1.The first intraoperative EEG monitoring during a common carotid artery endoaneurysmorrhaphy in a Philippine Tertiary Government Hospital: A case report
Athena Kate D. Antonio ; Maxine Lourraine T. Ty ; Katerina Tanya Perez-gosiengfiao
Acta Medica Philippina 2025;59(13):95-100
The surgical treatment of the rare extracranial carotid artery aneurysm can lead to significant thromboembolic events in 4.4% of cases. Intraoperative monitoring has helped detect hypoperfusion and probable ischemic events, but this is not widely available in resource-limited hospitals in the Philippines. This case highlights the use of a portable standard 21-channel EEG machine for intraoperative monitoring in a tertiary government hospital. In addition, it highlights a conception of a protocol for the intraoperative electroencephalogram monitoring of carotid endoaneurysmorrhaphy procedures in a resource-limited setting. During the aneurysmorrhaphy procedure, the authors collaborated with the surgeons and the anesthesiologists to provide feedback about EEG changes during the operation. After a pre-induction baseline was recorded, continuous EEG monitoring was performed until the patient emerged from anesthesia. Mild EEG changes, attributed to relative hypotension, were observed during the procedure. These episodes were responsive to BP augmentation. There were no EEG changes observed during carotid cross-clamping. Shunting was not recommended to the surgical team. No new neurologic deficits were documented postoperatively and on follow-up after six months. This paper illustrates how an intraoperative team was formed, and intraoperative EEG was utilized for a complex carotid endoaneurysmorrhaphy for a patient with ECAA in a tertiary government hospital in the Philippines.
Human ; Resource-limited Settings ; Carotid Arteries ; Philippines
2.Successful thrombolysis and mechanical thrombectomy in an early pregnant woman with protein S deficiency and arterial ischemic stroke: A case report
Ma. Ericka S. Del Mundo ; Diana-lynn Que ; Remy Margarette Berroya-Moreno
Philippine Journal of Neurology 2024;27(2):16-21
Protein S deficiency causing arterial ischemic stroke during pregnancy is uncommon. Delay or omission of treatment with perfusion therapies may worsen outcomes for both the mother and the fetus. In this paper, we report a case of an early pregnant woman with protein S deficiency and multiple history of chronic cerebrovascular disease who underwent successful thrombolysis and mechanical thrombectomy. The patient is a 35-year-old woman, eight weeks pregnant, with a history of protein S deficiency and chronic cerebrovascular disease, presenting with rightsided weakness and aphasia. Initial National Institutes of Health Stroke Scale was 10 with cranial magnetic resonance imaging findings of acute infarcts on the left caudate, lentiform nucleus, insula, and frontal lobe with a large vessel occlusion on the proximal M1 segment of the left middle cerebral artery. Intravenous thrombolysis and mechanical thrombectomy were performed with complete recanalization. The patient improved and delivered without any complications after 8 months. Protein S deficiency can contribute to arterial thrombosis including ischemic stroke. Arterial ischemic stroke and large vessel occlusion can cause significant disability if not treated appropriately. Reperfusion therapies in pregnant women show favorable outcomes and should be performed if the benefits outweigh the risks.
Human ; Female ; Adult: 25-44 Yrs Old ; Arteries ; Ischemic Stroke ; Thrombectomy ; Protein S ; Protein S Deficiency ; Pregnant Women
3.The intraoperative anatomic difference between the use of a standard cystoscope when compared to standard operating microscope as an innovative approach of performing a subinguinal varicocelectomy with intraoperative vascular doppler: Preliminary result of a novel technique
Janssen Dion T. Unas ; Marlon Martinez
Philippine Journal of Urology 2024;34(1):9-13
Objective:
The varicocoele exist in approximately 35-40% of primary male factor infertility while two to 10 percent of cases presents with pain.1 Most surgeons favor subinguinal microscopic varicocoelectomy because it offers superior improvement in semen parameters and reproductive outcome with the least complication rate. This study aimed to show an innovative surgical technique in the management of men with varicoceles.
Methods:
Subinguinal varicocelectomies were performed by a single surgeon on all patients starting with a standard cystoscope stabilized by a customized mechanical holding system attached to the operating bed. All the presumed vascular channels, vas deferens and lymphatics were isolated and marked with vascular loops and surgical ties. After all the presumed vessels were tagged, the standard operating microscope was brought to the operative field and full microsurgical dissection was carried out.
Results:
Ten varicocelectomies were performed on six men with a mean age of 30.5 years. 13 arteries, 84 veins, and 20 lymphatics were identified by the cystoscope while 18 arteries, 93 veins, and 29 lymphatics were identified by the standard operating microscope. Comparing the two modalities, 72%, 90%, and 69% of the arteries, veins, and lymphatics, respectively, were correctly identified by the cystoscope when compared to the latter.
Conclusion
Subinguinal varicocelectomy using a standard cystoscope could be offered as an alternative surgical approach in men with varicoceles as it can identify veins comparable with that of the standard operating microscope. In addition, a standard cystoscope can also identify, to some degree, lymphatics and arteries during surgical dissection. This innovative surgical technique can serve as a valuable option in the treatment of men with varicoceles.
Cystoscopes
;
Veins
;
Arteries
6.Peritoneal dialysis for refractory heart failure from a congenitally corrected transposition of the great arteries who has not undergone definitive surgery: A case report
Sheryll Anne R. Manalili ; Agnes D. Mejia ; Ronaldo H. Estacio
Acta Medica Philippina 2023;57(4):57-62
Heart failure (HF) is a major cause of significant morbidity, mortality, and hospitalization worldwide including the
Philippines. Congenitally corrected transposition of the great arteries (C-TGA) occurs when the right atrium enters the morphological left ventricle which gives rise to the pulmonary artery and the left atrium communicates with the right ventricle which gives rise to the aorta. Heart failure can occur in C-TGA especially if associated with other heart defects. Ideal management is anatomic correction via surgery to prevent or address heart failure. Peritoneal dialysis has been used as a therapeutic intervention for patients with refractory heart failure and kidney injury with or without kidney failure due to its gentler fluid removal compared to conventional ultrafiltration resulting in less myocardial stunning and neurohormonal activation. We present the case of a patient with heart failure who started on peritoneal dialysis (PD) as an adjunct therapy for fluid management after failing to satisfactorily achieve volume control with diuretics.
The patient is a 56-year-old man with C-TGA admitted for decompensated heart failure. He was initially treated
with intravenous diuretics on the first admission but was readmitted after 3 months for decompensation this time with borderline low blood pressure making diuresis difficult. The patient was given loop diuretics, tolvaptan, and angiotensin receptor neprilysin inhibitor (ARNI) but still with decreasing trends in urine output and inadequate symptom control. PD was initiated before discharge with subsequent improvement in heart failure symptoms. The patient was on regular follow-up for PD maintenance and titration of heart failure medication.
In this case report, we have shown how PD can be an effective adjunct to guideline-directed medical therapy in
patients with severely symptomatic heart failure who have an unstable hemodynamic status and for which volume management cannot be satisfactorily achieved with diuretics.
peritoneal dialysis
;
heart failure
;
congenital heart disease
;
congenitally corrected transposition of the great arteries
;
diuresis
;
ultrafiltration
7.Comparison of immediate changes of repolarization parameters after left bundle branch area pacing and traditional biventricular pacing in heart failure patients.
Yao LI ; Wenzhao LU ; Qingyun HU ; Chendi CHENG ; Jinxuan LIN ; Yu'an ZHOU ; Ruohan CHEN ; Yan DAI ; Keping CHEN ; Shu ZHANG
Chinese Medical Journal 2023;136(7):868-870
8.Effect of Xiaoxuming Decoction on synaptic plasticity following acute cerebral ischemia-reperfusion in rats.
Xue-Qin FU ; Rui LAN ; Yong ZHANG ; Man-Man WANG ; Xu-Huan ZOU ; Wei-Wei WANG
China Journal of Chinese Materia Medica 2023;48(14):3882-3889
This study aims to explore the effect of Xiaoxuming Decoction on synaptic plasticity in rats with acute cerebral ischemia-reperfusion. A rat model of cerebral ischemia-reperfusion injury was established by middle cerebral artery occlusion(MCAO). Rats were randomly assigned into a sham group, a MCAO group, and a Xiaoxuming Decoction(60 g·kg~(-1)·d~(-1)) group. The Longa score was rated to assess the neurological function of rats with cerebral ischemia for 1.5 h and reperfusion for 24 h. The 2,3,5-triphenyltetrazolium chloride(TTC) staining and hematoxylin-eosin(HE) staining were employed to observe the cerebral infarction and the pathological changes of brain tissue after cerebral ischemia, respectively. Transmission electron microscopy was employed to detect the structural changes of neurons and synapses in the ischemic penumbra, and immunofluorescence, Western blot to determine the expression of synaptophysin(SYN), neuronal nuclei(NEUN), and postsynaptic density 95(PSD95) in the ischemic penumbra. The experimental results showed that the modeling increased the Longa score and led to cerebral infarction after 24 h of ischemia-reperfusion. Compared with the model group, Xiaoxuming Decoction intervention significantly decreased the Longa score and reduced the formation of cerebral infarction area. The modeling led to the shrinking and vacuolar changes of nuclei in the brain tissue, disordered cell arrangement, and severe cortical ischemia-reperfusion injury, while the pathological damage in the Xiaoxuming Decoction group was mild. The modeling blurred the synaptic boundaries and broadened the synaptic gap, while such changes were recovered in the Xiaoxuming Decoction group. The modeling decreased the fluorescence intensity of NEUN and SYN, while the intensity in Xiaoxuming Decoction group was significantly higher than that in the model group. The expression of SYN and PSD95 in the ischemic penumbra was down-regulated in the model group, while such down-regulation can be alleviated by Xiaoxuming Decoction. In summary, Xiaoxuming Decoction may improve the synaptic plasticity of ischemic penumbra during acute cerebral ischemia-reperfusion by up-regulating the expression of SYN and PSD95.
Rats
;
Animals
;
Rats, Sprague-Dawley
;
Brain Ischemia/drug therapy*
;
Reperfusion Injury/metabolism*
;
Infarction, Middle Cerebral Artery
;
Neuronal Plasticity
;
Reperfusion
9.Animal experimental study on the effects of different levels of amputation on cardiovascular system.
Lei MIN ; Wentao JIANG ; Zhongyou LI ; Xiao LI ; Junjie DIAO ; Renjing LIU ; Tianxiang TAI ; Taoping BAI
Journal of Biomedical Engineering 2023;40(3):515-521
Vascular injury resulting from lower limb amputation leads to the redistribution of blood flow and changes in vascular terminal resistance, which can affect the cardiovascular system. However, there was no clear understanding of how different amputation levels affect the cardiovascular system in animal experiments. Therefore, this study established two animal models of above-knee amputation (AKA) and below-knee amputation (BKA) to explore the effects of different amputation levels on the cardiovascular system through blood and histopathological examinations. The results showed that amputation caused pathological changes in the cardiovascular system of animals, including endothelial injury, inflammation, and angiosclerosis. The degree of cardiovascular injury was higher in the AKA group than in the BKA group. This study sheds light on the internal mechanisms of amputation's impact on the cardiovascular system. Based on the amputation level of patients, the findings recommend more comprehensive and targeted monitoring after surgery and necessary interventions to prevent cardiovascular diseases.
Animals
;
Animal Experimentation
;
Cardiovascular System
;
Cardiovascular Diseases
;
Hypertension
;
Amputation, Surgical
10.Three-dimensional printed 316L stainless steel cardiovascular stent's electrolytic polishing and its mechanical properties.
Zhiang CHEN ; Jingtao MIAO ; Qilong WANG ; Suxia HUANG ; Jingjing CAO ; Hezong LI ; Liguo ZHAO ; Jiangyong YUAN
Journal of Biomedical Engineering 2023;40(3):552-558
The interventional therapy of vascular stent implantation is a popular treatment method for cardiovascular stenosis and blockage. However, traditional stent manufacturing methods such as laser cutting are complex and cannot easily manufacture complex structures such as bifurcated stents, while three-dimensional (3D) printing technology provides a new method for manufacturing stents with complex structure and personalized designs. In this paper, a cardiovascular stent was designed, and printed using selective laser melting technology and 316L stainless steel powder of 0-10 µm size. Electrolytic polishing was performed to improve the surface quality of the printed vascular stent, and the expansion behavior of the polished stent was assessed by balloon inflation. The results showed that the newly designed cardiovascular stent could be manufactured by 3D printing technology. Electrolytic polishing removed the attached powder and reduced the surface roughness Ra from 1.36 µm to 0.82 µm. The axial shortening rate of the polished bracket was 4.23% when the outside diameter was expanded from 2.42 mm to 3.63 mm under the pressure of the balloon, and the radial rebound rate was 2.48% after unloading. The radial force of polished stent was 8.32 N. The 3D printed vascular stent can remove the surface powder through electrolytic polishing to improve the surface quality, and show good dilatation performance and radial support performance, which provides a reference for the practical application of 3D printed vascular stent.
Humans
;
Stainless Steel
;
Powders
;
Cardiovascular System
;
Constriction, Pathologic


Result Analysis
Print
Save
E-mail