1.Ultrasonography: current status, challenges, and future directions.
Ultrasonography 2018;37(1):1-2
No abstract available.
Ultrasonography*
2.Analysis of Prognostic Factors Affecting Admission in Acute Alcohol-intoxicated Patients with Traumatic Brain Injury Visiting Emergency Room.
Dae Chan KIM ; Gu Hyun KANG ; Wonhee KIM ; Yong Soo JANG ; Hyun Young CHOI ; Jin Keun HA ; Ihn Geun CHOI ; Byung Kook LEE ; Oh Hyun KIM ; Ji Ho RYU ; Gyu Chong CHO ; Young Suk CHO ; Boseung KANG ; Ho Jung KIM ; Jeong Hun LEE ; Han Joo CHOI ; Seok Ran YEOM
Journal of the Korean Society of Emergency Medicine 2017;28(6):587-594
PURPOSE: This study analyzed the prognostic factors affecting admission in acute alcohol-intoxicated traumatic brain injury (TBI) patients visiting the emergency room. METHODS: A multicenter, retrospective observational study was conducted on 821 acute alcohol-intoxicated adult trauma patients, who visited 10 university hospital emergency centers from April to November 2016. The primary outcome was hospital admission. The secondary outcome was in-hospital mortality. RESULTS: One hundred sixty-eight patients diagnosed with acute alcohol-intoxicated TBI were analyzed. The increase in blood alcohol concentration was associated significantly with a mild decrease in admission (adjusted odds ratio, 0.993; 95% confidence interval, 0.989 to 0.998; p=0.01). Moderate to severe TBI patients showed a significant increase in admission compared to mild TBI patients (adjusted odds ratio, 12.449; 95% confidence interval, 3.316 to 46.743; p < 0.001). CONCLUSION: This study showed that the admission was inversely correlated with the blood alcohol concentration and is correlated directly with the increase in the severity in TBI. Therefore, emergency physicians may be required to identify the severity of TBI rapidly and accurately in acute alcohol-intoxicated trauma patients visiting the emergency room.
Adult
;
Alcohol Drinking
;
Blood Alcohol Content
;
Brain Injuries*
;
Emergencies*
;
Emergency Service, Hospital*
;
Hospital Mortality
;
Humans
;
Observational Study
;
Odds Ratio
;
Patient Admission
;
Prognosis
;
Retrospective Studies
3.Radiologic Findings in Extrapancreatic Solid Pseudopapillary Tumor with Aggressive Behavior: a Case Report.
Hye Won CHOI ; Hyun Jeong PARK ; Soon Auk HONG ; Sung Bin PARK ; Eun Sun LEE ; Hye Shin AHN ; Jong Beum LEE ; Byung Ihn CHOI
Journal of Korean Medical Science 2017;32(12):2079-2084
Solid pseudopapillary tumor (SPT) is a low grade malignant tumor in the pancreas, and extrapancreatic SPT is extremely rare. We report a case of a 61-year-old woman who complained abdominal pain with diffuse tenderness. She was diagnosed with extrapancreatic SPT with extensive peritoneal dissemination and hepatic metastases. Although a few cases have reported imaging findings of extrapancreatic SPT, there have been no reports of extrapancreatic SPT with aggressive tumor behavior and dismal prognosis. Although imaging features closely resembled those of classical pancreatic SPTs, malignant transformation of extrapancreatic SPT should be considered when focal discontinuity of the tumor capsule with ill-defined margin and invasion of adjacent structures were identified.
Abdominal Pain
;
Female
;
Humans
;
Middle Aged
;
Neoplasm Metastasis
;
Pancreas
;
Prognosis
;
Ultrasonography
4.Comparison of Multidetector CT and Gadobutrol-Enhanced MR Imaging for Evaluation of Small, Solid Pancreatic Lesions.
Tae Won CHOI ; Jeong Min LEE ; Jung Hoon KIM ; Mi Hye YU ; Joon Koo HAN ; Byung Ihn CHOI
Korean Journal of Radiology 2016;17(4):509-521
OBJECTIVE: To compare multidetector computed tomography (MDCT) and MRI for lesion conspicuity, as well as the detection and characterization of small solid pancreatic lesions (SPLs). MATERIALS AND METHODS: 193 patients with small SPLs (< 3 cm) and 52 patients with normal pancreas who underwent both multiphasic MDCT and gadobutrol-enhanced MRI were included in our study. Two radiologists blinded to the pathologic diagnoses independently reviewed those images, and determined the detection of "SPL per se" and "SPL in consideration of secondary features", the lesion conspicuity, the probability of pancreatic ductal adenocarcinoma (PDAC), and the most likely specific diagnosis. RESULTS: The sensitivity of MRI for "detection of SPL per se" was significantly higher than that of CT in both reviewers: 92.7% (179/193) and 97.9% (189/193), respectively, for reviewer 1 (p = 0.031) and 90.7% (175/193) and 99.5% (192/193), respectively, for reviewer 2 (p < 0.001). In addition, MRI provided better lesion conspicuity than MDCT for both reviewers (p < 0.001). However, CT and MRI did not show significant difference in sensitivity for "detection of SPL in consideration of secondary features", specificity for SPL detection, and differentiation of PDAC vs. non-PDAC (p > 0.05). The accuracies of CT and MRI for making a specific diagnosis were as follows: 85.7% (210/245) vs. 86.9% (213/245), respectively, for reviewer 1 (p = 0.736), and 91.8% (225/245) vs. 93.5% (229/245), respectively, for reviewer 2 (p = 0.454). CONCLUSION: MRI showed better lesion conspicuity than MDCT, but did not show significantly different diagnostic performance compared with MDCT for detecting and characterizing small SPLs.
Adenocarcinoma
;
Diagnosis
;
Humans
;
Magnetic Resonance Imaging*
;
Multidetector Computed Tomography
;
Pancreas
;
Pancreatic Ducts
;
Sensitivity and Specificity
5.Therapeutic Effects of Microbubbles Added to Combined High-Intensity Focused Ultrasound and Chemotherapy in a Pancreatic Cancer Xenograft Model.
Mi Hye YU ; Jae Young LEE ; Hae Ri KIM ; Bo Ram KIM ; Eun Joo PARK ; Hoe Suk KIM ; Joon Koo HAN ; Byung Ihn CHOI
Korean Journal of Radiology 2016;17(5):779-788
OBJECTIVE: To investigate whether high-intensity focused ultrasound (HIFU) combined with microbubbles enhances the therapeutic effects of chemotherapy. MATERIALS AND METHODS: A pancreatic cancer xenograft model was established using BALB/c nude mice and luciferase-expressing human pancreatic cancer cells. Mice were randomly assigned to five groups according to treatment: control (n = 10), gemcitabine alone (GEM; n = 12), HIFU with microbubbles (HIFU + MB, n = 11), combined HIFU and gemcitabine (HIGEM; n = 12), and HIGEM + MB (n = 13). After three weekly treatments, apoptosis rates were evaluated using the terminal deoxynucleotidyl transferase-mediated dUTP nick end-labeling assay in two mice per group. Tumor volume and bioluminescence were monitored using high-resolution 3D ultrasound imaging and in vivo bioluminescence imaging for eight weeks in the remaining mice. RESULTS: The HIGEM + MB group showed significantly higher apoptosis rates than the other groups (p < 0.05) and exhibited the slowest tumor growth. From week 5, the tumor-volume-ratio relative to the baseline tumor volume was significantly lower in the HIGEM + MB group than in the control, GEM, and HIFU + MB groups (p < 0.05). Despite visible distinction, the HIGEM and HIGEM + MB groups showed no significant differences. CONCLUSION: High-intensity focused ultrasound combined with microbubbles enhances the therapeutic effects of gemcitabine chemotherapy in a pancreatic cancer xenograft model.
Animals
;
Apoptosis
;
Drug Therapy*
;
Heterografts*
;
Humans
;
Mice
;
Mice, Nude
;
Microbubbles*
;
Pancreatic Neoplasms*
;
Therapeutic Uses*
;
Tumor Burden
;
Ultrasonography*
6.Patient Radiation Exposure During Diagnostic and Therapeutic Procedures for Intracranial Aneurysms: A Multicenter Study.
Yon Kwon IHN ; Bum Soo KIM ; Jun Soo BYUN ; Sang Hyun SUH ; Yoo Dong WON ; Deok Hee LEE ; Byung Moon KIM ; Young Soo KIM ; Pyong JEON ; Chang Woo RYU ; Sang Il SUH ; Dae Seob CHOI ; See Sung CHOI ; Jin Wook CHOI ; Hyuk Won CHANG ; Jae Wook LEE ; Sang Heum KIM ; Young Jun LEE ; Shang Hun SHIN ; Soo Mee LIM ; Woong YOON ; Hae Woong JEONG ; Moon Hee HAN
Neurointervention 2016;11(2):78-85
PURPOSE: To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms across multi-centers and propose a diagnostic reference level (DRL). MATERIALS AND METHODS: We studied a sample of 490 diagnostic and 371 therapeutic procedures for intracranial aneurysms, which were performed at 23 hospitals in Korea in 2015. Parameters including dose-area product (DAP), cumulative air kerma (CAK), fluoroscopic time and total angiographic image frames were obtained and analyzed. RESULTS: Total mean DAP, CAK, fluoroscopy time, and total angiographic image frames were 106.2 ± 66.4 Gy-cm2, 697.1 ± 473.7 mGy, 9.7 ± 6.5 minutes, 241.5 ± 116.6 frames for diagnostic procedures, 218.8 ± 164.3 Gy-cm², 3365.7 ± 2205.8 mGy, 51.5 ± 31.1 minutes, 443.5 ± 270.7 frames for therapeutic procedures, respectively. For diagnostic procedure, the third quartiles for DRLs were 144.2 Gy-cm² for DAP, 921.1 mGy for CAK, 12.2 minutes for fluoroscopy times and 286.5 for number of image frames, respectively. For therapeutic procedures, the third quartiles for DRLs were 271.0 Gy-cm² for DAP, 4471.3 mGy for CAK, 64.7 minutes for fluoroscopy times and 567.3 for number of image frames, respectively. On average, rotational angiography was used 1.5 ± 0.7 times/session (range, 0-4; n=490) for diagnostic procedures and 1.6 ± 1.2 times/session (range, 0-4; n=368) for therapeutic procedures, respectively. CONCLUSION: Radiation dose as measured by DAP, fluoroscopy time and image frames were lower in our patients compared to another study regarding cerebral angiography, and DAP was lower with fewer angiographic image frames for therapeutic procedures. Proposed DRLs can be used for quality assurance and patient safety in diagnostic and therapeutic procedures.
Angiography
;
Cerebral Angiography
;
Fluoroscopy
;
Humans
;
Intracranial Aneurysm*
;
Korea
;
Patient Safety
;
Radiation Exposure*
7.Dynamic Contrast-Enhanced MRI Using a Macromolecular MR Contrast Agent (P792): Evaluation of Antivascular Drug Effect in a Rabbit VX2 Liver Tumor Model.
Hee Sun PARK ; Joon Koo HAN ; Jeong Min LEE ; Young Il KIM ; Sungmin WOO ; Jung Hwan YOON ; Jin Young CHOI ; Byung Ihn CHOI
Korean Journal of Radiology 2015;16(5):1029-1037
OBJECTIVE: To evaluate the utility of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using macromolecular contrast agent (P792) for assessment of vascular disrupting drug effect in rabbit VX2 liver tumor models. MATERIALS AND METHODS: This study was approved by our Institutional Animal Care and Use Committee. DCE-MRI was performed with 3-T scanner in 13 VX2 liver tumor-bearing rabbits, before, 4 hours after, and 24 hours after administration of vascular disrupting agent (VDA), using gadomelitol (P792, n = 7) or low molecular weight contrast agent (gadoterate meglumine [Gd-DOTA], n = 6). P792 was injected at a of dose 0.05 mmol/kg, while that of Gd-DOTA was 0.2 mmol/kg. DCE-MRI parameters including volume transfer coefficient (K(trans)) and initial area under the gadolinium concentration-time curve until 60 seconds (iAUC) of tumors were compared between the 2 groups at each time point. DCE-MRI parameters were correlated with tumor histopathology. Reproducibility in measurement of DCE-MRI parameters and image quality of source MR were compared between groups. RESULTS: P792 group showed a more prominent decrease in K(trans) and iAUC at 4 hours and 24 hours, as compared to the Gd-DOTA group. Changes in DCE-MRI parameters showed a weak correlation with histologic parameters (necrotic fraction and microvessel density) in both groups. Reproducibility of DCE-MRI parameters and overall image quality was not significantly better in the P792 group, as compared to the Gd-DOTA group. CONCLUSION: Dynamic contrast-enhanced magnetic resonance imaging using a macromolecular contrast agent shows changes of hepatic perfusion more clearly after administration of the VDA. Gadolinium was required at smaller doses than a low molecular contrast agent.
Animals
;
Antineoplastic Agents/therapeutic use
;
Benzophenones/therapeutic use
;
Disease Models, Animal
;
Heterocyclic Compounds/administration & dosage/*chemistry
;
Liver Neoplasms/drug therapy/pathology/*radiography
;
*Magnetic Resonance Imaging
;
Male
;
Organometallic Compounds/administration & dosage/*chemistry
;
Rabbits
;
Reproducibility of Results
;
Valine/analogs & derivatives/therapeutic use
8.Reduced Field-of-View Diffusion-Weighted Magnetic Resonance Imaging of the Pancreas: Comparison with Conventional Single-Shot Echo-Planar Imaging.
Hyungjin KIM ; Jeong Min LEE ; Jeong Hee YOON ; Jin Young JANG ; Sun Whe KIM ; Ji Kon RYU ; Stephan KANNENGIESSER ; Joon Koo HAN ; Byung Ihn CHOI
Korean Journal of Radiology 2015;16(6):1216-1225
OBJECTIVE: To investigate the image quality (IQ) and apparent diffusion coefficient (ADC) of reduced field-of-view (FOV) di-ffusion-weighted imaging (DWI) of pancreas in comparison with full FOV DWI. MATERIALS AND METHODS: In this retrospective study, 2 readers independently performed qualitative analysis of full FOV DWI (FOV, 38 × 38 cm; b-value, 0 and 500 s/mm²) and reduced FOV DWI (FOV, 28 × 8.5 cm; b-value, 0 and 400 s/mm²). Both procedures were conducted with a two-dimensional spatially selective radiofrequency excitation pulse, in 102 patients with benign or malignant pancreatic diseases (mean size, 27.5 ± 14.4 mm). The study parameters included 1) anatomic structure visualization, 2) lesion conspicuity, 3) artifacts, 4) IQ score, and 5) subjective clinical utility for confirming or excluding initially considered differential diagnosis on conventional imaging. Another reader performed quantitative ADC measurements of focal pancreatic lesions and parenchyma. Wilcoxon signed-rank test was used to compare qualitative scores and ADCs between DWI sequences. Mann Whitney U-test was used to compare ADCs between the lesions and parenchyma. RESULTS: On qualitative analysis, reduced FOV DWI showed better anatomic structure visualization (2.76 ± 0.79 at b = 0 s/mm² and 2.81 ± 0.64 at b = 400 s/mm²), lesion conspicuity (3.11 ± 0.99 at b = 0 s/mm² and 3.15 ± 0.79 at b = 400 s/mm²), IQ score (8.51 ± 2.05 at b = 0 s/mm² and 8.79 ± 1.60 at b = 400 s/mm²), and higher clinical utility (3.41 ± 0.64), as compared to full FOV DWI (anatomic structure, 2.18 ± 0.59 at b = 0 s/mm² and 2.56 ± 0.47 at b = 500 s/mm²; lesion conspicuity, 2.55 ± 1.07 at b = 0 s/mm² and 2.89 ± 0.86 at b = 500 s/mm²; IQ score, 7.13 ± 1.83 at b = 0 s/mm² and 8.17 ± 1.31 at b = 500 s/mm²; clinical utility, 3.14 ± 0.70) (p < 0.05). Artifacts were significantly improved on reduced FOV DWI (2.65 ± 0.68) at b = 0 s/mm² (full FOV DWI, 2.41 ± 0.63) (p < 0.001). On quantitative analysis, there were no significant differences between the 2 DWI sequences in ADCs of various pancreatic lesions and parenchyma (p > 0.05). ADCs of adenocarcinomas (1.061 × 10⁻³ mm²/s ± 0.133 at reduced FOV and 1.079 × 10⁻³ mm²/s ± 0.135 at full FOV) and neuroendocrine tumors (0.983 × 10⁻³ mm²/s ± 0.152 at reduced FOV and 1.004 × 10⁻³ mm²/s ± 0.153 at full FOV) were significantly lower than those of parenchyma (1.191 × 10⁻³ mm²/s ± 0.125 at reduced FOV and 1.218 × 10⁻³ mm²/s ± 0.103 at full FOV) (p < 0.05). CONCLUSION: Reduced FOV DWI of the pancreas provides better overall IQ including better anatomic detail, lesion conspicuity and subjective clinical utility.
Adult
;
Aged
;
Artifacts
;
Diagnosis, Differential
;
*Diffusion Magnetic Resonance Imaging
;
*Echo-Planar Imaging
;
Female
;
Humans
;
Male
;
Middle Aged
;
Pancreas/*radiography
;
Pancreatic Diseases/pathology/*radiography
;
Pancreatic Neoplasms/pathology/radiography
;
Retrospective Studies
9.UltraFast Doppler ultrasonography for hepatic vessels of liver recipients: preliminary experiences.
Bo Yun HUR ; Jae Young LEE ; A Jung CHU ; Se Hyung KIM ; Joon Koo HAN ; Byung Ihn CHOI
Ultrasonography 2015;34(1):58-65
PURPOSE: The purpose of this study was to investigate the value of UltraFast Doppler ultrasonography (US) for evaluating hepatic vessels in liver recipients. METHODS: Thirty-nine liver Doppler US sessions were conducted in 20 liver recipients. Each session consisted of UltraFast and conventional liver Doppler US in a random order. We compared the velocities and phasicities of the hepatic vessels, duration of each Doppler study, occurrence of technical failures, and differences in clinical decisions. RESULTS: The velocities and resistive index values of hepatic vessels showed a strong positive correlation between the two Doppler studies (mean R=0.806; range, 0.710 to 0.924). The phasicities of the hepatic vessels were the same in both Doppler US exams. With respect to the duration of the Doppler US exam, there was no significant difference between the UltraFast (251+/-99 seconds) and conventional (231+/-117 seconds) Doppler studies (P=0.306). In five poor breath-holders, in whom the duration of conventional Doppler US was longer, UltraFast Doppler US (272+/-157 seconds) required a shorter time than conventional Doppler US (381+/-133 seconds; P=0.005). There was no difference between the two techniques with respect to technical failures and clinical decisions. CONCLUSION: UltraFast Doppler US is clinically equivalent to conventional Doppler US with advantages for poor breath-holders during the post-liver transplantation work-up.
Liver Transplantation
;
Liver*
;
Ultrasonography, Doppler*
10.Monopolar Radiofrequency Ablation Using a Dual-Switching System and a Separable Clustered Electrode: Evaluation of the In Vivo Efficiency.
Jeong Hee YOON ; Jeong Min LEE ; Eui Jin HWANG ; In Pyung HWANG ; Jeehyun BAEK ; Joon Koo HAN ; Byung Ihn CHOI
Korean Journal of Radiology 2014;15(2):235-244
OBJECTIVE: To determine the in vivo efficiency of monopolar radiofrequency ablation (RFA) using a dual-switching (DS) system and a separable clustered (SC) electrode to create coagulation in swine liver. MATERIALS AND METHODS: Thirty-three ablation zones were created in nine pigs using a DS system and an SC electrode in the switching monopolar mode. The pigs were divided into two groups for two experiments: 1) preliminary experiments (n = 3) to identify the optimal inter-electrode distances (IEDs) for dual-switching monopolar (DSM)-RFA, and 2) main experiments (n = 6) to compare the in vivo efficiency of DSM-RFA with that of a single-switching monopolar (SSM)-RFA. RF energy was alternatively applied to one of the three electrodes (SSM-RFA) or concurrently applied to a pair of electrodes (DSM-RFA) for 12 minutes in in vivo porcine livers. The delivered RFA energy and the shapes and dimensions of the coagulation areas were compared between the two groups. RESULTS: No pig died during RFA. The ideal IEDs for creating round or oval coagulation area using the DSM-RFA were 2.0 and 2.5 cm. DSM-RFA allowed more efficient RF energy delivery than SSM-RFA at the given time (23.0 +/- 4.0 kcal vs. 16.92 +/- 2.0 kcal, respectively; p = 0.0005). DSM-RFA created a significantly larger coagulation volume than SSM-RFA (40.4 +/- 16.4 cm3 vs. 20.8 +/- 10.7 cm3; p < 0.001). Both groups showed similar circularity of the ablation zones (p = 0.29). CONCLUSION: Dual-switching monopolar-radiofrequency ablation using an SC electrode is feasible and can create larger ablation zones than SSM-RFA as it allows more RF energy delivery at a given time.
Animals
;
Catheter Ablation/*instrumentation/*methods
;
*Electrodes
;
Feasibility Studies
;
Liver/*surgery
;
Male
;
Sus scrofa
;
Time Factors

Result Analysis