ; Inkyo JUNG ; Minji KANG ; Sujeong PARK ; Chan Hyeok KWON ; Kikyung JUNG
Biomolecules & Therapeutics 2026;34(3):578-588
The comprehensive in vitro proarrhythmia assay (CiPA) initiative, led by the U.S. Food and Drug Administration (FDA), provides a framework for predicting drug-induced arrhythmia risk. To support domestic CiPA implementation, we evaluated the proarrhythmic risk of sildenafil, a phosphodiesterase type 5 (PDE5) inhibitor. Sildenafil has been misused recreationally, with reports of highdose non-medical intake. To simulate misuse, in vitro assays were conducted using concentrations up to 100× the maximum therapeutic plasma concentration (Cmax). The assessment followed the three core components of the CiPA paradigm. Patch clamp assays were conducted in Human Embryonic Kidney 293 (HEK293) and Chinese hamster ovary (CHO) cells transiently expressing Nav1.5, Cav1.2, and hERG ion channels. In silico modeling was performed using the CiPAORdv1.0 model based on IC₅₀ and Hill coefficient values. Functional evaluation included multi-electrode array (MEA) recordings in human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs), and in vivo electrocardiography (ECG) analysis in rats was performed to observe QT interval prolongation. Sildenafil significantly inhibited hERG currents by 40.5% at 100× Cmax. In silico modeling predicted a low Torsades de Pointes (TdP) risk based on qNet biomarkers. In contrast, MEA recordings showed a concentration-dependent prolongation of corrected field potential duration (FPDc), with a significant 13.3% increase at 100× Cmax. The TdP risk estimated from MEA modeling was 64%. In vivo ECG analysis revealed significant QT prolongation at 50× Cmax. Despite low in silico TdP predictions, functional assays suggest that high concentrations of sildenafil as in misuse may pose a clinically relevant risk of QT prolongation and arrhythmia.
2.ERRATUM: Imaging follow-up strategy after endovascular treatment of intracranial aneurysms: A literature review and guideline recommendations
Yong-Hwan CHO ; Jaehyung CHOI ; Chae-Wook HUH ; Chang Hyeun KIM ; Chul Hoon CHANG ; Soon Chan KWON ; Young Woo KIM ; Seung Hun SHEEN ; Sukh Que PARK ; Jun Kyeung KO ; Sung-kon HA ; Hae Woong JEONG ; Hyen Seung KANG ;
Journal of Cerebrovascular and Endovascular Neurosurgery 2025;27(1):80-80
3.Validation of Devices for the Five Times Sit To Stand Test:Comparing Plantar Pressure and Head Motion Analysis with Manual Measurement
Sanghyun JEE ; Chan Woong JANG ; Kyoungmin PARK ; Sanghoon SHIN ; Min-Chul PAEK ; Jung Hyun PARK
Yonsei Medical Journal 2025;66(1):51-57
Purpose:
This study aims to evaluate a new method for the five times sit to stand test (FTSST), crucial for addressing frailty in an aging population. It utilizes a smart insole for plantar pressure analysis and a marker-less motion capture device for head height analysis.
Materials and Methods:
Thirty-five participants aged 50 years or older underwent FTSST assessment using three methods: manual measurement with a stopwatch (FTSST-M), plantar pressure analysis with smart insoles (FTSST-P), and head height analysis with a marker-less motion capture device (FTSST-H). Simultaneous measurements using three methods were done. Correlation between results of these methods were analyzed using intraclass correlation coefficient (ICC) and κ coefficient. Comprehensive clinical examinations were conducted with ethical approval.
Results:
Participants’ mean scores for FTSST-M, FTSST-P, and FTSST-H were 2.43±1.20, 2.43±1.29, and 2.37±1.31, respectively. Correlations of the times and corresponding scores between FTSST-P and FTSST-M, as well as FTSST-H and FTSST-M, exceeded 0.9 (ICC and κ coefficients, p<0.001). Using an FTSST score of 3 or less to indicate vulnerability, the κ value for vulnerability classification between two measurements was 0.886 (p<0.001).
Conclusion
This study showed strong correlation between FTSST results using smart insoles and marker-less motion capture, compared to conventional methods. These findings highlight the potential of these technologies for precise FTSST measurements, offering convenience and cost-effectiveness. Simultaneous use of these devices enables diverse analyses, enhancing our understanding of frailty.
4.ERRATUM: Imaging follow-up strategy after endovascular treatment of intracranial aneurysms: A literature review and guideline recommendations
Yong-Hwan CHO ; Jaehyung CHOI ; Chae-Wook HUH ; Chang Hyeun KIM ; Chul Hoon CHANG ; Soon Chan KWON ; Young Woo KIM ; Seung Hun SHEEN ; Sukh Que PARK ; Jun Kyeung KO ; Sung-kon HA ; Hae Woong JEONG ; Hyen Seung KANG ;
Journal of Cerebrovascular and Endovascular Neurosurgery 2025;27(1):80-80
5.Validation of Devices for the Five Times Sit To Stand Test:Comparing Plantar Pressure and Head Motion Analysis with Manual Measurement
Sanghyun JEE ; Chan Woong JANG ; Kyoungmin PARK ; Sanghoon SHIN ; Min-Chul PAEK ; Jung Hyun PARK
Yonsei Medical Journal 2025;66(1):51-57
Purpose:
This study aims to evaluate a new method for the five times sit to stand test (FTSST), crucial for addressing frailty in an aging population. It utilizes a smart insole for plantar pressure analysis and a marker-less motion capture device for head height analysis.
Materials and Methods:
Thirty-five participants aged 50 years or older underwent FTSST assessment using three methods: manual measurement with a stopwatch (FTSST-M), plantar pressure analysis with smart insoles (FTSST-P), and head height analysis with a marker-less motion capture device (FTSST-H). Simultaneous measurements using three methods were done. Correlation between results of these methods were analyzed using intraclass correlation coefficient (ICC) and κ coefficient. Comprehensive clinical examinations were conducted with ethical approval.
Results:
Participants’ mean scores for FTSST-M, FTSST-P, and FTSST-H were 2.43±1.20, 2.43±1.29, and 2.37±1.31, respectively. Correlations of the times and corresponding scores between FTSST-P and FTSST-M, as well as FTSST-H and FTSST-M, exceeded 0.9 (ICC and κ coefficients, p<0.001). Using an FTSST score of 3 or less to indicate vulnerability, the κ value for vulnerability classification between two measurements was 0.886 (p<0.001).
Conclusion
This study showed strong correlation between FTSST results using smart insoles and marker-less motion capture, compared to conventional methods. These findings highlight the potential of these technologies for precise FTSST measurements, offering convenience and cost-effectiveness. Simultaneous use of these devices enables diverse analyses, enhancing our understanding of frailty.
6.Validation of Devices for the Five Times Sit To Stand Test:Comparing Plantar Pressure and Head Motion Analysis with Manual Measurement
Sanghyun JEE ; Chan Woong JANG ; Kyoungmin PARK ; Sanghoon SHIN ; Min-Chul PAEK ; Jung Hyun PARK
Yonsei Medical Journal 2025;66(1):51-57
Purpose:
This study aims to evaluate a new method for the five times sit to stand test (FTSST), crucial for addressing frailty in an aging population. It utilizes a smart insole for plantar pressure analysis and a marker-less motion capture device for head height analysis.
Materials and Methods:
Thirty-five participants aged 50 years or older underwent FTSST assessment using three methods: manual measurement with a stopwatch (FTSST-M), plantar pressure analysis with smart insoles (FTSST-P), and head height analysis with a marker-less motion capture device (FTSST-H). Simultaneous measurements using three methods were done. Correlation between results of these methods were analyzed using intraclass correlation coefficient (ICC) and κ coefficient. Comprehensive clinical examinations were conducted with ethical approval.
Results:
Participants’ mean scores for FTSST-M, FTSST-P, and FTSST-H were 2.43±1.20, 2.43±1.29, and 2.37±1.31, respectively. Correlations of the times and corresponding scores between FTSST-P and FTSST-M, as well as FTSST-H and FTSST-M, exceeded 0.9 (ICC and κ coefficients, p<0.001). Using an FTSST score of 3 or less to indicate vulnerability, the κ value for vulnerability classification between two measurements was 0.886 (p<0.001).
Conclusion
This study showed strong correlation between FTSST results using smart insoles and marker-less motion capture, compared to conventional methods. These findings highlight the potential of these technologies for precise FTSST measurements, offering convenience and cost-effectiveness. Simultaneous use of these devices enables diverse analyses, enhancing our understanding of frailty.
7.Validation of Devices for the Five Times Sit To Stand Test:Comparing Plantar Pressure and Head Motion Analysis with Manual Measurement
Sanghyun JEE ; Chan Woong JANG ; Kyoungmin PARK ; Sanghoon SHIN ; Min-Chul PAEK ; Jung Hyun PARK
Yonsei Medical Journal 2025;66(1):51-57
Purpose:
This study aims to evaluate a new method for the five times sit to stand test (FTSST), crucial for addressing frailty in an aging population. It utilizes a smart insole for plantar pressure analysis and a marker-less motion capture device for head height analysis.
Materials and Methods:
Thirty-five participants aged 50 years or older underwent FTSST assessment using three methods: manual measurement with a stopwatch (FTSST-M), plantar pressure analysis with smart insoles (FTSST-P), and head height analysis with a marker-less motion capture device (FTSST-H). Simultaneous measurements using three methods were done. Correlation between results of these methods were analyzed using intraclass correlation coefficient (ICC) and κ coefficient. Comprehensive clinical examinations were conducted with ethical approval.
Results:
Participants’ mean scores for FTSST-M, FTSST-P, and FTSST-H were 2.43±1.20, 2.43±1.29, and 2.37±1.31, respectively. Correlations of the times and corresponding scores between FTSST-P and FTSST-M, as well as FTSST-H and FTSST-M, exceeded 0.9 (ICC and κ coefficients, p<0.001). Using an FTSST score of 3 or less to indicate vulnerability, the κ value for vulnerability classification between two measurements was 0.886 (p<0.001).
Conclusion
This study showed strong correlation between FTSST results using smart insoles and marker-less motion capture, compared to conventional methods. These findings highlight the potential of these technologies for precise FTSST measurements, offering convenience and cost-effectiveness. Simultaneous use of these devices enables diverse analyses, enhancing our understanding of frailty.
8.ERRATUM: Imaging follow-up strategy after endovascular treatment of intracranial aneurysms: A literature review and guideline recommendations
Yong-Hwan CHO ; Jaehyung CHOI ; Chae-Wook HUH ; Chang Hyeun KIM ; Chul Hoon CHANG ; Soon Chan KWON ; Young Woo KIM ; Seung Hun SHEEN ; Sukh Que PARK ; Jun Kyeung KO ; Sung-kon HA ; Hae Woong JEONG ; Hyen Seung KANG ;
Journal of Cerebrovascular and Endovascular Neurosurgery 2025;27(1):80-80
9.Validation of Devices for the Five Times Sit To Stand Test:Comparing Plantar Pressure and Head Motion Analysis with Manual Measurement
Sanghyun JEE ; Chan Woong JANG ; Kyoungmin PARK ; Sanghoon SHIN ; Min-Chul PAEK ; Jung Hyun PARK
Yonsei Medical Journal 2025;66(1):51-57
Purpose:
This study aims to evaluate a new method for the five times sit to stand test (FTSST), crucial for addressing frailty in an aging population. It utilizes a smart insole for plantar pressure analysis and a marker-less motion capture device for head height analysis.
Materials and Methods:
Thirty-five participants aged 50 years or older underwent FTSST assessment using three methods: manual measurement with a stopwatch (FTSST-M), plantar pressure analysis with smart insoles (FTSST-P), and head height analysis with a marker-less motion capture device (FTSST-H). Simultaneous measurements using three methods were done. Correlation between results of these methods were analyzed using intraclass correlation coefficient (ICC) and κ coefficient. Comprehensive clinical examinations were conducted with ethical approval.
Results:
Participants’ mean scores for FTSST-M, FTSST-P, and FTSST-H were 2.43±1.20, 2.43±1.29, and 2.37±1.31, respectively. Correlations of the times and corresponding scores between FTSST-P and FTSST-M, as well as FTSST-H and FTSST-M, exceeded 0.9 (ICC and κ coefficients, p<0.001). Using an FTSST score of 3 or less to indicate vulnerability, the κ value for vulnerability classification between two measurements was 0.886 (p<0.001).
Conclusion
This study showed strong correlation between FTSST results using smart insoles and marker-less motion capture, compared to conventional methods. These findings highlight the potential of these technologies for precise FTSST measurements, offering convenience and cost-effectiveness. Simultaneous use of these devices enables diverse analyses, enhancing our understanding of frailty.
10.The first Korean carbon-ion radiation therapy facility: current status of the Heavy-ion Therapy Center at the Yonsei Cancer Center
Min Cheol HAN ; Seo Hee CHOI ; Chae-Seon HONG ; Yong Bae KIM ; Woong Sub KOOM ; Jin Sung KIM ; Jaeho CHO ; Chan Woo WEE ; Changhwan KIM ; Jong Won PARK ; Soorim HAN ; Heejeong LEE ; Hong In YOON ; Ik Jae LEE ; Ki Chang KEUM
Radiation Oncology Journal 2024;42(4):295-307
Purpose:
This report offers a detailed examination of the inception and current state of the Heavy-ion Therapy Center (HITC) at the Yonsei Cancer Center (YCC), setting it apart as the world’s first center equipped with a fixed beam and two superconducting gantries for carbon-ion radiation therapy (CIRT).
Materials and Methods:
Preparations for CIRT at YCC began in 2013; accordingly, this center has completed a decade of meticulous planning and culminating since the operational commencement of the HITC in April 2023.
Results:
This report elaborates on the clinical preparation for adopting CIRT in Korea. It includes an extensive description of HITC’s facility layout at YCC, which comprises the accelerator and treatment rooms. Furthermore, this report delineates the clinical workflow, criteria for CIRT application, and the rigorous quality assurance processes implemented at YCC. It highlights YCC’s sophisticated radiation therapy infrastructure, collaborative initiatives, and the efficacious treatment of >200 prostate cancer cases utilizing CIRT.
Conclusion
This manuscript concludes by discussing the prospective influence of CIRT on the medical domain within Korea, spotlighting YCC’s pioneering contribution and forecasting the widespread integration of this groundbreaking technology.

Result Analysis
Print
Save
E-mail