1.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
2.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
3.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
4.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
5.A randomized controlled trial comparing liquid skin adhesives and staplers for surgical wound management
Hyeon Woo BAE ; Seung Yoon YANG ; Ga Yoon KU ; Sohye LEE ; Eun-Joo JUNG ; Seulkee PARK ; Yoon Bin JUNG ; Jihong KIM ; Byung Soh MIN
Annals of Surgical Treatment and Research 2025;108(3):143-149
Purpose:
Despite the widespread use of liquid skin adhesives (LSA), concerns persist regarding the increase in wound care costs. This study aimed to investigate the cost-effectiveness of LSA for surgical wound management.
Methods:
In this prospective, open-label, single-center randomized controlled trial, adults aged 19 years and older who were scheduled for elective minimally invasive colorectal surgeries were included. The participants were randomly divided into 2 groups: an n-butyl cyanoacrylate skin adhesive was used in the experimental group (LSA group), while a surgical skin stapler was employed in the control group (stapler group). The primary outcome measure was the sum of the total time required for wound management.
Results:
A total of 58 patients were randomly assigned to 2 groups, with 29 patients in each group. The findings revealed comparable wound complication rates in the 2 groups (8 out of 29 in the LSA group vs. 5 out of 29 in the stapler group, P = 0.530). Notably, the LSA group had a significantly shorter wound management time (median 235 seconds vs. 1,201 seconds, P < 0.001) and similar wound management cost (median US dollar [USD] 50.6 vs. USD 54.6, P = 0.529) compared to the stapler group. Subgroup analysis showed that the LSA group had a shorter management time for uncomplicated wounds and a lower cost for complicated wounds.
Conclusion
LSA not only provides a safe alternative but also offers a resource-efficient option for wound management compared to staplers.
6.A randomized controlled trial comparing liquid skin adhesives and staplers for surgical wound management
Hyeon Woo BAE ; Seung Yoon YANG ; Ga Yoon KU ; Sohye LEE ; Eun-Joo JUNG ; Seulkee PARK ; Yoon Bin JUNG ; Jihong KIM ; Byung Soh MIN
Annals of Surgical Treatment and Research 2025;108(3):143-149
Purpose:
Despite the widespread use of liquid skin adhesives (LSA), concerns persist regarding the increase in wound care costs. This study aimed to investigate the cost-effectiveness of LSA for surgical wound management.
Methods:
In this prospective, open-label, single-center randomized controlled trial, adults aged 19 years and older who were scheduled for elective minimally invasive colorectal surgeries were included. The participants were randomly divided into 2 groups: an n-butyl cyanoacrylate skin adhesive was used in the experimental group (LSA group), while a surgical skin stapler was employed in the control group (stapler group). The primary outcome measure was the sum of the total time required for wound management.
Results:
A total of 58 patients were randomly assigned to 2 groups, with 29 patients in each group. The findings revealed comparable wound complication rates in the 2 groups (8 out of 29 in the LSA group vs. 5 out of 29 in the stapler group, P = 0.530). Notably, the LSA group had a significantly shorter wound management time (median 235 seconds vs. 1,201 seconds, P < 0.001) and similar wound management cost (median US dollar [USD] 50.6 vs. USD 54.6, P = 0.529) compared to the stapler group. Subgroup analysis showed that the LSA group had a shorter management time for uncomplicated wounds and a lower cost for complicated wounds.
Conclusion
LSA not only provides a safe alternative but also offers a resource-efficient option for wound management compared to staplers.
7.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
8.A randomized controlled trial comparing liquid skin adhesives and staplers for surgical wound management
Hyeon Woo BAE ; Seung Yoon YANG ; Ga Yoon KU ; Sohye LEE ; Eun-Joo JUNG ; Seulkee PARK ; Yoon Bin JUNG ; Jihong KIM ; Byung Soh MIN
Annals of Surgical Treatment and Research 2025;108(3):143-149
Purpose:
Despite the widespread use of liquid skin adhesives (LSA), concerns persist regarding the increase in wound care costs. This study aimed to investigate the cost-effectiveness of LSA for surgical wound management.
Methods:
In this prospective, open-label, single-center randomized controlled trial, adults aged 19 years and older who were scheduled for elective minimally invasive colorectal surgeries were included. The participants were randomly divided into 2 groups: an n-butyl cyanoacrylate skin adhesive was used in the experimental group (LSA group), while a surgical skin stapler was employed in the control group (stapler group). The primary outcome measure was the sum of the total time required for wound management.
Results:
A total of 58 patients were randomly assigned to 2 groups, with 29 patients in each group. The findings revealed comparable wound complication rates in the 2 groups (8 out of 29 in the LSA group vs. 5 out of 29 in the stapler group, P = 0.530). Notably, the LSA group had a significantly shorter wound management time (median 235 seconds vs. 1,201 seconds, P < 0.001) and similar wound management cost (median US dollar [USD] 50.6 vs. USD 54.6, P = 0.529) compared to the stapler group. Subgroup analysis showed that the LSA group had a shorter management time for uncomplicated wounds and a lower cost for complicated wounds.
Conclusion
LSA not only provides a safe alternative but also offers a resource-efficient option for wound management compared to staplers.
9.Spinal Cord Infarction Associated with Coronavirus Disease 2019: A Case Report with Magnetic Resonance Imaging Insights
Kyeongil MIN ; Myung Woo PARK ; Hyun Iee SHIN ; Byung Chan LEE ; Du Hwan KIM
Journal of Electrodiagnosis and Neuromuscular Diseases 2024;26(3):62-67
Coronavirus disease 2019 (COVID-19) has been associated with various neurological complications, including the rare occurrence of spinal cord infarction. In this report, we present the case of a 42-year-old man who developed sudden quadriplegia after being diagnosed with COVID-19. Initial magnetic resonance imaging (MRI) provided inconclusive results; however, subsequent imaging revealed diffusion restriction and vertebral body signal changes, indicative of ischemic changes in the spinal cord. The patient received anticoagulation and corticosteroid therapy followed by rehabilitation, resulting in partial recovery of motor function. This case illustrates the importance of considering spinal cord infarction in patients with COVID-19 who present with neurological symptoms. Furthermore, it highlights the crucial role of MRI, including diffusion-weighted imaging, in diagnosis.
10.The Third Nationwide Korean Heart Failure III Registry (KorHF III):The Study Design Paper
Minjae YOON ; Eung Ju KIM ; Seong Woo HAN ; Seong-Mi PARK ; In-Cheol KIM ; Myeong-Chan CHO ; Hyo-Suk AHN ; Mi-Seung SHIN ; Seok Jae HWANG ; Jin-Ok JEONG ; Dong Heon YANG ; Jae-Joong KIM ; Jin Oh CHOI ; Hyun-Jai CHO ; Byung-Su YOO ; Seok-Min KANG ; Dong-Ju CHOI
International Journal of Heart Failure 2024;6(2):70-75
With advancements in both pharmacologic and non-pharmacologic treatments, significant changes have occurred in heart failure (HF) management. The previous Korean HF registries, namely the Korea Heart Failure Registry (KorHF-registry) and Korean Acute Heart Failure Registry (KorAHF-registry), no longer accurately reflect contemporary acute heart failure (AHF) patients. Our objective is to assess contemporary AHF patients through a nationwide registry encompassing various aspects, such as clinical characteristics, management approaches, hospital course, and long-term outcomes of individuals hospitalized for AHF in Korea. This prospective observational multicenter cohort study (KorHF III) is organized by the Korean Society of Heart Failure. We aim to prospectively enroll 7,000 or more patients hospitalized for AHF at 47 tertiary hospitals in Korea starting from March 2018. Eligible patients exhibit signs and symptoms of HF and demonstrate either lung congestion or objective evidence of structural or functional cardiac abnormalities in echocardiography, or isolated right-sided HF. Patients will be followed up for up to 5 years after enrollment in the registry to evaluate long-term clinical outcomes. KorHF III represents the nationwide AHF registry that will elucidate the clinical characteristics, management strategies, and outcomes of contemporary AHF patients in Korea.

Result Analysis
Print
Save