1.Prevalence and characteristics of impacted teeth in Korean orthodontic patients at ten university dental hospitals
Youn-Kyung CHOI ; Sung-Hun KIM ; Yong-Il KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Dong-Soon CHOI ; Ho-Jin KIM ; Kyung-A KIM ; Mo-Hyeon LEE ; Sung-Hwan CHOI ; Sung-Kwon CHOI ; Kyungmin Clara LEE ; Young-Mi JEON ; Sewoong OH ; Seorin JEONG
The Korean Journal of Orthodontics 2025;55(3):234-241
Objective:
This study aimed to investigate the prevalence and characteristics of impacted teeth (ITs) in orthodontic patients at university dental hospitals in Korea.
Methods:
This study included 14,774 patients who visited the Department of Orthodontics at 10 university dental hospitals in Korea between 2020 and 2022 and underwent orthodontic diagnosis. The prevalence and characteristics of ITs were investigated using orthodontic diagnostic records, radiographs, and diagnostic casts.
Results:
The prevalence of ITs, excluding third molar impaction, in Korean orthodontic patients was 13.6% (n = 2,014).The prevalence of ITs in pediatric orthodontic patients was 24.5% (n = 1,614).Of these patients, 68.2% had one IT, 27.5% had two ITs, 24.3% had bilateral IT, and 75.7% had unilateral IT. The most frequent IT was the maxillary canine (50.1%), followed by the mandibular second molar (11.7%), and maxillary second premolar (9.6%). An abnormal eruption path (46.5%) was the most frequent etiology. Orthodontic traction after surgical exposure (70.6%) was the most frequent treatment option. Among the patients with ITs, 29.8% had other dental anomalies, such as tooth agenesis (8.7%), microdontia (8.0%), and supernumerary teeth (5.1%). Furthermore, 50.8% had complications such as cystic lesions (18.3%), transposition (17.7%), and root resorption (14.8%).Among the patients with maxillary canine impaction, 62.2% had labial maxillary canine impaction and 21.1% had palatal maxillary canine impaction.
Conclusions
The prevalence of ITs in Korean orthodontic patients at university dental hospitals was high, particularly in pediatric orthodontic patients.
2.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
3.Prevalence and characteristics of impacted teeth in Korean orthodontic patients at ten university dental hospitals
Youn-Kyung CHOI ; Sung-Hun KIM ; Yong-Il KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Dong-Soon CHOI ; Ho-Jin KIM ; Kyung-A KIM ; Mo-Hyeon LEE ; Sung-Hwan CHOI ; Sung-Kwon CHOI ; Kyungmin Clara LEE ; Young-Mi JEON ; Sewoong OH ; Seorin JEONG
The Korean Journal of Orthodontics 2025;55(3):234-241
Objective:
This study aimed to investigate the prevalence and characteristics of impacted teeth (ITs) in orthodontic patients at university dental hospitals in Korea.
Methods:
This study included 14,774 patients who visited the Department of Orthodontics at 10 university dental hospitals in Korea between 2020 and 2022 and underwent orthodontic diagnosis. The prevalence and characteristics of ITs were investigated using orthodontic diagnostic records, radiographs, and diagnostic casts.
Results:
The prevalence of ITs, excluding third molar impaction, in Korean orthodontic patients was 13.6% (n = 2,014).The prevalence of ITs in pediatric orthodontic patients was 24.5% (n = 1,614).Of these patients, 68.2% had one IT, 27.5% had two ITs, 24.3% had bilateral IT, and 75.7% had unilateral IT. The most frequent IT was the maxillary canine (50.1%), followed by the mandibular second molar (11.7%), and maxillary second premolar (9.6%). An abnormal eruption path (46.5%) was the most frequent etiology. Orthodontic traction after surgical exposure (70.6%) was the most frequent treatment option. Among the patients with ITs, 29.8% had other dental anomalies, such as tooth agenesis (8.7%), microdontia (8.0%), and supernumerary teeth (5.1%). Furthermore, 50.8% had complications such as cystic lesions (18.3%), transposition (17.7%), and root resorption (14.8%).Among the patients with maxillary canine impaction, 62.2% had labial maxillary canine impaction and 21.1% had palatal maxillary canine impaction.
Conclusions
The prevalence of ITs in Korean orthodontic patients at university dental hospitals was high, particularly in pediatric orthodontic patients.
4.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
5.Prevalence and characteristics of impacted teeth in Korean orthodontic patients at ten university dental hospitals
Youn-Kyung CHOI ; Sung-Hun KIM ; Yong-Il KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Dong-Soon CHOI ; Ho-Jin KIM ; Kyung-A KIM ; Mo-Hyeon LEE ; Sung-Hwan CHOI ; Sung-Kwon CHOI ; Kyungmin Clara LEE ; Young-Mi JEON ; Sewoong OH ; Seorin JEONG
The Korean Journal of Orthodontics 2025;55(3):234-241
Objective:
This study aimed to investigate the prevalence and characteristics of impacted teeth (ITs) in orthodontic patients at university dental hospitals in Korea.
Methods:
This study included 14,774 patients who visited the Department of Orthodontics at 10 university dental hospitals in Korea between 2020 and 2022 and underwent orthodontic diagnosis. The prevalence and characteristics of ITs were investigated using orthodontic diagnostic records, radiographs, and diagnostic casts.
Results:
The prevalence of ITs, excluding third molar impaction, in Korean orthodontic patients was 13.6% (n = 2,014).The prevalence of ITs in pediatric orthodontic patients was 24.5% (n = 1,614).Of these patients, 68.2% had one IT, 27.5% had two ITs, 24.3% had bilateral IT, and 75.7% had unilateral IT. The most frequent IT was the maxillary canine (50.1%), followed by the mandibular second molar (11.7%), and maxillary second premolar (9.6%). An abnormal eruption path (46.5%) was the most frequent etiology. Orthodontic traction after surgical exposure (70.6%) was the most frequent treatment option. Among the patients with ITs, 29.8% had other dental anomalies, such as tooth agenesis (8.7%), microdontia (8.0%), and supernumerary teeth (5.1%). Furthermore, 50.8% had complications such as cystic lesions (18.3%), transposition (17.7%), and root resorption (14.8%).Among the patients with maxillary canine impaction, 62.2% had labial maxillary canine impaction and 21.1% had palatal maxillary canine impaction.
Conclusions
The prevalence of ITs in Korean orthodontic patients at university dental hospitals was high, particularly in pediatric orthodontic patients.
6.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
7.Impact of HER2-Low Status on Pathologic Complete Response and Survival Outcome Among Breast Cancer Patients Undergoing Neoadjuvant Chemotherapy
Young Joo LEE ; Tae-Kyung YOO ; Sae Byul LEE ; Il Yong CHUNG ; Hee Jeong KIM ; Beom Seok KO ; Jong Won LEE ; Byung Ho SON ; Sei Hyun AHN ; Hyehyun JEONG ; Jae Ho JUNG ; Jin-Hee AHN ; Kyung Hae JUNG ; Sung-Bae KIM ; Hee Jin LEE ; Gyungyub GONG ; Jisun KIM
Journal of Breast Cancer 2025;28(1):11-22
Purpose:
This study analyzed the pathological complete response (pCR) rates, long-term outcomes, and biological features of human epidermal growth factor receptor 2 (HER2)-zero, HER2-low, and HER2-positive breast cancer patients undergoing neoadjuvant treatment.
Methods:
This single-center study included 1,667 patients who underwent neoadjuvant chemotherapy from 2008 to 2014. Patients were categorized by HER2 status, and their clinicopathological characteristics, chemotherapy responses, and recurrence-free survival (RFS) rates were analyzed.
Results:
Patients with HER2-low tumors were more likely to be older (p = 0.081), have a lower histological grade (p < 0.001), and have hormone receptor (HorR)-positive tumors (p < 0.001). The HER2-positive group exhibited the highest pCR rate (23.3%), followed by the HER2-zero (15.5%) and HER2-low (10.9%) groups. However, the pCR rate did not differ between HER2-low and HER2-zero tumors in the HorR-positive or HorR-negative subgroups.The 5-year RFS rates increased in the following order: HER2-low, HER2-positive, and HER2-zero (80.0%, 77.5%, and 74.5%, respectively) (log-rank test p = 0.017). A significant survival difference between patients with HER2-low and HER2-zero tumors was only identified in HorR-negative tumors (5-year RFS for HER2-low, 74.5% vs. HER2-zero, 66.0%; log-rank test p-value = 0.04). Multivariate survival analysis revealed that achieving a pCR was the most significant factor associated with improved survival (hazard ratio [HR], 4.279; p < 0.001).Compared with HER2-zero, the HRs for HER2-low and HER2-positive tumors were 0.787 (p = 0.042) and 0.728 (p = 0.005), respectively. After excluding patients who received HER2-targeted therapy, patients with HER2-low tumors exhibited better RFS than those with HER2-zero (HR 0.784, p = 0.04), whereas those with HER2-positive tumors exhibited no significant difference compared with those with HER2-low tumors (HR, 0.975; p = 0.953).
Conclusion
Patients with HER2-low tumors had no significant difference in pCR rate compared to HER2-zero but showed better survival, especially in HorR-negative tumors.Further investigation into biological differences is warranted.
8.Clinical practice guidelines for ovarian cancer: an update to the Korean Society of Gynecologic Oncology guidelines
Banghyun LEE ; Suk-Joon CHANG ; Byung Su KWON ; Joo-Hyuk SON ; Myong Cheol LIM ; Yun Hwan KIM ; Shin-Wha LEE ; Chel Hun CHOI ; Kyung Jin EOH ; Jung-Yun LEE ; Yoo-Young LEE ; Dong Hoon SUH ; Yong Beom KIM
Journal of Gynecologic Oncology 2025;36(1):e69-
We updated the Korean Society of Gynecologic Oncology (KSGO) practice guideline for the management of ovarian cancer as version 5.1. The ovarian cancer guideline team of the KSGO published announced the fifth version (version 5.0) of its clinical practice guidelines for the management of ovarian cancer in December 2023. In version 5.0, the selection of the key questions and the systematic reviews were based on the data available up to December 2022.Therefore, we updated the guidelines version 5.0 with newly accumulated clinical data and added 5 new key questions reflecting the latest insights in the field of ovarian cancer between 2023 and 2024. For each question, recommendation was provided together with corresponding level of evidence and grade of recommendation, all established through expert consensus.
9.Prevalence and characteristics of impacted teeth in Korean orthodontic patients at ten university dental hospitals
Youn-Kyung CHOI ; Sung-Hun KIM ; Yong-Il KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Dong-Soon CHOI ; Ho-Jin KIM ; Kyung-A KIM ; Mo-Hyeon LEE ; Sung-Hwan CHOI ; Sung-Kwon CHOI ; Kyungmin Clara LEE ; Young-Mi JEON ; Sewoong OH ; Seorin JEONG
The Korean Journal of Orthodontics 2025;55(3):234-241
Objective:
This study aimed to investigate the prevalence and characteristics of impacted teeth (ITs) in orthodontic patients at university dental hospitals in Korea.
Methods:
This study included 14,774 patients who visited the Department of Orthodontics at 10 university dental hospitals in Korea between 2020 and 2022 and underwent orthodontic diagnosis. The prevalence and characteristics of ITs were investigated using orthodontic diagnostic records, radiographs, and diagnostic casts.
Results:
The prevalence of ITs, excluding third molar impaction, in Korean orthodontic patients was 13.6% (n = 2,014).The prevalence of ITs in pediatric orthodontic patients was 24.5% (n = 1,614).Of these patients, 68.2% had one IT, 27.5% had two ITs, 24.3% had bilateral IT, and 75.7% had unilateral IT. The most frequent IT was the maxillary canine (50.1%), followed by the mandibular second molar (11.7%), and maxillary second premolar (9.6%). An abnormal eruption path (46.5%) was the most frequent etiology. Orthodontic traction after surgical exposure (70.6%) was the most frequent treatment option. Among the patients with ITs, 29.8% had other dental anomalies, such as tooth agenesis (8.7%), microdontia (8.0%), and supernumerary teeth (5.1%). Furthermore, 50.8% had complications such as cystic lesions (18.3%), transposition (17.7%), and root resorption (14.8%).Among the patients with maxillary canine impaction, 62.2% had labial maxillary canine impaction and 21.1% had palatal maxillary canine impaction.
Conclusions
The prevalence of ITs in Korean orthodontic patients at university dental hospitals was high, particularly in pediatric orthodontic patients.
10.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.

Result Analysis
Print
Save
E-mail