1.Antibacterial and biofilm-inhibiting activity of the crude Psidium guajava ethanolic leaf extracts against biofilm-forming Staphylococcus epidermidis (ATCC 12228).
Leeland Anthony L. DELA LUNA ; Ailyn M. YABES ; Cecilia Nelia C. MARAMBA-LAZARTE ; Irma R. MAKALINAO ; Lynn Crisanta R. PANGANIBAN ; Richard Henry P. TIONGCO II
Acta Medica Philippina 2025;59(17):86-97
BACKGROUND AND OBJECTIVE
The emergence of antimicrobial resistance (AMR) poses a significant global health threat, with developing countries such as the Philippines facing particularly severe impacts due to resource limitations. The most affected by AMR is Healthcare Acquired Infections (HAIs), including Catheter-Related Bloodstream Infections (CRBSIs). These are commonly associated with biofilm-forming bacteria like Staphylococcus epidermidis, which complicates treatment due to antibiotic resistance. The Philippine variety of Psidium guajava, a folklorically used medicinal plant, has shown potential antimicrobial properties that could offer a new avenue for combating resistant pathogens.
METHODSThis study evaluated the antibacterial and antibiofilm efficacy of crude Psidium guajava ethanolic leaf extracts (PGELE) against biofilm-forming S. epidermidis (ATCC 12228). PGELE was tested at five concentrations (ranging from 312.5 µg/mL to 10,000 µg/mL) using two-fold serial dilution to determine the Minimum Inhibitory Concentration (MIC) and Minimum Bactericidal Concentration (MBC) using agar dilution count method. For the Minimum Biofilm Inhibitory Concentration (MBIC) and Minimum Biofilm Eradication Concentration (MBEC), crude PGELE was tested at 0.25 x MIC, 0.5 x MIC, MIC, 2 x MIC and 4 x MIC.
RESULTSThe MIC for PGELE against S. epidermidis was determined to be 2500 µg/mL, and the MBC was 5000 µg/mL, indicating that PGELE exhibits bactericidal activity. In biofilm assays, PGELE demonstrated strong antibiofilm activity at concentrations as low as 625 µg/ mL, inhibiting biofilm formation by more than 50%. However, PGELE did not eradicate preformed biofilms, as indicated by the MBEC results at concentrations ranging from 625 µg/mL to 10,000 µg/mL.
CONCLUSIONPsidium guajava ethanolic leaf extracts exhibit antibacterial and antibiofilm activities against S. epidermidis, particularly in preventing biofilm formation. These findings suggest that PGELE could be developed as an effective natural antimicrobial agent for use in healthcare settings to prevent CRBSIs and other infections caused by biofilm-forming pathogens. Further research and development are warranted to explore the potential of PGELE for antimicrobial drug development.
Plants ; Bacteria ; Staphylococcus Epidermidis ; Catheter-related Infections ; Psidium Guajava ; Psidium
2.Bacterial biofilm formation of peritoneal dialysis catheter in patients with peritonitis-associated catheter removal.
Aichun LIU ; Huiping ZHAO ; Bei WU ; Shuying ZHENG ; Li ZUO ; Mei WANG
Journal of Peking University(Health Sciences) 2025;57(1):161-165
OBJECTIVE:
Peritoneal dialysis(PD)-associated peritonitis is a common and major complication of PD and the most common cause of technical failure of PD. The presence of bacterial biofilm may be an important factor leading to refractory or recurrence of peritonitis. To investigate the formation and characteristics of bacterial biofilms on PD catheters after peritonitis-associated catheter removal.
METHODS:
The patients with maintenance PD who were regularly followed up in the Peking University People' s Hospital from June 2007 to January 2022 were retrospectively analyzed. The patients who withdrew from PD because of peritonitis and removed the PD catheter in our hospital and underwent the scanning electron microscope examination of the catheter were selected. The general information of the patients, the electron microscope results of the PD catheter and the bacterial culture results of the PD fluid were summarized.
RESULTS:
(1) A total of 18 patients were included, 11 were female (accounting for 61.1%). The average age of the patients was (59.1±11.5) years, and the average duration of dialysis was (80.1±47.4) months. Primary kidney diseases were predominantly chronic glomerulonephritis (55.6%), followed by diabetic nephropathy (27.8%), and others (16.6%). The reasons for catheters removal in 18 patients were refractory peritonitis in 11 cases, recurrent peritonitis in 5 cases, and fungal peritonitis in 2 cases. (2) 16 of the 18 patients (88.9%) had catheter bacterial biofilm, and the bacterial biofilm forms were all cocci. Some were arranged in grape-like shapes, and their diameters ranged from about 500 nm to 1 000 nm. The bacterial culture results of peritoneal dialysis fluid showed that the three most common pathogens were Escherichia coli, methicillin-sensitive Staphylococcus aureus (MSSA), and Staphylococcus epidermidis. (3) Among the 18 patients enrolled, 13 patients (72.2%) had peritonitis in the past. The causative bacteria of peritonitis in 9 patients were cocci, including coagulase-negative Staphylococci (Staphylococcus suis, Staphylococcus surface, Staphylococcus xylosus, Staphylococcus warneri), Staphylococcus aureus, Streptococcus (Streptococcus salivarius and Aerococus viridans).
CONCLUSION
Bacterial biofilm formation on the inner surface of PD catheter is common in peritonitis-associated catheter removal patients. Not all PD catheters removed due to peritonitis have bacterial biofilms. Bacterial biofilms and peritonitis pathogens may not be consistent.
Humans
;
Biofilms/growth & development*
;
Peritonitis/etiology*
;
Peritoneal Dialysis/instrumentation*
;
Middle Aged
;
Female
;
Male
;
Retrospective Studies
;
Catheters, Indwelling/microbiology*
;
Device Removal
;
Catheter-Related Infections/microbiology*
;
Aged
;
Adult
3.Practice guideline on the prevention and treatment of central line associated bloodstream infection in 2025.
CHINESE SOCIETY OF CRITICAL CARE MEDICINE
Chinese Critical Care Medicine 2025;37(3):193-220
Central line associated bloodstream infection (CLABSI) is the most severe complication of indwelling intravascular catheters and one of the most common causes of intensive care unit (ICU)- or hospital-acquired infections. Once CLABSI occurs, it significantly increases the risk of mortality, long of hospital stay, and healthcare economic burden. In recent years, multiple large-scale clinical studies on the diagnosis, treatment, and prevention of CLABSI have been completed, providing evidence-based medical support for related practices. Additionally, evolving global trends in antibiotic resistance epidemiology and the development of novel antimicrobial agents necessitate adjustments in clinical management strategies. Based on these developments, the Chinese Society of Critical Care Medicine has updated and revised the Guideline on the Prevention and Treatment of Intravascular Catheter-Related Infections (2007). This guideline was developed following the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) system for evidence quality assessment. Guided by clinical questions, the working group initiated the process by defining key clinical issues, conducting literature searches, screening studies, performing meta-analyses, and synthesizing evidence-based findings to draft preliminary recommendations. These recommendations underwent iterative revisions through expert panel reviews, remote and in-person meetings, and two rounds of voting by the Standing Committee of the Chinese Society of Critical Care Medicine before finalization. The guideline comprises 52 recommendations, focusing on adult patients with central venous catheters in ICU. Key areas addressed include: selection of catheter insertion sites and techniques, catheter type and design, catheter management, prevention, diagnosis, and treatment of CLABSI. The guideline aims to provide ICU healthcare professionals with best practices for central line management, ensuring standardized clinical protocols for adult CLABSI.
Humans
;
Catheter-Related Infections/therapy*
;
Catheterization, Central Venous/adverse effects*
;
Bacteremia/therapy*
;
Intensive Care Units
;
Cross Infection/prevention & control*
4.Radiologic placement of totally implantable venous access devices: Outcomes and complications from a large oncology cohort.
Sonam TASHI ; Alfred Bingchao TAN ; Jasmine Ming Er CHUA ; Gek Hsiang LIM ; Nanda VENKATANARASIMHA ; Sivanathan CHANDRAMOHAN
Annals of the Academy of Medicine, Singapore 2024;54(1):27-35
INTRODUCTION:
Totally implantable venous access devices (TIVADs) or ports are increasingly used in oncology settings to provide long-term, easy venous access. This study reports our experience and results with 1180 cases in Singapore.
METHOD:
Data from January 2019 to January 2022, obtained from a hospital-approved secure database application called the Research Electronic Data Capture registry, were reviewed and analysed retrospectively.
RESULTS:
A total of 1180 patients underwent TIVAD implantation with a 100% technical success rate. The mean age of the cohort was 61.9 years. The mean dwell duration was 342 days (standard deviation [SD] 223; range 3-1911). By 1 February 2022, 83% of patients were still using the TIVAD, 13.6 % underwent removal after completion of treatment, 2.1% were removed due to infection, 0.6% due to malfunction, 0.6% due to port extrusion and 0.1% at patient's request. The right internal jugular vein (IJV) was the most commonly accessed site (83.6%), followed by the left IJV (15.6%). The early post-procedure complications were pain (24.7%), bruising (9.2%), swelling (3.6%), bleeding (0.5%), fever (0.4%), itchiness (0.2%) and allergic dermatitis (0.1%). The delayed post-procedure complications were TIVAD site cellulitis (3.80%); discharge (1.10%); skin erosion with device extrusion (0.60%); malpositioned catheter (0.33%), which was successfully repositioned, catheter-related bloodstream infections (0.25%); migration of TIVAD leading to catheter dislodgement (0.25%); venous thrombosis (0.25%); fibrin sheath formation requiring stripping (0.10%) and TIVAD chamber inversion (0.10%).
CONCLUSION
TIVAD implantation via the jugular vein under radiological guidance provides a safe, reliable and convenient means of long-term venous access in oncology patients. By sharing our experience and acceptable outcomes from a large oncology cohort, we aim to increase the awareness and adoption of TIVAD usage in oncology patients, especially in Asia.
Humans
;
Middle Aged
;
Male
;
Female
;
Retrospective Studies
;
Singapore/epidemiology*
;
Aged
;
Catheterization, Central Venous/instrumentation*
;
Neoplasms/drug therapy*
;
Catheters, Indwelling/adverse effects*
;
Adult
;
Jugular Veins/diagnostic imaging*
;
Aged, 80 and over
;
Catheter-Related Infections/epidemiology*
;
Central Venous Catheters/adverse effects*
5.Prevention and control status of central line-associated bloodstream infection in intensive care unit in Shandong province: a cross-sectional survey analysis.
Yang SHEN ; Zijian TAI ; Xue BAI ; Xuan SONG ; Man CHEN ; Qianqian GUO ; Cheng HUAN ; Li CHEN ; Jicheng ZHANG
Chinese Critical Care Medicine 2024;36(12):1315-1320
OBJECTIVE:
To provide evidence for further reducing the incidence of central line-associated bloodstream infection (CLABSI) according to investigation of the prevention and control of CLABSI in intensive care unit (ICU) in Shandong Province.
METHODS:
The questionnaire was developed by experts from Shandong Critical Care Medical Quality Control Center, combining domestic and foreign guidelines, consensus and research. A convenient sampling method was used to recruit survey subjects online from October 11 to 31, 2023 in the province to investigate the management status of central venous catheter (CVC) in ICU units of secondary and above hospitals.
RESULTS:
A total of 201 valid data were collected, involving 186 hospitals in the province, with a total of 201 ICU units, mainly comprehensive ICU (91%). The beds in ICU units were mainly single rooms (89%) and triple rooms (79%), and the ratio of doctors to total beds was 0.54 : 1. The training on the knowledge and operation of intravascular catheter-associated bloodstream infection in each ICU unit was mainly irregular (49%), and 96% of the catheter operators were authorized by the hospital. In terms of CVC selection, 89% of ICU units used dual-chamber CVC, and 86% of ICU units used catheters without antibiotic coating. When selecting the placement site, for conventional CVC catheterization, 65% preferred subclavian vein. Femoral vein was preferred in 87% of ICU units undergoing continuous renal replacement therapy. 95% of ICU units had established standardized operation procedure (SOP) for CVC placement. 86% of ICU units were capable of ultrasound positioning or guided puncture at the time of catheterization. During catheterization, 88% of ICU units met the sterile dress code. Before and after catheterzation, 81% and 77% of ICU units standardized hand hygiene. Only 31% of ICU units were covered from head to toe by aseptic wipes. For the choice of skin disinfectant, the majority of ICU units (72%) only used iodophor. After tube placement, 54% of ICU units chose sterile transparent dressing and 25% chose sterile gauze dressing. 98% of ICU units were sutured to secure the catheter. Regarding catheter replacement and removal, 45% of ICU units could not be removed or replaced within 2 days in emergency situations where the principle of sterility was not guaranteed. When CLABSI was suspected, 55% of ICU units were able to obtain the catheter tip, transcatheter blood culture, and contralateral peripheral vein blood culture at the same time. For CVC replacement frequency, most ICU units (75%) would not be replaced regularly, and some ICU units would be replaced regularly, but the frequency of replacement was different. For CLABSI prevention and control, 82% of ICU units developed a verification form or supervision form. When analyzing the sources of CLABSI data, most of them were filled in by themselves (60%). As for the frequency of data analysis, 57% were once a month.
CONCLUSIONS
All ICU units in Shandong Province are standardized in terms of the authorization of operators, the formulation of SOP, the formulation and implementation of verification form and supervision form, ultrasound-guided puncture, and hand hygiene before and after catheterization. However, there are still deficiencies in the training on knowledge and operation of intravascular catheter-associated bloodstream infections, maximum aseptic coverage, catheter replacement and removal, and the reporting sources of CLABSI data, which need to be strengthened in the follow-up work. At present, the selection of CVC, the selection of catheterization site, the selection of skin disinfectant and the selection of dressings after catheterization still need further research.
Intensive Care Units
;
Humans
;
Surveys and Questionnaires
;
China/epidemiology*
;
Cross-Sectional Studies
;
Catheter-Related Infections/epidemiology*
;
Catheterization, Central Venous/methods*
;
Cross Infection/epidemiology*
;
Central Venous Catheters/adverse effects*
;
Infection Control/methods*
6.Risk factors for peripherally inserted central catheterization-associated bloodstream infection in neonates.
Yan-Ping XU ; Zhen-Ru SHANG ; Robert M DORAZIO ; Li-Ping SHI
Chinese Journal of Contemporary Pediatrics 2022;24(2):141-146
OBJECTIVES:
To study the features of catheter-related bloodstream infection (CRBSI) or central line-associated bloodstream infection (CLABSI) after peripherally inserted central catheterization (PICC) in neonates admitted to the neonatal intensive care unit (NICU) and the risk factors for CRBSI or CLABSI.
METHODS:
A retrospective analysis was performed on the medical data of the neonates who were treated and required PICC in the NICU of the Children's Hospital, Zhejiang University School of Medicine from June 1, 2018 to May 1, 2020. The catheterization-related data were collected, including placement time, insertion site, removal time, and antimicrobial lock of PICC. The multivariate logistic regression model was used to investigate the risk factors for CRBSI or CLABSI in the neonates.
RESULTS:
A total of 446 neonates were enrolled, with a mean gestational age of (30.8±4.0) weeks, a mean birth weight of (1 580±810) g, a median age of 9 days, and a median duration of PICC of 18 days. The incidence rates of CLABSI and CRBSI were 5.6 and 1.46 per 1 000 catheter days, respectively. Common pathogens for CLABSI caused by PICC included Staphylococcus epidermidis (n=19) and Klebsiella pneumoniae (n=11), and those for CRBSI caused by PICC included Klebsiella pneumoniae (n=6). The risk of CLABSI caused by PICC increased significantly with prolonged durations of PICC and antibiotic use, and the PICC-related infection probability at head and neck was significantly lower than that in the upper and low limbs (P<0.05), while the above conditions were more obvious in neonates with a birth weight of <1 500 g. The risk of CRBSI caused by PICC decreased with the increase in gestational age (P<0.05).
CONCLUSIONS
CRBSI and CLABSI remain serious issues in NICU nosocomial infection. The identification of the risk factors for CRBSI and CLABSI provides a basis for improving the quality of clinical care and management.
Catheter-Related Infections/etiology*
;
Catheterization, Central Venous/adverse effects*
;
Catheterization, Peripheral/adverse effects*
;
Central Venous Catheters/adverse effects*
;
Child
;
Humans
;
Infant
;
Infant, Newborn
;
Retrospective Studies
;
Risk Factors
;
Sepsis/etiology*
7.Relationship between Stress Hyperglycemia and Catheter-related Urinary Tract Infection in Stroke Patients.
Zhao Yun XIE ; Hua BAI ; Fei Fei DENG
Acta Academiae Medicinae Sinicae 2021;43(2):188-192
Objective To verify the relationship between catheter-related urinary tract infection(CAUTI)and stress hyperglycemia during catheter retention in stroke patients. Methods We used nosocomial infection monitoring system to track the status of CAUTI in stroke patients in a hospital.The study cohort was all the patients who received retention catheterization from January 2016 to March 2020.According to the nested case-control design,multivariate logistic regression analysis was performed to explore the relationship between stress hyperglycemia and CAUTI in stroke patients with indwelling catheter. Results A total of 322 cases of CAUTI and 644 cases of non-CAUTI were enrolled in this study.The length of stay in the case group was(20.68 ± 3.73)d,significantly longer than that[(13.00 ± 4.01)d]in the control group(t=29.473,P <0.001).Compared with non-stress hyperglycemia,stress hyperglycemia posed a higher risk of CAUTI in the stroke patients with indwelling catheter(OR=2.020,95% CI=1.447-2.821,P=0.000)and led to the higher incidence of CAUTI in one thousand days(P<0.001). Conclusion Stress hyperglycemia in the stroke patients with indwelling catheter can significantly increase the risk of CAUTI.
Catheter-Related Infections/epidemiology*
;
Cross Infection/epidemiology*
;
Humans
;
Hyperglycemia/complications*
;
Stroke/complications*
;
Urinary Catheterization
;
Urinary Tract Infections/epidemiology*
8.Integrated Chinese and Western Medicine in Treatment of Critical Coronavirus Disease (COVID-19) Patient with Endotracheal Intubation: A Case Report.
Shun-Yu YAO ; Chao-Qi LEI ; Xiang LIAO ; Ru-Xiu LIU ; Xing CHANG ; Zhi-Ming LIU
Chinese journal of integrative medicine 2021;27(4):300-303
Adult
;
Anti-Bacterial Agents/therapeutic use*
;
COVID-19/drug therapy*
;
Catheter-Related Infections/microbiology*
;
China
;
Drug Resistance, Multiple, Bacterial
;
Drugs, Chinese Herbal/therapeutic use*
;
Humans
;
Intubation, Intratracheal
;
Male
;
Pneumonia, Viral/drug therapy*
;
Prosthesis-Related Infections/microbiology*
;
SARS-CoV-2
10.Risk Analysis of Catheter-related Bloodstream Infection and Thrombosis in Patients with Blood Diseases Undergoing Peripheral Introvascular Central Catheter (PICC).
Bin FAN ; Fen HUANG ; Yu-Hong ZHANG ; Gan-Hong MEI
Journal of Experimental Hematology 2019;27(1):272-276
OBJECTIVE:
To evaluate the effects of peripheral introvascular central catheters (PICC) on the catheter-associated bloodstream infections (CRBSI) and the formations of catheter-related bloodstream infections.
METHODS:
Total of 483 patients with hematologic malignancies admitted in our hospital from January 2013 to December 2016 were enrolled in this study, and 612 PICC catheterization were conducted. The median time of catheterization was 101 d (48 ∼ 184 d) . The incidence rates of CRBSI and CRTC were observed, and the CRBSI and CRTC associated variables were also analyzed.
RESULTS:
There were 47 cases of CRBSI (7.7%), and the incidence was 0.59‰ PICC days, and there were 16 cases of CRTC (2.6%), with the incidence of 0.20‰ PICC days. Meanwhile, no other related serious complications found. The Cox regression analysis of CRBSI and CRTC-associated variables showed that the acute leukemia was significantly related with a higher incidence of CRBSI as compared with the other type of disease, however, which was not significantly related with the CRTC.
CONCLUSION
Compared with the traditional CVAD catheterization, the PICC is more safe and effective for the patients with malignant tumors, thus which may become a alternative method for CVAD.
Catheter-Related Infections
;
etiology
;
Catheterization, Central Venous
;
adverse effects
;
Hematologic Diseases
;
Humans
;
Incidence
;
Risk Factors
;
Thrombosis
;
etiology


Result Analysis
Print
Save
E-mail