1.Prospective clinical comparative evaluation of implant-supported zirconia-lithium disilicate bilayered ceramic and metalceramic posterior prostheses: a 3-year follow-up
Hye-Seon LEE ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
The Journal of Advanced Prosthodontics 2025;17(2):59-69
PURPOSE:
The aim of this study was to evaluate the clinical performance and survival rate of implant-supported zirconia-lithium disilicate (Zr-LiSi) bilayered ceramic prostheses over 3 years.
MATERIALS AND METHODS:
This study included 71 patients, including 34 with implant-supported metal-ceramic prostheses (control group) and 37 with implant-supported Zr-LiSi bilayered ceramic prostheses (test group). The implant survival rate and incidence of prosthetic and biological complications (veneer fractures, dislodgement of screw-access hole filling material, screw loosening, peri-implant mucositis and peri-implantitis, and marginal bone loss) were investigated. The survival rate was analyzed using Kaplan-Meier survival curves, and the identity between two groups was confirmed by the log-rank test.
RESULTS:
Both groups showed a 100% survival rate, whereas the prosthetic survival rates were 77% and 73% for the metal-ceramic and Zr-LiSi groups, respectively. Biological complications did not appear in the metal-ceramic group, and 16.2% of peri-implant mucositis occurred in the Zr-LiSi group, which was significant (P < .05). Prosthetic complications occurred in 5.8% of the metal-ceramic group with veneer fractures and did not occur in the Zr-LiSi bilayered ceramic group.
CONCLUSION
This study revealed that posterior Zr-LiSi bilayered ceramic implant prostheses showed high survival rates and similar survival rates to metal-ceramic implant prostheses; however, additional consideration should be given to avoid overcontouring. Zr-LiSi bilayered ceramic implant prostheses may be an option for posterior implant-supported prosthetic treatment.
2.Implant–supported fixed prosthesis for orthognathic surgery in ectodermal dysplasia: a case report
Yeon-Ah SHIN ; Ji-Eun MOON ; Se-Ha KANG ; Chan-Ik PARK ; Yoon-Joo BAE ; Min-Seok OH ; Woo-Jin JEON ; Na-Ra KANG ; Min-Jung BAEK
The Journal of Korean Academy of Prosthodontics 2025;63(1):20-30
Patients with ectodermal dysplasia often have atrophied alveolar bone and an inadequate maxillomandibular relationship owing to congenital edentulism.Accurate implant placement that can overcomes anatomical limitations and orthognathic surgery to improve the maxillomandibular relationship is necessary for creating implant-supported prosthesis for these patients. Implant placement and provisional prosthesis fabrication before orthognathic surgery can provide critical fixed reference points and ensure accuracy during orthognathic surgery.In our patient, a digital system was used to design a surgical guide that considered the predictable position of the definitive prosthesis, allowing the placement of implants to overcome anatomical limitations and the creation of fixed reference points via the delivery of a provisional prosthesis for effective orthognathic surgery. The lack of compensation during orthognathic surgery was considered in the definitive prosthesis. As a result, a prosthesis with a minimal anterior cantilever was fabricated. This study aimed to determine the appropriate sequence of multidisciplinary collaborations that would, result in the best functional and aesthetic outcomes.
3.Prospective clinical comparative evaluation of implant-supported zirconia-lithium disilicate bilayered ceramic and metalceramic posterior prostheses: a 3-year follow-up
Hye-Seon LEE ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
The Journal of Advanced Prosthodontics 2025;17(2):59-69
PURPOSE:
The aim of this study was to evaluate the clinical performance and survival rate of implant-supported zirconia-lithium disilicate (Zr-LiSi) bilayered ceramic prostheses over 3 years.
MATERIALS AND METHODS:
This study included 71 patients, including 34 with implant-supported metal-ceramic prostheses (control group) and 37 with implant-supported Zr-LiSi bilayered ceramic prostheses (test group). The implant survival rate and incidence of prosthetic and biological complications (veneer fractures, dislodgement of screw-access hole filling material, screw loosening, peri-implant mucositis and peri-implantitis, and marginal bone loss) were investigated. The survival rate was analyzed using Kaplan-Meier survival curves, and the identity between two groups was confirmed by the log-rank test.
RESULTS:
Both groups showed a 100% survival rate, whereas the prosthetic survival rates were 77% and 73% for the metal-ceramic and Zr-LiSi groups, respectively. Biological complications did not appear in the metal-ceramic group, and 16.2% of peri-implant mucositis occurred in the Zr-LiSi group, which was significant (P < .05). Prosthetic complications occurred in 5.8% of the metal-ceramic group with veneer fractures and did not occur in the Zr-LiSi bilayered ceramic group.
CONCLUSION
This study revealed that posterior Zr-LiSi bilayered ceramic implant prostheses showed high survival rates and similar survival rates to metal-ceramic implant prostheses; however, additional consideration should be given to avoid overcontouring. Zr-LiSi bilayered ceramic implant prostheses may be an option for posterior implant-supported prosthetic treatment.
4.Implant–supported fixed prosthesis for orthognathic surgery in ectodermal dysplasia: a case report
Yeon-Ah SHIN ; Ji-Eun MOON ; Se-Ha KANG ; Chan-Ik PARK ; Yoon-Joo BAE ; Min-Seok OH ; Woo-Jin JEON ; Na-Ra KANG ; Min-Jung BAEK
The Journal of Korean Academy of Prosthodontics 2025;63(1):20-30
Patients with ectodermal dysplasia often have atrophied alveolar bone and an inadequate maxillomandibular relationship owing to congenital edentulism.Accurate implant placement that can overcomes anatomical limitations and orthognathic surgery to improve the maxillomandibular relationship is necessary for creating implant-supported prosthesis for these patients. Implant placement and provisional prosthesis fabrication before orthognathic surgery can provide critical fixed reference points and ensure accuracy during orthognathic surgery.In our patient, a digital system was used to design a surgical guide that considered the predictable position of the definitive prosthesis, allowing the placement of implants to overcome anatomical limitations and the creation of fixed reference points via the delivery of a provisional prosthesis for effective orthognathic surgery. The lack of compensation during orthognathic surgery was considered in the definitive prosthesis. As a result, a prosthesis with a minimal anterior cantilever was fabricated. This study aimed to determine the appropriate sequence of multidisciplinary collaborations that would, result in the best functional and aesthetic outcomes.
5.Effect of Occlusal and Margin Design on the Fracture Load of Zirconia-Lithium Disilicate Bi-layered Posterior Crowns: An in Vitro Study
Sung-Hoon KIM ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
Journal of Korean Dental Science 2025;18(1):1-11
Purpose:
The opacity of zirconia sometimes requires a veneering material; thus lithium disilicate, a veneer material with excellent strength, can be used. This study investigated the fracture resistance of zirconia–lithium disilicate (Zr-LS2) bi-layered crowns according to the design of the substructure.
Materials and Methods:
Five groups of posterior Zr-LS2 restorations (Zirtooth and Amber LiSi-POZ) were fabricated with different zirconia substructure coverage (control group, groups half occlusal zirconia coverage; 1/2OZ, and three-quarter occlusal zirconia coverage; 3/4OZ) and margin designs (control group, groups collar margin; C-M, and collarless margin; Cl-M). All restorations were cemented with self-adhesive resin cement followed by 24-h water storage and thermocycling (10,000 cycles, 5°C and 55°C). The fracture load was measured, and failure mode analysis, fractography, and elemental analysis were performed. The one-way analysis of variance and Fisher’s exact test were performed for statistical analyses (α=.05).
Results:
A significant difference was found in the fracture load of Zr-LS2 restorations according to the zirconia coverage of the occlusal area and margin design (P<.05). Group 3/4OZ was significantly larger than the control group C and 1/2OZ (P<.05). The C-M group had greater fracture loads based on margin design than the control group C and Cl-M (P<.05).
Conclusion
The fracture resistance of posterior Zr-LS2 restorations increased with the zirconia coverage, occlusal thickness, and collar margin.
6.Consensus Statements on Tinnitus Assessment and Treatment Outcome Evaluation: A Delphi Study by the Korean Tinnitus Study Group
Oak-Sung CHOO ; Jung Mee PARK ; Euyhyun PARK ; Jiwon CHANG ; Min Young LEE ; Ho Yun LEE ; In Seok MOON ; Jae-Jun SONG ; Kyu-Yup LEE ; Jae-Jin SONG ; Eui-Cheol NAM ; Shi Nae PARK ; Hyun Joon SHIM ; Yoon Chan RAH ; Jae-Hyun SEO
Journal of Korean Medical Science 2025;40(7):e93-
Background:
Tinnitus is a multifactorial condition with no universally accepted assessment guidelines. The Korean Tinnitus Study Group previously established consensus statements on the definition, classification, and diagnostic tests for tinnitus. As a continuation of this effort, this study aims to establish expert consensus on tinnitus assessment and treatment outcome evaluation, specifically tailored to the Korean clinical context.
Methods:
A modified Delphi method involving 26 otology experts from across Korea was used. A two-round Delphi survey was conducted to evaluate statements related to tinnitus assessment before and after treatment. Statements were rated on a scale of 1 to 9 for the level of agreement. Consensus was defined as ≥ 70% agreement (score of 7–9) and ≤ 15% disagreement (score of 1–3). Statistical measures such as content validity ratio and Kendall’s coefficient of concordance (W) were calculated to assess agreement levels.
Results:
Of the 46 assessment-related statements, 17 (37%) reached consensus, though overall pre-treatment assessments showed weak agreement (Kendall’s W = 0.319). Key areas of agreement included the use of the visual analogue scale, numeric rating scale, and validated questionnaires for pre-treatment evaluation. Five statements, such as the use of computed tomography, magnetic resonance imaging, and angiography for diagnosing pulsatile tinnitus, achieved over 90% agreement. For treatment outcome measurements, 8 of 12 statements (67%) reached a consensus, with moderate agreement (Kendall’s W = 0.513). Validated questionnaires and psychoacoustic tests were recommended for evaluating treatment effects within 12 weeks. While standardized imaging for pulsatile tinnitus and additional clinical tests were strongly recommended, full consensus was not achieved across all imaging modalities.
Conclusion
This study provides actionable recommendations for tinnitus assessment and treatment evaluation, emphasizing the use of standardized tools and individualized approaches based on patient needs. These findings offer a practical framework to enhance consistency and effectiveness in tinnitus management within Korean clinical settings.
7.Expert Consensus on Developing Information and Communication Technology-Based Patient Education Guidelines for Rheumatic Diseases in the Korea
Junghee YOON ; Soo-Kyung CHO ; Se Rim CHOI ; Soo-Bin LEE ; Juhee CHO ; Chan Hong JEON ; Geun-Tae KIM ; Jisoo LEE ; Yoon-Kyoung SUNG
Journal of Korean Medical Science 2025;40(1):e67-
Background:
This study aimed to identify key priorities for the development of guidelines for information and communication technology (ICT)-based patient education tailored to the needs of patients with rheumatic diseases (RDs) in the Republic of Korea, based on expert consensus.
Methods:
A two-round modified Delphi study was conducted with 20 rheumatology, patient education, and digital health literacy experts. A total of 35 items covering 7 domains and 18 subdomains were evaluated. Each item was evaluated for its level of importance, and the responses were rated on a 4-point Likert scale. Consensus levels were defined as “high” (interquartile range [IQR] ≤ 1, agreement ≥ 80%, content validity ratio [CVR] ≥ 0.7), "Moderate" (IQR ≥ 1, agreement 50–79%, CVR 0.5–0.7), and "Low" (IQR > 1, agreement < 50%, CVR < 0.5).
Results:
Strong consensus was reached for key priorities for developing guidelines in areas such as health literacy, digital health literacy, medical terminology, user interface, and user experience design for mobile apps. Chatbot use and video (e.g., YouTube) also achieved high consensus, whereas AI-powered platforms such as ChatGPT showed moderate-to-high agreement. Telemedicine was excluded because of insufficient consensus.
Conclusion
The key priorities identified in this study provide a foundation for the development of ICT-based patient education guidelines for RDs in the Republic of Korea.Future efforts should focus on integrating digital tools into clinical practice to enhance patient engagement and improve clinical outcomes.
8.Consensus Statements on Tinnitus Treatment: A Delphi Study by the Korean Tinnitus Study Group
Junhui JEONG ; Ho Yun LEE ; Oak-Sung CHOO ; Hantai KIM ; Kyu-Yup LEE ; Jae-Jin SONG ; Jae-Hyun SEO ; Yoon Chan RAH ; Jae-Jun SONG ; Eui-Cheol NAM ; Shi Nae PARK ; In Seok MOON ; Hyun Joon SHIM
Journal of Korean Medical Science 2025;40(18):e75-
Background:
Tinnitus is a bothersome condition associated with various mechanisms of action. Although treatment methods vary according to these mechanisms, standardized guidelines would benefit both patients and clinicians. We conducted a Delphi study, a method that collects expert opinions through multiple rounds of questionnaires, to reach a consensus on tinnitus treatment with professional experts.
Methods:
A two-round modified Delphi survey was conducted to develop a clinical consensus on tinnitus treatment. The experts scored each statement on a scale of 1 (highest disagreement) to 9 (highest agreement) for their level of agreement on tinnitus treatment.Consensus was defined when 75% or more of the participants scored 7–9, and 15% or less scored 1–3. To ensure reliability of the responses, the content validity ratio and Kendall’s coefficient of concordance were evaluated.
Results:
Approximately 19 of 31 statements reached a consensus. All 3 statements reached a consensus regarding the candidates for treatment. Regarding treatment, 3 of 8 statements on medication, 2 of 2 statements on tinnitus retraining therapy/cognitive behavioral therapy, and 5 of 7 statements on auditory rehabilitation reached a positive consensus. Although all 6 statements regarding miscellaneous treatment reached a consensus, most were negatively agreed. For treatment with neuromodulation, none of the 5 statements reached a consensus.
Conclusion
The experts reached a high level of consensus on treatment candidates, tinnitus retraining therapy/cognitive behavioral therapy, and auditory rehabilitation in this modified Delphi study. The results of this study can provide beneficial and practical information for clinicians regarding the treatment of tinnitus.
9.Effect of Occlusal and Margin Design on the Fracture Load of Zirconia-Lithium Disilicate Bi-layered Posterior Crowns: An in Vitro Study
Sung-Hoon KIM ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
Journal of Korean Dental Science 2025;18(1):1-11
Purpose:
The opacity of zirconia sometimes requires a veneering material; thus lithium disilicate, a veneer material with excellent strength, can be used. This study investigated the fracture resistance of zirconia–lithium disilicate (Zr-LS2) bi-layered crowns according to the design of the substructure.
Materials and Methods:
Five groups of posterior Zr-LS2 restorations (Zirtooth and Amber LiSi-POZ) were fabricated with different zirconia substructure coverage (control group, groups half occlusal zirconia coverage; 1/2OZ, and three-quarter occlusal zirconia coverage; 3/4OZ) and margin designs (control group, groups collar margin; C-M, and collarless margin; Cl-M). All restorations were cemented with self-adhesive resin cement followed by 24-h water storage and thermocycling (10,000 cycles, 5°C and 55°C). The fracture load was measured, and failure mode analysis, fractography, and elemental analysis were performed. The one-way analysis of variance and Fisher’s exact test were performed for statistical analyses (α=.05).
Results:
A significant difference was found in the fracture load of Zr-LS2 restorations according to the zirconia coverage of the occlusal area and margin design (P<.05). Group 3/4OZ was significantly larger than the control group C and 1/2OZ (P<.05). The C-M group had greater fracture loads based on margin design than the control group C and Cl-M (P<.05).
Conclusion
The fracture resistance of posterior Zr-LS2 restorations increased with the zirconia coverage, occlusal thickness, and collar margin.
10.Consensus Statements on Tinnitus Assessment and Treatment Outcome Evaluation: A Delphi Study by the Korean Tinnitus Study Group
Oak-Sung CHOO ; Jung Mee PARK ; Euyhyun PARK ; Jiwon CHANG ; Min Young LEE ; Ho Yun LEE ; In Seok MOON ; Jae-Jun SONG ; Kyu-Yup LEE ; Jae-Jin SONG ; Eui-Cheol NAM ; Shi Nae PARK ; Hyun Joon SHIM ; Yoon Chan RAH ; Jae-Hyun SEO
Journal of Korean Medical Science 2025;40(7):e93-
Background:
Tinnitus is a multifactorial condition with no universally accepted assessment guidelines. The Korean Tinnitus Study Group previously established consensus statements on the definition, classification, and diagnostic tests for tinnitus. As a continuation of this effort, this study aims to establish expert consensus on tinnitus assessment and treatment outcome evaluation, specifically tailored to the Korean clinical context.
Methods:
A modified Delphi method involving 26 otology experts from across Korea was used. A two-round Delphi survey was conducted to evaluate statements related to tinnitus assessment before and after treatment. Statements were rated on a scale of 1 to 9 for the level of agreement. Consensus was defined as ≥ 70% agreement (score of 7–9) and ≤ 15% disagreement (score of 1–3). Statistical measures such as content validity ratio and Kendall’s coefficient of concordance (W) were calculated to assess agreement levels.
Results:
Of the 46 assessment-related statements, 17 (37%) reached consensus, though overall pre-treatment assessments showed weak agreement (Kendall’s W = 0.319). Key areas of agreement included the use of the visual analogue scale, numeric rating scale, and validated questionnaires for pre-treatment evaluation. Five statements, such as the use of computed tomography, magnetic resonance imaging, and angiography for diagnosing pulsatile tinnitus, achieved over 90% agreement. For treatment outcome measurements, 8 of 12 statements (67%) reached a consensus, with moderate agreement (Kendall’s W = 0.513). Validated questionnaires and psychoacoustic tests were recommended for evaluating treatment effects within 12 weeks. While standardized imaging for pulsatile tinnitus and additional clinical tests were strongly recommended, full consensus was not achieved across all imaging modalities.
Conclusion
This study provides actionable recommendations for tinnitus assessment and treatment evaluation, emphasizing the use of standardized tools and individualized approaches based on patient needs. These findings offer a practical framework to enhance consistency and effectiveness in tinnitus management within Korean clinical settings.

Result Analysis
Print
Save
E-mail