BACKGROUND AND PURPOSE
Transcranial doppler ultrasonography is a useful tool in screening intracranial stenosis, but one of the major limitation of this procedure is the lack of a suitable acousric window. This study aims rn investigate the profile of patients with inadequate transtemporal window.
METHODOLOGYAll transcranial doppler studies done from June 2002 - May 2007 at a rertiary hospital were reviewed. They were then classified based on the following: 1) presence or absence oftranstemporal window; 2) sex; and 3) age (e"65 orRESULTS
233 out of the 1 ,028 patiems have poor acoustic window. 72% of chem were females and 67% of them were aged 65 and above.
CONCLUSIONPoor transtemporal window occurs in 23% of patients undergoing transcranial doppler and most of them are females 65 years old and above.
Human
;
Ultrasonography, Doppler, Transcranial
;
Acoustics
;
Temporal Bone
;
Constriction, Pathologic