1.Research progress on valgus impacted proximal humeral fractures.
Bo LI ; Shimin CHANG ; Sunjun HU ; Shouchao DU ; Wenfeng XIONG
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):107-112
OBJECTIVE:
To review the advancement made in the understanding of valgus impacted proximal humeral fracture (PHF).
METHODS:
The domestic and foreign literature about the valgus impacted PHF was extensively reviewed and the definition, classification, pathological features, and treatment of valgus impacted PHFs were summarized.
RESULTS:
PHF with a neck shaft angle ≥160° is recognized as a valgus impacted PHF characterized by the preservation of the medial epiphyseal region of the humeral head, which contributes to maintenance of the medial periosteum's integrity after fracture and reduces the occurrence of avascular necrosis. Therefore, the valgus impacted PHF has a better prognosis when compared to other complex PHFs. The Neer classification designates it as a three- or four-part fracture, while the AO/Association for the Study of Internal Fixation (AO/ASIF) categorizes it as type C (C1.1). In the management of the valgus impacted PHF, the selection between conservative and surgical approaches is contingent upon the patient's age and the extent of fracture displacement. While conservative treatment offers the advantage of being non-invasive, it is accompanied by limitations such as the inability to achieve anatomical reduction and the potential for multiple complications. Surgical treatment includes open reduction combined with steel wire or locking plate and/or non-absorbable suture, transosseous suture technology, and shoulder replacement. Surgeons must adopt personalized treatment strategies for each patient with a valgus impacted PHF. Minimally invasive surgery helps to preserve blood supply to the humeral head, mitigate the likelihood of avascular necrosis, and reduce postoperative complications of bone and soft tissue. For elderly patients with severe comminuted and displaced fractures, osteoporosis, and unsuitable internal fixation, shoulder joint replacement is the best treatment option.
CONCLUSION
Currently, there has been some advancement in the classification, vascular supply, and management of valgus impacted PHF. Nevertheless, further research is imperative to assess the clinical safety, biomechanical stability, and indication of minimally invasive technology.
Aged
;
Humans
;
Bone Plates
;
Bone Wires
;
Fracture Fixation, Internal/adverse effects*
;
Fractures, Comminuted/surgery*
;
Humeral Fractures
;
Osteonecrosis
;
Retrospective Studies
;
Shoulder Fractures/surgery*
;
Treatment Outcome
2.Research progress on biomechanics for internal fixation in tibial plateau fracture.
Jialun LIU ; Yingze ZHANG ; Zhanle ZHENG
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):113-118
OBJECTIVE:
To review the biomechanical research progress of internal fixation of tibial plateau fracture in recent years and provide a reference for the selection of internal fixation in clinic.
METHODS:
The literature related to the biomechanical research of internal fixation of tibial plateau fracture at home and abroad was extensively reviewed, and the biomechanical characteristics of the internal fixation mode and position as well as the biomechanical characteristics of different internal fixators, such as screws, plates, and intramedullary nails were summarized and analyzed.
RESULTS:
Tibial plateau fracture is one of the common types of knee fractures. The conventional surgical treatment for tibial plateau fracture is open or closed reduction and internal fixation, which requires anatomical reduction and strong fixation. Anatomical reduction can restore the normal shape of the knee joint; strong fixation provides good biomechanical stability, so that the patient can have early functional exercise, restore knee mobility as early as possible, and avoid knee stiffness. Different internal fixators have their own biomechanical strengths and characteristics. The screw fixation has the advantage of being minimally invasive, but the fixation strength is limited, and it is mostly applied to Schatzker typeⅠfracture. For Schatzker Ⅰ-Ⅳ fracture, unilateral plate fixation can be used; for Schatzker Ⅴand Ⅵ fracture, bilateral plates fixation can be used to provide stronger fixation strength and avoid the stress concentration. The intramedullary nails fixation has the advantages of less trauma and less influence on the blood flow of the fracture end, but the fixation strength of the medial and lateral plateau is limited; so it is more suitable for tibial plateau fracture that involves only the metaphysis. Choosing the most appropriate internal fixation according to the patient's condition is still a major difficulty in the surgical treatment of tibial plateau fractures.
CONCLUSION
Each internal fixator has good fixation effect on tibial plateau fracture within the applicable range, and it is an important research direction to improve and innovate the existing internal fixator from various aspects, such as manufacturing process, material, and morphology.
Humans
;
Biomechanical Phenomena
;
Bone Plates
;
Fracture Fixation, Internal
;
Fracture Fixation, Intramedullary
;
Tibial Fractures/surgery*
;
Tibial Plateau Fractures
3.Osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation in treatment of tibial plateau fractures involving posterolateral column collapse.
Xuan PEI ; Guodong WANG ; Shenglong QIAN ; Yipeng CHENG ; Zhixun FANG ; Xi KE ; Ximing LIU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(4):410-416
OBJECTIVE:
To investigate the effectiveness of osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation in the treatment of tibial plateau fractures involving posterolateral column collapse.
METHODS:
A clinical data of 23 patients with tibial plateau fractures involving posterolateral column collapse, who had undergone osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation between January 2015 and June 2021, was retrospectively analyzed. There were 14 males and 9 females with an average age of 42.6 years ranging from 26 to 62 years. The causes of injury included traffic accident in 16 cases, falling from height in 5 cases, and other injuries in 2 cases. According to Schatzker classification, there were 15 cases of type Ⅴ and 8 cases of type Ⅵ. The time from injury to operation was 4-8 days with an average of 5.9 days. The operation time, intraoperative blood loss, fracture healing time, and complications were recorded. The depth of articular surface collapse of posterolateral column and posterior inclination angle (PSA) of the tibial plateau were compared before operation and at 2 days and 6 months after operation; fracture reduction of tibial plateau fracture was evaluated by Rasmussen anatomic score. The recovery of knee function was evaluated by Hospital for Special Surgery (HSS) score at 2 days and 6 months after operation.
RESULTS:
All 23 patients were completed the operation successfully. The operation time was 120-195 minutes, with an average of 152.8 minutes; the intraoperative blood loss was 50-175 mL, with an average of 109.5 mL. All patients were followed up 12-24 months, with an average of 16.7 months. One patient had superficial wound infection after operation, and the incision healed after dressing change; primary healing of incision of other patients was obtained. The fracture healing time was 12-18 weeks, with an average of 13.7 weeks. No failure of internal fixation, varus and valgus deformity of the knee joint, and instability of the knee joint was found at last follow-up. One patient developed joint stiffness and the range of motion of the knee joint was 10°-100°; the range of motion of the knee joint of other patients was 0°-125°. At 2 days and 6 months after operation, the depth of articular surface collapse of posterolateral column, PSA, and Rasmussen anatomic scores significantly improved when compared with those before operation ( P<0.05). There was no significant difference between the two postoperative time points ( P>0.05). The HSS score at 6 months after operation was significantly higher than that at 2 days after operation ( P<0.05).
CONCLUSION
For tibial plateau fractures involving posterolateral column collapse, reduction and internal fixation through osteotomy of non-core weight-bearing area of the lateral tibial plateau has the advantages of fully expose the posterolateral column fragment, good articular surface reduction, sufficient bone grafting, and fewer postoperative complications. It is beneficial to restore knee joint function and can be widely used in clinic.
Male
;
Female
;
Humans
;
Adult
;
Retrospective Studies
;
Blood Loss, Surgical
;
Tibial Plateau Fractures
;
Treatment Outcome
;
Bone Plates
;
Tibial Fractures/surgery*
;
Knee Joint
;
Fracture Fixation, Internal
;
Osteotomy
;
Weight-Bearing
4.Biomechanical effects of three internal fixation modes on femoral subtrochanteric spiral fractures in osteoporotic patients by finite element analysis.
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(6):688-693
OBJECTIVE:
The biomechanical characteristics of three internal fixation modes for femoral subtrochanteric spiral fracture in osteoporotic patients were compared and analyzed by finite element technology, so as to provide the basis for the optimization of fixation methods for femoral subtrochanteric spiral fracture.
METHODS:
Ten female patients with osteoporosis and femoral subtrochanteric spiral fractures caused by trauma, aged 65-75 years old, with a height of 160-170 cm and a body weight mass of 60-70 kg, were selected as the study subjects. The femur was scanned by spiral CT and a three-dimensional model of the femur was established by digital technology. The computer aided design models of proximal intramedullary nail (PFN), proximal femoral locking plate (PFLP), and the combination of the two (PFLP+PFN) were constructed under the condition of subtrochanteric fracture. Then the same load of 500 N was applied to the femoral head, and the stress distribution of the internal fixators, the stress distribution of the femur, and the displacement of femur after fracture fixation were compared and analyzed under the three finite element internal fixation modes, so as to evaluate the fixation effect.
RESULTS:
In the PFLP fixation mode, the stress of the plate was mainly concentrated in the main screw channel, the stresses of the different part of the plate were not equal, and gradually decreased from the head to the tail. In the PFN fixation mode, the stress was concentrated in the upper part of the lateral middle segment. In the PFLP+PFN fixation mode, the maximum stress appeared between the first and the second screws in the lower segment, and the maximum stress appeared in the lateral part of the middle segment of the PFN. The maximum stress of PFLP+PFN fixation mode was significantly higher than that of PFLP fixation mode, but significantly lower than that of PFN fixation mode ( P<0.05). In PFLP and PFN fixation modes, the maximum stress of femur appeared in the medial and lateral cortical bone of the middle femur and the lower side of the lowest screw. In PFLP+PFN fixation mode, the stress of femur concentrated in the medial and lateral of the middle femur. There was no significant difference in the maximum stress of femur among the three finite element fixation modes ( P>0.05). The maximum displacement occurred at the femoral head after three finite element fixation modes were used to fix subtrochanteric femoral fractures. The maximum displacement of femur in PFLP fixation mode was the largest, followed by PFN, and PFLP+PFN was the minimum, with significant differences ( P<0.05).
CONCLUSION
Under static loading conditions, the PFLP+PFN fixation mode produces the smallest maximum displacement when compared with the single PFN and PFLP fixation modes, but its maximum plate stress is greater than the single PFN and PFLP fixation mode, suggesting that the combination mode has higher stability, but the plate load is greater, and the possibility of fixation failure is higher.
Humans
;
Female
;
Aged
;
Finite Element Analysis
;
Biomechanical Phenomena
;
Fracture Fixation, Internal/methods*
;
Hip Fractures/surgery*
;
Bone Plates
;
Femur Head
;
Femoral Fractures/surgery*
5.Treatment analysis of complex Schatzker type Ⅳ tibial plateau fractures.
Xiao-Bin CHEN ; Meng LU ; Ben XIAO ; Dao-Jing QIU ; Yuan-Ming HE ; Xue-Jun LI
China Journal of Orthopaedics and Traumatology 2023;36(4):308-312
OBJECTIVE:
To explore treatment strategy for complex Schatzker Ⅳ tibial plateau fracture.
METHODS:
Forty-one patients with complex Schatzker type Ⅳ tibial plateau fractures were treated from January 2016 to January 2021, including 28 males and 13 females, aged from 19 to 65 years old with an average of (35.3±19.8) years old. Individualized treatment plan was developed according to preoperative imaging characteristics, medial surgical approach was mainly combined with other auxiliary incisions. Posteromedial inverted L approach was used in 18 patients, posteromedial approach and anterolateral extended approach in 19 patients, and posteromedial approach with anterolateral and lateral condylar osteotomy in 4 patients. Articular surface and facture healing were observed, range of knee joint motion was measured at 12 months after opertaion, and function of knee joint was evaluated by Lysholm scoring system.
RESULTS:
Forty-one patients were followed up for 12 to 26 months with an average of (13.3±6.8) months. Twenty-nine patients and 10 patients were obtained complete fracture healing at 6 and 12 months after operation respectively, and fracture healing time was 4 to 13 months with an average of (5.0±3.7) months. Two patients occurred posterior medial internal fixation failure and varus deformity of knee joint, and the fracture healed and varus deformity was corrected after the second operation. Range of knee joint motion was (118±29) °, and Lysholm score was(83.0±16.0) points.
CONCLUSION
Individualized treatment should be reasonably selected for complex Schatzker Ⅳ tibial plateau fractures, the characteristics of lateral plateau fractures are an important reference for selecting surgical approaches, the effective fixation of posteromedial bone blocks should be pay full attention, and the overall treatment results are satisfied.
Male
;
Female
;
Humans
;
Young Adult
;
Adult
;
Middle Aged
;
Aged
;
Adolescent
;
Tibial Plateau Fractures
;
Bone Plates
;
Tibial Fractures/surgery*
;
Treatment Outcome
;
Knee Joint/surgery*
;
Fracture Fixation, Internal/methods*
;
Retrospective Studies
6.Double-column Die-punch fractures of distal radius treated with butterfly plate fixation via Henry approach.
Hai-Bo XIA ; Jun LAN ; Li-Qing JIANG ; Hua-Fei YANG ; Xiao-Hui NIU
China Journal of Orthopaedics and Traumatology 2023;36(4):376-380
OBJECTIVE:
To explore clinical effect of open reduction and internal fixation with Henry's approach butterfly plate in treating double-column Die-punch fractures of distal radius.
METHODS:
From January 2018 to June 2021, 26 patients with double-column Die-column distal radius were treated with open reduction and internal fixation through Henry's surgical approach and using distal radius volar column plate(butterfly plate), including 14 males and 12 females, aged from 20 to 75 years old with an average age of (44.2±3.4) years old. Postopertaive complications were observed, Gartland-Werley score at 12 months after opertaion was used to evaluate wrist joint function.
RESULTS:
All 26 patients were followed up from 10 to 18 months with an average of(13.4±0.8) months. All fractures were obtained fracture union, the time ranged from 8.5 to 15.8 weeks with an average of (11.4±0.5) weeks. All incisions healed at stageⅠwithout infection, nerve injury and internal fixation failure occurred. Postoperative Gartland-Werley score at 12 months was (3.65±0.36), and 16 patients got excellent result, 8 good and 2 moderate.
CONCLUSION
Open reduction and internal fixation with butterfly plate for the treatment of double-column Die-punch fractures of the distal radius through volar Henry approach could obtain satisfactory clinical outcomes.
Adult
;
Aged
;
Animals
;
Female
;
Humans
;
Male
;
Middle Aged
;
Young Adult
;
Bone Plates
;
Fracture Fixation, Internal/methods*
;
Radius/surgery*
;
Radius Fractures/surgery*
;
Range of Motion, Articular
;
Treatment Outcome
;
Wrist Joint
7.Efficacy of micro steel plate and Kirschner needle oblique and transverse internal fixation of adjacent metacarpal bone in the treatment of metacarpal diaphyseal oblique fracture.
Li-Qi SHI ; Yang-Hua TANG ; Xiang-Jun LI ; Jun ZHAO ; Jie LIU
China Journal of Orthopaedics and Traumatology 2023;36(5):440-444
OBJECTIVE:
To compare the clinical efficacy of micro steel plate and Kirschner needle oblique and transverse internal fixation of adjacent metacarpal bone in the treatment of metacarpal diaphyseal oblique fracture.
METHODS:
Fifty-nine patients with metacarpal diaphyseal oblique fractures admitted between January 2018 and September 2021 were selected as the study subjects and divided into the observation group (29 cases) and the control group (30 cases) based on different internal fixation methods. The observation group was treated with Kirschner wire oblique and transverse internal fixation of adjacent metacarpal bones, while the control group was treated with micro steel plate internal fixation. Postoperative complications, operation time, incision length, fracture healing time, treatment cost, and metacarpophalangeal function were compared between the two groups.
RESULTS:
No incision or Kirschner wire infections occurred in the 59 patients, except for one in the observation group. No fixation loosening, rupture, or loss of fracture reduction occurred in any of the patients. The operation time and incision length in the observation group were (20.5±4.2) min and (1.6±0.2) cm, respectively, which were significantly shorter than those in the control group (30.8±5.6) min and (4.3±0.8) cm (P<0.05). The treatment cost and fracture healing time in the observation group were (3 804.5±300.8) yuan and (7.2±1.1) weeks, respectively, which were significantly lower than those in the control group (9 906.9±860.6) yuan and (9.3±1.7) weeks (P<0.05). The excellent and good rate of metacarpophalangeal joint function in the observation group was significantly higher than that in the control group at 1, 2, and 3 months after operation (P<0.05), but there was no significant difference between the two groups at 6 months after operation (P>0.05).
CONCLUSION
Micro steel plate internal fixation and Kirschner wire oblique and transverse internal fixation of adjacent metacarpal bones are both viable surgical methods for treating metacarpal diaphyseal oblique fractures. However, the latter has the advantages of causing less surgical trauma, shorter operation time, better fracture healing, lower cost of fixation materials, and no need for secondary incision and removal of internal fixation.
Humans
;
Metacarpal Bones/injuries*
;
Fractures, Bone/surgery*
;
Fracture Fixation, Internal/methods*
;
Bone Wires
;
Bone Plates
;
Treatment Outcome
8.Development and clinical application of a new reduction device for the treatment of tibial plateau fracture under arthroscopic monitoring.
Xing-Rui HUANG ; Yuan-Bin JIANG ; Chong-Shan YANG ; Hao XU ; Shu-Chen FANG ; Xiao-Wei CHEN ; Cheng CHEN ; Hao LI
China Journal of Orthopaedics and Traumatology 2023;36(6):570-573
OBJECTIVE:
To develop a reduction device for the arthroscopy-assisted treatment of tibial plateau fracture and explore its clinical efficacy.
METHODS:
From May 2018 to September 2019, 21 patients with tibial plateau fracture were treated, including 17 males and 4 females. Their ages ranged from 18 to 55 years old with an average of (38.6±8.7) years old. There were 5 cases of Schatzker typeⅡand 16 cases of Schatzker type Ⅲ. The self-designed reductor combined with arthroscope was used for auxiliary reduction and fixation(minimally invasive percutaneous plate osteosynthesis). The efficacy was analyzed by observing the operation time, blood loss, fracture healing time and knee function(HSS and IKDC scoring criteria).
RESULTS:
All the 21 patients were followed up for 8 to 24 with an average of(14.0±3.1) months. The operative time ranged from 70 to 95 min with an average of(81.7±7.6)min, incision length ranged from 4 to 7 cm with an average of(5.3±0.9) cm, intraoperative blood loss ranged from 20 to 50 ml with an average of(35.3±5.2) ml, postoperative weight-bearing time ranged from 30 to 50 d with an average of(35.1±9.2) d, fracture healing time ranged from 65 to 90 d with an average of(75.0±4.4) d, and complications were 0 cases, respectively. The fracture was well healed and no screw plate fracture was observed. The knee function scores of HSS and IKDC 18 months after operation were significantly higher than those before operation(P<0.05).
CONCLUSION
The custom-made reduction tool for the arthroscopic management of tibial plateau fracture is reasonable in design and simple in operation. The specific reduction tool could effectively reduce the fracture, and shorten the fixation time with minimally invasive procedure.
Male
;
Female
;
Humans
;
Adolescent
;
Young Adult
;
Adult
;
Middle Aged
;
Tibial Plateau Fractures
;
Tibial Fractures/surgery*
;
Fracture Fixation, Internal/methods*
;
Treatment Outcome
;
Bone Plates
;
Retrospective Studies
9.The analysis of the therapeutic effect for 10 cases of type C extreme distal radial fracture in micro needle plate internal fixation.
Bing LIU ; Xiang-Yu MA ; Chao YANG ; Da-Peng ZHOU
China Journal of Orthopaedics and Traumatology 2023;36(6):574-578
OBJECTIVE:
To analyze the clinical outcomes of mini-plate combined with wireforms in the treatment of Type C distal radial fractures with marginal articular fragments.
METHODS:
This retrospective study included a total of 10 cases, including 5 males and 5 females, with 6 cases involving the left side and 4 cases involving the right side, of Type C distal radial fractures with marginal articular fragments. The age of the patients ranged from 35 to 67 years old. All patients underwent surgical treatment utilizing mini-plate combined with wireforms for internal fixation.
RESULTS:
The follow-up period ranged from 6 to 18 months. Complete fracture healing was observed in all cases, with healing times ranging from 10 to 16 weeks. During the entire follow-up period, patients reported high levels of satisfaction with the treatment outcomes, and there were no incidences of incision infection, chronic wrist pain, or wrist traumatic arthritis. At the final follow-up assessment, the Mayo score for the wrist joint ranged from 85 to 95, with 7 cases rated as excellent and 3 cases as good.
CONCLUSION
Mini-plate combined with wireforms proves to be an effective fixation method for Type C distal radial fractures with marginal articular fragments. The early initiation of wrist joint exercises, strong fixation, maintenance of proper reduction, minimal complications, and high rates of excellent and good outcomes demonstrate the reliability and efficacy of this treatment approach.
Male
;
Female
;
Humans
;
Adult
;
Middle Aged
;
Aged
;
Retrospective Studies
;
Reproducibility of Results
;
Radius Fractures/surgery*
;
Fracture Fixation, Internal/methods*
;
Treatment Outcome
;
Wrist Fractures
;
Wrist Joint
;
Bone Plates
;
Range of Motion, Articular
10.Surgical treatment methods and classification of proximal clavicle fracture.
Qing-Song FU ; Xin-You HAN ; Wei-Bin WANG ; Xin-Hua YUAN ; Yi ZHENG
China Journal of Orthopaedics and Traumatology 2023;36(7):672-675
OBJECTIVE:
To summarize the surgical treatment of different proximal clavicle fractures, and discuss the classification of proximal clavicle fractures.
METHODS:
Total of 24 patients with displaced proximal clavicle fractures were treated from January 2017 to December 2020 including 16 males and 8 females, aged 28 to 66 years old. Among them, 20 cases were fresh fractures and 4 cases were old fractures. According to the Edinburgh classification, 14 cases were type 1B1 fractures and 10 cases were type 1B2 fractures. The different internal fixation methods were selected for internal fixation treatment according to different fracture types.The operation time, blood loss, preoperative and postoperative displacement difference, fracture healing time and Rockwood scoring system were recorded.
RESULTS:
All patients were followed up for 12 to 24 months. There were no patients with infection or loss of reduction after the operation. Three patients had internal fixation failure after operation, and the internal fixation device was removed. Results The operation time was 30 to 65 min, and the blood loss was 15 to 40 ml. No important nerves, blood vessels, or organs were damaged. The imaging healing time was 3 to 6 months. According to the Rockwood functional score, the total score was (13.50±1.86), pain (2.57±0.50), range of motion (2.78±0.41), muscle strength (2.93±0.28), restricted daily activity (2.85±0.35), subjective results (2.63±0.61);the results were excellent in 20 cases, good in 3 cases, fair in 1 case.
CONCLUSION
Proximal clavicular fracture is a type of fracture with low incidence. According to different fracture types, different internal fixation methods and treatment methods can be selected, and satisfactory surgical results can be achieved.
Male
;
Female
;
Humans
;
Adult
;
Middle Aged
;
Aged
;
Clavicle/surgery*
;
Treatment Outcome
;
Bone Plates
;
Fractures, Bone/surgery*
;
Fracture Fixation, Internal/methods*
;
Retrospective Studies

Result Analysis
Print
Save
E-mail