1.An experimental study on distal locking of femoral intramedullary nail assisted by an intelligent orthopedic robot.
Kun WANG ; Cui XU ; Zhonghe WANG ; Junsong WANG ; Shaobo NIE ; Yanpeng ZHAO ; Wei ZHANG ; Ming HAO
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):129-133
OBJECTIVE:
To explore the advantages and effectiveness of the independently developed intelligent orthopedic robot-assisted distal locking of femoral intramedullary nails.
METHODS:
Thirty-two adult cadaveric femur specimens were randomly divided into two groups, with 16 specimens in each group. The experimental group used the intelligent orthopedic robot to assist in the distal locking of femoral intramedullary nail holes, while the control group used the traditional method of manual locking under X-ray fluoroscopy. The locking time, fluoroscopy times, and the success rate of first locking were recorded and compared between the two groups.
RESULTS:
The locking time of the experimental group was (273.94±38.67) seconds, which was shorter than that of the control group [(378.38±152.72) seconds], and number of fluoroscopies was (4.56±0.81) times, which was less than that of the control group [(8.00±3.98) times]. The differences were significant [ MD=73.054 (-37.187, 85.813), P=0.049; MD=1.969 (-1.437, 2.563), P=0.002]. The first locking success rate of the experimental group was 100% (16/16), which was significantly higher than that of the control group (68.75%, 11/16) ( P=0.043).
CONCLUSION
The efficiency of distal locking of femoral intramedullary nails assisted by the intelligent orthopedic robot is significantly higher than that of the traditional manual locking method under fluoroscopy, as it can markedly reduce the time required for distal locking of femoral intramedullary nails, decrease intraoperative radiation exposure, and increase the success rate of locking.
Humans
;
Fracture Fixation, Intramedullary/instrumentation*
;
Bone Nails
;
Fluoroscopy
;
Femur/diagnostic imaging*
;
Femoral Fractures/surgery*
;
Robotic Surgical Procedures/instrumentation*
;
Cadaver
;
Adult
;
Robotics
;
Male
2.Comparison of curettage vs. trephination technique for harvesting anterior iliac crest bone graft: A cadaveric study.
Albert CAKAR ; Omer Faruk EGERCI ; Fırat DOGRUOZ ; Ersin TASATAN ; Serra OZTURK ; Muzaffer SINDEL ; Ozkan KOSE
Chinese Journal of Traumatology 2025;28(2):151-156
PURPOSE:
The purpose of this cadaveric study was to compare the volume and weight of bone graft harvested using the curettage vs. the trephination technique from the anterior iliac crest.
METHODS:
Embalmed cadavers were studied in this experimental research. The right hemipelvis of each cadaver was used for the trephine bone harvesting technique, whereas the left hemipelvis was used for the conventional curettage technique. The weight and the volume of the harvested bone were measured and statistically compared between the 2 sides. The Wilcoxon Signed-Rank test was employed to compare the graft volume and weight obtained from the right and left sides of the hemipelvis.
RESULTS:
Ten embalmed adult cadavers were used in this study. All subjects were Caucasian males with a mean age of 59.8 years (range 44 - 73 years) at the time of death. A total of 81 cylindrical bone grafts were harvested from the right iliac crest. In 9 out of 81 (11.1%), the cortex of the ilium was penetrated by the chisel. The mean weight of the bone graft harvested with the trephine technique (26.97 ± 2.32) g was heavier than that harvested with the curettage technique (23.74 ± 2.09) g (p = 0.007). Similarly, the volume of the bone graft was higher in the trephine technique (8.40 ± 0.84) cm3 compared to the curettage technique (6.60 ± 1.26) cm3 (p = 0.011). The trephination technique lasted a mean of (12.76 ± 1.87) min (range 10.30-16.10 min), while the curettage technique lasted a mean of (14.53 ± 0.89) min (range 13.50-16.00 min) (p = 0.028).
CONCLUSION:
Harvesting anterior iliac crest bone graft with the trephine technique provides a higher bone volume and weight than the conventional curettage technique. The trephine technique might be advocated over the curettage technique, especially when a large amount of autologous bone graft is required. However, a meticulous harvesting technique should be followed to prevent complications. In particular, the three-dimensional anatomy should be kept in mind, and the depth of trephination should be well-controlled.
CLINICAL TRIAL REGISTRATION
Institutional Review Board registration: 2022/499.
Humans
;
Ilium/surgery*
;
Male
;
Middle Aged
;
Aged
;
Cadaver
;
Curettage/methods*
;
Tissue and Organ Harvesting/methods*
;
Bone Transplantation/methods*
;
Adult
;
Trephining/methods*
3.Morphometric and anatomic characteristics of pronator quadratus muscle.
Nurşen ZEYBEK ; Özcan GAYRETLI ; Yüsra Nur ŞANLITÜRK ; Ayşin KALE
Chinese Journal of Traumatology 2025;28(4):252-256
PURPOSE:
In surgical procedures commonly employed for the management of scaphoid and distal radial fractures, the incision and dissection of the pronator quadratus muscle play a pivotal role. Nevertheless, comprehensive investigations into the anatomical intricacies of the pronator quadratus muscle have been relatively scarce within the clinical community. In light of this, our study endeavors to make a substantive contribution to the medical literature by conducting a meticulous examination of the morphology and morphometry of this muscle.
METHODS:
This study is a cross-sectional observational study conducted on 22 cadaveric upper extremities (44 sides) preserved between January 2005 and December 2018 at Istanbul University. The study included specimens with intact dissection areas and no prior surgical intervention. Observations focused on the morphometry of the pronator quadratus muscle and related anatomical structures. Statistical analysis was performed using SPSS v23.0, employing Student's t-test and paired t-test, with significance set at p < 0.05.
RESULTS:
Significant differences were found in the morphometric measurements of the pronator quadratus muscle between the right and left upper extremities, particularly in the vertical distance between the proximal and distal attachment points of the pronator quadratus to the radius (p = 0.008). Additionally, significant differences were observed between male and female samples for radius length (p < 0.001), ulna length (p < 0.001), pronator quadratus width (p < 0.001), and the vertical distance between pronator quadratus attachment points on both the radius (p = 0.001) and ulna (p = 0.001). Furthermore, significant correlations were identified between radius length and parameters such as the vertical distance between pronator quadratus attachment points on both the radius (p = 0.002) and pronator quadratus width (p = 0.030), and between ulna length and parameters including the vertical distances on the radius (p = 0.001) and ulna (p = 0.024).
CONCLUSION
In light of our comprehensive analysis, which encompasses not only the anatomical features of the pronator quadratus muscle but also its vascular supply and the organization of its neurovascular structures, we posit that our study holds significant implications for the field of orthopedic surgery. We anticipate that this research will furnish valuable insights that can inform and enhance orthopedic procedures.
Humans
;
Female
;
Male
;
Cross-Sectional Studies
;
Muscle, Skeletal/anatomy & histology*
;
Cadaver
;
Aged
;
Middle Aged
4.Exploration of the Anatomical Methods for the Long Occipital Nerve.
Min WU ; Tian-Han HU ; Rang-Rang WU
Acta Academiae Medicinae Sinicae 2025;47(3):408-413
Objective To further clarify the anatomical features of the long occipital nerve and summarize the rapid anatomical method for it,thus providing an operational basis for anatomists.Methods The bilateral sides of the head and neck specimens of 38 adult formalin-fixed cadavers were dissected,with a total of 76 specimens.The lateral cervical region,the sternocleidomastoid region,and the occipital region were dissected.The dissection focused on the long occipital nerve,the location and adjacent structural characteristics of which were carefully observed.Results The long occipital nerve was dissected out from 76 specimens.Through the posterior margin line(PML)anatomical method,the long occipital nerve was identified 1-3 cm above the accessory nerve,near the posterior border of the deep surface of the upper sternocleidomastoid in 70(92.1%)specimens.Through the inflection point(IP)anatomical method,the long occipital nerve was observed within the range of the circle with a radius of about 1.5 cm and centered on the midpoint of the line between the tip of the mastoid process and the tip of the external occipital protuberance in 6(7.9%)specimens.Conclusions The long occipital nerve can be quickly found by the PML method or IP method.Although the long occipital nerve can definitely be identified by the IP method,the anatomical operation is difficult.
Humans
;
Cadaver
;
Spinal Nerves/anatomy & histology*
;
Neck/innervation*
;
Adult
5.Development and content validity of a low-fidelity simulator for transanal pull through in pediatric surgery.
Philippine Journal of Surgical Specialties 2025;80(2):55-55
INTRODUCTION
Simulation based training, which is hypothesized to increase skill proficiency among trainees, is currently gaining popularity in pediatric surgical training. High-fidelity simulators are expensive and not easily replicable in low to middle income countries; thus, the use of low-fidelity simulators are being suggested. This type of educational technique may have a role in complex procedures such as pull-through procedure among patients with Hirschsprung's disease. This study aimed to ascertain the development and associated validity of low-fidelity simulators for transanal pull-through among pediatric patients.
METHODSThis is a validation study of a low-fidelity simulator for transanal pullthrough in pediatric surgery. The model was assembled by carefully harvesting the anus, colon and rectum from a pig cadaver, ensuring the tissues remained intact including the perianal skin. These tissues were then mounted onto a specially designed basket that simulates the human pelvic cavity. The prototype model underwent initial testing to ensure anatomical accuracy and durability. A panel of five pediatric surgeons were tapped for content validation.
RESULTSThe overall validity index of the simulator was 1.00 which was high. All panel experts agreed on the anatomical realism, educational value, and alignment with training objectives. Some positive feedback on its use included its ability to accurately simulate the surgical procedure and its potential to reduce the learning curve for trainees. Another feedback is that it can help clinicians feel more prepared and comfortable when performing the procedure on actual patients after practicing on the simulator. No negative feedback were reported.
CONCLUSIONThe study showed that the use of an animal simulator for practicing transanal pullthrough in pediatric surgery is feasible and valid. This model has the potential to be adapted for educational purposes and hands-on training before doing actual case surgeries. The realistic anatomy and tactile feedback provided by the simulator can help trainees improve their skills and confidence in performing transanal pullthrough.
Human ; Surgical Procedures, Operative ; Hirschsprung Disease ; Cadaver ; Anal Canal ; Colon ; Rectum
6.Anatomical research of positional relationship between protective channel and sural nerve during Achilles tendon repair using channel assisted minimally invasive repair technique.
Zhonghe WANG ; Wenhao CAO ; Hongzhe QI ; Lingtong KONG ; Haoyu LIU ; Chen CHEN ; Lianhua LI ; Lijun SUN ; Hua CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(11):1325-1329
OBJECTIVE:
To evaluate the positional relationship between protective channel and sural nerve while treating acute Achilles tendon rupture with channel assisted minimally invasive repair (CAMIR) technique based on anatomical observations of cadaver specimens.
METHODS:
Twelve adult cadaveric lower limb specimens (6 left, 6 right) were utilized. A CAMIR device was implanted at a distance of 4 cm from the proximal end of the specimen to the Achilles tendon insertion. The skin was incised along the tendon's medial side, the sural nerve was dissected, and the positional relationship with the protective channel was observed. The distance from the sural nerve-Achilles tendon intersection to the calcaneal insertion, the vertical distance between protective channel and the calcaneal insertion, and the horizontal distance between the sural nerve and protective channel were measured by using vernier caliper.
RESULTS:
Anatomical examination demonstrated a variable positional relationship between the sural nerve and protective channel, with the sural nerve positioned above (8 specimens) or below (4 specimens) the protective channel. The distance from the sural nerve-Achilles tendon intersection to the calcaneal insertion was (105.67±14.94) mm, the vertical distance between protective channel and the calcaneal insertion was (93.20±9.57) mm, and the horizontal distance between the sural nerve and protective channel was (0.31±0.14) mm.
CONCLUSION
The use of CAMIR technique for the treatment of acute Achilles tendon rupture can effectively avoid iatrogenic injury to the sural nerve.
Humans
;
Achilles Tendon/injuries*
;
Sural Nerve/anatomy & histology*
;
Cadaver
;
Minimally Invasive Surgical Procedures/methods*
;
Tendon Injuries/surgery*
;
Rupture/surgery*
;
Adult
;
Male
;
Calcaneus/injuries*
;
Female
;
Plastic Surgery Procedures/methods*
7.Biomechanical study of screw implant angle in reconstruction of tibiofibular syndesmosis injury.
Lei ZHANG ; Minghui LI ; Mengyao ZHANG ; Jixiang XIONG ; Junqiu WANG ; Xin ZHOU ; Houyin SHI ; Guoyou WANG
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(12):1480-1485
OBJECTIVE:
To investigate ideal screw implant angle in reconstruction of tibiofibular syndesmosis injury by using a biomechanical test.
METHODS:
A total of 24 ankle specimens from adult cadavers were used as the tibiofibular syndesmosis injury model. According to the angle of screw placement, the tibiofibular syndesmosis injury models were randomly divided into groups A (0°), B (10°-15°), C (20°-25°), and D (30°-35°), and the screws were placed at a level 2 cm proximal to the ankle joint. The displacement of fibula was measured by biomechanical testing machine at neutral, dorsiflexion (10°), plantar flexion (15°), varus (10°), and valgus (15°) positions, with axial load of 0-700 N (pressure separation test). The displacement of fibula was also measured at neutral position by applying 0-5 N·m torque load during internal and external rotation (torsional separation test).
RESULTS:
In the pressure separation test, group C exhibited the smallest displacement under different positions and load conditions. At neutral position, significant differences were observed ( P<0.05) between group A and group C under load of 300-700 N, as well as between group B and group C under all load conditions. At dorsiflexion position, significant differences were observed ( P<0.05) between group A and group C under load of 500-700 N, as well as between groups B, D and group C under all load conditions, and the displacements under all load conditions were significantly smaller in group A than in group B ( P<0.05). At plantar flexion position, significant differences were observed ( P<0.05) between group D and group C under all load conditions. At valgus position, significant differences were observed ( P<0.05) between group A and group C under load of 400-700 N, as well as between groups B, D and group C under all load conditions. In the torsional separation test, group C exhibited the smallest displacement and group B had the largest displacement under different load conditions. During internal rotation, significant differences were observed ( P<0.05) between group B and group C under all load conditions, as well as between group D and group C at load of 3-5 N·m. During external rotation, significant differences were observed between groups B, D and group C under all load conditions ( P<0.05). No significant difference was detected between groups at the remaining load conditions ( P>0.05).
CONCLUSION
The ideal screw implant angle in reconstruction of tibiofibular syndesmosis injury was 20°-25°, which has a small displacement of fibula.
Humans
;
Bone Screws
;
Biomechanical Phenomena
;
Fibula/injuries*
;
Fracture Fixation, Internal/methods*
;
Adult
;
Ankle Joint/surgery*
;
Ankle Injuries/surgery*
;
Tibia/surgery*
;
Male
;
Range of Motion, Articular
;
Weight-Bearing
;
Female
;
Cadaver
;
Plastic Surgery Procedures/methods*
8.Modified Latarjet splitting subscapularis muscle under arthroscopy: an anatomical study based on axillary nerve, glenoid, and subscapularis muscle.
Xinzhi LIANG ; Daqiang LIANG ; Zhihe QIU ; Sheng LI ; Bing WU ; Hao LI ; Gang HUANG ; Wei LU ; Denghui XIE ; Haifeng LIU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(5):556-560
OBJECTIVE:
To testify the spatial relationship between the subscapularis muscle splitting window and the axillary nerve in modified arthroscopic Latarjet procedure, which could provide anatomical basis for the modification of the subscapularis muscle splitting.
METHODS:
A total of 29 adult cadaveric shoulder specimens were dissected layer by layer, and the axillary nerve was finally confirmed to walk on the front surface of the subscapularis muscle. Keeping the shoulder joint in a neutral position, the Kirschner wire was passed through the subscapularis muscle from back to front at the 4 : 00 position of the right glenoid circle (7 : 00 position of the left glenoid circle), and the anterior exit point (point A, the point of splitting subscapularis muscle during Latarjet procedure) was recorded. The vertical and horizontal distances between point A and the axillary nerve were measured respectively.
RESULTS:
In the neutral position of the shoulder joint, the distance between the point A and the axillary nerve was 27.37 (19.80, 34.55) mm in the horizontal plane and 16.67 (12.85, 20.35) mm in the vertical plane.
CONCLUSION
In the neutral position of the shoulder joint, the possibility of axillary nerve injury will be relatively reduced when radiofrequency is taken from the 4 : 00 position of the right glenoid (7 : 00 position of the left glenoid circle), passing through the subscapularis muscle posteriorly and anteriorly and splitting outward.
Adult
;
Humans
;
Shoulder
;
Rotator Cuff/surgery*
;
Arthroscopy/methods*
;
Scapula/surgery*
;
Shoulder Joint/surgery*
;
Cadaver
;
Joint Instability/surgery*
9.Postmortem Interval Estimation Using Protein Chip Technology Combined with Multivariate Analysis Methods.
Xu-Dong ZHANG ; Yao-Ru JIANG ; Xin-Rui LIANG ; Tian TIAN ; Qian-Qian JIN ; Xiao-Hong ZHANG ; Jie CAO ; Qiu-Xiang DU ; Jun-Hong SUN
Journal of Forensic Medicine 2023;39(2):115-120
OBJECTIVES:
To estimate postmortem interval (PMI) by analyzing the protein changes in skeletal muscle tissues with the protein chip technology combined with multivariate analysis methods.
METHODS:
Rats were sacrificed for cervical dislocation and placed at 16 ℃. Water-soluble proteins in skeletal muscles were extracted at 10 time points (0 d, 1 d, 2 d, 3 d, 4 d, 5 d, 6 d, 7 d, 8 d and 9 d) after death. Protein expression profile data with relative molecular mass of 14 000-230 000 were obtained. Principal component analysis (PCA) and orthogonal partial least squares (OPLS) were used for data analysis. Fisher discriminant model and back propagation (BP) neural network model were constructed to classify and preliminarily estimate the PMI. In addition, the protein expression profiles data of human skeletal muscles at different time points after death were collected, and the relationship between them and PMI was analyzed by heat map and cluster analysis.
RESULTS:
The protein peak of rat skeletal muscle changed with PMI. The result of PCA combined with OPLS discriminant analysis showed statistical significance in groups with different time points (P<0.05) except 6 d, 7 d and 8 d after death. By Fisher discriminant analysis, the accuracy of internal cross-validation was 71.4% and the accuracy of external validation was 66.7%. The BP neural network model classification and preliminary estimation results showed the accuracy of internal cross-validation was 98.2%, and the accuracy of external validation was 95.8%. There was a significant difference in protein expression between 4 d and 25 h after death by the cluster analysis of the human skeletal muscle samples.
CONCLUSIONS
The protein chip technology can quickly, accurately and repeatedly obtain water-soluble protein expression profiles in rats' and human skeletal muscles with the relative molecular mass of 14 000-230 000 at different time points postmortem. The establishment of multiple PMI estimation models based on multivariate analysis can provide a new idea and method for PMI estimation.
Animals
;
Humans
;
Rats
;
Multivariate Analysis
;
Postmortem Changes
;
Protein Array Analysis
;
Technology
10.Task-oriented learning in head and neck anatomy using virtual, formalin-preserved, soft-embalmed, and plastinated cadavers
Ryner Jose D. Carrillo ; Karen June P. Dumlao ; Jacob Ephraim D. Salud ; Eljohn C. Yee ; Jose V. Tecson, III ; Charlotte M. Chiong
Acta Medica Philippina 2023;57(10):32-38
Background and Objective:
The COVID 19 pandemic has changed the way the human anatomy is taught. A necessary shift towards online instruction, combined with a decrease in cadaver donation has resulted in the need for maximizing formalinized, soft-embalmed, computerized, and plastinated cadaver specimens. Task-oriented activities allow students to demonstrate acquired knowledge and skills. It is the aim of this study to get the perspective of students in the utilization of available laboratory materials.
Methods:
One hundred forty-three students participated in task-oriented activities. Students demonstrated anatomy of the facial nerve, recurrent laryngeal nerve, and phrenic nerve by parotidectomy, thyroidectomy, and posterior neck dissection using formalinized cadaver and VH dissector™. Deep neck and sagittal structures in the plastinated specimen were identified using laser pointers. Ossicular mobility of the middle ear, and endoscopy of the nose and larynx were demonstrated using the soft embalmed cadaver. Students were surveyed on their perceptions on the utility of each cadaver specimen.
Results:
Formalinized and soft-embalmed cadaver were observed to present the most accurate anatomy, while the virtual dissector and plastinated specimens were seen to be the most sustainable and reusable.
Conclusion
Task-oriented learning in head and neck anatomy may use different cadaveric materials with varied accuracy and utility.
Anatomy
;
Cadaver
;
Education, Medical


Result Analysis
Print
Save
E-mail