1.Genetic disease diagnosis and treatment in Shanghai: Survey and countermeasures for clinical genetics specialist training.
Xiaoju HUANG ; Lin HAN ; Li CAO ; Taosheng HUANG ; Duan MA ; Jian WANG ; Wenjuan QIU ; Fanyi ZENG ; Luming SUN ; Chenming XU ; Songchang CHEN ; Xinyu KUANG ; Hong TIAN
Chinese Journal of Medical Genetics 2026;43(4):241-247
OBJECTIVE:
To investigate the current status of clinical genetics specialization development and the diagnostic and therapeutic capabilities for hereditary diseases across medical institutions in Shanghai, and to assess the necessity and feasibility of establishing training bases for clinical genetics specialists.
METHODS:
By employing a cross-sectional survey design, the Clinical Genetics Committee of Shanghai Medical Association has conducted questionnaire surveys from March to April 2025 across 54 healthcare institutions in Shanghai (including 33 tertiary hospitals and 21 secondary hospitals). The survey involved administrative departments and medical personnel from 15 clinical specialties. The survey has covered current genetic disease diagnosis and treatment practices, relevant and specialised disease types, genetic department establishment, testing capabilities, personnel teams, and training requirements.
RESULTS:
The results revealed that 78.0% of clinical departments surveyed had treated patients with hereditary disorders. Shanghai possesses diagnostic and therapeutic expertise for over 95% of hereditary diseases listed in its rare disease catalogue, reflecting both the practical clinical demand for such conditions and the city's overall diagnostic and therapeutic strengths in this field. Nevertheless, significant disparities exist in the development of genetics departments across different tiers of healthcare institutions. Resources for genetic testing capabilities (including molecular, cellular, and biochemical testing) are also unevenly distributed across different tiers of hospitals. The survey further revealed that only 26.0% of departments believe that their current physician structure fully meets the diagnostic and treatment demands. Over 90% of departments consider standard training for clinical genetic specialists necessary, with 74.0% expressing willingness to participate in establishing training bases. Based on above findings and thorough deliberation, the Clinical Genetics Committee of the Shanghai Medical Association proposes advancing specialist training and discipline development through establishing a standard training system. The committee has drafted a three-year training protocol featuring a "joint training"-centered model, recommending a pilot-first, dynamically optimized strategy for steadily advancing training base development.
CONCLUSION
Shanghai faces substantial demand for genetic disease diagnosis and treatment, yet exhibits shortcomings in clinical genetics specialization development, resource allocation, and talent pipeline cultivation. To establish a standard training system holds significant practical importance and is underpinned by a broad demand.
Humans
;
China
;
Surveys and Questionnaires
;
Genetic Diseases, Inborn/genetics*
;
Cross-Sectional Studies
;
Genetics, Medical/education*
;
Genetic Testing
2.Mechanisms of sesamin on the prevention and treatment of fatty liv-er disease in hypertensive rats with dyslipidemia based on mRNA-seq
Yundong WANG ; Xuening LI ; Moxuan LI ; Wenjing CAO ; Hao RONG ; Chen YANG ; Xue-rui ZHU ; Xinyu XU ; Ye WANG ; Ya ZHANG ; Huanhuan JIN ; Zongyuan HONG ; Junxiu ZHANG
Chinese Journal of Clinical Pharmacology and Therapeutics 2025;30(7):876-888
AIM:To investigate the preventive and therapeutic effects of sesamin(SES)on fatty liver disease in rats with hypertension combined with dyslipidemia,and to explore the potential mecha-nisms based on mRNA-seq.METHODS:Spontane-ously hypertensive rats(SHRs)were fed a high-fat,high-cholesterol diet to establish a rat model of hy-pertension combined with dyslipidemia,and then treated with SES for 16 weeks continuously.The ex-periment was divided into four groups:WKY,SHR,Model,and Model+SES(160 mg·kg-1·d-1).Blood pressure was measured using the tail-cuff method.Body weight was monitored,and body mass index was calculated.Liver morphology was detected by ultrasound,and liver thickness was measured.Liver wet weight was weighed,and liver index was calcu-lated.Liver volume was detected by the water dis-placement method.Serum triglycerides(TG),total cholesterol(TC),low-density lipoprotein cholesterol(LDL-C),high-density lipoprotein cholesterol(HDL-C),alanine aminotransferase(ALT),aspartate amino-transferase(AST),and total bile acids(TBA)were de-tected by ELISA.Liver sequencing analysis was per-formed using mRNA-seq.Liver histomorphological changes were observed by HE staining.The degree of hepatic steatosis was observed by Oil Red O stain-ing,and the degree of hepatic fibrosis was observed by MASSON staining.The mRNA expression of Al-dh1a7,Nnmt,Irs2,Pltp,and Scd was detected by q-PCR.The protein expression of Scd,Nnmt,AMPK,p-AMPK,PPARα,and PPARγ was detected by Western blotting.RESULTS:After 16 weeks of continuous SES administration to rats with hypertension combined with dyslipidemia,blood pressure was significantly reduced(P<0.01),and body weight was decreased.Serum TG,TC,and LDL-C levels were decreased,while HDL-C levels were increased.Serum ALT and AST levels were decreased.Liver weight,organ in-dex,liver thickness,and liver volume were de-creased.The degree of hepatic steatosis and hepat-ic fibrosis was improved.A total of 545 differentially expressed mRNAs were identified in the livers of rats in each group,of which 278 were upregulated and 267 were downregulated.Among the 27 com-monly differentially expressed mRNAs,five mRNAs related to lipid metabolism were screened,namely Aldh1a7,Nnmt,Irs2,Pltp,and Scd.KEGG enrich-ment analysis showed that the enriched pathways were AMPK and PPAR.Further validation revealed that in the SES-treated group,the mRNA expression of Scd in the liver was decreased,while the mRNA expression of Nnmt was increased.The protein ex-pression of Scd was decreased,while the protein ex-pression of Nnmt,AMPK,p-AMPK,PPARα,and PPARγ was increased.CONCLUSION:SES has preven-tive and therapeutic effects on fatty liver disease in rats with hypertension combined with dyslipidemia,and its mechanism of action may be related to the reduction of Scd expression levels in the liver and the increase in the expression of Nnmt,AMPK,p-AMPK,PPARα,and PPARγ.
3.Three-dimensional finite element analysis of three-dimensional printed personalized orthodontic appliances for vertical movement of single teeth
Yilin CAO ; Xinyu WANG ; Yan ZHUANG ; Yaru WANG ; Zhixiu JIANG ; Danyu LIU ; Jiuxu MEN ; Yuansheng DING
Chinese Journal of Tissue Engineering Research 2025;29(16):3360-3368
BACKGROUND:Based on the principle of vertical tooth movement,a personalized orthodontic appliance is created through digital design combined with 3D printing,so that the personalized orthodontic appliance forms a support system with the individual incisors.With the help of the absolute support of the micro-implant,the single tooth is precisely controlled in a three-dimensional direction.OBJECTIVE:To design personalized orthodontic appliances with 11,12,21,and 22 intrusion and extrusion based on biomechanical principles,and analyze the safety of the personalized orthodontic appliances in terms of their movement effect on the teeth by means of the three-dimensional finite element method.METHODS:Three-dimensional finite element models of alveolar bone-periodontium-maxillary incisors-personalized cantilever micro-implant-connecting plates-personalized brackets in the maxillary anterior region(teeth numbers 11,12,21,and 22)were established using Mimics,Geomagic Wrap,SolidWorks,and Ansys Workbench software,respectively.Personalized orthodontic appliances with low pressure movement and extended movement were set up at each tooth position.The stress level of each component of the personalized orthodontic appliances was analyzed,and the tooth displacement and periodontal stress distribution were calculated under loading of 300 g tensile or thrust force.RESULTS AND CONCLUSION:(1)The maximum equivalent force on the personalized intrusion mobile orthodontic appliance was 162.90 MPa,and the maximum equivalent force on the personalized extrusion mobile orthodontic appliance was 239.57 MPa.The maximum equivalent stress on both devices was located in the vertical portion of the personalized bracket loading attachment.The equivalent stresses on each part of the personalized orthodontic appliance were all within the yield strength,and they had good safety.(2)The initial displacement of the teeth under the action of the personalized orthodontic appliances showed a tendency towards overall intrusion or extrusion,with the displacement in the vertical direction far exceeding that in the horizontal and sagittal directions.The equivalent stress peak appeared at the root tip or neck of the periodontal membrane,and the equivalent stress concentration area appeared in the periodontal membrane of the root apical region.(3)The results show that the personalized orthodontic appliance allows 11,12,21,and 22 to approximate either intrusion movement or extrusion movement,initially confirming the effectiveness of the personalized vertical movement orthodontic appliance.
4.Personalized GYROID condylar prosthesis:design and finite element analysis
Danyu LIU ; Tingting JIANG ; Zhixiu JIANG ; Yuchen JI ; Yilin CAO ; Lei WANG ; Yucheng SU ; Xinyu WANG
Chinese Journal of Tissue Engineering Research 2025;29(17):3548-3556
BACKGROUND:Currently,the mandibular joint prosthesis manufactured at home and abroad needs to rely on screws to fix the condylar part of the prosthesis during the replacement process,and the retention hole is reserved to facilitate the operation during the operation.However,due to the lack of personalized jaw design,the reattachment plate may not fit the jaw,resulting in screw loosening and dislocation.Therefore,personalized condylar prosthesis replacement is of great value in the repair of the temporomandibular joint.OBJECTIVE:To design a personalized condylar prosthesis with an internal GYROID for mandibular condylar repair and reconstruction.METHODS:The GYROID structure was selected in the Rhinoceros 7 software with the single cell size of 6 mm and the wall thickness of 0.2,0.3,0.4,0.5,0.6,0.7,0.8 mm.The mechanical properties of the GYROID structure were analyzed by finite element method.3D printing of GYROID structural test specimens with different wall thickness(0.2,0.3,0.4,0.5,0.6,0.7,and 0.8 mm)was performed to test the mechanical properties of the specimens through room temperature compression experiments.A wall thickness value conforming to the range of mandibular mechanical properties was selected through finite element analysis and room temperature compression test results.An adult male mandibular CT data were used for inverse modeling to design a condylar prosthesis with an internal GYROID.Finite element analysis was used to simulate the movement of the apical staggered position and the opposite-blade jaw position after condylar prosthesis replacement.RESULTS AND CONCLUSION:(1)The results of finite element analysis and room temperature compression experiment showed that the elastic modulus of the GYROID structure increased with the increase of wall thickness.The elastic modulus of the GYROID structure with wall thickness of 0.5-0.7 mm was within the range of the elastic modulus of the mandible(1.5-4.0 GPa).Therefore,the 6 mm monocellular GYROID structural model with a wall thickness of 0.6 mm was selected for the design of the condylar prosthesis.(2)The results of finite element analysis showed that the stress distribution of mandibular model was symmetrical.The stress distribution of the two types of occlusion was roughly the same,and the stress peak was not significantly different.The stress concentrated in the neck of the condylar prosthesis,and the stress on the replacement side was slightly larger than that on the healthy side.The maximum equivalent stress of the whole internal fixation model was 269.34 MPa,and the maximum equivalent stress of the screw was 20.14 MPa.The equivalent stress and equivalent strain values of the prosthesis were greater than that of the opposite edge jaw position when the tooth tip was interlaced.The equivalent stress and equivalent strain values of the screw were smaller than that of the opposite edge jaw position when the tooth tip was interlaced.(3)The results showed that the design and retention of the personalized GYROID condylar prosthesis were good,which was consistent with the mechanical conduction of the mandible.
5.Resting brain function study of executive function changes in patients with type 2 diabetes mellitus
Yanyan CUI ; Ying YU ; Bo HU ; Sining LI ; Xinyu CAO ; Pan DAI ; Minhua NI ; Xiaoyan BAI ; Yao TONG ; Lijuan DU ; Linfeng YAN ; Guangbin CUI
Journal of Practical Radiology 2025;41(9):1427-1431
Objective To explore the changes in neural activity in patients with type 2 diabetes mellitus(T2DM)and their corre-lation with executive function,and to analyze the neural mechanisms underlying the decline in executive function in T2DM patients.Methods Thirty-one T2DM patients(T2DM group)and thirty-two healthy controls(HC)(HC group)matched for body mass index(BMI)underwent resting-state functional magnetic resonance imaging(rs-fMRI)scans and N-back task tests were included.Differ-ences in the amplitude of low-frequency fluctuation(ALFF),regional homogeneity(ReHo),and seed-based functional connectivity(FC)between the two groups were compared,and partial correlation analyses were performed between the difference results and N-back task performance.Results The T2DM group showed prolonged reaction time(RT)in the 1-back and 2-back tasks.T2DM patients exhibited increased ALFF in the bilateral caudate nucleus,left medial superior frontal gyrus,and right postcentral gyrus,as well as elevated ReHo in the right putamen.FC analysis revealed significant alterations in FC between the caudate nucleus,putamen,and multiple brain regions in T2DM patients,with some of these FC changes significantly correlated with RT and accuracy(ACC)in the N-back task.Conclusion The decline in executive function in T2DM patients may be associated with abnormal neural activity in brain regions such as the striatum,salience network,and frontoparietal control network.FC further decreases under increased cognitive load.These findings provide evidence for the study of the neural mechanisms of executive function impairment in T2DM patients.
6.Biomechanical properties of Gyroid structured titanium bionic bone scaffolds for repairing segmental mandibular defects
Zhixiu JIANG ; Yuchen JI ; Danyu LIU ; Yilin CAO ; Tingting JIANG ; Yihan SONG ; Lei WANG ; Xinyu WANG
Chinese Journal of Tissue Engineering Research 2025;29(22):4621-4628
BACKGROUND:Porous structures based on triple periodic minimal surfaces are one of the most promising orthopedic biostructures,among which the Gyroid structure is characterized by high specific surface area,high permeability,and zero mean curvature.OBJECTIVE:To screen the wall thickness interval of TC4 bionic bone scaffolds with 4 mm single-cell Gyroid structure matching the elastic modulus range of cancellous bone of the mandible through finite element analysis combined with mechanical compression test testing.METHODS:The finite element model of the 4 mm single-cell Gyroid structure with different wall thickths(0.1,0.2,0.3,0.4,0.5,0.6,0.7,and 0.8 mm)was established.The equivalent elastic modulus of the Gyroid structure was analyzed,and the wall thickness interval of the Gyroid structure matching the elastic modulus range of the maxillary resinous bone was selected with different wall thicknesses of 0.2,0.3,0.4,0.5,0.6,and 0.7 mm,respectively.According to finite element analysis screening results,the material selected was Ti6Al4V.Selective laser melting was used to prepare 3D printed Gyroid structure specimens.The surface treatment was carried out by large-grained sand blasting and acid etching.The elastic modulus and compressive strength of the specimen were tested by mechanical compression experiment.RESULTS AND CONCLUSION:(1)The finite element analysis results showed that the equivalent elastic modulus of the Gyroid structure increased with the increase of wall thickness,and the equivalent elastic modulus of the Gyroid structure with wall thickness of 0.2-0.7 mm was within the range of the elastic modulus of the spongy bone of the mandible(1.5-4.0 GPa),which was used for 3D printing of the Gyroid structure specimen.(2)The mechanical compression test results showed that the elastic modulus and compressive strength of the Gyroid structural specimen increased with the increase of wall thickness,and the elastic modulus of the Gyroid structural specimen with wall thickness of 0.3-0.5 mm was within the range of the elastic modulus of the cancellous bone of the mandible.The compressive strength of the Gyroid specimen with 0.3-0.7 mm wall thickness was consistent with the mechanical properties of the mandible.(3)The results show that the Gyroid structure of 0.3-0.5 mm wall thickness is compatible with the range of elastic modulus of the mandible.
7.Three-dimensional finite element analysis of personalized orthodontic devices for 3D printed maxillary single-rooted rotated tooth
Yan ZHUANG ; Xinyu WANG ; Yilin CAO ; Yuanxin DING ; Jiaqi WANG ; Miao YU ; Chunyang LUAN ; Yuansheng DING
Chinese Journal of Tissue Engineering Research 2025;29(30):6409-6415
BACKGROUND:In orthodontic treatment,full-mouth treatment is usually used to treat single-root severely twisted teeth,and single-tooth treatment is less common.OBJECTIVE:To design a personalized orthodontic device based on biomechanical principles to address the rotation of teeth 11,12,13,21,22,and 23,and evaluate the device's impact on tooth movement using three-dimensional finite element method.METHODS:Based on the biomechanical principle of tooth rotation and movement,a personalized orthodontic device was made by digital design combined with three-dimensional printing,so that the personalized orthodontic device and the tooth formed an anchorage system.The absolute anchorage of the micro-implant was used to precisely control the single-root twisted tooth in the three-dimensional direction.The CBCT data of the maxillary alveolar bone and tooth tissue of a female volunteer were collected.The three-dimensional finite element models of the twisted tooth-periodontal ligament-maxillary bone-personalized orthodontic device were established using Mimics,Geomagic Wrap,SolidWorks,3-matic Research 15.0,and Ansys Workbench software.The equivalent stress distribution characteristics of the personalized orthodontic device,the movement trend of the tooth,and the equivalent stress distribution characteristics of the periodontal ligament were calculated under a thrust of 60 g.RESULTS AND CONCLUSION:(1)The maximum equivalent stress observed on the personalized orthodontic device was 47.71 MPa.(2)The initial tooth displacement under the device demonstrated a rotational trend.The peak equivalent stress in the periodontal ligament was concentrated at the neck,while lower stress was observed in the apex region.(3)The safety and feasibility of the personalized orthodontic device designed in this study for severely rotated single-rooted teeth were preliminarily verified through finite element analysis.
8.Three-dimensional finite element analysis of personalized orthodontic devices for 3D printed maxillary single-rooted rotated tooth
Yan ZHUANG ; Xinyu WANG ; Yilin CAO ; Yuanxin DING ; Jiaqi WANG ; Miao YU ; Chunyang LUAN ; Yuansheng DING
Chinese Journal of Tissue Engineering Research 2025;29(30):6409-6415
BACKGROUND:In orthodontic treatment,full-mouth treatment is usually used to treat single-root severely twisted teeth,and single-tooth treatment is less common.OBJECTIVE:To design a personalized orthodontic device based on biomechanical principles to address the rotation of teeth 11,12,13,21,22,and 23,and evaluate the device's impact on tooth movement using three-dimensional finite element method.METHODS:Based on the biomechanical principle of tooth rotation and movement,a personalized orthodontic device was made by digital design combined with three-dimensional printing,so that the personalized orthodontic device and the tooth formed an anchorage system.The absolute anchorage of the micro-implant was used to precisely control the single-root twisted tooth in the three-dimensional direction.The CBCT data of the maxillary alveolar bone and tooth tissue of a female volunteer were collected.The three-dimensional finite element models of the twisted tooth-periodontal ligament-maxillary bone-personalized orthodontic device were established using Mimics,Geomagic Wrap,SolidWorks,3-matic Research 15.0,and Ansys Workbench software.The equivalent stress distribution characteristics of the personalized orthodontic device,the movement trend of the tooth,and the equivalent stress distribution characteristics of the periodontal ligament were calculated under a thrust of 60 g.RESULTS AND CONCLUSION:(1)The maximum equivalent stress observed on the personalized orthodontic device was 47.71 MPa.(2)The initial tooth displacement under the device demonstrated a rotational trend.The peak equivalent stress in the periodontal ligament was concentrated at the neck,while lower stress was observed in the apex region.(3)The safety and feasibility of the personalized orthodontic device designed in this study for severely rotated single-rooted teeth were preliminarily verified through finite element analysis.
9.Three-dimensional finite element analysis of three-dimensional printed personalized orthodontic appliances for vertical movement of single teeth
Yilin CAO ; Xinyu WANG ; Yan ZHUANG ; Yaru WANG ; Zhixiu JIANG ; Danyu LIU ; Jiuxu MEN ; Yuansheng DING
Chinese Journal of Tissue Engineering Research 2025;29(16):3360-3368
BACKGROUND:Based on the principle of vertical tooth movement,a personalized orthodontic appliance is created through digital design combined with 3D printing,so that the personalized orthodontic appliance forms a support system with the individual incisors.With the help of the absolute support of the micro-implant,the single tooth is precisely controlled in a three-dimensional direction.OBJECTIVE:To design personalized orthodontic appliances with 11,12,21,and 22 intrusion and extrusion based on biomechanical principles,and analyze the safety of the personalized orthodontic appliances in terms of their movement effect on the teeth by means of the three-dimensional finite element method.METHODS:Three-dimensional finite element models of alveolar bone-periodontium-maxillary incisors-personalized cantilever micro-implant-connecting plates-personalized brackets in the maxillary anterior region(teeth numbers 11,12,21,and 22)were established using Mimics,Geomagic Wrap,SolidWorks,and Ansys Workbench software,respectively.Personalized orthodontic appliances with low pressure movement and extended movement were set up at each tooth position.The stress level of each component of the personalized orthodontic appliances was analyzed,and the tooth displacement and periodontal stress distribution were calculated under loading of 300 g tensile or thrust force.RESULTS AND CONCLUSION:(1)The maximum equivalent force on the personalized intrusion mobile orthodontic appliance was 162.90 MPa,and the maximum equivalent force on the personalized extrusion mobile orthodontic appliance was 239.57 MPa.The maximum equivalent stress on both devices was located in the vertical portion of the personalized bracket loading attachment.The equivalent stresses on each part of the personalized orthodontic appliance were all within the yield strength,and they had good safety.(2)The initial displacement of the teeth under the action of the personalized orthodontic appliances showed a tendency towards overall intrusion or extrusion,with the displacement in the vertical direction far exceeding that in the horizontal and sagittal directions.The equivalent stress peak appeared at the root tip or neck of the periodontal membrane,and the equivalent stress concentration area appeared in the periodontal membrane of the root apical region.(3)The results show that the personalized orthodontic appliance allows 11,12,21,and 22 to approximate either intrusion movement or extrusion movement,initially confirming the effectiveness of the personalized vertical movement orthodontic appliance.
10.Personalized GYROID condylar prosthesis:design and finite element analysis
Danyu LIU ; Tingting JIANG ; Zhixiu JIANG ; Yuchen JI ; Yilin CAO ; Lei WANG ; Yucheng SU ; Xinyu WANG
Chinese Journal of Tissue Engineering Research 2025;29(17):3548-3556
BACKGROUND:Currently,the mandibular joint prosthesis manufactured at home and abroad needs to rely on screws to fix the condylar part of the prosthesis during the replacement process,and the retention hole is reserved to facilitate the operation during the operation.However,due to the lack of personalized jaw design,the reattachment plate may not fit the jaw,resulting in screw loosening and dislocation.Therefore,personalized condylar prosthesis replacement is of great value in the repair of the temporomandibular joint.OBJECTIVE:To design a personalized condylar prosthesis with an internal GYROID for mandibular condylar repair and reconstruction.METHODS:The GYROID structure was selected in the Rhinoceros 7 software with the single cell size of 6 mm and the wall thickness of 0.2,0.3,0.4,0.5,0.6,0.7,0.8 mm.The mechanical properties of the GYROID structure were analyzed by finite element method.3D printing of GYROID structural test specimens with different wall thickness(0.2,0.3,0.4,0.5,0.6,0.7,and 0.8 mm)was performed to test the mechanical properties of the specimens through room temperature compression experiments.A wall thickness value conforming to the range of mandibular mechanical properties was selected through finite element analysis and room temperature compression test results.An adult male mandibular CT data were used for inverse modeling to design a condylar prosthesis with an internal GYROID.Finite element analysis was used to simulate the movement of the apical staggered position and the opposite-blade jaw position after condylar prosthesis replacement.RESULTS AND CONCLUSION:(1)The results of finite element analysis and room temperature compression experiment showed that the elastic modulus of the GYROID structure increased with the increase of wall thickness.The elastic modulus of the GYROID structure with wall thickness of 0.5-0.7 mm was within the range of the elastic modulus of the mandible(1.5-4.0 GPa).Therefore,the 6 mm monocellular GYROID structural model with a wall thickness of 0.6 mm was selected for the design of the condylar prosthesis.(2)The results of finite element analysis showed that the stress distribution of mandibular model was symmetrical.The stress distribution of the two types of occlusion was roughly the same,and the stress peak was not significantly different.The stress concentrated in the neck of the condylar prosthesis,and the stress on the replacement side was slightly larger than that on the healthy side.The maximum equivalent stress of the whole internal fixation model was 269.34 MPa,and the maximum equivalent stress of the screw was 20.14 MPa.The equivalent stress and equivalent strain values of the prosthesis were greater than that of the opposite edge jaw position when the tooth tip was interlaced.The equivalent stress and equivalent strain values of the screw were smaller than that of the opposite edge jaw position when the tooth tip was interlaced.(3)The results showed that the design and retention of the personalized GYROID condylar prosthesis were good,which was consistent with the mechanical conduction of the mandible.

Result Analysis
Print
Save
E-mail