1.Phenotype of Relapsing Myelin Oligodendrocyte Glycoprotein Antibody-Associated Disease in Children
Ji Yeon HAN ; Soo Yeon KIM ; Woojoong KIM ; Hunmin KIM ; Anna CHO ; Jieun CHOI ; Jong-Hee CHAE ; Ki Joong KIM ; Young Se KWON ; Il Han YOO ; Byung Chan LIM
Journal of Clinical Neurology 2025;21(1):65-73
Background:
and Purpose To determine the clinical phenotypes, relapse timing, treatment responses, and outcomes of children with relapsing myelin oligodendrocyte glycoprotein antibody-associated disease (MOGAD).
Methods:
We collected the demographic, clinical, laboratory, and radiological data of patients aged <18 years who had been diagnosed with MOGAD at Seoul National University Children’s Hospital between January 2010 and January 2022; 100 were identified as positive for MOG antibodies, 43 of whom experienced relapse.
Results:
The median age at onset was 7 years (range 2–16 years). The median number of relapses was 2 (range 1–8), and patients were followed up for a median of 65 months (range 5–214 months). The first relapse was experienced before 3 months from onset by 15 patients (34.9%). The most-common initial phenotypes were acute disseminated encephalomyelitis (n=17, 39.5%) and optic neuritis (ON; n=11, 25.6%). The most-common relapse phenotypes were neuromyelitis optica spectrum disorder (n=9, 20.9%), relapsing ON (n=6, 14.0%), and multiphasic disseminated encephalomyelitis (n=6, 14.0%). Many of the patients (n=18, 41.9%) were not specifically categorized. A high proportion of these patients had non-acute disseminated encephalomyelitis encephalitis. Atypical phenotypes such as prolonged fever or hemiplegic migraine-like episodes were also noted. Mycophenolate mofetil and cyclic immunoglobulin treatment significantly reduced the annual relapse rates.
Conclusions
Our 43 pediatric patients with relapsing MOGAD showed a tendency toward early relapse and various relapse phenotypes. The overall prognoses of these patients were good regardless of phenotype or response to second-line immunosuppressant treatment.
2.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
3.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
4.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
5.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
6.Phenotype of Relapsing Myelin Oligodendrocyte Glycoprotein Antibody-Associated Disease in Children
Ji Yeon HAN ; Soo Yeon KIM ; Woojoong KIM ; Hunmin KIM ; Anna CHO ; Jieun CHOI ; Jong-Hee CHAE ; Ki Joong KIM ; Young Se KWON ; Il Han YOO ; Byung Chan LIM
Journal of Clinical Neurology 2025;21(1):65-73
Background:
and Purpose To determine the clinical phenotypes, relapse timing, treatment responses, and outcomes of children with relapsing myelin oligodendrocyte glycoprotein antibody-associated disease (MOGAD).
Methods:
We collected the demographic, clinical, laboratory, and radiological data of patients aged <18 years who had been diagnosed with MOGAD at Seoul National University Children’s Hospital between January 2010 and January 2022; 100 were identified as positive for MOG antibodies, 43 of whom experienced relapse.
Results:
The median age at onset was 7 years (range 2–16 years). The median number of relapses was 2 (range 1–8), and patients were followed up for a median of 65 months (range 5–214 months). The first relapse was experienced before 3 months from onset by 15 patients (34.9%). The most-common initial phenotypes were acute disseminated encephalomyelitis (n=17, 39.5%) and optic neuritis (ON; n=11, 25.6%). The most-common relapse phenotypes were neuromyelitis optica spectrum disorder (n=9, 20.9%), relapsing ON (n=6, 14.0%), and multiphasic disseminated encephalomyelitis (n=6, 14.0%). Many of the patients (n=18, 41.9%) were not specifically categorized. A high proportion of these patients had non-acute disseminated encephalomyelitis encephalitis. Atypical phenotypes such as prolonged fever or hemiplegic migraine-like episodes were also noted. Mycophenolate mofetil and cyclic immunoglobulin treatment significantly reduced the annual relapse rates.
Conclusions
Our 43 pediatric patients with relapsing MOGAD showed a tendency toward early relapse and various relapse phenotypes. The overall prognoses of these patients were good regardless of phenotype or response to second-line immunosuppressant treatment.
7.Phenotype of Relapsing Myelin Oligodendrocyte Glycoprotein Antibody-Associated Disease in Children
Ji Yeon HAN ; Soo Yeon KIM ; Woojoong KIM ; Hunmin KIM ; Anna CHO ; Jieun CHOI ; Jong-Hee CHAE ; Ki Joong KIM ; Young Se KWON ; Il Han YOO ; Byung Chan LIM
Journal of Clinical Neurology 2025;21(1):65-73
Background:
and Purpose To determine the clinical phenotypes, relapse timing, treatment responses, and outcomes of children with relapsing myelin oligodendrocyte glycoprotein antibody-associated disease (MOGAD).
Methods:
We collected the demographic, clinical, laboratory, and radiological data of patients aged <18 years who had been diagnosed with MOGAD at Seoul National University Children’s Hospital between January 2010 and January 2022; 100 were identified as positive for MOG antibodies, 43 of whom experienced relapse.
Results:
The median age at onset was 7 years (range 2–16 years). The median number of relapses was 2 (range 1–8), and patients were followed up for a median of 65 months (range 5–214 months). The first relapse was experienced before 3 months from onset by 15 patients (34.9%). The most-common initial phenotypes were acute disseminated encephalomyelitis (n=17, 39.5%) and optic neuritis (ON; n=11, 25.6%). The most-common relapse phenotypes were neuromyelitis optica spectrum disorder (n=9, 20.9%), relapsing ON (n=6, 14.0%), and multiphasic disseminated encephalomyelitis (n=6, 14.0%). Many of the patients (n=18, 41.9%) were not specifically categorized. A high proportion of these patients had non-acute disseminated encephalomyelitis encephalitis. Atypical phenotypes such as prolonged fever or hemiplegic migraine-like episodes were also noted. Mycophenolate mofetil and cyclic immunoglobulin treatment significantly reduced the annual relapse rates.
Conclusions
Our 43 pediatric patients with relapsing MOGAD showed a tendency toward early relapse and various relapse phenotypes. The overall prognoses of these patients were good regardless of phenotype or response to second-line immunosuppressant treatment.
8.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
9.Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation method
Jong-Chan BAIK ; Youn-Kyung CHOI ; Yonghun CHO ; Yunju BAEK ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2024;54(6):359-373
Objective:
This study aimed to investigate the effect of three-dimensional (3D) printed clear aligners (CA) with different designs on the extrusion of mandibular premolars using a force/moment measurement system and digital image correlation (DIC).
Methods:
The forces and moments applied to the mandibular canines, first and second premolars were measured using a multi-axis force/ moment transducer when an extrusion of 0.5 mm was planned, assuming the mandibular first premolars were intruded by 1 mm. In addition, displacement and strain changes in the CA were analyzed using the DIC method. CA designs were categorized based on the presence of first premolar attachment and subdivided into equigingival margins, 1-mm extended margins, equi-margins with 1-mm thickness and height, and equi-margins with 1-mm reduced buccolingual width.The CA was printed directly at a thickness of 0.5 mm, and the experiments were conducted at 37°C.
Results:
The results showed that attachment played an important role in the extrusion of first premolars in both the force/moment measurement system and the DIC method. Intrusion was observed without attachment, even though extrusion was planned. CA designs apply greater force to the cervical region by extending the margin or reducing the buccolingual width, thereby improving extrusion efficiency.
Conclusions
Force and moment changes in direct 3D printed CA are complex and difficult to predict; however, modifying aligner designs, such as extending the margin or reducing buccolingual width, and using appropriate attachments could minimize unwanted tooth movement, optimize planned treatment, and increase treatment predictability.
10.Transradial Versus Transfemoral Access for Bifurcation Percutaneous Coronary Intervention Using SecondGeneration Drug-Eluting Stent
Jung-Hee LEE ; Young Jin YOUN ; Ho Sung JEON ; Jun-Won LEE ; Sung Gyun AHN ; Junghan YOON ; Hyeon-Cheol GWON ; Young Bin SONG ; Ki Hong CHOI ; Hyo-Soo KIM ; Woo Jung CHUN ; Seung-Ho HUR ; Chang-Wook NAM ; Yun-Kyeong CHO ; Seung Hwan HAN ; Seung-Woon RHA ; In-Ho CHAE ; Jin-Ok JEONG ; Jung Ho HEO ; Do-Sun LIM ; Jong-Seon PARK ; Myeong-Ki HONG ; Joon-Hyung DOH ; Kwang Soo CHA ; Doo-Il KIM ; Sang Yeub LEE ; Kiyuk CHANG ; Byung-Hee HWANG ; So-Yeon CHOI ; Myung Ho JEONG ; Hyun-Jong LEE
Journal of Korean Medical Science 2024;39(10):e111-
Background:
The benefits of transradial access (TRA) over transfemoral access (TFA) for bifurcation percutaneous coronary intervention (PCI) are uncertain because of the limited availability of device selection. This study aimed to compare the procedural differences and the in-hospital and long-term outcomes of TRA and TFA for bifurcation PCI using secondgeneration drug-eluting stents (DESs).
Methods:
Based on data from the Coronary Bifurcation Stenting Registry III, a retrospective registry of 2,648 patients undergoing bifurcation PCI with second-generation DES from 21 centers in South Korea, patients were categorized into the TRA group (n = 1,507) or the TFA group (n = 1,141). After propensity score matching (PSM), procedural differences, in-hospital outcomes, and device-oriented composite outcomes (DOCOs; a composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization) were compared between the two groups (772 matched patients each group).
Results:
Despite well-balanced baseline clinical and lesion characteristics after PSM, the use of the two-stent strategy (14.2% vs. 23.7%, P = 0.001) and the incidence of in-hospital adverse outcomes, primarily driven by access site complications (2.2% vs. 4.4%, P = 0.015), were significantly lower in the TRA group than in the TFA group. At the 5-year follow-up, the incidence of DOCOs was similar between the groups (6.3% vs. 7.1%, P = 0.639).
Conclusion
The findings suggested that TRA may be safer than TFA for bifurcation PCI using second-generation DESs. Despite differences in treatment strategy, TRA was associated with similar long-term clinical outcomes as those of TFA. Therefore, TRA might be the preferred access for bifurcation PCI using second-generation DES.

Result Analysis
Print
Save
E-mail