1.Analysis of Brain-Computer Interface Technology in the Medical Field and the Regulation of the US FDA.
Jiaying GUO ; Jieying YANG ; Yaohua LI
Chinese Journal of Medical Instrumentation 2025;49(1):96-102
Brain-computer interface (BCI) technology is an innovative and cutting-edge medical advancement that enables direct interaction between the brain and external devices, facilitating the reconstruction of daily functions for patients or serving as a method for neuro-regulation therapy. Although this technology offers a broad range of clinical applications, there are problems as potential risks, individual variations, and the need for long-term monitoring of its effects during utilization. Consequently, the comprehensive evaluation of its safety and effectiveness poses a considerable challenge for regulatory agencies. This study provides a concise introduction to the development history and various types of BCI technology, followed by a summary of the regulatory situation for different types of BCI medical devices in the United States. Furthermore, the regulatory requirements imposed by the US FDA on this product category are analyzed. Finally, the article concludes by presenting a summary and future perspective on the current development of BCI technology, with the aim of offering beneficial insights and guidance for the regulation of BCI medical devices.
Brain-Computer Interfaces
;
United States
;
United States Food and Drug Administration
;
Humans
;
Electroencephalography
2.Prospects and technical challenges of non-invasive brain-computer interfaces in manned space missions.
Yumeng JU ; Jiajun LIU ; Zejun LI ; Yiming LIU ; Hairuo HE ; Jin LIU ; Bangshan LIU ; Mi WANG ; Yan ZHANG
Journal of Central South University(Medical Sciences) 2025;50(8):1363-1370
During long-duration manned space missions, the complex and extreme space environment exerts significant impacts on astronauts' physiological, psychological, and cognitive functions, thereby posing direct risks to mission safety and operational efficiency. As a key bridge between the brain and external devices, brain-computer interface (BCI) technology enables precise acquisition and interpretation of neural signals, offering a novel paradigm for human-machine collaboration in manned spaceflight. Non-invasive BCI technology shows broad application prospects across astronaut selection, mission training, in-orbit task execution, and post-mission rehabilitation. During mission preparation, multimodal signal assessment and neurofeedback training based on BCI can effectively enhance cognitive performance and psychological resilience. During mission execution, BCI can provide real-time monitoring of physiological and psychological states and enable intention-based device control, thereby improving operational efficiency and safety. In the post-mission rehabilitation phase, non-invasive BCI combined with neuromodulation may improve emotional and cognitive functions, support motor and cognitive recovery, and contribute to long-term health management. However, the application of BCI in space still faces challenges, including insufficient signal robustness, limited system adaptability, and suboptimal data processing efficiency. Looking forward, integrating multimodal physiological sensors with deep learning algorithms to achieve accurate monitoring and individualized intervention, and combining BCI with virtual reality and robotics to develop intelligent human-machine collaboration models, will provide more efficient support for space missions.
Brain-Computer Interfaces
;
Humans
;
Space Flight
;
Astronauts/psychology*
;
Neurofeedback
;
Cognition
;
Electroencephalography
;
Man-Machine Systems
3.A Method for Detecting Depression in Adolescence Based on an Affective Brain-Computer Interface and Resting-State Electroencephalogram Signals.
Zijing GUAN ; Xiaofei ZHANG ; Weichen HUANG ; Kendi LI ; Di CHEN ; Weiming LI ; Jiaqi SUN ; Lei CHEN ; Yimiao MAO ; Huijun SUN ; Xiongzi TANG ; Liping CAO ; Yuanqing LI
Neuroscience Bulletin 2025;41(3):434-448
Depression is increasingly prevalent among adolescents and can profoundly impact their lives. However, the early detection of depression is often hindered by the time-consuming diagnostic process and the absence of objective biomarkers. In this study, we propose a novel approach for depression detection based on an affective brain-computer interface (aBCI) and the resting-state electroencephalogram (EEG). By fusing EEG features associated with both emotional and resting states, our method captures comprehensive depression-related information. The final depression detection model, derived through decision fusion with multiple independent models, further enhances detection efficacy. Our experiments involved 40 adolescents with depression and 40 matched controls. The proposed model achieved an accuracy of 86.54% on cross-validation and 88.20% on the independent test set, demonstrating the efficiency of multimodal fusion. In addition, further analysis revealed distinct brain activity patterns between the two groups across different modalities. These findings hold promise for new directions in depression detection and intervention.
Humans
;
Male
;
Female
;
Adolescent
;
Case-Control Studies
;
Depression/diagnosis*
;
Early Diagnosis
;
Rest
;
Electroencephalography/methods*
;
Brain-Computer Interfaces
;
Models, Psychological
;
Reproducibility of Results
;
Affect/physiology*
;
Photic Stimulation/methods*
;
Video Recording
;
Brain/physiopathology*
4.A Personalized Predictor of Motor Imagery Ability Based on Multi-frequency EEG Features.
Mengfan LI ; Qi ZHAO ; Tengyu ZHANG ; Jiahao GE ; Jingyu WANG ; Guizhi XU
Neuroscience Bulletin 2025;41(7):1198-1212
A brain-computer interface (BCI) based on motor imagery (MI) provides additional control pathways by decoding the intentions of the brain. MI ability has great intra-individual variability, and the majority of MI-BCI systems are unable to adapt to this variability, leading to poor training effects. Therefore, prediction of MI ability is needed. In this study, we propose an MI ability predictor based on multi-frequency EEG features. To validate the performance of the predictor, a video-guided paradigm and a traditional MI paradigm are designed, and the predictor is applied to both paradigms. The results demonstrate that all subjects achieved > 85% prediction precision in both applications, with a maximum of 96%. This study indicates that the predictor can accurately predict the individuals' MI ability in different states, provide the scientific basis for personalized training, and enhance the effect of MI-BCI training.
Humans
;
Imagination/physiology*
;
Electroencephalography/methods*
;
Brain-Computer Interfaces
;
Male
;
Female
;
Adult
;
Young Adult
;
Brain/physiology*
;
Movement/physiology*
;
Motor Activity/physiology*
;
Psychomotor Performance/physiology*
5.Research on motor imagery recognition based on feature fusion and transfer adaptive boosting.
Yuxin ZHANG ; Chenrui ZHANG ; Shihao SUN ; Guizhi XU
Journal of Biomedical Engineering 2025;42(1):9-16
This paper proposes a motor imagery recognition algorithm based on feature fusion and transfer adaptive boosting (TrAdaboost) to address the issue of low accuracy in motor imagery (MI) recognition across subjects, thereby increasing the reliability of MI-based brain-computer interfaces (BCI) for cross-individual use. Using the autoregressive model, power spectral density and discrete wavelet transform, time-frequency domain features of MI can be obtained, while the filter bank common spatial pattern is used to extract spatial domain features, and multi-scale dispersion entropy is employed to extract nonlinear features. The IV-2a dataset from the 4 th International BCI Competition was used for the binary classification task, with the pattern recognition model constructed by combining the improved TrAdaboost integrated learning algorithm with support vector machine (SVM), k nearest neighbor (KNN), and mind evolutionary algorithm-based back propagation (MEA-BP) neural network. The results show that the SVM-based TrAdaboost integrated learning algorithm has the best performance when 30% of the target domain instance data is migrated, with an average classification accuracy of 86.17%, a Kappa value of 0.723 3, and an AUC value of 0.849 8. These results suggest that the algorithm can be used to recognize MI signals across individuals, providing a new way to improve the generalization capability of BCI recognition models.
Brain-Computer Interfaces
;
Humans
;
Support Vector Machine
;
Algorithms
;
Neural Networks, Computer
;
Imagination/physiology*
;
Pattern Recognition, Automated/methods*
;
Electroencephalography
;
Wavelet Analysis
6.Cross-session motor imagery-electroencephalography decoding with Riemannian spatial filtering and domain adaptation.
Lincong PAN ; Xinwei SUN ; Kun WANG ; Yupei CAO ; Minpeng XU ; Dong MING
Journal of Biomedical Engineering 2025;42(2):272-279
Motor imagery (MI) is a mental process that can be recognized by electroencephalography (EEG) without actual movement. It has significant research value and application potential in the field of brain-computer interface (BCI) technology. To address the challenges posed by the non-stationary nature and low signal-to-noise ratio of MI-EEG signals, this study proposed a Riemannian spatial filtering and domain adaptation (RSFDA) method for improving the accuracy and efficiency of cross-session MI-BCI classification tasks. The approach addressed the issue of inconsistent data distribution between source and target domains through a multi-module collaborative framework, which enhanced the generalization capability of cross-session MI-EEG classification models. Comparative experiments were conducted on three public datasets to evaluate RSFDA against eight existing methods in terms of classification accuracy and computational efficiency. The experimental results demonstrated that RSFDA achieved an average classification accuracy of 79.37%, outperforming the state-of-the-art deep learning method Tensor-CSPNet (76.46%) by 2.91% ( P < 0.01). Furthermore, the proposed method showed significantly lower computational costs, requiring only approximately 3 minutes of average training time compared to Tensor-CSPNet's 25 minutes, representing a reduction of 22 minutes. These findings indicate that the RSFDA method demonstrates superior performance in cross-session MI-EEG classification tasks by effectively balancing accuracy and efficiency. However, its applicability in complex transfer learning scenarios remains to be further investigated.
Electroencephalography/methods*
;
Brain-Computer Interfaces
;
Humans
;
Imagination/physiology*
;
Signal Processing, Computer-Assisted
;
Movement/physiology*
;
Signal-To-Noise Ratio
;
Deep Learning
;
Algorithms
7.Evaluation methods for the rehabilitation efficacy of bidirectional closed-loop motor imagery brain-computer interface active rehabilitation training systems.
He PAN ; Peng DING ; Fan WANG ; Tianwen LI ; Lei ZHAO ; Wenya NAN ; Anmin GONG ; Yunfa FU
Journal of Biomedical Engineering 2025;42(3):431-437
The bidirectional closed-loop motor imagery brain-computer interface (MI-BCI) is an emerging method for active rehabilitation training of motor dysfunction, extensively tested in both laboratory and clinical settings. However, no standardized method for evaluating its rehabilitation efficacy has been established, and relevant literature remains limited. To facilitate the clinical translation of bidirectional closed-loop MI-BCI, this article first introduced its fundamental principles, reviewed the rehabilitation training cycle and methods for evaluating rehabilitation efficacy, and summarized approaches for evaluating system usability, user satisfaction and usage. Finally, the challenges associated with evaluating the rehabilitation efficacy of bidirectional closed-loop MI-BCI were discussed, aiming to promote its broader adoption and standardization in clinical practice.
Brain-Computer Interfaces
;
Humans
;
Imagination/physiology*
;
Imagery, Psychotherapy/methods*
8.Brain-computer interface technology and its applications for patients with disorders of consciousness.
Jiahui PAN ; Zhihang ZHANG ; Yuanlin ZHANG ; Fei WANG ; Jun XIAO
Journal of Biomedical Engineering 2025;42(3):438-446
With the continuous advancement of neuroimaging technologies, clinical research has discovered the phenomenon of cognitive-motor dissociation in patients with disorders of consciousness (DoC). This groundbreaking finding has provided new impetus for the development and application of brain-computer interface (BCI) in clinic. Currently, BCI has been widely applied in DoC patients as an important tool for assessing and assisting behaviorally unresponsive individuals. This paper reviews the current applications of BCI in DoC patients, focusing four main aspects including consciousness detection, auxiliary diagnosis, prognosis assessment, and rehabilitation treatment. It also provides an in-depth analysis of representative key techniques and experimental outcomes in each aspect, which include BCI paradigm designs, brain signal decoding method, and feedback mechanisms. Furthermore, the paper offers recommendations for BCI design tailored to DoC patients and discusses future directions for research and clinical practice in this field.
Humans
;
Brain-Computer Interfaces
;
Consciousness Disorders/physiopathology*
;
Electroencephalography
;
Brain/physiopathology*
;
Consciousness
9.Detection of motor intention in patients with consciousness disorder based on electroencephalogram and functional near infrared spectroscopy combined with motor brain-computer interface paradigm.
Xiaoke CHAI ; Nan WANG ; Jiuxiang SONG ; Yi YANG
Journal of Biomedical Engineering 2025;42(3):447-454
Clinical grading diagnosis of disorder of consciousness (DOC) patients relies on behavioral assessment, which has certain limitations. Combining multi-modal technologies and brain-computer interface (BCI) paradigms can assist in identifying patients with minimally conscious state (MCS) and vegetative state (VS). This study collected electroencephalogram (EEG) and functional near-infrared spectroscopy (fNIRS) signals under motor BCI paradigms from 14 DOC patients, who were divided into two groups based on clinical scores: 7 in the MCS group and 7 in the VS group. We calculated event-related desynchronization (ERD) and motor decoding accuracy to analyze the effectiveness of motor BCI paradigms in detecting consciousness states. The results showed that the classification accuracies for left-hand and right-hand movement tasks using EEG were 93.28% and 76.19% for the MCS and VS groups, respectively; the classification precisions using fNIRS were 53.72% and 49.11% for these groups. When combining EEG and fNIRS features, the classification accuracies for left-hand and right-hand movement tasks in the MCS and VS groups were 95.56% and 87.38%, respectively. Although there was no statistically significant difference in motor decoding accuracy between the two groups, significant differences in ERD were observed between different consciousness states during left-hand movement tasks ( P < 0.001). This study demonstrates that motor BCI paradigms can assist in assessing the level of consciousness, with EEG being more sensitive for evaluating residual motor intention intensity. Moreover, the ERD feature of motor intention intensity is more sensitive than BCI classification accuracy.
Humans
;
Brain-Computer Interfaces
;
Spectroscopy, Near-Infrared/methods*
;
Electroencephalography/methods*
;
Consciousness Disorders/diagnosis*
;
Male
;
Movement
;
Adult
;
Female
;
Intention
;
Persistent Vegetative State/diagnosis*
10.A portable steady-state visual evoked potential brain-computer interface system for smart healthcare.
Yisen ZHU ; Zhouyu JI ; Shuran LI ; Haicheng WANG ; Yunfa FU ; Hongtao WANG
Journal of Biomedical Engineering 2025;42(3):455-463
This paper realized a portable brain-computer interface (BCI) system tailored for smart healthcare. Through the decoding of steady-state visual evoked potential (SSVEP), this system can rapidly and accurately identify the intentions of subjects, thereby meeting the practical demands of daily medical scenarios. Firstly, an SSVEP stimulation interface and an electroencephalogram (EEG) signal acquisition software were designed, which enable the system to execute multi-target and multi-task operations while also incorporating data visualization functionality. Secondly, the EEG signals recorded from the occipital region were decomposed into eight sub-frequency bands using filter bank canonical correlation analysis (FBCCA). Subsequently, the similarity between each sub-band signal and the reference signals was computed to achieve efficient SSVEP decoding. Finally, 15 subjects were recruited to participate in the online evaluation of the system. The experimental results indicated that in real-world scenarios, the system achieved an average accuracy of 85.19% in identifying the intentions of the subjects, and an information transfer rate (ITR) of 37.52 bit/min. This system was awarded third prize in the Visual BCI Innovation Application Development competition at the 2024 World Robot Contest, validating its effectiveness. In conclusion, this study has developed a portable, multifunctional SSVEP online decoding system, providing an effective approach for human-computer interaction in smart healthcare.
Brain-Computer Interfaces
;
Humans
;
Evoked Potentials, Visual/physiology*
;
Electroencephalography
;
Signal Processing, Computer-Assisted
;
Software
;
Adult
;
Male

Result Analysis
Print
Save